Depth of Footing And Reinforcement Details for 2 Storey Buiding
HTML-код
- Опубликовано: 8 июл 2021
- 1) Construction cost of 1000 square feet House 2019? Cost of House Construction per square foot 2019
• Construction cost of 1...
2) Grade Of Concrete and water Cement Ratio
• Grade Of Concrete and ...
3) How to calculate Cement, Sand, and Aggregate for M20 concrete
• How to calculate Cemen...
4) Depth of Footing/Foundation and Reinforcement details in Foundation
• Depth of Footing/Found...
5) Maximum distance between two RCC columns?
• Maximum distance betwe...
6) Big Mistakes in RCC Slab - Lapping Mistakes
• Big Mistakes in RCC Sl...
play Lists :
Construction Videos :
• How to Chose Good Qual...
Construction Site Visit :
• New Exterior Design fo...
House Planning Play List :
• How to Study Column wi...
#CivilEngineers #CivilEngineering
Brilliant! Thank you again for sharing this video. Greetings from Papua New Guinea.
I'm learning alot here✊✊
Love♥️ from Nepal 🇳🇵
Good but appreciate if you use the America metric systems for your explanation
I have watched nearly all your tutorials and I want to thank you as I have learned a lot. My house is a single storey but half of it seats on lower level which the lower level is supported by 7 footings (and columns) and a load bearing wall. The clear height of the columns to the beam above is 1.75 m. My question is whether part of the footings can be exposed (not under ground but above the ground level).
I need the Foundation & Column Design of a 5-storied residential Building
Very detailed, thx you Bro.
Just seeing this! I didn’t do German floor for my two storey building, hope no problem and my first decken was very tick what can I do before laying blocks?
Hi sir clay soil minimum footing details
Excellent videos
You are very good 👍
Nice
You did not mention about the p c c concrete under the pit, why
Thank You Sir.
Great 👍
thank you
Footings for G + 3 Please Give your link.?
What about plinth & floor beam with blocks walls?
Less than 15ft will it be ok? Like 11ft,12ft
Dear Sir,
Why hooks are provided in mesh.Please give details
Sir , how can one detaining to find out the size of foothings by the size of coloum
design a rc footing for column size 400×400 mm which carries a maximum load of 800kn, sbc of soil 200kn/m^2 .if one side of footing is to be restricted to 1.50mt. use m20 grade os concrete and fe415 steel
Sir what it means if one side of footing is restricted to 1.5 meters??
Reply
Size of steel bar for mess footing
G+2+roofing commercial building please
What is the actual depth of plinth and ventilator?.... Can you please answer this question?...
Wait for next video
@@CivilEngineerss : ok
Hi