    @SovereignTroll 3 года назад +1

    For ONE THIN DIME, one-tenth of a dollar - your can see wild and unusual refrigeration hack acts before your very eyes... STEP right up and SEE Sideshow Bob, the Master of Disaster! Love the Sideshow reference!

  • @shine-cg9uf
    @shine-cg9uf 4 года назад

    Was on a call this morning. Leak at the txv flare nut. D-tech select picked it up. Tighten flare nut n didn't c bubbles or snip any leaks. But I'm gonna go back for a follow up. Thanks Dave.

  • @jimmyp5487
    @jimmyp5487 4 года назад +5

    I usually turn the Evap fans off when sniffing around inside Evaps... good repair brotha 🤘🤘🇺🇸🇺🇸

    • @indoorcomfort6021
      @indoorcomfort6021 3 года назад

      He didn't even like or heart your comment, I bet I know why!

    • @NorCal-refrigeration
      @NorCal-refrigeration  3 года назад

      Shiz I’m working 2 jobs give me a minute. Now go watch the follow up video. INFICON said I got a dud and I did new one works

  • @tyhuffman5447
    @tyhuffman5447 4 года назад

    RUclips police. Breaker 19. Major infraction - driving without seatbelt. Minor observation - the liquid line next to the distributer you fixed has no grommet and looks to be rubbing on the frame of the evaporator. Thanks for the video, and good job.

  • @analogmoz
    @analogmoz 4 года назад +2

    You are making me very glad I bought the H-10 Pro and not the D-Tek.

  • @kingofthecrease30
    @kingofthecrease30 4 года назад +1

    i bought the H10 pro leak detector earlier this year and so far its the best i ever had...last week i ordered the Testo 316-4 leak detector...its coming in on tuesday...cant wait to try it out...saw good reviews on it ...i needed a hand held one for supermarket work...its alot easier to carry around than the H10 is. Also i got it for $100 less than what tru tech tools was selling it for.

    • @NorCal-refrigeration
      @NorCal-refrigeration  4 года назад +1

      H-10 industries standard let me know how the 316-4 dose. The D3 is slow reaction time. And on off button is a crap shoot.

  • @HardKnocks101
    @HardKnocks101 4 года назад +1

    I call that previous tech Freezer Freddy...he has an old beat up van, no name on it, analog gauges, 2 screw drivers and a bag of wrenches, lots of duct tape and liquid nail - he also does plumbing and electrical and knows just enough to be scary. C store owners like him because his mode of payment is a couple of cases of clydesdale piss and a pint of schnapps!

  • @scottk0623
    @scottk0623 4 года назад +1

    Nice job Dave, still can’t beat the H10. You turned me on to that Streamlight headlamp. I bought 2 of them about 6 months ago, BEST headlamp I’ve ever owned. Simple on off no multi mode bullshit.

    • @NorCal-refrigeration
      @NorCal-refrigeration  4 года назад +1

      I honestly can’t work with out it. Have 2 at the day job also

    • @warrensharp935
      @warrensharp935 4 года назад

      What is make and model number of one's you use? Thanks

    • @scottk0623
      @scottk0623 4 года назад

      Warren Sharp the “Double Clutch” comes either reachable or AAA.

  • @ronkurey8840
    @ronkurey8840 4 года назад +4

    Any braze joint that does not leak...is a good joint...no matter what it looks like!

  • @TheOneshot78
    @TheOneshot78 4 года назад +3

    H10 all the way. H10 was my first and last leak detector

    • @NorCal-refrigeration
      @NorCal-refrigeration  4 года назад +1

      Me too. Nothing gets close. I got this for test out

    • @christiansommer914
      @christiansommer914 4 года назад +1

      @@NorCal-refrigeration
      If you a sticking with the H10 after testing, then I could test it on the other side of the pond😉
      Just to make sure the its the same result on other continents

    • @OcRefrig
      @OcRefrig 4 года назад

      Yep , nothing comes close ! I’ve been using h10’s since the mid 80’s. Nothing better !

    • @NorCal-refrigeration
      @NorCal-refrigeration  4 года назад +1

      @@christiansommer914 😂🤣😂🤣

  • @hvactrevv23
    @hvactrevv23 4 года назад

    Them caked Evap coils should of been the dead giveaway to back away 😂😂😂. Yikes but with Dave on the scene you’ll tell em what to do to get it right. Thanks for the video

  • @OcRefrig
    @OcRefrig 4 года назад +17

    Good video. It’s very difficult to find leaks with 12 fans blowing in the room constantly pulling fresh air across the tiny leak area. Make life slot easier for yourself , turn off condenser , let suction rise abiT, turn off evap fans , then go leak hunting. It makes it a lot easier to find a leak fast & accurately. Guaranteed u find most leaks accurately in a few minutes using this method. Good video ! Those evaps are time to go !

    • @primetime758
      @primetime758 3 года назад +1

      lookie here the self proclaimed GOAT of refrigeration

  • @Leadmining44
    @Leadmining44 4 года назад

    Nor Cal Nothing beats the H-10. For grab and go I hated the Inficon D-Tec I’m trying the Testo 316-3 now seems good. Bubbles work every time😂

    • @analogmoz
      @analogmoz 4 года назад +1

      I purchased a Testo 316-3 and I never seemed to have any luck with it. The silly thing would freak out every time it was bumped, moved, etc. I sent it back to Testo for calibration. Came back kinda the same. Lemme know if you want to buy my one as a backup for super cheap!

    • @antoniecsirefrigerationcc6965
      @antoniecsirefrigerationcc6965 4 года назад +1

      The testo works ok for me. If the battery is low you find a leaks all over. Replace with new battery and then u see. Good luck.

    • @Leadmining44
      @Leadmining44 4 года назад

      Company buys all tools👍

    • @NorCal-refrigeration
      @NorCal-refrigeration  4 года назад +1

      I’m an H-10 die hard. Made a song about it. It’s in my playlist. I got this to make videos the SRL8 is better than the dtek3

  • @sknight0391
    @sknight0391 4 года назад

    As long as Mr Hankey ain't bubbling that's all that matters 👍
    Who cares what he looks like.

  • @musamanneh6014
    @musamanneh6014 3 года назад

    thanks again good job

  • @harrydickson4575
    @harrydickson4575 4 года назад

    Great job Dave 👍👍👍

  • @RichGT350r
    @RichGT350r 4 года назад

    Thanks Dave! Look into a Captain Hook Torch Tip. It wraps the flame around the joint!

  • @amadeusrocks4967
    @amadeusrocks4967 4 года назад

    the D-tek 3 is so slow to detect leaks but it works good

  • @flhvacrfossil2124
    @flhvacrfossil2124 4 года назад +1

    Go to autozone or advanced , ask for a electronic flasher for turn signals, done. No need for resisters.👍

  • @whitesheatingairappliancer7101
    @whitesheatingairappliancer7101 4 года назад

    Nice video

  • @daveg8918
    @daveg8918 4 года назад

    Those are the worst solder joints to have to do!!! One someone probably soft soldered it originally then someone did silfos15 over it and then trying to get it to flow upwards is always a pain!!! But great work brother.

  • @gtmrefrigerationac
    @gtmrefrigerationac 4 года назад

    hey dave, your left indicator need to be checked out.

  • @frankjackson1918
    @frankjackson1918 4 года назад +1

    Good job super Dave. It ain't pretty but as long as it does not leak it's a win! If you keep doing torch work without safety glasses you are going to have a hard time finding leaks with just one eye.

  • @FlyEaglesFly19111
    @FlyEaglesFly19111 4 года назад

    Thats a beat up turd. I dont think a spit and shine is gonna make a difference for long on that one. Stay safe brother Dave

  • @samuelaranda4597
    @samuelaranda4597 4 года назад +1

    Good job Dave.
    I have that same detector. I spoke to the rep. It is slow. They also said is to keep it steady when locating a leak. What can you do about a turd from someone else. It worked! Sometimes the ugly chicks dances better at the High School dance

  • @joecorbin5158
    @joecorbin5158 4 года назад

    The distributor is brass...
    you will have to use 45%...
    Dissimilar joints require it for any longevity

  • @whitesheatingairappliancer7101
    @whitesheatingairappliancer7101 4 года назад

    That's a s**t show. It's crazy how they ran the liquid line? Will there be any buildup from brazing?

  • @timr4362
    @timr4362 4 года назад

    I can weld by brail no issues looks good too but distribution tubes your welds look like mine but no leaders is what matters good job Dave

  • @Eddy63
    @Eddy63 4 года назад

    I don't know if Vodka makes your vids better , but it sure makes me better ... Lol ...Good vid Super Dave ...

  • @RayRay-nb7tn
    @RayRay-nb7tn 4 года назад +1

    So overall what detector you like the best and why? Seems i like the bubbles detector best overall. That entire store needs revamping start to finish. But they got a good tech working to keep them trucking til they need to replace it. Thanks for sharing bud.

  • @veil67
    @veil67 4 года назад

    signal light is burned on the left side , in the front or the rear of your van that’s
    why it blinks that fast

    • @NorCal-refrigeration
      @NorCal-refrigeration  4 года назад

      I installed l e d s and no resistor

    • @flhvacrfossil2124
      @flhvacrfossil2124 4 года назад

      Needs electronic flasher, LED's will hyperflash with OEM flasher. Installing resistors is PITA.

  • @TheRotax100uk
    @TheRotax100uk 4 года назад +1

    Where the liquid line comes into the Evaporator through the case must be rubbing out too.

  • @binhashimhvacrservices284
    @binhashimhvacrservices284 4 года назад +1

    Dave change your broken indicator light please

    • @NorCal-refrigeration
      @NorCal-refrigeration  4 года назад +2

      It needs a resistor I installed l e d year ago.

    • @qeesher
      @qeesher 4 года назад

      @@NorCal-refrigeration previous owner of my truck just put a black electric tape on the glass over indicator. No need for a resistor :)

  • @throttlebottle5906
    @throttlebottle5906 4 года назад

    who pooped on the tubing and fittings LOL

  • @throttlebottle5906
    @throttlebottle5906 4 года назад

    just another walk in warmer =p

  • @scubasteveTN
    @scubasteveTN 4 года назад

    Tell me about what you lit your torch with?

    • @NorCal-refrigeration
      @NorCal-refrigeration  4 года назад +1

      Ahhh I’ve had that striker since 2003. Push button spark ⚡️

    • @throttlebottle5906
      @throttlebottle5906 4 года назад

      you can try an out of fuel "long lighter" as a striker, but the spark may not be strong enough

  • @repetemyname842
    @repetemyname842 4 года назад

    Nice save, Dave

  • @life_behind_bars
    @life_behind_bars 4 года назад +1

    Yeah that leak detector would have to go. By the time that thing reacts to the leak I would already be at the condensing unit leak checking.

  • @gregbowman3598
    @gregbowman3598 4 года назад

    Nice Dave 👍

  • @HermesVintage
    @HermesVintage 4 года назад

    I thought you had to use a different kind of solder when you have to braze two different metals together

    • @NorCal-refrigeration
      @NorCal-refrigeration  4 года назад +1

      I use 56%.

    • @qeesher
      @qeesher 4 года назад

      @@NorCal-refrigeration thanks for the video. Was it because of different metals you used 56% alloy? which one do you use regularly? thanks

  • @sterlingarcher46
    @sterlingarcher46 4 года назад

    Hey so since it's 407c , I can't stand 407c , did you have to pull the remaining refrigerant and charge with brand new then ?

    • @christiansommer914
      @christiansommer914 4 года назад

      Hate its 2..only seen it used on chillers and mini splits here in DK.. Yes you have 2 give it a complete new charge.. But if I'm honest i don't always do it.. If you do Then you might as well convert it

    • @NorCal-refrigeration
      @NorCal-refrigeration  4 года назад +1

      Correct it will fractionate

  • @mikepict9011
    @mikepict9011 3 года назад

    Weak ass pump motor. Thats 99% of it . The new one with the led screen my coworker got . Thing sounds like a vacuum cleaner. Probably the same sensor. Inficon service sucks for parts , just terrible. But they work

    • @NorCal-refrigeration
      @NorCal-refrigeration  3 года назад

      Check out my follow up video. They sent me a warranty one and said I got a dud. The new one works 🤘🤘

  • @jerzyaheardz6939
    @jerzyaheardz6939 4 года назад +1

    How you liking that new DTek Dave?

    • @NorCal-refrigeration
      @NorCal-refrigeration  4 года назад +1

      Not sure yet. I’m still understanding how it works, it seems slow response but I might just need to get used to it. I’ll have a video after more testing

  • @WswRefrigeration
    @WswRefrigeration 4 года назад +1

    I was going to ask you how you like the new Detek? I have the srl8, at first I was iffy about it but now I think it’s a pretty damn good detector. That new detek seems ehhh

    • @NorCal-refrigeration
      @NorCal-refrigeration  4 года назад

      SLR8 is my back up to the H-10 it dose a good job. I need to get used to the d-tek3 before I make a video on it.

  • @reyrodriguez1005
    @reyrodriguez1005 4 года назад

    Did you clean those coils??

  • @hvactechpr7872
    @hvactechpr7872 4 года назад

    My old saying can look ugly but not a leaker!!!

  • @joshuabest100
    @joshuabest100 4 года назад

    Seems like mixed readings with them leak detectors

  • @bruceshepherd6217
    @bruceshepherd6217 3 года назад

    TO MUCH PLAYIG ON CUSTOMER TIME

    • @NorCal-refrigeration
      @NorCal-refrigeration  3 года назад

      Ya like guys before me that gas and goes. 😂😂😂😂I’m so fast I do 2 guys worth in 8 hrs. 🤘⚡️🤘✨

  • @steveblake8766
    @steveblake8766 4 года назад

    #189 thumbs uP

  • @anselmoleon5763
    @anselmoleon5763 4 года назад +1

    good morning Dave they have a sensor in the back that slightly falls out of place I called tech support at infacon and there awesome good luck to you brother

  • @RibelKashtro
    @RibelKashtro 4 года назад

    That was a crappy install all across the board. Such is the life of a refrigeration technician cleaning up another tech's shit show lol

  • @reyrodriguez1005
    @reyrodriguez1005 4 года назад

    That fieldpiece leak detector is crap

  • @kingofthecrease30
    @kingofthecrease30 4 года назад +1

    all the reviews i saw on the SLR8 say its overly sensitive and will pick up any air that moves past the sensor....inficon leak detectors are 💩

    • @NorCal-refrigeration
      @NorCal-refrigeration  4 года назад

      The SLR8 dose fine when you get used to it. But it’s false detects a bunch. The Dtek3 also false detects and is slow. H-10 is the best.

  • @IFIXCASTLES
    @IFIXCASTLES 4 года назад

    Alrighty than....

  • @josephtramutola592
    @josephtramutola592 4 года назад

    Can’t see it from my house

  • @OcRefrig
    @OcRefrig 4 года назад

    How do you know which refrigerant is in there ?
    R-22 , 407c , 422b , 422d etc. ? Or did u just yank it all , what was left , evap & use your 407c , because I believe u said u are a 407c guy. And then labeled it of course.

    • @NorCal-refrigeration
      @NorCal-refrigeration  4 года назад +4

      Yank it. I only carry 407c

    • @torosfcp
      @torosfcp 4 года назад

      @@NorCal-refrigeration why do you only carry 407c? Just curious how come you like it. Just asking...

    • @NorCal-refrigeration
      @NorCal-refrigeration  4 года назад +1

      @@torosfcp it’s what I use for R-22 replacement. It works fine and is going to be around a while. And it’s cheaper too.

    • @torosfcp
      @torosfcp 4 года назад

      @@NorCal-refrigeration thx. Yeah I agree with that. What if it's a 404a system though, you don't carry that, you don't put in 404a?

    • @NorCal-refrigeration
      @NorCal-refrigeration  4 года назад +1

      @@torosfcp I carry 407c for R-22 replacement. My van has R407c, R4040a, R134a, R410a & now R448a.

  • @OcRefrig
    @OcRefrig 4 года назад

    Like #72