Welding, Lapping, Coupling of Reinforcement in Column and Slab - Which is Best

Поделиться
HTML-код
  • Опубликовано: 30 сен 2024
  • What To do if Lap in Column Comes in Zone A
    • What To do if Lap in ...
    Which Bar should be Staggered during lapping in Column? | Upper or Lower
    • Which Bar should be JO...
    Reinforcement lapping Zone as per IS Code 13920 in Column
    • Reinforcement lapping ...
    In this video, I am going to teach you Welding, Lapping, Coupling of Reinforcement in Column and Slab - Which is Best
    #CivilEngineering #Welding #Lapping #Couplor #Reinforcement #Column #Slab #HouseConstruction #LearningTechnology
    ✔ Official Website in English
    www.learningte...
    ✔ Official Website in Hindi
    www.civiloffic...
    ****************************************************************
    ABOUT CHANNEL
    ✔L & T - Learning Technology: This channel contains Technical Lectures on "Civil Engineering Topics like BBS (Bar Bending Schedule), Quantity Estimate, Rate Analysis, Surveying, Billing Estimate, House Construction, Civil Engineering Interview Question and Answer, Civil Site Related Videos, How to Read Civil Engineering Drawing, Building Estimate, Metro Rail Construction, Basic Civil Engineering Knowledge, Civil Engineering Softwares " from Personal Field Experience by Civil Engineer Mukesh Sah.
    CONTACT DETAILS
    ✔Email Id for Business Enquiry - civilengineeringofficial@gmail.com
    ✔Twitter: / themukeshsah
    ✔Facebook Page: / learningtechnologyoffi...
    ✔ Linkedin: / civilengineermukeshsah
    ✔Instagram: / learningtechnologyoffi...
    ✔Pinterest: / learningtechnologyoffi...
    ✔Tumblr: / civilengineermukeshsah
    Disclaimer:-
    Copyright Disclaimer under section 107 of the Copyright Act of 1976, allowance is made for “fair use” for purposes such as criticism, comment, news reporting, teaching, scholarship, education and research. Fair use is a use permitted by copyright statute that might otherwise be infringing.

Комментарии • 1,1 тыс.

  • @Ameetk369
    @Ameetk369 4 года назад +11

    sach me mahesh bhai apke jaisa detail me koi nahi samjhata youtube pe... kyunki bahot sare log hai jo chanel chalate hai lekin itna detail me koi nahi jata...
    bahot log sirf basic me ya defination me lipta dete hai magar apki video sab ke liye sikhne jaisi hoti hai... mai har video dekhta hoon aur samajhta hoon...
    kyuki mai infra me kam karta ho to mujhe bhi kayi sari problems aati hai magar apke video se problem solve hoti hai...
    so pls keep doin these videos ...
    makn ek suggestion dena chahunga ke ho sake to residential ke sath me infra ke components ke upar bhi video banayiye bahot acha hoga...👍👍👍👍

  • @SohanLal-ci3gx
    @SohanLal-ci3gx 3 года назад +23

    Overlapping provides proper compressive strength in vertical members if laping length is proper.Coupler joints make members in situation but not stand for strength , rebar and coupler bonding may not yield.

  • @samj923
    @samj923 3 года назад +23

    Welding in image is worst and wrong construction.. Lapping is the correct procedure to increase height

  • @suryakumar3380
    @suryakumar3380 Год назад +1

    Sir column 9×12 inches ka column hai jise me 12 mm & 16 mm ka tmt rod hai to Coupling used ker skte hai ...

  • @borntoride2209
    @borntoride2209 3 года назад +11

    lapping is best because cost is not important than life of people.. lapping has given instructions in is codes 50d for slab , 24 to 40 d for coloumn , for beam tension 45d, compression 24d and the distance center to center of lapping length should be 1.3 times of lapp length

  • @ManishPuri
    @ManishPuri 3 года назад +2

    NYC bro

  • @sanjaysrivastav3333
    @sanjaysrivastav3333 3 года назад +14

    Lapping is best. Coupling is very careful work and it needs skilled worker and sincere supervision.
    Needs threading which will take extra cost. So work may be delayed.
    More need of coupling is best for complete load transfer without eccentricity.

  • @ManishPuri
    @ManishPuri 3 года назад +2

    Good information bro

  • @ajayhaldwani5850
    @ajayhaldwani5850 3 года назад +4

    Coupling available hai market main sir best idea coupling

  • @ravip-ss2fm
    @ravip-ss2fm 3 года назад +2

    """ Better, LAPPING, 99% ***
    Ravi,
    Civil Supervisor,

  • @maheshj660
    @maheshj660 4 года назад +7

    Sir ,
    In case coupler joint came in beam junction or slab area is technically wrong ???

  • @ImranSharif-z3t
    @ImranSharif-z3t 5 месяцев назад +1

    number one is lapping and the second option is coupler, welding not accepted

  • @abhikhatri5414
    @abhikhatri5414 3 года назад +5

    Coupling is recommended for column and lapping is recommended for beam but not coupling and also welding is not recommended for either of ...

  • @Aq-yx4ph
    @Aq-yx4ph 3 года назад +1

    Lapping kr k saath Mai welding b krlo zyda mazboot hogjaye

  • @rurutarkar8203
    @rurutarkar8203 4 года назад +3

    क्या सभी साइज की स्टील मैं कपलर use kr सकते है ????

  • @satyampathak9764
    @satyampathak9764 3 года назад +2

    Thank you sir

  • @jaydevmandal4416
    @jaydevmandal4416 3 года назад +4

    Coupling is best

  • @joseph-cy9mo
    @joseph-cy9mo Год назад +1

    I can said that Lapping i the best from my 9years experience

  • @faheemahmad945
    @faheemahmad945 3 года назад +4

    I hope lapping is best for safety

  • @saralbhakti6179
    @saralbhakti6179 2 года назад +2

    Lapping

  • @rahilshaikh439
    @rahilshaikh439 4 года назад +3

    Sir cupling best option hain you right and thanks

  • @princealok7046
    @princealok7046 2 года назад +1

    Coupling is not bring into practice everyvhere

  • @janardhanreddybanala3778
    @janardhanreddybanala3778 4 года назад +24

    Vertical bars coupling is ok what about horizontal bars coupling is acceptable or not ?

    • @vijaykumhar9403
      @vijaykumhar9403 4 года назад +2

      Good question

    • @Amit-yb4sd
      @Amit-yb4sd 4 года назад

      Sir for horizontal joints lapping is recommended

    • @janardhanreddybanala3778
      @janardhanreddybanala3778 4 года назад

      Amit thank you 🙏🏻

    • @Amit-yb4sd
      @Amit-yb4sd 4 года назад +1

      @@janardhanreddybanala3778 sir lapping for horizontal bars can be done only in columns, other than column, lapping cannot be done in the middle of the beams, so couplers dont work ...

    • @brijeshsharma4325
      @brijeshsharma4325 4 года назад

      Yes gud question

  • @ImranSharif-z3t
    @ImranSharif-z3t 5 месяцев назад +1

    very nice explanation keep it up. regards

  • @mr.moktanvlog2753
    @mr.moktanvlog2753 4 года назад +22

    Over lapping is commonly used in building construction.
    So in my opinion lapping is best to transfer the load one bar to another bar

  • @muhammadusama5584
    @muhammadusama5584 4 года назад +2

    Sir amazing informative video thank you sir
    😊😊😊😊😊👍👍👍👍👍👍❤❤❤❤❤❤❤❤❤💕💕💕💕💕💕💕💕💕💕💕

  • @skumar1014
    @skumar1014 4 года назад +8

    In your next video-
    1. Explain cost advantages of handling of heavier bars due to lapping, cost of additional handling due to threading machine.
    2. Cost of threading machine, Cost of threading per bar and productivity of machine
    3. Labour cost savings if couplers are used

  • @BahujanCentre
    @BahujanCentre 3 года назад +1

    Really nice video kya aap ka mobile number mil jayega

  • @taringsanjay9846
    @taringsanjay9846 3 года назад +3

    Make a vedio on estimated comparison on this top

  • @ShyamPrasad-A-Love-S
    @ShyamPrasad-A-Love-S Год назад +1

    So super very nice video 👌❤️🌹👍

  • @shyamchaudhary.3359
    @shyamchaudhary.3359 3 года назад +3

    We are using lapping , in coupler use less steel but lapping is best, more stronger than coupler....

  • @pixl_gaming6667
    @pixl_gaming6667 2 года назад +1

    Coupling is the best way

  • @yashaggarwal7105
    @yashaggarwal7105 2 года назад +3

    Coupling may be good for column/pillar but not for horizontal beams

  • @mrramprakashrajak3343
    @mrramprakashrajak3343 2 года назад +2

    Good sir

  • @raushankumarjaisiriram8188
    @raushankumarjaisiriram8188 3 года назад +3

    सर रड में गुना के लिए बताएं,,👍👍

  • @jagdishpatil453
    @jagdishpatil453 2 года назад +1

    Sir mere area me ye coupling nahi mili mane wire rop coupling se join kar rah hu kya sahi hai trika

  • @nakulakoushalya6976
    @nakulakoushalya6976 4 года назад +4

    Lapping is right

  • @vijayrao5281
    @vijayrao5281 2 года назад +1

    I have a problem, we have a house where the column rods have been protruding from the roof for over 16years now we plan on construction of 2nd floor. Problem is one of the rod coming from the roof is cut and for that section can we do coupling , the bar dia is 16mm

    • @millokimay3962
      @millokimay3962 2 месяца назад

      Same here....I am too searching for this solution.
      Request,bro if U find some solution plz let me know.

  • @jaimabharti9182
    @jaimabharti9182 3 года назад +49

    Lapping is best.

  • @easymake5453
    @easymake5453 2 года назад +1

    Hy sir me swimming pool and faunten kam karta hu

  • @tangrensangma6200
    @tangrensangma6200 4 года назад +3

    Coupling is better than laping and welding.

    • @asuwish8300
      @asuwish8300 3 года назад

      No bro in some conditions lapping is good option. And welding is wrost thing don't apply welding in any condition.

  • @vertexmalakar
    @vertexmalakar 10 месяцев назад +1

    Thermite welding best hain .

  • @borntoride2209
    @borntoride2209 3 года назад +5

    nice video brother good coupling is also good it reduces cost but i cant feel safe

  • @abhisekbabu4968
    @abhisekbabu4968 3 года назад +2

    Coupling mai jo use hota hai bich mai woo idhar milta hi nai hai.. Iss liye hum lapping use karte hai.. Woo coupling joint kah milta hai..

  • @pravinshaha5475
    @pravinshaha5475 2 года назад +6

    Coupling is the best 👍 as per my 45 years experience in Mega Engineering Structure
    Pravin Shaha, Chartered Engineer and Government Approved Valuers

  • @manojkumarpandey1091
    @manojkumarpandey1091 Год назад +1

    Sir ji please bataye... Coupling purchase karna hai...kahailega.

  • @ArchiDesignHub
    @ArchiDesignHub 4 года назад +3

    Lapping, ❤❤💯

  • @ajitkumarray9752
    @ajitkumarray9752 2 года назад +1

    Very nice👍👍 good🇮🇳🇮🇳 Hindi Howarh WB

  • @khalilansari2265
    @khalilansari2265 3 года назад +7

    100%lepping

  • @iliaskhan3952
    @iliaskhan3952 3 года назад +1

    Lapping and welding do both this good for u

  • @aishyadavvideos
    @aishyadavvideos 3 года назад +7

    Always explain in a good manner .

  • @ak_homes_design
    @ak_homes_design 4 года назад +1

    Useful Video Sir .......

  • @rsd6317
    @rsd6317 4 года назад +8

    Coupling- Cost of making threads ? How far it is economical and practical?

  • @bikramjit15
    @bikramjit15 4 года назад +2

    Thank you very much Sir 👍👍👍👌👌👌😊😊😊

  • @RNGunding
    @RNGunding 4 года назад +3

    Very informative. Thanks.

  • @Life_is_Awesome_Civil
    @Life_is_Awesome_Civil 2 года назад +2

    Very nice

  • @prabujayk
    @prabujayk 4 года назад +4

    daily I am watching your videos. I learned lot of information in your chanel. In this video Can u please explain how we can threading for tmt steel ? Threaded steel Is readily available in market with coupling?

  • @commonmankolkata
    @commonmankolkata 4 года назад +1

    Jaab slab mein rod bandhna hai usme keya lapping karenge yaa to coupler denge?
    Main elect. Engineer hoon, yeh civil ka technical knowledge bohot kaam ate hai. Plz bataiye. Aur contact no. Share kare

  • @arunannamalai7035
    @arunannamalai7035 4 года назад +4

    Welding is not recommended for reinforcement lapping as it alters the material properties of the reinforcement due to heat produced during welding. Also there is reduction in the cross section of the reinforcement

  • @VinayKumar-kr8ne
    @VinayKumar-kr8ne 2 года назад +1

    Hello sir
    Agar hum slab ke sath hi lap dety hai column ke liye ?
    Please suggest wo shi hai ya nhi
    First floor ke baad humare column ka steel enough nhi tha isly slab ke sath hi column ready kar diye hai

  • @kanhaiyakumar-ur7rc
    @kanhaiyakumar-ur7rc 4 года назад +3

    Very very important video sir❤️

  • @prathameshbiradar1993
    @prathameshbiradar1993 2 года назад +1

    Lapping is the mostly better

  • @sampathr2
    @sampathr2 3 года назад +24

    Really wonderful explanation. For a layman like me, it is explained in simple and short. Tks for sharing.

  • @pawanvishwakarma5128
    @pawanvishwakarma5128 Год назад +1

    Sir, ham logon ke yahan coupler nahi mil pata, Kahan se purchase kare, address bataye pls.

  • @satyaallidona
    @satyaallidona 4 года назад +3

    LAPPING IS BEST

  • @wanphaimakdoh1027
    @wanphaimakdoh1027 Год назад +1

    Lapping is the best old design best

  • @karthikgowda3530
    @karthikgowda3530 4 года назад +6

    High pressure gas welding is the best and cost-efficient

  • @ajjuajjuajjuajju2070
    @ajjuajjuajjuajju2070 3 года назад +2

    Lapping bahut achcha rahega is my challenge hundred

  • @Tour_and_Knowledges
    @Tour_and_Knowledges 3 года назад +10

    For couple we need to get rod threaded that can also increase cost

  • @pike1577
    @pike1577 3 года назад +1

    सर ये कहा मिलेगा हमे हमारे यहां नही मिला है बिहार मोतिहारी मे

  • @SohanLal-ci3gx
    @SohanLal-ci3gx 3 года назад +3

    Only over lapping is effective.other aulternates like welding , coupling,the vertcal element(column) may shear up, horizontal element( beam) may effect tensile strength as well as compressive strength.

  • @civilengineeringpower
    @civilengineeringpower 4 года назад +1

    Nice brother

  • @ankurbhaker786
    @ankurbhaker786 3 года назад +36

    Precautions while using couplers:
    • The threads that are being developed on rebars by automatic threading machine must be observed that their length should be appropriate i.e. if the length of rebar coupler is 90 mm so the length of threads should be 45 mm in case of type-1 couplers. For inspection we must deploy an inspector at the steel yard whose duty should be just to inspect the length of the threads in lot of reinforcement before dispatching to the site for installation.
    • In case of type-1 threaded couplers, the inner threads must be made with a die instead of a lathe as the depth of the cut can be varied by later type of production.
    • The Contractor may try to hide the excessive threaded portion length on rebar by unacceptable means. Like in one instance, a contractor tried to use cutting disk to grind the excessive threaded portion and then after application of oil used sand to hide the shiny surface. So while inspecting the couplers the excessive length of couplers must be demotivated.
    • For the quality of reinforcement production at steel yard a full time QC practitioner should be deputed with sufficient experience in terms of reinforcement production for mechanical splices.
    • The Contractor must evaluate the quotations from different suppliers in terms of cost, quality and timely supply of the product. The approval is granted by the Engineer by thoroughly going through the technical performance certificates or test documentation commenting on the couplers.
    • The reinforcement bars must be cut by rotatory saw instead of cropping machine. The use of cropping machine results in an inclined end instead of being 90 degree cut therefore in order to engage fully the length of splice coupler the cut angle must be 90 degrees.
    • For lubrication in the automatic threading machine, only approved lube should be used and no cheap products or water should be used whatsoever. The quality of lubricant would have direct impact on the thread cut otherwise they would be damaged and would be irregular which not a good practice is.
    • The threads produced on the reinforcing bar must be checked in terms of pitch depth and accuracy. Pitch measuring tool or any other suitable tool might help in determination of suitability of the produced thread.

    • @Vamshi-k
      @Vamshi-k 3 года назад

      Io

    • @engr.asadallahrakha8738
      @engr.asadallahrakha8738 2 года назад +4

      Bro if we have to maintain so much things then lapping is best😂

    • @er.gurlabhsinghgill8254
      @er.gurlabhsinghgill8254 Год назад

      Best explained....please suggest some references to authentic literature/code for future implementations...thanks

    • @shreekanthraja1133
      @shreekanthraja1133 Год назад

      Thks a lot for sharing your experience and me too like you at work place very sincerely as the way you explain above

    • @rohandoon1235
      @rohandoon1235 Год назад

      Can we contact you

  • @noorainahmad5970
    @noorainahmad5970 3 года назад +1

    I think you are my classmate

  • @saileshsingh1
    @saileshsingh1 4 года назад +7

    You always bring practical and great topic! Thank you from Bottom of my heart..
    Can you plz bring something on topic FAR..
    Jaye Krishna Janma Asthami!
    Thank You.
    Shailesh Singh

  • @jagatjibansethy1544
    @jagatjibansethy1544 2 года назад +1

    Coupling ka cost kitna hai ?? Yeh toh batao nd costing ka comparison video kahan hai ??

  • @henrykharnaior5786
    @henrykharnaior5786 3 года назад +9

    Lapping is the best coZ we are in the quake zone 🙏🙏🙏🙏coupling is dangerous

  • @pike1577
    @pike1577 3 года назад +1

    Ha sir hame ghr banwana hai disamber mahina se kaise ham ban waye

  • @sonushahjahan5446
    @sonushahjahan5446 4 года назад +4

    Dear Sir 1 Question hai
    Sir Difference between Pile Foundation And Raft Foundation
    2. Question.
    Pile Foundation And Raft Foundation which Area me karte hai.
    Please sir Give me Ans.

    • @vikashkumargupta3955
      @vikashkumargupta3955 4 года назад

      Q1) pile fondation:- below the ground level and used in breeze but Raft or mat foundation both are same used in appartments.it is generally used in that area where soil strata has low bearing capacity.

  • @AvinashPahade
    @AvinashPahade 4 года назад +2

    coupler me thread to h..mgr rebar me thread nhi h ..to kya rebar me bhi theadd bnani pdegi ??? or uski costing firto badh ajegi

  • @manasmohanta7355
    @manasmohanta7355 4 года назад +5

    Drawback in coupling is to makeing thread on steel bar in leathe which is costly

  • @सुरेन्द्रजायसवाल-व3य

    श्री मान जी एक राय दीजिए आप हम दो लोग आपस में मिल कर एक नीव बनाई है हो कि ध्यान से उस वक़्त निकल गया बात ये है कि जो विच वालि नीव है वो 9 इंच की ही बनाई गलती से अब हम लोग चाहते हैं उसको कैसे अलग करे जो कि बाद में दिक्कत ना हो

  • @manits3547
    @manits3547 4 года назад +9

    Welding is acceptable with both sides welded in double layers duly chipped of. In this case the overlap will be normally 10 X Dia. of Bar or as per Designer's specification. The Weld is further subjected NDT / X-RAY confirmation for perfect welding. But Weldind is not unacceptable under any circumstances.

  • @nepalionlinetvshow1807
    @nepalionlinetvshow1807 4 года назад +1

    nice vodeo
    Copping best hai

  • @Kabir78677
    @Kabir78677 4 года назад +9

    कपलिंग नहीं करना चाहिए क्यों की अंदर थ्रेड होते है थ्रेड का मतलब सलिए पे कट होना और जहा कट लगा होगा वहा से टूट जाता है...

  • @abhishekabi9613
    @abhishekabi9613 2 года назад +1

    Coupling is better is used in 32mm bar & lapping used 10mm to 23 mm bar & finally 6mm bar should used in welding

  • @hoangkybactien7207
    @hoangkybactien7207 3 года назад +3

    I don't understand your language. But my feeling tell me that LAPPING is strongest, easiest and least expensive of the 3 methods. Right?

  • @SurajK-h9m
    @SurajK-h9m 3 месяца назад +1

    Coupling best hai sir

  • @mukuljha804
    @mukuljha804 4 года назад +3

    GREAT INFORMATION.THANK YOU SIR JI.

  • @mastiwithn.k.c4956
    @mastiwithn.k.c4956 3 года назад +1

    Lappingkarke welding

  • @londonoxfordstreet
    @londonoxfordstreet 3 года назад +8

    Boy, You are Excellent!

  • @mohdafrozali3396
    @mohdafrozali3396 3 года назад +1

    Lapping is better solution

  • @virandergoswami1811
    @virandergoswami1811 4 года назад +3

    What if dia of same vertical bar is to be reduced in case of columns for upper storeys....will coupling work?

  • @lifemotivationalquote9526
    @lifemotivationalquote9526 4 года назад +2

    Sir coupling method kya high construction sites par normally hoti kyo ki abhi normal building aur college meh aj bhi lapping method use hota hai

  • @biswapramanik221
    @biswapramanik221 3 года назад +4

    I love you sir ji ❤️ important education

  • @arjunarjunun7475
    @arjunarjunun7475 2 года назад +2

    Coupling me steel tensile honese structure failure hojahega..you focusing on easy way, lesser cost, etc,but it's highly risk right? for that kind of reason what is the preventing measure? I believe welding is worst in many cases bcs it loss the strength but lapping is better as compared to welding and coupling not for all factors but i said majorly...

  • @nehalkatre7691
    @nehalkatre7691 3 года назад +3

    Local thekedar :- Lohe ki tar se bandh lo baass khatammmm

  • @arunchandravanshi3800
    @arunchandravanshi3800 Год назад +1

    Bullet train project me coupling system se kaam ho raha hai..

  • @Boss-gk8kc
    @Boss-gk8kc 4 года назад +3

    Hi I really enjoy your videos. You explain things very well. I have a question; what if lapping method is used but the bar is not bent to make stagger ie it’s just joined straight , is that safe? Is it ok according to IS code ?

  • @cranecrazysystems5530
    @cranecrazysystems5530 Год назад +1

    Coupling is best