please stop adding music, it ruins the video. that damn noise ug, its annoying and distracting. I have no issue listening to music I actually want to hear when I want to hear it. Thi channel isn't "the engineering mindsett and crappy music" . Also coudl you re-upload this video with out the music. I am sure you can easily delete the music with a few clicks.
love ur video...ive got a question, about delta connection. on a terminal BOX u make a delta connection manually in which U1W2, V1U2, AND W1V2. but during automation wiring from delta contactor connection it change the termination. ive got confuse. i dont have any problem on star contactor connetion. thanks..
@@EngineeringMindset Hi paul, just a mention i notice you didnt include the interlock wiring that enables the star and delta contactors to not run together.
Pls upload a video for a specifications for , star connection can be used upto howmany HP motor and delta connection can be used upto how many hp and star delta fir how many hp motors.
While it’s a reduced voltage method for starting, you must also remember it’s a reduced torque start also. If the motor can’t reach full speed in star, when it goes to delta, you can still see a huge amp draw spike if the changeover happens below full rpm.
This video is gold. This would have saved me from a lot of head scratching and heart burn years ago. Just remember, most older equipment in America is all one color of wire and nothing is ever label. It's always been worked on by 50 people who have no idea what the equipment is suppose to do. This video is awesome!
Thanks man, and a million blessings. I have never had anything explained so well I understood something I've been struggling with completely! I work with power systems and dub a lot in electrical systems though I am not an electrician, and I've been struggling with half-baked techs who mess things up a lot. I'm going to use your video lessons for my teams. You are a great teacher, thanks again.
This is one of the best videos u can ever watch about motor starters in Y and Delta configuration. I needs more than a 100 stars. Thanks alot Sir. I really learnt a whole lot more from ur tutorial.
The best explanation I have seen regarding Star Delta and why Star and Delta are used. Clarified some of my misnomas and the explanation helped me make sense and agree with what was being stated. Many discussions and forums I have looked at are under the impression that the motors run slower in star. Speed of a motor is determined by pole pairs and the frequency of the power source and then affected by slip between rotor and stator with flux density being a factor. Flux density is directly proportional to current. With 58% of the current in Star, there would be a reciprocating reduction in flux density. I suppose with lower torque due to lower flux density in the motor, motor slip may be greater and this would then align with comments that the motor runs slower than in Delta. Something I think I would like to test some time. Once again, a brilliant presentation of this subject.
Paul, thank you so much for your time and effort in producing the best and easiest to understand electrical engineering principles on youtube ! Your explanations and knowledge combined with your graphics are so next level - absolutely awesome stuff - Thank you
To some people confuse about his connection in delta read this.. He just makes in different way.. U1 can tap any of 2.. W2 and V2 And V1 can tap U2 and W2 W1 can tap U2 and V2 They are also delta. But never tap 1 and 2 same winding like you u1 and u2.. The thing you know is just basic one.. Thankyou so much your video..
I am a chemist and an organist, but no electrician. Wind for organ pipes is usually supplied by a large "squirrel cage" blower and a 5-to-50HP, 220V, 3-phase motor. This video brought a keen understanding of the "breaker box" that controls the motor, although I would never mess with it. Many thanks.
Just remember "ABC CAB" and you can work it out every time. Actually in Australia we generally use Red, White and Blue for phase colours with some motor cables used are Brown, Black and Blue.
I am a little bit confused in automation Y ∆ connection, in ∆ connection the U1 and W2 should be L1, V1 and U2 should be Line 2 and W1 and V2 should be Line 3. Why in video 5:00 is different?
@@josefernandosumbilon1146 The drawing is simply wrong...you guys are right. It would still work though, but the Delta would be a different and the engine would turn the other way. It would NOT work if you connect U1 to U2, V1 to V2 and W1 to W2, because then you just created a short circuit - 3 of them :-)
I connect U1 and W2 with R phase , V1 and U2 to Y phase , W1 and V2 with B phase and start the motor .............it runs in star smoothly but when delta contactor picked up motor windings get burn............it happens on 16-07-2021 ............I am unable to find the problem till yet........ please help me 😭
Thank you! Started studying electrical engineering and I’ve always struggled with this for some reason, you simplified it and narrowed it down enough that I got a very good understanding of it!
Engr. Ashok He just makes in difference way.. U1 can tap any of 2.. W2 and V2 And V1 can tap U2 and W2 W1 can tap U2 and V2 But never tap 1 in the same winding.. They are still delta.. The thing you know is just basic one..
Marwin Tisado My comments were in regards to min. 5:25 Motor terminals should be U1-W2, V1-U2, and W1-V2, because you need to be able to setup the motor for Star or Delta using the links. Thus from the main contactor you will have connections: L1 to U1, L2 to V1 and L3 to W1. From the star/delta contactors you will have connections: L1 to W2, L2 to U2 and L3 to V2. Hope this makes sense.
@@rauln1426 Right 2.50 he said for Delta configuration connect L1 to U1 to W2, L2 to V1 to U2 and L3 to W1 to V2 5.55 contradiction for Delta as figure shows L1 to U1 to V2', L2 to V1 to W2' and L3 to W1 to U2 The motor will work fine indeed but that 'mistake can confuse people learning the base.
Hi Paul Thank you for this informative and amazing video. I think beginners might be confused about the difference between the wiring of Delta connections shown in 2:50 and 5:00. Where, in the first connection, U1 and W2 were shorted, whereas, in the second, you shorted U1 and V2. The reason behind that is that shorting any two terminals of different letters results in having the motor connected in a delta configuration.
I think that in the second configuration it will try to change the direction when it switches to delta, and then it will draw a huge current and blow the fuses
Thanks a lot... You literally explain things better than boring college lectures... I wanted to understand this so badly. This video was super useful 👌
I live in Australia in the hvac industry and I can say we use red, white, blue for phases and black for neutral unless it’s flex cable which matches European colour code.
The delta configuration which is shown at 2:50 is actually the reverse of the one shown at 5:00. Will it have any effect other than just reversing the direction of rotation?
Yes , first Delta Connection is U1 to W2 , V1 to U2 , W1 to V2 second Delta Connection is U1 to V2 , V1 to W2, W1 to U2 It's different. I don't know why? Can anyone explain?
Very interesting! I never knew that star-delta (or wye -delta in the USA) was considered reduced voltage starting.One of the only things I knew was you had to have a 6 or 12 wire motor to be able to use this starting method.Your explanation made so much more sense then ever explained to me before and was a lot easier to follow. Thanks for sharing! Scott (USA)
Wow... i never imagined how it really works i read n explained verbally by many i never stood.. it gives me clear image how it works... amazed by ur explanation.
Great video! Nevertheless, there is one question that crossed. When you start showing the automation of changing star-delta at 4:50, in the animation it is demonstrated that W2 is connected to the yellow phase, U2 is connected to the blue phase and V2 is connected to the red phase, when delta configuration is being used. However, earlier in the video, at 2:55 it is shown that U2 along with V1 is connected to the yellow phase, W2 along with U1 is connected to the red phase and finally V2 along with W1 is connected to the blue phase. So I started wondering, why is there a change all of a sudden, to be more precise, why in the case of delta configuration W2 is connected to the red phase, but when it comes to star-delta automation is W2 connected to the yellow phase? I really can not find any logic behind that and would be grateful if you could answer my question.
I've watched this video multiple times and I caught that today and it confused me. Technically, it is still delta but it is confusing because normally delta is "across the line" which would be U1 to W2, V1 to U2, W1 to V2 and to be consistent with the live motor that was shown, it would be the same. Still a great video and I have recommended it countless times to people for a good visual to understand at least the concept.
I was hoping someone would have responded to your question because I too got confused when he introduced the contactors and started making the connections.
As someone who had an 8/10 on this exam. This made it a lot clearer for me now. This is more real world like. I could do the math easy by just noticing the right words. But when faced with this irl I checked this video first. THANK YOU !
you don't know how much you helped me, I wish I could have a 3d explanation of every topic that is difficult to unedrstand, thank you very very much, at present time I am not able to support you but believe me I'm going to really pay you when I will be capable of, thank you thank you very much
Great and clear explenations. I learned a lot about AC. Btw here in the Netherlands they raised the voltage to 230 v many years ago. I did not know in the UK you have 240 v. I connected my 220 v appliances (via an socket adapter) to the UK wall sockets, and appearantly the extra 20 v did not do any harm to them... I just bought you a cup of coffee. Enjoy!
All your appliances are rated to handle some variation. The UK is now meant to be 230V but most places you'll read closer to the 240V mark still. Thank you for support us, appreciated.
With this simplified video you have shredded all my queries. Thanks for this very help full video. Request you to please make a detailed video with timer and all contactors for AHU and chillers connection.
while I was in college - I majored in IT, but we had to listen to classes about electricity and electronics - nothing made sense back then. Now it does! I'm not an electrician, but I love to learn stuff about this, as I do work around my house everything regarding electricity! Safety first, people! Always double, triple check your circuit breakers! :)
I may be wrong, but at 5:00 shouldnt the wire from V2 be conneted into the L3 and also U2-L2 W2-LI, effectively W2-V2, V1-U2 and U1-W2 would be connected together making a delta connection, but they are flipped again
Sir, I am a fan of your channel. Nicely explained. Before this I have watched 🌟-delta from many RUclips channels but they are useless. Clearly explained. Sir please make video on 🌟-dekta control wiring. I am waiting. Thanks in advance.
I am not an electrical engineer, but as a hobby, I am very interested in electricity. I was able to find answers to many of my questions that I could not find answers to myself from your videos. Greetings from Turkey.
Seems to me that the diagram has an error. The Delta contactor's wiring looks to be out of phase. At 5:00 and onwards, Red wire (left contact) should go to W2, Yellow wire (center contact) should go to U2, and Blue wire (right contact) should go to V2.
The Engineering Mindset: 1 year ago "Alright guys calm down. It isn't a mistake it's simply a different way to connect it. You can change the direction of rotation by changing the connection. The manufacturer will provide a connection drawing and we have provided two on the accompanying article. I've provided multiple links to this but again it's here theengineeringmindset.com/star-delta-startes/ "
@@diagorasofmel0s but on video during explaination of automatic WYE Delta connection he does not metion about changing rotation. So it is kindi confusing
thats some awesome work with that animation ...you should be paid for this stuff more than the old fashioned university teachers...again great great work keep it up buddy!!!
@@scottkasper6378 there a video to explain, or example? Looks like on a CW rotation, can connect to the ascending phase, but does that need to go through a load or how that work?
@@MattFerguson26 It has to go through a load of course, or the resistance will be 0, thereby also the voltage drop will mean that the circuit will be at 0V. The breaker will also pop since you will be drawing too much current.
Its not just the sudden drain and voltage drop from starting in delta, the motor itself experiences very big forces. When i studied this stuff when i was a teen we got to do lots of practical stuff on our own, starting big motors in delta released big forces that would twist/shake the motors violently and it made terrible cranking sounds for a short time.
Simply genius, after 18 years due to your graphic I understand that due to neutral point in star configuration we get near about 1/3 current. Heads off
@@EngineeringMindset sir. i have question. is delta or wye configurations capacitor connection are the same? what capacitor connection should it be ? parallel or series at neutral line or live line?
I'm a mechanical engineer that has just retired after a 30 year career. I must say this video was brilliantly explained. If RUclips had been around when I was a student life would have been a lot easier...:)
@@mahadljama4578 Ahh yes I graduated in the UK but it has been many years since I emigrated to the USA so I am not familiar with the employment market there. I do wish you the best of luck. Where did you study?
Watts up! I just learned on how a.c motor works on the physics level of it and i find enjoyable to see correlation between a.c and magnets including the creative way they can produce something like this.
Thank you, you explain so well! I was wondering do you will ever do a video about yourself such as what type of engineer you are(electrical engineering?) or like how like long you’ve been in the field for. Since you seem so knowledgeable. Thanks!
so we had several classes on this at school. i have actually BUILT this system and it was functional. but i still had no idea what i was doing. thanks to this video i now know.
Hey you guys are awesome and very informative. You explain it well in ways I can understand easily.. Could or would you do a video on high-leg delta by chance? Thanks again!!
Hi there super helpful video. Helps me understand and grow as an electrician. Quick side note, im from Australia, we generally use RED, WHITE, BLUE as our three phases.
The timer from my experience has a delay change over time of 40ms. This is to allow the arc generated on the star contactor to dissipate when switching off before the delta contactor energises. I have a formulae that works out the motor direction without energising the motor as long as the main supply is in synch
Correct me if i am wrong, but as an industrial electrician for 40 years, we used to set the timer to allow the motor to accelerate to full (or almost) full speed. this is mainly to reduce starting current on a limited capacity supply
There used to be a semi manual approach to changing over star-delta Allen West had dashpot starters where you had to press the start button then change over using a manual handle to operate the change over contacts. Whilst crude compared to using contactors the Allen west dashpots were very robust and were able to tolerate poor environments and misuse.
Excellent. Concise and well explained. A very minor audio correction, At video time (9:24) : should say 20xsqrt(3) Amps instead of 20/sqrt(3) Amps. Well done.
⚠️ *Found this video super useful?* Buy Paul a coffee to say thanks: ☕
PayPal: www.paypal.me/TheEngineerinMindset
Download video here: ➡️ electricl.info/star-delta-download
please stop adding music, it ruins the video. that damn noise ug, its annoying and distracting. I have no issue listening to music I actually want to hear when I want to hear it. Thi channel isn't "the engineering mindsett and crappy music" . Also coudl you re-upload this video with out the music. I am sure you can easily delete the music with a few clicks.
love ur video...ive got a question, about delta connection. on a terminal BOX u make a delta connection manually in which U1W2, V1U2, AND W1V2. but during automation wiring from delta contactor connection it change the termination. ive got confuse. i dont have any problem on star contactor connetion. thanks..
@@chovsalts606 See the wiring diagrams here EngMind.info/Star-Delta-Starters
@@EngineeringMindset Hi paul, just a mention i notice you didnt include the interlock wiring that enables the star and delta contactors to not run together.
Pls upload a video for a specifications for , star connection can be used upto howmany HP motor and delta connection can be used upto how many hp and star delta fir how many hp motors.
this is the best explanation of star delta configuration on entire youtube
I agree!
9:21 "divided by" should be, as written, "multiplied by".
Excellent, no-noise presentation, a real pleasure to watch.
While it’s a reduced voltage method for starting, you must also remember it’s a reduced torque start also. If the motor can’t reach full speed in star, when it goes to delta, you can still see a huge amp draw spike if the changeover happens below full rpm.
This video is gold. This would have saved me from a lot of head scratching and heart burn years ago. Just remember, most older equipment in America is all one color of wire and nothing is ever label. It's always been worked on by 50 people who have no idea what the equipment is suppose to do. This video is awesome!
Agreed. I am currently working at an unnamed university. And nothing is labeled and every wire is the same color.
Thanks man, and a million blessings. I have never had anything explained so well I understood something I've been struggling with completely! I work with power systems and dub a lot in electrical systems though I am not an electrician, and I've been struggling with half-baked techs who mess things up a lot. I'm going to use your video lessons for my teams. You are a great teacher, thanks again.
This is by far the best ever explanation of star delta configuration on the entire internet!!!
This is one of the best videos u can ever watch about motor starters in Y and Delta configuration. I needs more than a 100 stars.
Thanks alot Sir. I really learnt a whole lot more from ur tutorial.
The best explanation I have seen regarding Star Delta and why Star and Delta are used. Clarified some of my misnomas and the explanation helped me make sense and agree with what was being stated. Many discussions and forums I have looked at are under the impression that the motors run slower in star. Speed of a motor is determined by pole pairs and the frequency of the power source and then affected by slip between rotor and stator with flux density being a factor. Flux density is directly proportional to current. With 58% of the current in Star, there would be a reciprocating reduction in flux density. I suppose with lower torque due to lower flux density in the motor, motor slip may be greater and this would then align with comments that the motor runs slower than in Delta. Something I think I would like to test some time. Once again, a brilliant presentation of this subject.
Paul, thank you so much for your time and effort in producing the best and easiest to understand electrical engineering principles on youtube ! Your explanations and knowledge combined with your graphics are so next level - absolutely awesome stuff - Thank you
,
To some people confuse about his connection in delta read this..
He just makes in different way.. U1 can tap any of 2.. W2 and V2 And
V1 can tap U2 and W2
W1 can tap U2 and V2
They are also delta.
But never tap 1 and 2 same winding like you u1 and u2..
The thing you know is just basic one..
Thankyou so much your video..
I must have missed that electrical lecture 20 years ago. I still think that any mechanical engineer should know this!
I am a chemist and an organist, but no electrician. Wind for organ pipes is usually supplied by a large "squirrel cage" blower and a 5-to-50HP, 220V, 3-phase motor. This video brought a keen understanding of the "breaker box" that controls the motor, although I would never mess with it. Many thanks.
Just remember "ABC CAB" and you can work it out every time. Actually in Australia we generally use Red, White and Blue for phase colours with some motor cables used are Brown, Black and Blue.
That a great formula . I just learned it today by my friend who is chargeman .
Thanks for letting them know we use red, white, blue! Couldn’t leave the video until it had been noted
You change my life 😅🙏😅 now i will remember it till i dye.
Thanks you have made my life way easier
Hi
I am a little bit confused in automation Y ∆ connection, in ∆ connection the U1 and W2 should be L1, V1 and U2 should be Line 2 and W1 and V2 should be Line 3. Why in video 5:00 is different?
Same for me, im a still a student, please can someone explain?
@@josefernandosumbilon1146 The drawing is simply wrong...you guys are right. It would still work though, but the Delta would be a different and the engine would turn the other way. It would NOT work if you connect U1 to U2, V1 to V2 and W1 to W2, because then you just created a short circuit - 3 of them :-)
@@bluehome8193 I Noticed the samething, the drawing shown at 5:00min is wrong
Glad I’m not the only one confused by this
I connect U1 and W2 with R phase , V1 and U2 to Y phase , W1 and V2 with B phase and start the motor .............it runs in star smoothly but when delta contactor picked up motor windings get burn............it happens on 16-07-2021 ............I am unable to find the problem till yet........ please help me 😭
Thank you! Started studying electrical engineering and I’ve always struggled with this for some reason, you simplified it and narrowed it down enough that I got a very good understanding of it!
I’m now at the stage of revision where I’m typing things I don’t understand into RUclips and praying that this channel has a video on it!🙏🏻
Delta connections at motor terminal:
L1 to W2
L2 to U2
L3 to V2
He doesn't say like that
You are correct bro.
Engr. Ashok
He just makes in difference way.. U1 can tap any of 2.. W2 and V2 And
V1 can tap U2 and W2
W1 can tap U2 and V2
But never tap 1 in the same winding..
They are still delta..
The thing you know is just basic one..
Marwin Tisado
My comments were in regards to min. 5:25
Motor terminals should be U1-W2, V1-U2, and W1-V2, because you need to be able to setup the motor for Star or Delta using the links.
Thus from the main contactor you will have connections: L1 to U1, L2 to V1 and L3 to W1.
From the star/delta contactors you will have connections: L1 to W2, L2 to U2 and L3 to V2.
Hope this makes sense.
@@rauln1426 Right
2.50 he said for Delta configuration connect L1 to U1 to W2, L2 to V1 to U2 and L3 to W1 to V2
5.55 contradiction for Delta as figure shows L1 to U1 to V2', L2 to V1 to W2' and L3 to W1 to U2
The motor will work fine indeed but that 'mistake can confuse people learning the base.
Incredible. You are the best engr. For me. Thanks.
Great video, this give me flashbacks of countless hours wiring up Telemecanique contactors & overloads.. Long live the VFD :)
dude, this channel is absolute gold.
Hi Paul
Thank you for this informative and amazing video.
I think beginners might be confused about the difference between the wiring of Delta connections shown in 2:50 and 5:00. Where, in the first connection, U1 and W2 were shorted, whereas, in the second, you shorted U1 and V2.
The reason behind that is that shorting any two terminals of different letters results in having the motor connected in a delta configuration.
Thank, I think you're right. We just uploaded some wiring diagrams to help with this also. EngMind.info/Star-Delta-Starters
I think that in the second configuration it will try to change the direction when it switches to delta, and then it will draw a huge current and blow the fuses
YOU ARE BRILLIANT AND NOTED THE BEGINNERS PROBLEM.I AM BEGINNER.THANKS.HOPE IT HAS 2 OPTIOS FOR DIRECTION CHANGE
This set up is used in industrial laundry washers , forward, reverse, balance speed, we also use inverters….
Excelent video, I am taking a tri-phase eletricity course in college and this is just what i needed! You won a subscriber, pal!
This channel is the STAR of youtube science!
Thanks a lot... You literally explain things better than boring college lectures... I wanted to understand this so badly. This video was super useful 👌
THIS IS JUST THE BEST EXPLANATION IVE EVER GOTTEN ABOUT STAR DELTA CONFIGURATIONS, THANKS ALOT
I live in Australia in the hvac industry and I can say we use red, white, blue for phases and black for neutral unless it’s flex cable which matches European colour code.
It's in the AS3000
Basically what you stated.
Great explanation, Australia uses R,W,B as phase colours.
The delta configuration which is shown at 2:50 is actually the reverse of the one shown at 5:00. Will it have any effect other than just reversing the direction of rotation?
Yes , first Delta Connection is
U1 to W2 , V1 to U2 , W1 to V2
second Delta Connection is
U1 to V2 , V1 to W2, W1 to U2
It's different. I don't know why?
Can anyone explain?
@@kaungmyatphone8576 tru guys, just a simple mistake i think
Haven't done a star-delta starter system in a long time, so thanks for the memory refresher!
Very interesting! I never knew that star-delta (or wye -delta in the USA) was considered reduced voltage starting.One of the only things I knew was you had to have a 6 or 12 wire motor to be able to use this starting method.Your explanation made so much more sense then ever explained to me before and was a lot easier to follow. Thanks for sharing! Scott (USA)
I subscribed instantly after finishing to watch this video
You explained very well. Engineering is our field.. Thanks for sharing
Wow... i never imagined how it really works i read n explained verbally by many i never stood.. it gives me clear image how it works... amazed by ur explanation.
Thank you for the great explanation! I have been working maintenance in factories for many years and now finally understand the how and why.
This channel is the best for electrical components explanations
Great video! Nevertheless, there is one question that crossed. When you start showing the automation of changing star-delta at 4:50, in the animation it is demonstrated that W2 is connected to the yellow phase, U2 is connected to the blue phase and V2 is connected to the red phase, when delta configuration is being used. However, earlier in the video, at 2:55 it is shown that U2 along with V1 is connected to the yellow phase, W2 along with U1 is connected to the red phase and finally V2 along with W1 is connected to the blue phase. So I started wondering, why is there a change all of a sudden, to be more precise, why in the case of delta configuration W2 is connected to the red phase, but when it comes to star-delta automation is W2 connected to the yellow phase? I really can not find any logic behind that and would be grateful if you could answer my question.
Yea I have the same inquiry and probably it was a mistake
I've watched this video multiple times and I caught that today and it confused me. Technically, it is still delta but it is confusing because normally delta is "across the line" which would be U1 to W2, V1 to U2, W1 to V2 and to be consistent with the live motor that was shown, it would be the same. Still a great video and I have recommended it countless times to people for a good visual to understand at least the concept.
same here.,As electrical maintenance, I have not seen a connection like that before... I tried to simulate it and it doesn't work.
I was hoping someone would have responded to your question because I too got confused when he introduced the contactors and started making the connections.
This is addressed in a comment posted by a guy called "G" a few comments below yours
As someone who had an 8/10 on this exam. This made it a lot clearer for me now. This is more real world like. I could do the math easy by just noticing the right words. But when faced with this irl I checked this video first. THANK YOU !
Thanks a million for this info.you have explained step by step , you are a great teacher
you don't know how much you helped me, I wish I could have a 3d explanation of every topic that is difficult to unedrstand, thank you very very much, at present time I am not able to support you but believe me I'm going to really pay you when I will be capable of, thank you thank you very much
Great and clear explenations. I learned a lot about AC. Btw here in the Netherlands they raised the voltage to 230 v many years ago. I did not know in the UK you have 240 v. I connected my 220 v appliances (via an socket adapter) to the UK wall sockets, and appearantly the extra 20 v did not do any harm to them... I just bought you a cup of coffee. Enjoy!
All your appliances are rated to handle some variation. The UK is now meant to be 230V but most places you'll read closer to the 240V mark still. Thank you for support us, appreciated.
With this simplified video you have shredded all my queries.
Thanks for this very help full video.
Request you to please make a detailed video with timer and all contactors for AHU and chillers connection.
These videos are so useful to just come back and check on over the years as the old memory fades 👍
one of the best info I have gotten on this subject. well done
The best explanation of star delta configuration :)
Thank you ans God bless you. My third and final year of college in a 10min video.
Which college
while I was in college - I majored in IT, but we had to listen to classes about electricity and electronics - nothing made sense back then. Now it does!
I'm not an electrician, but I love to learn stuff about this, as I do work around my house everything regarding electricity! Safety first, people! Always double, triple check your circuit breakers! :)
I may be wrong, but at 5:00 shouldnt the wire from V2 be conneted into the L3 and also U2-L2 W2-LI, effectively W2-V2, V1-U2 and U1-W2 would be connected together making a delta connection, but they are flipped again
yes you are correct
You are right
i came in comment section to verify this.
This channel is highly underated channel
This graphics are amazing for learning. Great job!
i cant believe what a good explanation this video was.
Sir, I am a fan of your channel. Nicely explained. Before this I have watched 🌟-delta from many RUclips channels but they are useless. Clearly explained. Sir please make video on 🌟-dekta control wiring. I am waiting. Thanks in advance.
These videos are so under rated...
This is the best video for star delta. Every engineers should watch this. Thanks
Absolutely right bro
You are Rigth i learned so much
I am not an electrical engineer, but as a hobby, I am very interested in electricity. I was able to find answers to many of my questions that I could not find answers to myself from your videos. Greetings from Turkey.
Seems to me that the diagram has an error. The Delta contactor's wiring looks to be out of phase. At 5:00 and onwards, Red wire (left contact) should go to W2, Yellow wire (center contact) should go to U2, and Blue wire (right contact) should go to V2.
Absolutely. As we see the connectors in the terminal box without contactors
The Engineering Mindset: 1 year ago
"Alright guys calm down. It isn't a mistake it's simply a different way to connect it. You can change the direction of rotation by changing the connection. The manufacturer will provide a connection drawing and we have provided two on the accompanying article. I've provided multiple links to this but again it's here theengineeringmindset.com/star-delta-startes/ "
Very good to detect the wrong point.
@@diagorasofmel0s but on video during explaination of automatic WYE Delta connection he does not metion about changing rotation. So it is kindi confusing
@The Engineering Mindset please can you explain this, i confused to.🙏
The best video for 3 phase power. Thanks guys
Well done, great explanation! I've created a PSCAD case that simulates IM starting from star and then switching over to delta.
I am interested in this, where can I access your work?
thats some awesome work with that animation ...you should be paid for this stuff more than the old fashioned university teachers...again great great work keep it up buddy!!!
Awesome video. I'm curious how the cross phase of wiring doesn't create a fault.
Minor edit needed @ 9:21, meant to say multiplied by.
@@scottkasper6378 there a video to explain, or example? Looks like on a CW rotation, can connect to the ascending phase, but does that need to go through a load or how that work?
@@MattFerguson26 It has to go through a load of course, or the resistance will be 0, thereby also the voltage drop will mean that the circuit will be at 0V. The breaker will also pop since you will be drawing too much current.
I = V / R?
prasley bustommy and v=IxR and R = V/I
Seen our new incredibly detailed MCB video? link: ruclips.net/video/gqEu9t8HwW0/видео.html
After 20 years in the trade I finally understand visually what is happening. Bless you and all your videos. I always feel full after every video.
“Watts up”. Love your work!
The best explanation and illustration I have seen. Thank you so much!
now this is enlightenment, pretty much explain everything i want to know, about... thank you sir
Excellent explanation about the star delta system for three phase motors.
Its not just the sudden drain and voltage drop from starting in delta, the motor itself experiences very big forces. When i studied this stuff when i was a teen we got to do lots of practical stuff on our own, starting big motors in delta released big forces that would twist/shake the motors violently and it made terrible cranking sounds for a short time.
Or a sudden change of direction on a heavy induction motor with a flywheel or something like that will likely destroy the coils and bearings.
Well that's how my computer starts
Simply genius, after 18 years due to your graphic I understand that due to neutral point in star configuration we get near about 1/3 current. Heads off
Thanks again Paul @EngineeeingMindset
Glad you enjoyed the video
@@EngineeringMindset sir. i have question. is delta or wye configurations capacitor connection are the same? what capacitor connection should it be ? parallel or series at neutral line or live line?
Great video this will save me time explaining to some people
There's a small mistake at 9:21. I think you accidentally said "divided" when you multiplied 20A * sqrt(3)
I'm a mechanical engineer that has just retired after a 30 year career. I must say this video was brilliantly explained. If RUclips had been around when I was a student life would have been a lot easier...:)
I am reason graduate mechanical engineer struggling to find job any tips Sir.
@@mahadljama4578 Are you based in the USA?
@@frankish5314 No sir I am in UK sorry for misspelling of recent
@@mahadljama4578 Ahh yes I graduated in the UK but it has been many years since I emigrated to the USA so I am not familiar with the employment market there. I do wish you the best of luck. Where did you study?
@@frankish5314 in Southampton England
Watts up!
I just learned on how a.c motor works on the physics level of it and i find enjoyable to see correlation between a.c and magnets including the creative way they can produce something like this.
Glad you liked it
@@EngineeringMindset hi may i know whatvsoftware you ise to create such animations?
hats off. thanks for helping beginners and graduating engineers
Thank you, you explain so well! I was wondering do you will ever do a video about yourself such as what type of engineer you are(electrical engineering?) or like how like long you’ve been in the field for. Since you seem so knowledgeable. Thanks!
This comment is weird 😻
Absolutely mind blowing... I have been removed all confusion after seeing this Video. Thank you!
Love your videos! Easy to understand
You are the best among the best sir, this is the simplest explanation I ever have in star delta convertion. God bless you sir.
Now i understand clearly the star delta config. I am wondering for this for so long time🤣
so we had several classes on this at school.
i have actually BUILT this system and it was functional. but i still had no idea what i was doing.
thanks to this video i now know.
Thanks, I'll need to watch this a few times until it sinks in...
Do not worry about that, if you stop 10 white vans, with a electrician in it, 9 of them could NOT draw this schematic, without calling a friend LOL
Great info. My new employer will think I am a pro after watching your videos and more. Thanks.
Hey you guys are awesome and very informative. You explain it well in ways I can understand easily.. Could or would you do a video on high-leg delta by chance? Thanks again!!
Hi there super helpful video. Helps me understand and grow as an electrician. Quick side note, im from Australia, we generally use RED, WHITE, BLUE as our three phases.
The timer from my experience has a delay change over time of 40ms. This is to allow the arc generated on the star contactor to dissipate when switching off before the delta contactor energises. I have a formulae that works out the motor direction without energising the motor as long as the main supply is in synch
Correct me if i am wrong, but as an industrial electrician for 40 years, we used to set the timer to allow the motor to accelerate to full (or almost) full speed. this is mainly to reduce starting current on a limited capacity supply
Beautiful work. I never understood this better
Thanks for the very well explained star delta connection,configuration and function. Your new subscriber here!
Wow the best vid I have seen so far _ very good job guys, keep up the great work!!!
thanks for this excellent vid..please make another about generator excitation system🙏
Great Video, New Job with many old motor starters. WHAT A AMAZING BASIC Summary. Thanks
What about the relationship between voltage difference 58% & current difference 33% , why not both a positive ratio?
if yor motor is 380v and running in 230 volt you will not get the nominal power after you move to deltaconnection you will got the nominal power
I'm a chemical engineer and mildly allergic to electrical work... somehow you managed to make wye-delta make sense. Magic
Sir just one problem in your connection moter is running opposite direction
Check the schematics here EngMind.info/Star-Delta-Starters
i wish i had you in 2009 Lol ...you are better than any college in my area
There used to be a semi manual approach to changing over star-delta Allen West had dashpot starters where you had to press the start button then change over using a manual handle to operate the change over contacts. Whilst crude compared to using contactors the Allen west dashpots were very robust and were able to tolerate poor environments and misuse.
wish i could like 1000 times. very well explained. good job
Nice video. Should say ''AC" not "AC current" ...
Because "AC" mens : alternative current
And "AC" COURANT means: alternative current current.
Courant?????????
@@mahdimahdi7486
You sure it's not "alternating"?
@@FallingAsleep_12 i was writing in french keyboard 😅
@@mahdimahdi7486it's actually alternating cycle current
Excellent. Concise and well explained.
A very minor audio correction, At video time (9:24) : should say 20xsqrt(3) Amps instead of 20/sqrt(3) Amps.
Well done.
Excuse me, I ask permission to take a video for my thesis data, is it permissible?
i want to thank you from my button of my heart for this amazing set of information !