I saw many videos of yours, please share some videos for designing for High velocity and medium velocity sprinkler system and gas suppression system , how can we design , what is the pipe size , nozzle size , gas bottle size and all, Thanks in advance
सर जी , आपका हर वीडियो में महत्वपूर्ण जानकारी मिलती है । सर आपको दिल से धन्यवाद 🙏💐 एक बात पूछनी है कि......सर क्या आपका जितने भी वीडियो है NFPA, NBC, IS के तहत बनता है या आप अपना अनुभव के हिसाब से बनते हैं। कृपा बताने का कष्ट करें।
very informative video but missing abort switch, low pressure switch, discharge pressure switch fire suppression system jiyadatar is tarah kam karte hain 1 smoke detector ya 1zone agar fire detect karta hai to alarm bell on ho jayega , 1stage alarm signal MAIN FIRE ALARM CONTROL PANEL ko jayega sath me BMS , FIRE CONTROL STATION, or FIRE FIGHTER DEPARTMENT ko bhi jayega 2 smoke detector ya 2 zone detect karne par alarm bell, sounder , flasher on honge agar sings lage honge to inside room me door ke upar evacuate ka sing flash karega outside room door ke upar do not enter ka sing flash karega 2nd stage alarm signal MFACP, BMS, FIRE FIGHTER OR FIRE CONTROL STATION ko jayega gas release countdown start ho jayega aur countdown complete hone par gas release ho jayega , gas release hone ke bad DPS active hoga aur control panel ko signal jayega agar false alarm hai to countdown complete hone se pahle abort switch press kar ke hold karenge to gas release nahi hoga jab tak kisi ko panel reset karne bol sakte hain ya maintenance switch se release disable kar sakte hain note - agar soch rahe ki suppression system hai to fire fighters ya fire control station ka kya kaam to wo log aa gar investigation karte hain aur report dete hai ki kis wajah se aag lagi kahan par galti hui etc. wear mask , keep social distance stay safe thanks to all FDAS TECHNICIAN
Dear in the local application system agar aag 2 alag jagah se ignite Hui hai to tube pahli jagah se puncture ho jayega and then dusre spot ka kya solution hai???
Thanks for the nice educative video. Is there any guideline about how tubes to be installed inside electrical panels? Request to revert asap. Thanks in advance.
Bhai fm200 room ke purging button ka bhi pura detail me samjhaye. Because normal conditions me supply and return damper open rahta aur exhaust damper close but jaise hi trouble detect hota hai but purging button ka main work samjhaye
Hello, Thank you for the detail information, it’s a really informative one. Do you have any ebook or pdf file with bullet points? It would be very helpful to me
Fm200 is an extinguishing agent and if you want to know about detector siting and spacing then watch this video.👇 ruclips.net/video/CQpMjJJ-QgU/видео.html
@@FireSafetyAcademyAssalamualikum. Fm -200 mein LPG kya hay. FM -200 mein Hy good kya hay. FM 200 mein Kidde FENWAL kya hay. Sir Fm- 200 mein just FM 200 hei gas hoti hay. Ya Fm 200 mein gas ke koi or bee type hoti hay. Suppression systems cylinder make Brand kya hota hay. Please video or text kr de geyh. FM 200 mein just zeraf one hei type hoti hay.
A Room Integrity Test, also known as a Door Fan Test, is simply a way to measure the leakage of an enclosure where the Fire Suppression System has been installed.
Thanks for the explanation but i observed some observations as working principles of zones, adding many cylinders to a manifold. Is the flooding system will discharge without pre alarm or a single zone, I think for the release the gas system required 2 cross zones.
Very amazing information dear. Mey ap ke Kya help kr skta hu . Mey as a fss engineer duty krta hu moblink or Warid offices mey . Safety course krna ho tu meyre ap Kya help kr skty Hy .
U knw sir i m from commerce my age 26 most people say dont go hse profession when u ll get degree wen u ll start job n ur age ll be 30 at that time .. so dont go this profession.. mostly engineers have preference in this field ..... sumone meet n say dont do n all
Very nice Thanks 👍 welcome sir your video is very well & very easy translation good described so many many thanks Namaskar 🙏🙏 i
Nice sir🎉
Bhut bhut shukrya bro bhut accha smjhaye ho mujhe novec1230 ka janakari chahye tha wo mil gya thanks bro ❤❤❤❤❤❤
Hello
Sirji, Boht helpful information dedi Apne, Thank you so very much. ! Apka smjhane ka tareka boht acha hai, boht detailed tareke se smjh gaya mai.
Very very nice so much define dear sir 💕
Nice Explanation
Best achha smjhaya aapne
Short and simple.... Thank you sir
Never ever seen an explanation like this thank you sir
I was waiting for it for a long time
Very very informative, clear and conceptual presentation. Please continue uploading such rare topics
Great...
Thanks for sharing knowledge...
Thanks a lot for making such a informative video.
Very nice information
Much informative
Great 👍👍
Thanks for sharing the important topic 🙏😃
Bahut he badhiyaa
Thank you
Very helpful
Ultimate video
Do share with your friends 🙂
Thank you sir,
Sir ji, Agar aap clean agent ko fire extinguishers me kaise bhara jaata hai us par ek video bana de to badi meherbani hogi.
Love from Pakistan... Great informative session
Thanks buddy
Huch sulle magane hogu elli yaka edi india valage
Excellent information provided sir... amazing
Thank you brother 😊👍
Very nice sir
I saw many videos of yours, please share some videos for designing for High velocity and medium velocity sprinkler system and gas suppression system , how can we design , what is the pipe size , nozzle size , gas bottle size and all, Thanks in advance
सर जी ,
आपका हर वीडियो में महत्वपूर्ण जानकारी मिलती है ।
सर आपको दिल से धन्यवाद 🙏💐
एक बात पूछनी है कि......सर क्या आपका जितने भी वीडियो है NFPA, NBC, IS के तहत बनता है या आप अपना अनुभव के हिसाब से बनते हैं।
कृपा बताने का कष्ट करें।
Kisi bhi topic ko achhe se explain karne ke liye experience jaruri hota hai sath hi standards ko bhi dhyan me rkhna pdta hai.
@@FireSafetyAcademy बहोत बहोत धन्यवाद सर 🙏
very informative video
but missing abort switch, low pressure switch, discharge pressure switch
fire suppression system jiyadatar is tarah kam karte hain
1 smoke detector ya 1zone agar fire detect karta hai to alarm bell on ho jayega , 1stage alarm signal MAIN FIRE ALARM CONTROL PANEL ko jayega sath me BMS , FIRE CONTROL STATION, or FIRE FIGHTER DEPARTMENT ko bhi jayega
2 smoke detector ya 2 zone detect karne par alarm bell, sounder , flasher on honge agar sings lage honge to inside room me door ke upar evacuate ka sing flash karega outside room door ke upar do not enter ka sing flash karega
2nd stage alarm signal MFACP, BMS, FIRE FIGHTER OR FIRE CONTROL STATION ko jayega
gas release countdown start ho jayega aur countdown complete hone par gas release ho jayega , gas release hone ke bad DPS active hoga aur control panel ko signal jayega
agar false alarm hai to countdown complete hone se pahle abort switch press kar ke hold karenge to gas release nahi hoga jab tak kisi ko panel reset karne bol sakte hain ya maintenance switch se release disable kar sakte hain
note - agar soch rahe ki suppression system hai to fire fighters ya fire control station ka kya kaam to wo log aa gar investigation karte hain aur report dete hai ki kis wajah se aag lagi kahan par galti hui etc.
wear mask , keep social distance stay safe thanks to all FDAS TECHNICIAN
Welldone SIR
AWESOME
Thanks
V 👍good
Very nicely explained brother.
Keep watching
Dear in the local application system agar aag 2 alag jagah se ignite Hui hai to tube pahli jagah se puncture ho jayega and then dusre spot ka kya solution hai???
Can you please share the temperature of fire suppression system activation
thanks sir nice video
Sir, Kindly explain about Room integrity test
Great learning experience
Can you guide how I can do the testing after completely installing the novec gas suppression system.
Which agent is very lowest budget for 2*4*6 feet electric cabinet and easily we can refill at our shop.
Your Explanation is Really fantastic.... Thank you bro..
Thanks 😊
very nice
FM 200 and co2 gass suppression systeem are same or deffreant?
Nice explanation. Could u also share design calculation sheet in excel & explain how to design by giving am example. It will be very useful.
Super 😚❤️🌹👍
Very nice sir thank for share wonderful video .request to u next time plz Mentione the cost of all types agent
Hello sir, Were looking for Fire suppression system installation engineer. Do u know anyome who would lile to join
Nice video
Super sir
Seamless pipe or M. S. Heavy pipe use kere . Tell me please.
Nice information sir .what is cast for electrical panel board
Thanks for the nice educative video.
Is there any guideline about how tubes to be installed inside electrical panels?
Request to revert asap. Thanks in advance.
Sir diff between fm 200, novec 1230, naf s125 ki ek video banaeye
Bhai fm200 room ke purging button ka bhi pura detail me samjhaye. Because normal conditions me supply and return damper open rahta aur exhaust damper close but jaise hi trouble detect hota hai but purging button ka main work samjhaye
hvwss our mvwss ka lpm kitna hota hai Sir
What is solid propellant gas generators
Please make a video on fire extinguisher testing pressure and hydrostatic, bursting pressure
ruclips.net/p/PLL9dWTk0vXCkGOyyPe97uOlT7F1m5zJZW
sir iske installation ke liye calculation kaise krte hai plz is pe ek video bnaye.
My dear please share immediately their procedure in large way when fire break out
Hello,
Thank you for the detail information, it’s a really informative one. Do you have any ebook or pdf file with bullet points? It would be very helpful to me
Difference between IG100, FM200 and Novek 1230 fire suppression system. Which one is most suitable?
*sov ka baad sv and ps use hota hai wo kis kam k liye wo to batao*
Kitne type ka supresion system hota can u tell me
Aap suppression methods ke bare me janna chahte hai ya agents? agents ke bare me video me sb cover kiya hua hai 👍
What is the coverage area of fm200 smoke & heat detector?? & what should be the distance between two smoke or heat detector for installation...
Fm200 is an extinguishing agent and if you want to know about detector siting and spacing then watch this video.👇
ruclips.net/video/CQpMjJJ-QgU/видео.html
can we made it as a science project
And size of pipe 25mm dia. or 15mm dia. And 50mm dia. For Manifold. Tell me please
nice session sir ji .... sir fire opretor fire inspector previous exam ke pdf provide kara sakte he .... thanks again😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊
Previous exam ke to nahi h
Sir FM 200 ka koi full form hota hai ya yeh gas ka naam hai..Aur Fire Alarm control panel aur abort switch ke bare video bana sakte hai
Nahi eska koi full form nhi hota hai but jo gas use hoti hai use Heptafluoropropane bolte hai.
Fire panel par video jaldi hi aa jayegi. Thanks 👍
@@FireSafetyAcademy .. Thanks a million sir
@@FireSafetyAcademyAssalamualikum.
Fm -200 mein LPG kya hay.
FM -200 mein Hy good kya hay.
FM 200 mein Kidde FENWAL kya hay.
Sir Fm- 200 mein just FM 200 hei gas hoti hay. Ya Fm 200 mein gas ke koi or bee type hoti hay. Suppression systems cylinder make Brand kya hota hay. Please video or text kr de geyh. FM 200 mein just zeraf one hei type hoti hay.
Pl tell us how to design, how much gas required, in what time,
This is done majorly by Vendor as per Contractor and clients design requirements.
Koi bhi bata sakta hai muje ke ae fm 200 ka full form or usme konsa media use hota hai
sir, what is room integrity test
A Room Integrity Test, also known as a Door Fan Test, is simply a way to measure the leakage of an enclosure where the Fire Suppression System has been installed.
Multiple hazardous area can be covered in one system or need separate system for each area?
You can cover area considering your cylinder bank capacity.
Thanks for the explanation but i observed some observations as working principles of zones, adding many cylinders to a manifold. Is the flooding system will discharge without pre alarm or a single zone, I think for the release the gas system required 2 cross zones.
There are two phases in suppression system one is pre alarm and second is main alarm/release.
Very amazing information dear. Mey ap ke Kya help kr skta hu . Mey as a fss engineer duty krta hu moblink or Warid offices mey . Safety course krna ho tu meyre ap Kya help kr skty Hy .
Dost meri smjh me nahi aaya ki aap help karne ki baat kar rhe ho ya fir aapko help chahiye? 🤔
@@FireSafetyAcademy ap muj feather guidelines Dy duo k agy mey seft mey kis course mey admission lu .
@@FireSafetyAcademy ap my Jo vide information de thi completely seen ke tu muj zaberdast lgi thi video q k mey is activity ko daily report krta hu.
मैं अपने ऑफिस में CO2 गैस सप्रेशन सिस्टम लगाना चाहता हूं, इसका खर्च समझाएं
sir es video ki pdf notes mil saktay h plz sir
Sorry not available
Mai fire fighting technician ka kam kar Raha hun sir apke institute ka certificate milega mai Dubai me hun
Ye koi institute nahi hai sir 😊 sirf RUclips Channel hai 👍
Pls contact us by 8408855000
Novec 1230 k bare me batye full ditail operating k bare me or konsi gas hoti hai cylinder wo bataye
Shayad aapne video pura nahi dekha maine btaya hua h Novec 1230 ke bare me
Aur jitne bhi suppression system hote h sbka working principle lagbhag ek jaisa hi hota h 👍
U knw sir i m from commerce my age 26 most people say dont go hse profession when u ll get degree wen u ll start job n ur age ll be 30 at that time ..
so dont go this profession..
mostly engineers have preference in this field .....
sumone meet n say dont do n all
Sir if you are planning for Engineering then definitely it will take 4 yrs but if u go for short term courses then u can complete it in a year.
Very nice Thanks 👍 welcome sir your video is very well & very easy translation good described so many many thanks Namaskar 🙏🙏 🙏