Thank you Sir for your amazing videos, I kindly need your consultation; Siemens Analog RTD input module - SM 1231, all channels report / return -32768, even though configured to 3 wire pt100, any advice, please
Thank you for your effort sir! I have a question. I am building a project with the sb 1231 rtd module, after wiring the module what did you use as thermocouple? I mean what type of sensor can I use to detect the temperature of the room? Thank you.
La pregunta es, ¿ha insertado la unidad en su controlador mientras estaba encendido? Si es así, el controlador ya no podrá aceptar más tarjetas SB en esa ranura. Esa parte del PLC se dañará y ya no podrá utilizarse.
Hi Cockun. It wary much depends of what you are using the reading for. For basic set up just to read the temperature on HMI, no not really. But if you want more then just reading, again wary much depend of application, you might need it. This reading quite often is used with PID set ups.
you are my new hero thanks mate
I really wanna thank you for your great great great work, your channel is a treasure
Glad you enjoy it! Thank you for your support.
S7-1200 PLC has 6 HSCs. If i need 4 more HSCs for Single phase counter operations. which Signal board or Signal Module shoulde choose?
Thank you Sir for your amazing videos,
I kindly need your consultation;
Siemens Analog RTD input module - SM 1231, all channels report / return -32768, even though configured to 3 wire pt100,
any advice, please
Thank you for your effort sir! I have a question. I am building a project with the sb 1231 rtd module, after wiring the module what did you use as thermocouple? I mean what type of sensor can I use to detect the temperature of the room? Thank you.
Hola puedes ayudarme con la conexión de una signal board SB 1222 200 khz DQ 4x 5VDC 0.1A.
No la reconoce mi plc s7-12000 dc/dc/rly version .1
La pregunta es, ¿ha insertado la unidad en su controlador mientras estaba encendido? Si es así, el controlador ya no podrá aceptar más tarjetas SB en esa ranura. Esa parte del PLC se dañará y ya no podrá utilizarse.
Thank you for your effort Ingus! I appreciate it. No need to norm and scale the value that we measure then? Cheers!
Hi Cockun. It wary much depends of what you are using the reading for. For basic set up just to read the temperature on HMI, no not really. But if you want more then just reading, again wary much depend of application, you might need it. This reading quite often is used with PID set ups.
Great videos thanks for sharing. Can you show how to connect a profinet device and how to setup telegram. Cheers
Hi Spartan, i will put that on the list to do.
Dear Sir, I would like very much that, if possible, you could make a short video on how to use the 6ES7 241-1CH30-1XB0 (RS 485). Thank you very much!
Hello Julio, yes the video is coming soon, just waiting on bus terminators to come in.
@@IGSElectronics INGUS, thank you so much! You have no idea that will help me about my knowledge! Sorry but my English is not very well!
fantastic sir
Excellent!