Maybe it’s the only video on youtube that explains this principles about the apexl locaters Thx for the valuable information Especially these first and second generations ❤
Hi! Thanks for explaining this! It will be really kind of you if you could provide some clarity on this- Is Ingle's radiographic method of working length determination still valid for digital X-rays? Since digital x-rays are so magnified does the radiographic method still valid?
Hi sir... I use triauto zx endomotor with apex locator.. in some cases it show it reached apex while cutting with rotary files.. after fitting of gp it will show short 4 to 5 mm... It was very disappointed situation.. what may be the cause.. is it fault of rotary files due to wear of file blades??
Hi It's not a fault of rotary files. There can be following reasons for faulty reading in your case - 1. Just check for contact of rotary file to gum or cheeks during preperation. Avoid its contact to gums 2. May be canal is overflooded with irrigant or saliva. Dry the canal before use. 3. Ideally take WL with hand file, then use rotary at that length. 4. Take approximate WL on preoperative IOPAR. It will take you to last 2-3 mm of canal which will help in avoiding faulty reading
Maybe it’s the only video on youtube that explains this principles about the apexl locaters
Thx for the valuable information
Especially these first and second generations ❤
🙏🙏
Great! It is noted most common the anatomical constriction of apex is about 0.5 - 1mm short of radiographic apex
I have rarely seen a clear understanding of Apex locator
Appreciate.
🙏🙏
Great job...am not a dentist but was still able to understand the principles somewhat....
Thankyou 🙏
Hi! Thanks for explaining this! It will be really kind of you if you could provide some clarity on this- Is Ingle's radiographic method of working length determination still valid for digital X-rays? Since digital x-rays are so magnified does the radiographic method still valid?
Ingle's method is still valid👍
Wonderfully explained...highly recommended
Thankyou boss🙏🙏🙏
Thank you so much sir .....it was very easy way to understand apex locators
🙏🙏
Which method should follow for tactile sensation ingles or Grossman? Thankyou dr for this great video
🙏🙏
Short and easy to understand
Nice explaination😊
🙏🙏
A good teacher you are..
🙏🙏🙏
Very helpful, thank you
Sir best dental apex locator for new generation best results
Please suggest me
Sybronendo, j morita
Hi sir..In Epex pro apex locator (from eighteeth), is it safe to obturate at the level of green barcode in apex locator.?
Hello
I never used this apex locator
Beautifully explained 👍
🙏🙏 Thankyou
Hello sir.. please suggest sixth generation Apex locator available in market..I need it for my thesis
No idea as of now. Let me search then I can tell you🙏
@@Endocrisps ok sir!
Is eighteeth any good?
No Idea
Never used
Hi sir... I use triauto zx endomotor with apex locator.. in some cases it show it reached apex while cutting with rotary files.. after fitting of gp it will show short 4 to 5 mm... It was very disappointed situation.. what may be the cause.. is it fault of rotary files due to wear of file blades??
Hi
It's not a fault of rotary files.
There can be following reasons for faulty reading in your case -
1. Just check for contact of rotary file to gum or cheeks during preperation. Avoid its contact to gums
2. May be canal is overflooded with irrigant or saliva. Dry the canal before use.
3. Ideally take WL with hand file, then use rotary at that length.
4. Take approximate WL on preoperative IOPAR. It will take you to last 2-3 mm of canal which will help in avoiding faulty reading
@@Endocrisps k sir .. thanks
Good vedio.. thank you sir
🙏🙏
How is woodpecker apex locator
Better to go for morita as it highly related to accuracy🙏🙏
I hv wpk but it show good results in vital pulp only
Thank you sir 😊
🙏🙏
To all my indian friends. Please invest in a good Apex locator like Morita or apexID by sybronendo
🙏🙏
INVALUABLE !
Thankyou🙏🙏🙏🙏
Lastima que no entienda lo que dice.