FM200 FM200 Gas Suppression System | Installation & Working in Hindi
HTML-код
- Опубликовано: 6 фев 2025
- FM200 Gas Suppression System
In this video you can learn what is FM200 System & how its work.
FM200 is a Gas Suppression system which is installed in critical rooms like server, Hub, UPS, Electrical etc.
FM-200 Gas name is Heptafluoropropane.
For more such video please subscribe my channel "Ansari29".
Last Video's link available below
---How to Design Conventional Fire Alarm System (Hindi)
• How to Design Conventi...
---Ground Fault & Troubleshooting in Fire Alarm System in Hindi
• Ground Fault & Trouble...
---Fault & Troubleshooting in Fire Alarm System in Hindi (Part 1)
• Fault & Troubleshootin...
---Conventional Fire Alarm System (Explanation in Hindi)
• Conventional Fire Alar...
--------------------------------------------------------------------------------------
#FM200system
#FM200installation
#FM200working
Very nice video ansari ji
Thanks for your comment 🙂
I like ur all videos
@@abdulzoha5972 thanks for your comment 🙂
You have to use a world wide language
Classical demo. Your all videos are marvelous. Please carry on.
बहुत अच्छी जानकारी दी. बहोत बहोत शुक्रिया 🙏🙏🙏
Thanks
Sir nice video.... Aap bohat achha explain karte hain..
Thanks Ishtiyaq 😊
Excellent work 💯
Thank you! Cheers!
I'm from Pakistan thanks brother to explain this system 👍👍
Most welcome
Thank you sir, short speech me bahut acchya samjaya.
Thanks
Ek number bhai 👌
ruclips.net/video/t1RLfdKJOg4/видео.html
Thanks sir ،I have learn many things from you r video ،
It's my pleasure, pls share my videos in your company groups
Can the Room pressure venting into adjacent escape corridor?
Very supportive video Ansari sir
Lekin kya aap Hfc227ea k bare me explain kar sakte hain?
Thanks for your comment 😊
Hfc227ea is also called as FM200 system
Superb detailed bhai
Thank you so much 😀
Dear sir mujhe aapke videos se bhaut knowledge mila h but now aap programming kasee krte via software ye mujhe btye because m dubai ja rha hu programming main mujhe aapki help ki zarurt h aap ek video bnyee programming se related aur mujhe tag kre request h
hi have any video on co2 suppression system
Not yet, but i will try to make videos on said topic
Amazing demonstration
Hello Mr Ansar. Can you check that I think in FM 200 we cannot use heat detector. Heat detector starts working after 57 degree temperature. To protect the equipment in server room it is important to ensure that the temperature does not exceed 20 degree.
I think in FM 200 only smoke DETECTOR we can use.
Aapky doubt ka video upload hogaya hai. Pls check karlo.
Thank you ❤
Excellent work
Thanks for your comment 😊
Pls share my videos in your company group
EXCELLENT
👍
Thanks for your comments, pls share my video in your company group
Thnaks a lot sir
Most welcome.
Pls share my videos in your company group
Insha Allah sir why not ☺️☺️
Very nice 👍
Thanks, please share my videos in your company group
Vai bahott assa vedio bania.
Thanks for your comment 😊
Sir cctv pi b video bana do
Yes sure
Nice explanation
Thanks, pls share my video in your company group
Sir I don't any job 😒 I will attend 2 3 company intrw but no reply I have 5 year experience
@@mskvideo8950 kaha rehty ho aap...
India me Mangalore
Sir aap ka coaching center kaha par hai
I am only available on RUclips
@Ansari29 Where is its coaching center
Hi i have one question how to connect yellow BGU connection when I press the bgu it’s not triggering can you please clarify my dought
BGU...???
Sir fire fighting me kitchen hood ke bare me jankari chahiye ki kitchen hood ka piping kaise karate hai please sir very argent Hai
Bhai fult ke bare me bataye
Video uploaded pls subscribe & press bell icon for notifications
Thanks for sharing such useful details.!
My pleasure 😊
Thanks a lot for sharing knowledge can u pleas explain more abort switch
FM200 PPM Video
ruclips.net/video/t1RLfdKJOg4/видео.html
🔥Water Leak Detection System Testing & PPM🔥
ruclips.net/video/AI9e8yle8WE/видео.html
Very nice sir thanks
How to operate FM 200 in case of power failure?
Always remember, Fire panel & FM200 CCTV IBMS system is powered from UPS supply. So in case of power failure it will work, also panel have battery backup.
Agr aik smoke e active o t phr Kiya o ga
Only fire show hoga but system activate nhi hoga
Tnx bro
Dear ansari can you explain the novec SOV connection and relay connection Ravel RE 120 GR
Don't worry ek video banaduga ispy
Very very nice
Very well explained sir.
Thanks dear 😊
FM200 PPM Video
ruclips.net/video/t1RLfdKJOg4/видео.html
Water Leak Detection System
ruclips.net/video/Y4ZeFd9T4Jk/видео.html
🔥Water Leak Detection System Testing & PPM🔥
ruclips.net/video/AI9e8yle8WE/видео.html
FM200 Gas Release Panel Commissioning
ruclips.net/video/RaWbIHt-kTk/видео.html
Very nice
Thanks, pls share my videos in your company group
sir thoda gas release panel k bary m bhi video banao
ok thanks
ruclips.net/video/TuDW5DcGA2A/видео.html
FM200 PPM Video
ruclips.net/video/t1RLfdKJOg4/видео.html
🔥Water Leak Detection System Testing & PPM🔥
ruclips.net/video/AI9e8yle8WE/видео.html
Dear can you please make a video on fire guard conventional panel cabling & termination of the panel...
Yes bhai,
Zaroor banaoga but abhi thoda busy schedule hony ki waja sy video upload nhi kr pa raha ho
But inshallah zaroor banaoga
@@Ansari29 ok koi baat nhi
Thank you sir..
Thanks for your comment 😊
Hii sir this is me from banglore
I started New business so i want man power works and metal can answer any....
For a 6.5X5.5X3.5 cu.m room, what size NO2 cylinder required and what should be the pipe dia?
Please check my FM200 designing video. You can calculate easily.
Addressable panel buliding zone vice alarm haisha thenaka vidieo sir
Yes sure
Thanks for your comments 🙂
Please check my all video
NOVEC mein konsa gas used hota hai?
A fluorinated ketone containing carbon, fluorine, and oxygen used in novec system
Bro can you tell me your company name?
Excellent ❤️
Thanks for your comment
FM200 PPM Video
ruclips.net/video/t1RLfdKJOg4/видео.html
Water Leak Detection System
ruclips.net/video/Y4ZeFd9T4Jk/видео.html
🔥Water Leak Detection System Testing & PPM🔥
ruclips.net/video/AI9e8yle8WE/видео.html
FM200 Gas Release Panel Commissioning
ruclips.net/video/RaWbIHt-kTk/видео.html
Nice sir
Thank you
FM200 PPM Video
ruclips.net/video/t1RLfdKJOg4/видео.html
Water Leak Detection System
ruclips.net/video/Y4ZeFd9T4Jk/видео.html
🔥Water Leak Detection System Testing & PPM🔥
ruclips.net/video/AI9e8yle8WE/видео.html
FM200 Gas Release Panel Commissioning
ruclips.net/video/RaWbIHt-kTk/видео.html
Lovely
FM200 PPM Video
ruclips.net/video/t1RLfdKJOg4/видео.html
Manual release manual abort difference
MR - Solenoid valve activate hojayega or gas release ho jayegi
MA - Timer stopped hojayega
@@Ansari29 thanks for reply
Hi, how much pressure in the fm 200 Cylnder?
360 psi & range is 300 psi to 400 psi
nice
Thanks for your comment
FM200 PPM Video
ruclips.net/video/t1RLfdKJOg4/видео.html
What is the function in fm200 system stage 1&2... Shield panel
May be user & engineering menu
Where are you located ?
From India
FM200 PPM Video
ruclips.net/video/t1RLfdKJOg4/видео.html
Panal despalsement problem how to sloved
Not getting your question..
Nice
FM200 PPM Video
ruclips.net/video/t1RLfdKJOg4/видео.html
🔥Water Leak Detection System Testing & PPM🔥
ruclips.net/video/AI9e8yle8WE/видео.html
FM200 Gas Release Panel Commissioning
ruclips.net/video/RaWbIHt-kTk/видео.html
Nice
Do you have English translations for the same videos
I will try to add English subtitles in my videos very soon
Why do you limit your videos when you make them in Hindi language only, u have to put words for English
Timer kitne seconds ka hota hai?
60 or 120 sec
All panel same seconds
i need software program
Sir fm200 panel addressable panel me vi connect korsaktahe motlob ap jo video diya usme conventional panel ka sat connect kiya,me nehi samga
Yes, through Monitor module u can integrate it.
FM 200 kaun supply karta he
Kitchen fire suppression system temo sent
You did not show timer delay in video clip.
Thanks for your comment
I will make one more video on this..
Will definitely show in that
Please check at 1:20
@@Ansari29 Thanks sir.
ruclips.net/video/t1RLfdKJOg4/видео.html
Sir how I may contact you?
Ansari29@gmail.com
I don't agree with you about cross zoning method actually here is no combination of heat & smoke it should be either of both smoke detector or heat detector
If zone1 have one smoke detector & zone2 have also one smoke detector so activating of countdown each detector of zone1 & zone2 must be activate then countdown will start ...it does not need one smoke detector & one heat detector both should be either of smoke or heat only...
Thanks for your comment & sharing info
Compelet bana do CCTV pi
Can you explain what is the coverage area of fm200 smoke or heat detector of kiddr system ?? & what should be the coverage distance between two smoke or heat detector ??
Please check this video for detector spacing.
ruclips.net/video/grKPupj1tEw/видео.html
aap apna contact no.dijia
If you have any doubt, please write on comment box.
Muje siex Fm 200 ka installation k lia kuch puchna h
Iska working thoda sa different hai
Ismai ek pilot cylinder use karty hai for multiple bank of cylinder, actually FM200 m bhi pilot cylinder use karty hai jub 5 sy zyda cylinder use hota for boosting.
Siex m hum log ye decide kar sakty hai like konsy room m gas ko extinguish karara hai control panel ki help sy....
FM200 PPM Video
ruclips.net/video/t1RLfdKJOg4/видео.html
NICE SIR
Thanks and welcome
Excellent explanation.
Verry good
Thank you
Nice
Thanks for your comments, pls share my videos in your company group
Nice
Thanks
Nice
Thanks