FA-3 Frequency Counter by BG7TBL

Поделиться
HTML-код
  • Опубликовано: 11 сен 2024
  • I know I said I wasn’t going to do a review of this, but thought some of you would like to see the Start-Up of this unit.
    Links to some info;
    Index of /BG7TBL (gswagner.com)
    Or
    gswagner.com/B...

Комментарии • 8

  • @Electrotech1980
    @Electrotech1980 7 месяцев назад +1

    Thanks for the effort. I just wonder why you used 0.1S gate time rather than 1S or even 10S to compare results? I've been comparing mine to a GPS reference and I'm quite impressed.
    I found these specifications on an Ali Express ad.
    FA-3 Frequency Counter Frequency Meter 1Hz-6G 11Bit/Sec High-Precision FA-3 FREQ COUNTER
    Specifications:
    - Type:FA-3-6G/FA-3-12.4G/FA-3-26.5G/FA-3-6GP
    - CH1 frequency range: 1Hz-300MHz
    - CH1 input impedance: 50Ω/1MΩ
    - CH1 input reference sensitivity: 50Ω: 25mVrms-2Vrms; 1MΩ: 25mVrms-2Vrms
    - CH1 frequency accuracy: 0.1-second gate: 0.001Hz at 10M; 1-second gate: 0.0001Hz at 10M; 10-second gate: 0.00001Hz at 10M
    - CH1 measurement speed: 11 bits/sec at 10M
    - CH1 power test range: -50DBM to +20DBM, 1M-550M at 50 OHM
    - CH1 power measurement accuracy: 0.5DB at 10MHz
    - CH1 interface type: BNC
    - CH2 frequency range:6G:30MHz-6GHz /12.4G:200M-12.4G/26.5G:200M-26.5G/6GP:30MHz-6GHz(with power meter)
    - CH2 input impedance: 50 OHM
    - CH2 frequency accuracy: 0.1-second gate: 1Hz at 1GHz; 1-second gate: 0.01Hz at 1GHz; 10-second gate: 0.001Hz at 1GHz
    - CH2 input power: 6G: -20dBM to +13dBm at 0.5-5G
    - CH2 interface type: SMA
    - Gate time: 0.1 second/1 second/10 second
    - Internal reference frequency: 10MHz
    - Internal reference type: OCXO
    - Internal base year aging: 0.5Hz
    - Internal reference output port power: 4dBm
    - External reference input power range: 6G:-20dBM- +13dBm@0.5-5G、 12.4G:-20DBM-+13DBM@0.2-10G、26.5G:-15-+5DBM@1G-26.5G /6GP:-20-+13DBM@0.5-5G
    - Panel screen: 3.2 inches, 128*64pixel
    - Operation modes: CH1 frequency measurement mode, CH1 statistical mode, CH2 frequency measurement mode, CH2 statistical mode
    - Statistics mode data types: average, maximum, minimum, peak-to-peak value
    - Power supply: 11.7-12.5V, Start:

  • @germanjohn5626
    @germanjohn5626 6 месяцев назад

    had you printed on both sides of the paper you culd have condensed it even more lol

  • @raymiller5738
    @raymiller5738 7 месяцев назад

    Thanks for the video always helpful to have another view of the instrument, seems to be well constructed and as you say would be good to have a manual with codes etc. Is there any way to battery power as an option I wonder? One of the web pages gives this as an option. The low frequency cut-off is probably due to the input coupling capacitor, so adding a parallel one on CH2 would lower it to be more in specification?

  • @marcinmakan9710
    @marcinmakan9710 8 месяцев назад

    Hello, what is the maximum voltage (or amplitude) of a signal that the BGT7TBL FA-3 (or FA-2) frequency counter can handle? I would appreciate your support a lot!

  • @pedromoreno4430
    @pedromoreno4430 6 месяцев назад

    Hi there, Can I use any of these frequency meters to measure EMF (up to 30Ghz) connected directly to a passive microwave antenna? I´m interested in measuring the millimetric 5G radiation received in my home and I don´t want to spend thousand of euros in a professional EMF device.

  • @richardmiranda5357
    @richardmiranda5357 11 месяцев назад

    I just checked on eBay and there is a bunch o FA-3 for a decent price. All from China.

  • @t1d100
    @t1d100 11 месяцев назад

    👍