Sir please reply mere colum ki duri 16, feet he or colum size 9/12 he or 16 mm ke 4 road 4 road 12 mm ki to sir latak beam kite e inch ki honi chahiye or g+2 Ghar bansakta he
Sir mere total ghar k construction m 20 column h aur front k room m jo 4 column h unke bich ka distance 19'6" hai. Aur piche k room mai 2 column ka distance 18'6" hai.baki h column m. 10 ft, 12 feet tk h. Aur column 9×14 ke h. Aur steel bar 6 h. 16 mm ke 4 aur 12 mm ke 2.tho sir m G+2 bna skta hu.sir structure mai koyi problem tho nhi h. Plinth beam 9×18 ka rkha hai.Plz guide sir🙏🙏🙏
Ha ye bahut sahi hai G+2 makan ke liye, easily bnaye, 19'-6" or 18'-6" wale column ke bich latak beam 14" ka dena hoga jisme 5" chat ke sath dhalai hoga or baki 9" ka latak niche rahega
Sir please reply mere colum ki duri 16, feet he or colum size 9/12 he or 16 mm ke 4 road 4 road 12 mm ki to sir latak beam kite e inch ki honi chahiye or g+2 Ghar bansakta he
Sir mere ghr ka front 27 feet ka hai... Kya hm 14*14 inch ke 2 pillar pe.. 24 inch lintern beam pe rok sakten hain?
Sir G+3 Building mei 30×15 (front 30) piller ka size kiya rehga..
Sir purana ETAA (Use block) jo nikla hua hai house say usko new construction may use kar saktay hai wall may ,please reply me thank you sir
Concrete block ka aap reuse kar sakte hai lekin jo crack ya Tut gya ho waisi block use na kare
Sir mera ghar ban chuka h lekin aage varandah nhi h. 30 feet ka varandah banana h. Kewal 4 Pilar pe aur chat (roof).. Ban jayega
Ha ban jaega latak beam 18 inch ka de dijiyega
Sir mere total ghar k construction m 20 column h aur front k room m jo 4 column h unke bich ka distance 19'6" hai. Aur piche k room mai 2 column ka distance 18'6" hai.baki h column m. 10 ft, 12 feet tk h. Aur column 9×14 ke h. Aur steel bar 6 h. 16 mm ke 4 aur 12 mm ke 2.tho sir m G+2 bna skta hu.sir structure mai koyi problem tho nhi h. Plinth beam 9×18 ka rkha hai.Plz guide sir🙏🙏🙏
Ha ye bahut sahi hai G+2 makan ke liye, easily bnaye,
19'-6" or 18'-6" wale column ke bich latak beam 14" ka dena hoga jisme 5" chat ke sath dhalai hoga or baki 9" ka latak niche rahega
9*18 lie ring ka size kya h bhai
Sir roof ka sariya bandh kar video daliyega please
ruclips.net/video/40-6cWiOoXw/видео.html
Roof ka sariya ka details dekhne ke liye ye video dekhiye
गलत तरीके
सर अपने पिलर की दूरी 30 फिट बताई गई है मगर आने वाला बिंम जो हो गा उसमें 20, 25, 30 mm इनमेसे कोनसी सलि इस्तेमाल करे ये नहीं बताया. धन्यवाद 🙏
सर 30/25 फिट के दूरी पर कितने इंच का पिलर लगवाउं?
Minimum 9inch x 18inch or maximum 12inch x 18inch