Jandy Pool Heater FAULT CHECK IGN STEPS Ignition Failure & How to Prevent Premature Retirement

Поделиться
HTML-код
  • Опубликовано: 24 янв 2025

Комментарии • 71

  • @joelthompson4801
    @joelthompson4801 Год назад +3

    Can we get the Amazon link for that sweet inspection camera?

  • @timothyharris3542
    @timothyharris3542 Год назад +1

    Could the heater exchanger be removed cleaned and pressure tested and the leak silver soldered or brazed

  • @DaneJoshuaTree
    @DaneJoshuaTree Год назад +1

    Awesome. Thanks

  • @robertjoseph1592
    @robertjoseph1592 Год назад +1

    Here in Arizona many people use a heat pump on their pool since it can be run in heating mode during cool months (November to May) and then in cooling mode during the really hot months (July to September). I don't have one so by midsummer my pool water is about 95 degrees Fahrenheit.

    • @robertjoseph1592
      @robertjoseph1592 Год назад +1

      @@PipeDoctor Yep, we actually root for hailstorms every August LOL!

  • @BeReady726
    @BeReady726 10 месяцев назад +2

    We have a pos like this, maybe the same model, and I just got this error. It’s only a few years old. Designed to break I’m sure, bc we never did anything bad to it, barely used it actually.

    • @PipeDoctor
      @PipeDoctor  10 месяцев назад +1

      Sorry for your loss

    • @ClarenceBonius
      @ClarenceBonius 10 месяцев назад

      Same here. Exact model
      With same error

    • @Shadypoolguy
      @Shadypoolguy 9 месяцев назад

      Most likely bad water chemistry, which is the cause of most heater failures. Most companies only test ph and cl levels and forget about the alkalinity levels which will eat the cooper in your pool heater.

    • @jimblack8677
      @jimblack8677 7 месяцев назад

      I take my water to Leslie at least every 2 weeks to be tested and ALWAYS FOLLOW THEIR ADVICE. The only reason these heaters fail is that they are garbage to begin with and NEVER SHOULD BE USED TO HEAT YOUR POOL WATER!!!!

    • @StopBullying2024
      @StopBullying2024 Месяц назад +1

      I have the same heater installed in 2020. I have had this error message almost since the beginning. They replaced the hot surface igniter a few times and of course now it’s not under warranty and will have to do it again or replace the whole unit. There should be a class action lawsuit against Jandy.

  • @eliasjiryis1
    @eliasjiryis1 4 месяца назад

    So what is the best heater when water hardness is high?

    • @Thomas52906
      @Thomas52906 3 месяца назад

      None you have to drain the water

    • @StopBullying2024
      @StopBullying2024 Месяц назад

      What does that mean

    • @Thomas52906
      @Thomas52906 28 дней назад

      @@StopBullying2024 it means there is nothing you can do about hardness in your pool besides draining the water

  • @FoxItAll
    @FoxItAll Год назад

    JXI is a 3 year heater here in Florida.

  • @j0nathan948
    @j0nathan948 Год назад

    Wait so why did it go bad? What caused it ??

  • @mattl643
    @mattl643 Год назад +2

    Make sure you add a corrosion resistant check valve before that chlorinator.

  • @MrBrettsb
    @MrBrettsb Год назад

    What’s the warranty on the heat exchanger?

    • @MrBrettsb
      @MrBrettsb Год назад +1

      @@PipeDoctor that will do it. I am anal about the chemistry of the pool and I keep the heater on bypass when not in use just to be safe

    • @grapplerguy2007
      @grapplerguy2007 Год назад

      ​@@PipeDoctoranyone can say water chemistry issues. But unfortunately for those type we have gps time stamped digital logs of all chemistry.

  • @hermankrissiaramirez4085
    @hermankrissiaramirez4085 Год назад

    I like how they Camouflage the equipment

    • @PipeDoctor
      @PipeDoctor  Год назад

      Let’s have the equipment get covered by weeds

  • @RandyBarnard-yf5bw
    @RandyBarnard-yf5bw Год назад +1

    The installer failed to install a anti-corrosive check valve between the heater in the chlorinator and that is why the heat exchanger failed

    • @JesusismySavior28
      @JesusismySavior28 Год назад

      Hi Randy with Fluidra. You are 100% correct. I’ve seen installers not adding one in most cases.

  • @Chris-ft2pq
    @Chris-ft2pq 8 месяцев назад

    Add a Vera flow valve to jxi the will prevent water from moving through when not in use. I would also have a check valve between heater and sanitizer.

  • @realestateservicessaleshea99
    @realestateservicessaleshea99 Год назад

    You have to be very meticulous about your pool water with a pool heater, unbalanced water can be corrosive !
    Thanks again for the videos.
    😐👍🏻🥃🥃🍺🍺🍺🇺🇲

    • @grapplerguy2007
      @grapplerguy2007 Год назад

      If ph drops below 7.2 yes otherwise you are high on scale. We practice lsi and csi on all pools and keep a log. Many times they try and blame pool guys. But these jandy heaters are failing sometimes well before 6 months mark. Couldn't ruin a heater from chemistry this soon even if ya tried. Jandy own manual says that allow for ph to be 6.8 and alk upwards 180ppm. It's not chemistry issue. Product issue and most likely it's electronics wiring with pressure switch or pressure switch itself. This is Also stated in the troubleshooting guide in jandy manual. Igniter has it own fault code same with flow error

  • @kellytaddeo3574
    @kellytaddeo3574 Год назад

    Why can't the hot surface ignitor just be replaced?? It's a replaceable part you can purchase.

    • @PipeDoctor
      @PipeDoctor  Год назад

      It can

    • @universaldonor3100
      @universaldonor3100 Год назад

      if the problem were a bad surface ignitor only, sure; but, the exchanger is bad and will only corrupt a new HSI....

  • @JoshuaPchelka
    @JoshuaPchelka 8 месяцев назад

    Calcium deposits such as that are due to poor water chemistry maintenance. Once the water can not hold calcium any longer it deposits in the warmest parts of the pool/ heater and it salt cell. PH and Alkalinity need to be checked every 4 to 7 days and calcium levels monthly.

  • @guillermocastillo6549
    @guillermocastillo6549 Год назад +1

    Low calcium hardness in the water could cause calcium build up too.

    • @donguadalucio1405
      @donguadalucio1405 7 месяцев назад

      The calcification was outside the copper coils not inside.

  • @ronaldbrosius7488
    @ronaldbrosius7488 Год назад

    The exhaust pipe! Bushes laying all over it 😂

  • @tylerwilliams3868
    @tylerwilliams3868 Год назад

    just wondering what the lifespan on a pool heater usually?

    • @donguadalucio1405
      @donguadalucio1405 7 месяцев назад

      5 to 10 years on residencial poosl and less than 5 year on commercial pools. JXI heaters are so bad that they last less than 4 years.

  • @ronlovell5374
    @ronlovell5374 Год назад +1

    I see this often, most times from poor installation and wrong orientation of pool equipment. (Heater not being installed after filtration and before the electronic or cemical clorinater) and if installed correctly, no check valves in place to prevent backflow contamination. Also, with salt water pools, the cartridge type filters are junk compared to sand media filters.

    • @grapplerguy2007
      @grapplerguy2007 Год назад

      Lmao cartridge filters better than sand. You also should use corrosion resistant check valves but even jandy stands by regular spa jandy style check valves between cell and heater Go figure.

    • @Koj2ez
      @Koj2ez Год назад +1

      D.E filters are probably the best filtration device for pools.

    • @grapplerguy2007
      @grapplerguy2007 Год назад

      @@Koj2ez duh

  • @brianjohnson8883
    @brianjohnson8883 Год назад +1

    It all has to do with water chemistry and if you only pay your pool guy $100/month don't count on it to be ideal.

  • @eltorpedo67
    @eltorpedo67 4 месяца назад

    Wow. I really wish I had seen this video before I bought my Jandy this year. Installed in May and already getting the IGN fault. I bought Jandy be cause the last one I had was also Jandy, but almost 20 years old and built like a tank. Looks like they're just another company building low quality junk now.

    • @PipeDoctor
      @PipeDoctor  4 месяца назад

      It’s a great heater

    • @StopBullying2024
      @StopBullying2024 Месяц назад

      I respectfully disagree. It’s only a great heater when it works. I have had a horrible experience and so have many others online. It’s a ridiculously bad heater

  • @eddiew.6485
    @eddiew.6485 Год назад +1

    Maybe after replacing the heater, recommend they fire their landscaper 😂

  • @damionfragoso2655
    @damionfragoso2655 Год назад +1

    It would kill the gardener to spray some weed killer around the pool equipment

    • @JesseDoesHVAC
      @JesseDoesHVAC Год назад

      Probably also kill the gardener from spraying all that poison on the earth

  • @lukepoolservice
    @lukepoolservice 10 месяцев назад +1

    Its a manufacturing defect. They should send the customer a new heater.

  • @kens.3729
    @kens.3729 Год назад +1

    Looks like the Homeowner allows a “Natural Prairie” around Pool Equipment. State DOT’s do that in Highway Right-of-Ways to Avoid Grass Cut Mtce. 🤪👎

  • @kens.3729
    @kens.3729 Год назад +1

    That Equipment doesn’t look Cheap so Why does it DIE in three (3) years ? Breach of Heat Exchanger ? Absolutely Unacceptable and Ridiculous. 🤪👎

  • @cravenmorpus
    @cravenmorpus Год назад

    The reason the heater is wired in with the pump is bc you want the heater to turn off with the pump, otherwise you could catch the heater on fire or burn the heater and other items up.
    Also, the calcium build up is bc it's a salt pool and they most likely don't pay attention to their pH and calcium levels like they should.

  • @Chris-ft2pq
    @Chris-ft2pq 8 месяцев назад +1

    5yr warranty on heat exchanger fyi

    • @PipeDoctor
      @PipeDoctor  8 месяцев назад

      Wrong

    • @kencastillo9177
      @kencastillo9177 3 месяца назад

      If it's got a Versaflo bypass on it the heat exchanger has 5 years warranty

  • @STXVIEC
    @STXVIEC Год назад

    classic jandy fail. Happened to me 2 times. Never again lol

    • @STXVIEC
      @STXVIEC Год назад

      @@PipeDoctor First unit (JXI-400) was installed March 2020 with pool instillation & Failed September 2020. Then replaced through warranty. Second one was from September 2020- June 2022. 2 years old & no longer under warranty. Both times were faulty heat exchangers. Water chemistry was always on point!

  • @shawnkauffman5537
    @shawnkauffman5537 Год назад

    "It's on the Fritz" lol

  • @scottmaz4063
    @scottmaz4063 Год назад +3

    Looks like rock salt

  • @scottmaz4063
    @scottmaz4063 Год назад

    #1

  • @Mike-rm7vf
    @Mike-rm7vf Год назад

    That’s gotta be made by Raypak. Pure junk.

  • @Egittv
    @Egittv 8 месяцев назад

    You talk too much but you didn’t show what is the solution 🤦🏻‍♀️🤦🏻‍♀️🤦🏻‍♀️ if do we need to replace that ignition or we need to clean that inside the heater???!🙄🙄🙄

  • @Splattertube
    @Splattertube 10 месяцев назад

    A plumber who thinks he knows pool equipment.

    • @PipeDoctor
      @PipeDoctor  9 месяцев назад +2

      Yes, factory trained b!tch