35 to 45 suction pressure 130 to 160 discharge pressure All ready kaise koi bhi refrigerant ka suction discharge find out karte h upload Kiya hua h vedio refrigerant se related 2 vedio h
Vaiya 134a gas ke bareme bar me bataiye suction discharge standing pressure Kitna hota or ak system me 15 ho ka 6 compressor ha to kayse Kam korta plz bataiye
Is par full ek vedio h kisi bhi refrigerant ka Suction and discharge paressure kitna hona chahiye..aap dekhe Aise jab aap puche h to 134a ka SP 30se 45 aur DP 100 se 145 psi ye Water Cooled Chiller ka reading rahega Air Cooled Chiller me 134a ka sirf discharge thoda jaydh jayega..jaise 120 se 160 psi Tak ruclips.net/video/34BMgpTSwCo/видео.html
Nahi .... discharge paressure jaydh hone par hp se trip karta h ...hp kharab h ya bypass Kar diye h aap to.... condenser ka design pressure aane par relief valve open ho jayega ....... disign pressure cat log par likha rahega aise lagbhag 450 psi Tak unlog chek karta h ....I am not sure condenser par design pressure company Wala mention Kiya rahta h.....
Liquid refrigerant mix with oil in evaporator what's effects on discharge superheat, suction superheat and subcooling per sir make a video 📹 your lectures more helpful thanks
Bhai mere 2 questions hai.plz is Ko clear kijiye quickly.. 1: what is a set point temperature? How to calculate spt? 2:what is the spt value in evaporator and condenser? 3:what is ∆T? What is the value of∆T ?and how to calculate?
Aapki question ko ham ache se samjh nahi paye.....but mere hisab se Jo aap ne pucha h wo wo Chiller ka set point hai ...Because this work is also done in Ahu delta T and delta P aise hamlog chiller me 7 'c par stp rakhte h ye standard h Kam bhi rakh sakte h as per requirement.....anti fridge Jo Sefty device h use 5 par rakhte h.....delta T 5 to 7 ke bich standard h...
Kaha bataye time agar h 2 sal ya 3 sal to short term course Karne se acha h aap iti ya diploma Kar lo....iti to RAC se hota h ...aur dimploma machenical se Kar sakte h
आपलोग कन्फ्यूज़ होकर विडियो क्यों बनाते हैं ? अगर आप HVAC के बारे में बताते हैं तो R134a के बारे में पुरा जानकारी क्यों नहीं बताते की इसका HP या LP इतना होता है। Oil इतना होता है फ्रीजिंग इतना पर होता है । केवल बात को घुमाते हैं जैसे हमलोग बहुत बड़े ज्ञानी है अगर ज्ञानी होते तो आपका विडियो क्यों देखते। मैंने कुछ गलती बोला तो छमा चाहता हूं।🙏🏼
नहीं सर आपका बात बिल्कुल सही h लेकिन एक ही vedio मे सब बताना पॉसिबल नहीं है वीडियों बहुत लंबा हो जाता है और लोग नहीं देखते हैं और हमे सब के हिसाब से चलना है औऱ दूसरी बात आप मेरा बाकी वीडियों देखिए refrigerant का उसमें हम बताये हैं और मे एक लिंक दूँगा आपको नीचे मे जिससे आप कोई भी Gas का प्रेशर खुद से निकाल सकते है... आप पहले पूरा वीडियों तो देखिये.. आप भी तो 5 से 10 मिनट मे सोचते हैं चिल्लर Technician बनजाए 1 साल 2 साल 3 साल 4 साल का सब पढ़ाई करते हैं तब जा कर कुछ सीख पाते हैं उसके बाद प्रैक्टिकल करते हैं.... आप को किसी भी तरह का जानकारी चाहिए सर्च करे चैनल मे नही मिलता h वीडियों बोले बना देंगे अलग से 15 से 20 gas use होते है एसी लाइन मे एक ही vedio Me सब कैसे Bataya जा सकता.... Ye वीडियों मे सेफ्टी के बारे मे Bataya गया है
और सेटिंग करने के लिए प्रेशर लोग मिलता h कितना पर cut off ponit रखना है..... आपको प्रेशर मालूम है तो उससे 20 psi बढ़ा कर सेट कीजिए किया होता है हमलोग स्टैंडर्ड ले कर चलते हैं.... अब कहीं कहीं क्लाइंट बोलता है हमको 18 'c temp चाहिए आपको देना होगा उसको ये नहीं बोलेंगे ac मे admi को itna temp नहीं देते हैं.... इसी तरह से चिल्लर का लोग सीट मे सब Bataya जाता है कितना रखना h मे Functions Bataya hu
Assalamualaikum..
Mashallah very knowledgeable topic what you have discussed here.and mostly asked question in interviews..
Walekum asslam warahmatullahi barkatuho
bahut badhia
Good job👍
Sir i get to learn a lot by watching your videos i wish you were my teacher i would have learned a lot
Thanks for your compliment 😊
Tanks Mr.afzal
Gud explanation
Masha Allah 💞
Nice sir
Nice sir,take care
Good
Thanks very good explanation, please say about CHILLER CONTROLLING DEVICE...CLIENT ASKED ME IN INTERVIEW
Just one thing to tell him to maintain the temperature
Insaallah 2 din ke andar ham upload karenege AHU fcu controling device Ka ....same function chiller me hota h
Excellent
Sir please tell me about 134a suction and discharge preasure in aircolled chiller
35 to 45 suction pressure
130 to 160 discharge pressure
All ready kaise koi bhi refrigerant ka suction discharge find out karte h upload Kiya hua h vedio refrigerant se related 2 vedio h
150 se 160
Vaiya 134a gas ke bareme bar me bataiye suction discharge standing pressure Kitna hota or ak system me 15 ho ka 6 compressor ha to kayse Kam korta plz bataiye
Thik h 134 a par chiller and split and fridge me kitna pressure kaise rahega ek vedio banate h
Sir chiller me R134a h to Suction or Discharge presser kitna hoga please
Is par full ek vedio h kisi bhi refrigerant ka Suction and discharge paressure kitna hona chahiye..aap dekhe
Aise jab aap puche h to 134a ka SP 30se 45 aur DP 100 se 145 psi ye Water Cooled Chiller ka reading rahega
Air Cooled Chiller me 134a ka sirf discharge thoda jaydh jayega..jaise 120 se 160 psi Tak
ruclips.net/video/34BMgpTSwCo/видео.html
Pls sabki limit bhi btaye kitni hoti hai kitne oe Hp lp hota hai oil pressure kitna hina chiye etc
Ok
Sir Ap Resume me ek video banaye ki resume me kya kya work likha rahta hai
Resume ka upload h video
Wow
Hp switch ka temperature kitna hota h.plz aap bataiye
Hp pressure pe set Kiya hua rahta h .... discharge high hone par system ko trip Kara deta h
@@Afzalalamhvac sir gg kitna pr set hota h.aprox value.
300psi par
Sir hp or lp switch mein neutral conditions kaise hoga
Neutral ki jarurt nahi h lp hp ko series me lagaya Jata hai
Dear sir agr Mai apne room ka pora vav closed kar dun to Ahu pe kya effect padega Plzz tell me
No effect.....ahu ka motor Jo hota h vfd se connect rahta h agar required Kam rahega air flow ka to motor slow speed hoga
Sir oil pressure issue base kee isaba video sir
Samjhe Nahi
Sir,Control wiring and power wiring pe detail me video banayen,for interview purpose se,
Power wiring ka vedio upload
Star delta main ka
ruclips.net/video/GiHjf8xoF4s/видео.html
Ye hai main delta and star ka
Relief valve discharge pressure ziyada hone par open aur closed hota hi
Nahi .... discharge paressure jaydh hone par hp se trip karta h ...hp kharab h ya bypass Kar diye h aap to.... condenser ka design pressure aane par relief valve open ho jayega ....... disign pressure cat log par likha rahega aise lagbhag 450 psi Tak unlog chek karta h ....I am not sure condenser par design pressure company Wala mention Kiya rahta h.....
Sir app bahut accha explain kar rahe hai par voice quality thik nahi hai.
Thik ye starting ka vedio hai abhi ka vedio me voice ka problem solve hai
Liquid refrigerant mix with oil in evaporator what's effects on discharge superheat, suction superheat and subcooling per sir make a video 📹 your lectures more helpful thanks
Ok wait kijiye is par bhi upload karnege abhi ham busy h is liye. Thoda samay ke bad continue rahega
Bhai mere 2 questions hai.plz is Ko clear kijiye quickly..
1: what is a set point temperature?
How to calculate spt?
2:what is the spt value in evaporator and condenser?
3:what is ∆T? What is the value of∆T ?and how to calculate?
Aapki question ko ham ache se samjh nahi paye.....but mere hisab se Jo aap ne pucha h wo wo Chiller ka set point hai ...Because this work is also done in Ahu delta T and delta P aise hamlog chiller me 7 'c par stp rakhte h ye standard h Kam bhi rakh sakte h as per requirement.....anti fridge Jo Sefty device h use 5 par rakhte h.....delta T 5 to 7 ke bich standard h...
Delta T difference between Chiller inlet temp and outlet tempreture it is called delta T
Bms Operator interview questions kiya pocha jata hai?
Bms me vfd vav aur dps aur bhi bhut sare part hote hai uska puchs Jata h us par alga se vedio upload karnege
Thinks sir
Welcome
Gas top up pe bnaiye
Ok
Sir koi acha institute bataiye jaha HVAC course kraya jata ho?
Kaha bataye time agar h 2 sal ya 3 sal to short term course Karne se acha h aap iti ya diploma Kar lo....iti to RAC se hota h ...aur dimploma machenical se Kar sakte h
Cwfs fault kyo aata hai
👏👏
Sensor wire never directly connect with power line
It's connect in magnetic contractor.
Yes I know
Sir aap apne sare videos q delete kiye...
Please explain complete procedure step by step how refrigerant is charged in chiller. Please explain sir. Humble request.
OK insallah very soon upload vedio
@@Afzalalamhvac thank you🙏 sir
@@Afzalalamhvac bhulna mat sir
Sar rela contaktur kya hota hai
Relay hota h aur contactor ye bi bhut important device h .....all ready contactor ka vedio upload hai
Arre bhaiya ek mice kharid lijiye achha voice rahega to aur video viral hoga
Thik h
I am also waching this time
Brother nice but pls post the real picture where it is located along with video
Ok I will try
Do for air cooled chiller safety devices along with vedios and picture if u can explain it well please. Even it take time no problems.
Also please do vedios for air cooled and their safety devices where is it located
Hai chiller ka videos karo sir
Ok
AHU or FCU kha answers Batteau
Vedio ka discription me link dala hua h ahu ka live vedio 8 mint ka aap dekh le aapko sab samjh me aa jayega
In Which country are you bro?
Oman
Abi mai video dekha rha hun...
Sir explain with photos
Ok
How to select best 200 TR air cooled chiller of different vendors
Thankyou sir ji..
Welcome
Bhai app kaha job karte ho?
Oman me
QQ sare videos delete kiye.. 😫😫😭😭😭
Kuch technical problem ho gyi thi dhire dhire solve ho jayega
आपलोग कन्फ्यूज़ होकर विडियो क्यों बनाते हैं ? अगर आप HVAC के बारे में बताते हैं तो R134a के बारे में पुरा जानकारी क्यों नहीं बताते की इसका HP या LP इतना होता है। Oil इतना होता है फ्रीजिंग इतना पर होता है । केवल बात को घुमाते हैं जैसे हमलोग बहुत बड़े ज्ञानी है अगर ज्ञानी होते तो आपका विडियो क्यों देखते। मैंने कुछ गलती बोला तो छमा चाहता हूं।🙏🏼
नहीं सर आपका बात बिल्कुल सही h लेकिन एक ही vedio मे सब बताना पॉसिबल नहीं है वीडियों बहुत लंबा हो जाता है और लोग नहीं देखते हैं और हमे सब के हिसाब से चलना है
औऱ दूसरी बात आप मेरा बाकी वीडियों देखिए refrigerant का उसमें हम बताये हैं और मे एक लिंक दूँगा आपको नीचे मे जिससे आप कोई भी Gas का प्रेशर खुद से निकाल सकते है... आप पहले पूरा वीडियों तो देखिये..
आप भी तो 5 से 10 मिनट मे सोचते हैं चिल्लर Technician बनजाए 1 साल 2 साल 3 साल 4 साल का सब पढ़ाई करते हैं तब जा कर कुछ सीख पाते हैं उसके बाद प्रैक्टिकल करते हैं.... आप को किसी भी तरह का जानकारी चाहिए सर्च करे चैनल मे नही मिलता h वीडियों बोले बना देंगे अलग से
15 से 20 gas use होते है एसी लाइन मे एक ही vedio Me सब कैसे Bataya जा सकता.... Ye वीडियों मे सेफ्टी के बारे मे Bataya गया है
ruclips.net/video/34BMgpTSwCo/видео.html
Ye देखिए और भी हम बताये हैं
3 वीडियों जिससे आप देख सकते h Gas का प्रेशर कितना होगा.... देख कर बताइए कैसा लगा
और सेटिंग करने के लिए प्रेशर लोग मिलता h कितना पर cut off ponit रखना है..... आपको प्रेशर मालूम है तो उससे 20 psi बढ़ा कर सेट कीजिए किया होता है हमलोग स्टैंडर्ड ले कर चलते हैं.... अब कहीं कहीं क्लाइंट बोलता है हमको 18 'c temp चाहिए आपको देना होगा उसको ये नहीं बोलेंगे ac मे admi को itna temp नहीं देते हैं.... इसी तरह से चिल्लर का लोग सीट मे सब Bataya जाता है कितना रखना h मे Functions Bataya hu
@@Afzalalamhvac great reply 👍
It's not possible in 1 one video to clarify all the things..😊