BROKEN CONCEALED CISTERN | How to change these the easy way & CENTRAL HEATING PUMP swap

Поделиться
HTML-код
  • Опубликовано: 16 ноя 2024

Комментарии • 89

  • @MJTiffPlumbing
    @MJTiffPlumbing  2 года назад +2

    Anything ordered from Unilite get 25% off with the code “MJTIFF”….🙌🏼🙌🏼

  • @philgrant1801
    @philgrant1801 2 года назад +2

    Hi Mark, I've been watching the channel for a while now. Love the down to earth honest approach, no dressing it up, just saying it like it is. Finding a good plumber can be really hard. I'm an expat in France and finding reliable plumbers and other trades can be a real struggle. Keep up the great work. You deserve every success. Looking forward to seeing the finished bathroom, you'll be a happy man once it's finished.

    • @MJTiffPlumbing
      @MJTiffPlumbing  2 года назад

      Thanks Phil…. Glad you like my style of content in making and putting out.🙏🏼

  • @nickcollins7568
    @nickcollins7568 2 года назад +7

    That is a Dudley Vantage cistern you removed. It is very easy to replace the flush valve without having to remove the cistern. Simply unclip fill valve so it will go up a bit Then twist flush valve off cradle and one can then pull up and out flush valve completely. I have replaced the flush valve in about 10 minutes

    • @MJTiffPlumbing
      @MJTiffPlumbing  2 года назад +5

      This one needed the whole lot changing, the ball valve was knackered aswell…..

    • @davidkneale7455
      @davidkneale7455 2 года назад +1

      I did that and the lugs on the syphon snapped off. I did get a new syphon in though. My leak was however on the flush pipe which has gone brittle and a piece has broken off!
      All toiled in too!

  • @mattygeepph4115
    @mattygeepph4115 2 года назад +1

    Top job mark as always good call on the pump there's a lot of hard water round Warwick/ Leamington was in plumbase Warwick the other day 👍😎👍😎👍😎

    • @MJTiffPlumbing
      @MJTiffPlumbing  2 года назад +1

      Thanks mate…. Yep water round here is rubbish

  • @adierob1
    @adierob1 2 года назад +2

    Great job with the cistern mark they can be a right pain them especially buried behind a tiled wall. Don't know if your aware of it but toilet cisterns are classed as a fluid category 3 risk and should have a double check valve fitted since they got rid of the jonnys on float valves and introduced these silent fill float valves that sit in the water there is an increased chance of toilet cistern chemicals such as blue loo and cistern blocks back symphoning into the household water supply. Had it happen on a job last week as the woman of the house is obsessed with bleach.

    • @MJTiffPlumbing
      @MJTiffPlumbing  2 года назад

      Interesting mate, wasn’t mentioned on my recent G3 renewal course.

  • @TheLeedsleedsleeds
    @TheLeedsleedsleeds 2 года назад +2

    Great stuff mark 👍👍👍
    Absolutely nothing wrong putting different brand fitting on plastic pipe.
    As long as it’s the correct insert I’m sure all the pipe is the same BS number

    • @MJTiffPlumbing
      @MJTiffPlumbing  2 года назад +1

      Yep, I’ve never had an issue as long as it’s fitted correctly…. Just mentioned it before the fitting police came and arrested me🤣

  • @chrisholt2474
    @chrisholt2474 2 года назад +2

    Hi Mark, the bathroom is coming on a treat now, the brick replacement was an excellent job too.
    An interesting job with the enclosed system, but it was all good in the end, well done.
    I am aiming to be at installer show on Wednesday all being well and looking forward to it.
    Another great film as always, thank you, have a great week at the show, take care, regards, Chris.👍👍👍

    • @MJTiffPlumbing
      @MJTiffPlumbing  2 года назад

      Thanks as always Chris…. Make sure you come and say hello 👍🏼👍🏼

    • @chrisholt2474
      @chrisholt2474 2 года назад

      @@MJTiffPlumbing yep I will try to find you on the snug stand, 🍻👍👍

  • @kevinisaac9139
    @kevinisaac9139 2 года назад +1

    Nice one mark you’re lucky those pump valve hold back usually don’t 😩

  • @pauladriandavies3840
    @pauladriandavies3840 2 года назад +1

    Great to see you today Mark ,and to chew the fat. London Paul. Keep The Faith. 👍🇬🇧

    • @MJTiffPlumbing
      @MJTiffPlumbing  2 года назад

      Thanks buddy….. busy few days for me…👍🏼👍🏼

  • @joshuaainsworth3909
    @joshuaainsworth3909 2 года назад +1

    Where did you get the roper rhodes cistern from, must have missed it .

  • @DjSOTA
    @DjSOTA 2 года назад +1

    Great video as always! Wow you found a tidy tiler! 🤣👍🏻

  • @Dannyboy207
    @Dannyboy207 2 года назад +4

    Hey mark you need to start doing t shirts and hoodies with the saying ( I’ve never had an issue with it ) haha

  • @zaclevy8784
    @zaclevy8784 2 года назад +2

    Great job but you need to turn the pump as if vertical you can run the bearing dry and more prone to air problems

    • @MJTiffPlumbing
      @MJTiffPlumbing  2 года назад

      All ready done mate….. 👍🏼👍🏼

  • @bryanporter3025
    @bryanporter3025 2 года назад +2

    Great mix of Jobs there pal 👍

  • @anserkhan9430
    @anserkhan9430 2 года назад +1

    Hi mate love your videos, a quick question what mixer shower brands would you recommend?

    • @MJTiffPlumbing
      @MJTiffPlumbing  2 года назад

      Thanks buddy…. Aqualisa mixers are great

  • @glyndavies591
    @glyndavies591 2 года назад +1

    Enjoyable video again have a good time in the installers show

    • @MJTiffPlumbing
      @MJTiffPlumbing  2 года назад

      Thanks Glyn…. Will be recording the days in there so people can have an insight

  • @darrenmackenzie1892
    @darrenmackenzie1892 2 года назад +1

    How do you stop the flush pipe from leaking late on after the installation? Do you recommend silicone it up?

    • @MJTiffPlumbing
      @MJTiffPlumbing  2 года назад

      Fit a new flush cone to be honest mate👍🏼👍🏼

  • @martin54123
    @martin54123 2 года назад +1

    Another excellent video, thank you

  • @capraniplumbingandheating
    @capraniplumbingandheating 2 года назад +1

    Yes then Mark,
    Smashed it as always 👊🔥
    Did good with that cistern mate

    • @MJTiffPlumbing
      @MJTiffPlumbing  2 года назад

      Yes brother🙌🏼🙌🏼🙏🏼🙏🏼……. You heading to Installer mate??

  • @karl212
    @karl212 2 года назад +1

    Do the tilers not glue the backer board down first then screw aswell ?

    • @MJTiffPlumbing
      @MJTiffPlumbing  2 года назад

      Screwed down then sealed and primed before tiling…. You don’t need to glue it

    • @karl212
      @karl212 2 года назад

      Pretty sure hardi recommend put thinset down first then screwing down in marked places on board ...but if your method works with no issues then all good 👍

  • @abidh4253
    @abidh4253 2 года назад +1

    Hi mark, could you make a video for us apprentices who are coming to the end of our apprenticeship a video on how to start our own company and maybe some tips and things to expect

    • @MJTiffPlumbing
      @MJTiffPlumbing  2 года назад +1

      That is a good idea…. I will see what I can do

  • @petebarby1315
    @petebarby1315 2 года назад +1

    Hey Mctiff try the torrent comfort height cistern its 40mm less in height gives you a bit more play with the flush pipe TR9008

  • @robertmorris5214
    @robertmorris5214 2 года назад +1

    Great content Mark

  • @andybrady9561
    @andybrady9561 2 года назад +1

    Brilliant work again mate, the bathroom coming on nicely 👏 that pump shouldn't be fitted on it's back as it ruins the bearing well they used to 10 years ago 😀 keep up with the honest hard and awkward sh t your up against every day 👍

  • @markfairhurst7078
    @markfairhurst7078 2 года назад +1

    Been waiting for this from yesterday logging on at 6 like where is it then realised it’s sat 😅

  • @richardsedorski1206
    @richardsedorski1206 2 года назад +1

    Nice one good tips.👍👍👍😎😎😎

  • @nickcannon5592
    @nickcannon5592 2 года назад +1

    You know what you were saying about stress, well I been planning a job for a week now and my mate has turned up pissed, still in saturday night clothes. I think my head is going to explode

  • @petereyre5188
    @petereyre5188 2 года назад +1

    Looks beaut mate 👌👌🏴󠁧󠁢󠁥󠁮󠁧󠁿

  • @mikegallagher2107
    @mikegallagher2107 2 года назад +1

    top draw again mark no bullshit real life plumbing im going to installer tuesday so will pop and see you keep up the great content as usual

    • @MJTiffPlumbing
      @MJTiffPlumbing  2 года назад

      Yes mate, be good to catch up buddy🙌🏼🙌🏼👍🏼👍🏼

  • @allandewar
    @allandewar 2 года назад +1

    Sorry to be negative Mark but the heating pump must only be fitted with the pump axle in the horizontal position , Not in the vertical as this will aid overheating.

    • @MJTiffPlumbing
      @MJTiffPlumbing  2 года назад

      Yep, this has been said all ready. Will be sorted as I have to go back this coming week for some bits…

  • @stephencarter6634
    @stephencarter6634 2 года назад +1

    Good stuff 👍

  • @elliottseymour7711
    @elliottseymour7711 2 года назад +1

    Yes marky boy

  • @sandih2o
    @sandih2o 2 года назад +2

    I think you'll have to turn the pump ... it shouldn't be in a position where the rotor is vertical😁😉

  • @SuperWayneyb
    @SuperWayneyb 2 года назад +1

    🤘😎🤘 Evening Mark 🫖☕️🍰

    • @MJTiffPlumbing
      @MJTiffPlumbing  2 года назад +1

      Evening Wayne…… you going to Installer this week mate???

    • @SuperWayneyb
      @SuperWayneyb 2 года назад

      @@MJTiffPlumbing Yes Buddy down there the 3 days hopefully catch up for a brew 🤘😎🤘

  • @shaunwhite2081
    @shaunwhite2081 2 года назад +1

    Wow pump valves that aren't seized or leaking lucky boy

    • @MJTiffPlumbing
      @MJTiffPlumbing  2 года назад

      I know…. I was surprised aswell🤣🤣

  • @paul_my_plumbs_uk
    @paul_my_plumbs_uk 2 года назад

    Tuesday and Thursday rail strike 😢😢

  • @winnieowen4401
    @winnieowen4401 2 года назад +1

    tidy tiling

  • @steveyboyXRP
    @steveyboyXRP 2 года назад +5

    bad practice having pump sitting upwards lol

    • @MJTiffPlumbing
      @MJTiffPlumbing  2 года назад

      lol

    • @tomheal2095
      @tomheal2095 2 года назад +1

      Can you explain why…

    • @steveyboyXRP
      @steveyboyXRP 2 года назад +3

      @@tomheal2095 venting the pump

    • @MJTiffPlumbing
      @MJTiffPlumbing  2 года назад +1

      Interesting…. I’ve heard this a few times, however you have the screw on the top for vent air from the top of the pump.
      Moving it round isn’t an issue as I’m back there soon anyway…. But interested to hear why, genuinely not had an issue having a pump this way when on horizontal pipe. But always open to infomation
      (I replied with “lol” as for some reason you put it at the end of your comment🤷🏼‍♂️)

    • @pb9926
      @pb9926 2 года назад +7

      @@tomheal2095 pumps cause cavitation which allows air to sit in the pump when facing upwards, over time this will limit the life of the pump and burn it out.

  • @carguillo1
    @carguillo1 2 года назад

    HI Mark code wont work

    • @MJTiffPlumbing
      @MJTiffPlumbing  2 года назад

      Working fine here….. just checked it buddy

    • @gkoster99
      @gkoster99 2 года назад

      @@MJTiffPlumbing code doesn't work if you try and buy the WCIL11 you showed. "Sorry, this coupon is not applicable to selected products." Great vid by the way

  • @sesquepedalian3968
    @sesquepedalian3968 6 месяцев назад

    How many ads?

    • @MJTiffPlumbing
      @MJTiffPlumbing  6 месяцев назад +1

      Guess what….. RUclips is free…….. and because of that you have to have ads….
      If you don’t like ads pay for premium…. But you will probably moan about that aswell🙄