SCR metering quantity test | Check AdBlue injection valve for reducing agent | VCDS Tutorial

Поделиться
HTML-код
  • Опубликовано: 2 окт 2024
  • The error code 15733 P20EE SCR NOx catalyst effect too low indicates a fault in the SCR system. To determine the cause, an SCR dosage quantity check should be carried out. This checks whether the AdBlue injection valve for reducing agents is working properly. This is a useful test to diagnose and troubleshoot problems with the SCR system. However, it should be noted that the NOx catalyst cannot always be identified as the source of the error.
    The video shows that the AdBlue injection valve does not receive any pressure, although the SCR pump builds up the pressure correctly. You can see this in the measured values.
    Measuring Values:
    IDE03129 Reducing agent
    IDE03131 Reducing agent injector
    IDE03132 Pressure sensor for reducing agent
    IDE03135 Sensor for reducing agent tank temp
    IDE03136 Sensor for reducing agent fill level
    #SCR #AdBlue #VCDS

Комментарии • 8

  • @MadeByAndre1976
    @MadeByAndre1976 8 месяцев назад +2

    Ich habe ein ähnliches Problem und mich interessiert, was die Ursache sein könnte.

    • @diagvids
      @diagvids  8 месяцев назад +1

      Wir haben leider die Fehlersuche abgebrochen. Der weitere Schritt wäre den AdBlue Tank auszubauen und nach der Undichtigkeit zu suchen, weil laut den Messwerteblock liegt am, Sensor der korrekte Druck an.

  • @JamieFosterr-d8x
    @JamieFosterr-d8x 4 месяца назад +1

    Would this be a faulty pump

    • @diagvids
      @diagvids  4 месяца назад +1

      Yes, the pump could be a possible cause. Unfortunately we have stopped troubleshooting. The next step would be to remove the AdBlue tank and carry out the same test as in the video to look for the leak, because according to the measured value block, the sensor has the correct pressure.

  • @charlychlonson8381
    @charlychlonson8381 8 месяцев назад +1

    Lag jetzt der Fehler am Einspritzventil?

    • @diagvids
      @diagvids  8 месяцев назад +3

      Leider nein, aus dem Reduktionsmitteltank (AdBlue) wird kein Druck aufgebaut. Sieht man im Video an der Stelle mit dem Messbecher.
      Fahrzeugbesitzer hat sich für SCR Off entschieden.

    • @charlychlonson8381
      @charlychlonson8381 8 месяцев назад

      @@diagvids Ok, also die Pumpe liefert den nötigen Druck, nur an der Zuleitung des Ventils liegt keiner mehr an. Wird es auch Videos über ADBlue Off geben, reicht da die Entfernung aus dem Motorsteuergerät oder muss da noch anderweitig codiert werden?

    • @diagvids
      @diagvids  8 месяцев назад +3

      @charlychlonson8381 korrekt, der Druck wird laut Sensor aufgebaut geht aber auf der Strecke verloren. „ADBlue off“ wurde beim Chiptuner gemacht. Mir. Fehlt das entsprechende Equipment.