POCV | Parametric On-Chip Variation | Static Timing Analysis | VLSI

Поделиться
HTML-код
  • Опубликовано: 20 янв 2025

Комментарии • 36

  • @p_phanindra3465
    @p_phanindra3465 3 года назад +2

    Thanks mahendra for making pocv things clear... Kudos to u..

    • @mmkr
      @mmkr  3 года назад

      No problem. Thanks for watching.

  • @ramana0070
    @ramana0070 6 месяцев назад

    This is a wonderful video, thanks a lot for your effort!!

  • @praneethbogavilli5199
    @praneethbogavilli5199 3 года назад +2

    Good information .Plz do as many videos as possible.

    • @mmkr
      @mmkr  3 года назад

      Glad to hear that. I’ll try my best 😊

  • @kirtirajput531
    @kirtirajput531 Год назад +1

    hey can u please explain what is exactly nominal delay?

  • @jayalakshmisirivella
    @jayalakshmisirivella Год назад

    What is statistical adjustment in 3 sigma timing reports can you please explain?

  • @ghanshu369
    @ghanshu369 2 года назад

    Amazing video , thank you so much.
    Please advise , what would be meaning of cell check variation in yor presentation ?

  • @nishadpadariya5341
    @nishadpadariya5341 3 года назад +2

    Thanks a lot for such informative video

    • @mmkr
      @mmkr  3 года назад +1

      You’re welcome.

  • @User--jm5911
    @User--jm5911 5 месяцев назад

    What is nominal delay?

  • @pavannaidu6021
    @pavannaidu6021 10 месяцев назад

    in timing report what is meant by statistical adjustment value? In place stage the value is zero and in CTS the value is added , can u please explain in brief

  • @kodidalamaheshbabu9242
    @kodidalamaheshbabu9242 2 года назад +1

    Thanks lot sir !! very helpful !!

    • @mmkr
      @mmkr  2 года назад

      Glad to hear that. Thanks for your feedback.

  • @manju2323
    @manju2323 Год назад

    Is socv different from pocv analysis?

  • @dharmendrakiit
    @dharmendrakiit 3 месяца назад

    Hello Sir, I have some concern with Pocvm Gaurdbanding slides, if we use this Gaurdbanding for other variations than the Random variation i.e. voltage and temperature , this gaurdband value gets multiply with distance based derating also … that is not correct right?
    No fab explains about derating the distance based derate again!!
    Also why would we want to derate the sigma value with this Gaurdbanding? Voltage and temperature derates are supposed to be incremental derates on existing POCVM derates which means no multiplication is required!! All derates should be incrementally used!! This is what is mentioned by Fabs like TSMC 7/5 nm Signoff docs, they have not mentioned a single word about Gaurdbanding rather they have clearly mentioned that derates are needed to be applied with -incr switch only!!!
    Expecting a reply from your side!! After that we can discuss it more!

  • @koteswararao.k2694
    @koteswararao.k2694 3 года назад +1

    Very Good Information

    • @mmkr
      @mmkr  3 года назад

      Thank you. Glad to hear that.

  • @PraveenGhanta-g3w
    @PraveenGhanta-g3w 4 месяца назад

    The calculation for Delay of cell = Mean + (C*Mean*N),, where Mean is the nominal delay of cell, and N is the standard deviations ,, with this we are covering complete variation, then again what is the use of Pocv Coefficient C in the formula ?? can anyone explain clearly to me

  • @AJAYKUMAR-ve2kk
    @AJAYKUMAR-ve2kk 2 года назад

    Hi Sir, i have one doubt, can you explain how AOCV derates impacts on Half-cycle paths & CRPR?

    • @atuntripathy
      @atuntripathy Год назад +1

      aocv has no impact of clock edge

  • @nareshtellakula3131
    @nareshtellakula3131 3 года назад +1

    Very informative,please make videos on annotation fixes

    • @mmkr
      @mmkr  3 года назад

      Thank you. I’ll think about that later.

  • @User--jm5911
    @User--jm5911 3 года назад

    Can you explain CRPR concept

  • @mdhanunjayrao5667
    @mdhanunjayrao5667 2 года назад +1

    Nice information

    • @mmkr
      @mmkr  2 года назад

      Thank you

  • @MrSatyanshuu
    @MrSatyanshuu 3 года назад

    What is the purpose of Corner? btw thanks for details :)

  • @dhirajthalladi4934
    @dhirajthalladi4934 3 года назад +1

    Hi sir, Great video can you please explain what is systematic variation and what does the distance in table Indicate I mean distance between what?

    • @mmkr
      @mmkr  3 года назад +1

      Thank you.
      Systematic variation is deterministic in nature and is proportional to the cell location of the path being analyzed. Examples of systematic variations are variations in gate length/width and interconnection width.These variations basically relate to proximity effects, density effects and the relative distance of devices.
      The cell path distance is determined by computing the diagonal of a cell bounding box which encompasses all of the cells in the path. Note, path distance is calculated separately for cells and nets, because a timing analysis tool assumes the locations of the nets in a path do not affect the systematic variation of the cells in the path.

    • @dhirajthalladi4934
      @dhirajthalladi4934 3 года назад +2

      @@mmkr Thank you sir

    • @mmkr
      @mmkr  3 года назад

      You’re welcome

  • @vikineo
    @vikineo 2 года назад +1

    can we add chapters with timestamp? easier to navigate the video that way.

    • @mmkr
      @mmkr  2 года назад

      Thanks for your suggestion, I’ll try to do it later.

  • @travelfreakphani5933
    @travelfreakphani5933 4 месяца назад

    super thanks

  • @jingalala-yg4dp
    @jingalala-yg4dp Месяц назад

    hola