Hi, I've tried to update the software on Genie S-85 XC year 2018 (Bootloader 1302967-1.7.1 and Firmware 1302966-1.9.5) via USB. The Bootloader successfully installed and during updating of Firmware DISCON, PCON main, PCON secondary and TCON secondary successfully update 100% but TCON main not updating and showing message "Sub-ECU not responding try to recovery. I've checked wiring and CAN resistance on J5 and J10 connectors, all good. The Genie have ALC-600 controllers. Can you please help me. Thanks in advance.
Coleg excelente video muy útil 🙌
Amigo un vídeo completo de maniobra con todo el tablero y sus funciones
❤️🙏🙏🙏🙏🙏🙏
Que significa 99 overload platform en genie 3384😊
Si va esplicar esplique bien
No sé puede grabar y desbloquear el equipo solo
Q desbloqueaste
Hay veces que se bloquea el boom del manlift genie z135/70 y con eso eliminas los errores 😊
Hi, I've tried to update the software on Genie S-85 XC year 2018 (Bootloader 1302967-1.7.1 and Firmware 1302966-1.9.5) via USB. The Bootloader successfully installed and during updating of Firmware DISCON, PCON main, PCON secondary and TCON secondary successfully update 100% but TCON main not updating and showing message "Sub-ECU not responding try to recovery. I've checked wiring and CAN resistance on J5 and J10 connectors, all good. The Genie have ALC-600 controllers.