छत मे Bent Up Bar कितना लंबा दें? Cranked bar length kitna hota hain | L/4 ya L/3 length of slab in
HTML-код
- Опубликовано: 30 сен 2024
- छत मे Bent Up Bar कितना लंबा दें? Cranked bar length kitna hota hain | L/4 ya L/3 length of slab in
#bentupbarlength #slabcastingdetail #rcc slab #cranked bar length #bent UP bar length kitna dein #crank kitna uthaye #crank ka sahi angle kya hain #civil engineering support
8/10 का कमरा है क्या इसमें क्रैक बीम लगाना जरूरी है
Sir 24/24 house ko kitna kointal.rod.chahihy..slap.keliye
Your teaching skills are so bad
Bahut he ghatiya kaam hua hai 😂😂😂
Kya pakao.... length batane ke liye itna lamba video
Waste time.
Good morning 🌄🌅🌅🌅
Aasan bhasa hamare liye hindi hi hai
jo ans aya wo imch m hoga ya feet m exmaple 15/4 tu 3.75 ab yai inch m hoga ya feet m
Bhai simple hei wo inch pe toh hogi nahi kynki inch hota hi kitna hei... So wo feet mein aayegi... 3feet 7inch
Poultry farm wala awaj lga
सर अगर सिल्याप 19+15 बैंड कितने पर आयेगे
8/21rod budged8mm kitna kharcha hoga
Agar 10x10 ka room ho tu 3t pe bend dena parega ya bend ki length 3ft honi chahye?
2.5 foot or 30 inch pay bent up dain gay
தமிழில் தெளிவாக காட்டவும்
Sir crank ka nicha jo support dena keya ghodi banta hai wo kisa Binta hai
Crengme taprad kese dena he
Crengmetaprad kese dena he
Nice video
Hi
Ulabim kese krego hotahe usapato palethin detehe
Beam ke inner inner se lenghth Lena kya outer outer se
Sir 🙏❤️
Good describe
Sar been ak laen me nahi he to chhat ka loha kese badhe
Pani tenki ka jali k keise banata he
Thanks sir
Beam c/ c L/5
Aap ne ye to bataya hi nahi ki crank bar chhat ki lambai se hi niklna hai ya chaudai se bhi...
Agar slab size 10' x 12' hai to bend length kis side kitna rakhen
Longer span lain gay sir mean 12 feet ka L/4 lain gay
L/5 chalta ky
Sir confidence utna nhi hai
Sirji Slab me bentup bar kiyun dete hain
Kya yeh dena zaroori hai
Nahi diya to kya hoga
Sleb creck hone k chans bd jaenge.
Crenk bar slab ko mjbuti deta h
@@esrafilansari7087 13*19 ka hall hai to man bar l'4 hoga to cross bar kitna jaega
Support pe negative moment ko resist kerny k lye crank bar dya jata hai
Sir meri saja 2.5 feet hai,, without beam, kuch problem hoga kya Sir. Plz advice me.
Nhi 3 feet tk chl jata hidden beam dalkr
good job
Sir
10x10 ke room me Charo taraf se 3,3 feet bent up baar Dena hoga?
30 inch bend one forth
30 inch or 2.5 ft pe bent up dain gay agr clear span of slab 10 foot hai
Extra bar dana jarurui ह kya?
Ha Jaruri hai bhai to Bear the Shear Force .. Mera Channel
Sir column ka size center to center lena h fir L/4 Krna h please reply
Center to center lena rahta he,aur slab length according cranka dena padta he,l/4,5,7 bhi diya jata he
Nice video...
Agar 20× 20 ho to
Then slab two way ho gi and 4 sides say bent up bar provide kerna parhy ga L/4 pay
One way slab me l/3 bhi de sakte hai
Nahi Bhai L/4 Hi thumb rule hai
Thanks
Sir L Bai 7ka bataye
Sir value L/3 to L/7 use ki ja sakti hai
रामू मिस्त्री
😂
Sir kus log L/3 ke hisab se crank lagate he .. ye sahi he ya galat ?
L/4 hota hai 🙏
Ap end support k lye L/4 say L/7 tak use ker sakty hain but normally L/4 hi lya jata hai even ap continuous support pay L/3 b use ker sakty hain
Please send video technically specification and thumb rule for building any item
Md
Why beam exta top not provided?
Sir sleab ke 10 mm stell me L Dena ketna garore he
Slab ma top steel ko agr double mesh ho tou development length or L dena zarori hai for proper bond between steel and concrete
Sir BBS par bhi video banaiye 🙏🙏
Sir mera column to column distance 14 ft aur size h 9/15 ka h aur mera beam size 9/12 h so kya h chhat m 8 mm aur 10 mm ka main aur distubusion m sariya use kar skta hu aur mere ko 4 floor ka plan h
Agr 4 floors bnany hain to apko slab main main bar 12mm and distribution bar 10mm use karna padhy ga with slab thickness minimum 150mm especially for first 3 stories
L5