Hi,initially ,Autotransformer contactor and star contactor will on with the help of star / Delta timer .After 2 to 3 second Delta timer on and star timer off and Main contactor will be on ... So motor will run in delta means.. I hope you will correct it ...
SIR Just wanted to find out, motor is connected in delta or what? After auto transformer is disconnected since motor will eventually run at main contactor only???
PLEASE EXPLAIN WITH MODEL CALCULATIONS TO SELECT THE SIZING OF SPARES OLR, CONTACTOR MAIN CIRCUIT WIRES, AUTO TRANSFORMER SIZE , SF UNIT / MCB TO DIFFERENT HP MOTORS.
Hello. My father has a sawmill but after not using it for a while now there is a problem. When turned on it humming/buzzing but engine does not rotate. Engine uses 3 phases and all of it coming to the main fuses. Saw is rotating easily with hand so it's not jammed. I am not an expert in motors but I have a little bit experience in electronics. In electric box I saw that there is a autotransformer? (with SSRS tag :D) and it looks rusted/corroded so I guess there is a problem with it. Could it cause such a problem that engine is buzzing and not start? Maybe someone could help and say what should I check to find a problem? (I have multimeter so I can check continuity/measure voltages etc.)
Star delta starter power wiring
ruclips.net/video/I1x0gpcXTJ0/видео.html
Great graphical visual explanation. This makes the learning experience so realistic. Thank you
Very good explaination, rombe nandry sir
I refreshed my knowledge. Your video is very useful. Thank you bro
Hi..Sir this software what U user for vedio Sir? Diagram drowing
Great explanation and graphics
Will you do one on liquid starters with 3 phase slip ring motors
Very nice. Can do wiring for the transformer with a control circuit?
Thanks alot 😊
Hi,initially ,Autotransformer contactor and star contactor will on with the help of star / Delta timer .After 2 to 3 second Delta timer on and star timer off and Main contactor will be on ...
So motor will run in delta means..
I hope you will correct it ...
Then what is the use of main contactor their
SIR Just wanted to find out, motor is connected in delta or what? After auto transformer is disconnected since motor will eventually run at main contactor only???
Pls kindly explain tapping on a transformer. N pls post a clear pic of auto transformer
Thank you so much
You're most welcome
Super
sir how much k,w motor can be run from auto transformer circuit, it can run 160,200 k,w
PLEASE EXPLAIN WITH MODEL CALCULATIONS TO SELECT THE SIZING OF SPARES OLR, CONTACTOR MAIN CIRCUIT WIRES, AUTO TRANSFORMER SIZE , SF UNIT / MCB TO DIFFERENT HP MOTORS.
HOW TO SELECT THE SIZING OF SPARES OLR CONTACTOR MAIN CIRCUIT WIRES SF UNIT MCB TO ATS STARTERS . EXPLAIN WITH MODEL CALCULATION ( IN TAMIL)
Hello. My father has a sawmill but after not using it for a while now there is a problem. When turned on it humming/buzzing but engine does not rotate. Engine uses 3 phases and all of it coming to the main fuses. Saw is rotating easily with hand so it's not jammed.
I am not an expert in motors but I have a little bit experience in electronics. In electric box I saw that there is a autotransformer? (with SSRS tag :D) and it looks rusted/corroded so I guess there is a problem with it. Could it cause such a problem that engine is buzzing and not start? Maybe someone could help and say what should I check to find a problem? (I have multimeter so I can check continuity/measure voltages etc.)
I am weting control wiring auto transformer
soon i will published
Yes sir we are waiting for control wiring
We are waiting for control wiring
Worng wiring
😢
wrong wiring you got three leds and you have star shouldn't the motor be six leads
Hmm I wonder 🤔