    @RonaldoSilva-tn8in 3 месяца назад +2

    Lâmpada 150 Watts completamente preta ? 💡😕

  • @solomonwolf9388
    @solomonwolf9388 Год назад +1

    Could you try running that bulb on a 150w metal halide ballast? it will not cycle on 150w mh gear because the available voltage of hps ballasts is too low which is why it cycles on a hps ballast. It will work without cycling on a 150w mh ballast because 70w S62 hps current is 1.37A and 150w mh current is 1.44A. please trust me on this.

  • @sethbower11
    @sethbower11 Год назад

    “BuT i DoN’t CoLlEcT hId!” 🤪

  • @jsaudio7428
    @jsaudio7428 Год назад +1

    nice

  • @johnhipp604
    @johnhipp604 Год назад +1

    Have a question about the bulb

    • @BROKEN.WRENCH.GARAGE
      @BROKEN.WRENCH.GARAGE  Год назад

      Yes?

    • @johnhipp604
      @johnhipp604 Год назад

      @@BROKEN.WRENCH.GARAGE why is it green

    • @BROKEN.WRENCH.GARAGE
      @BROKEN.WRENCH.GARAGE  Год назад

      Because the sodium has leaked out of the arctube into the outer jacket of the bulb, aka the blackening.. leaving only mercury in the arc tube

    • @johnhipp604
      @johnhipp604 Год назад

      @@BROKEN.WRENCH.GARAGE its a good 💡

  • @HIDLad001
    @HIDLad001 Год назад +2

    Pulse start mercury vapor!

  • @adamfaruga899
    @adamfaruga899 Год назад +1

    is it a dying SON bulb?

  • @bfdi267nkdog2
    @bfdi267nkdog2 Год назад +1

    I bought the high-pressure sodium lamp