Rebaring work in RCC Columns & Wall by Fischer Chemical method.

Поделиться
HTML-код
  • Опубликовано: 4 дек 2019
  • Rebaring work in RCC Columns & Wall by Fischer Chemical method. #rbsingh #civil #youtube #rebaringinrcccolumsandwall #rebaring #test #procedures #rcc #concrete

Комментарии • 179

  • @pradeepkumaryadav3859
    @pradeepkumaryadav3859 3 года назад +3

    Thank you sooo much for explaining it in a very simple way with complete details about it without leaving a single point

  • @JyotiSingh-pg8xy
    @JyotiSingh-pg8xy 2 года назад +4

    Nice video sir from Tanzania, I am civil engineer really good information..

  • @shaikshakarimulla1367
    @shaikshakarimulla1367 3 года назад +2

    Excellent dear amazing explained

  • @pradipbhattacharjee448
    @pradipbhattacharjee448 Год назад +1

    Very innovative idea..thanks 👌

  • @karmjeet3688
    @karmjeet3688 2 года назад +1

    Very good job sir

  • @deshiupaysetaiyar6537
    @deshiupaysetaiyar6537 2 года назад

    Very good information sir ji

  • @Rj14facts826
    @Rj14facts826 4 года назад +1

    Thanks for tell about depth relation with dia. Of steel bar

  • @khushbuinfracon9864
    @khushbuinfracon9864 4 года назад

    Very nice 👌👌

  • @agaaz1776
    @agaaz1776 2 года назад

    Nice Sirji.

  • @manojkumargupta9805
    @manojkumargupta9805 2 года назад

    Very nice 👌👍

  • @satyanarayanroy8294
    @satyanarayanroy8294 2 года назад

    Excellent for rebar video

  • @satishdungariya8262
    @satishdungariya8262 3 года назад

    Very good video sir

  • @manibhushansingh4489
    @manibhushansingh4489 Месяц назад

    Very nice

  • @giriprasadbammidi2798
    @giriprasadbammidi2798 2 года назад

    Can we do it for column rod, whenever there is no possibility of clink.

  • @dhammadeepdevke2334
    @dhammadeepdevke2334 3 года назад

    Long life chalega kya... Coz load will only on rebar ans concrete is just joint another column/beam

  • @anilsingh8430
    @anilsingh8430 3 года назад

    Very nice video

  • @harshamallampalli7398
    @harshamallampalli7398 3 года назад +7

    Good Content sir. But a small correction. Just like for construction of a building where structural analysis is necessary, it is equally necessary to design post installed rebar applications like these following Eurocode 2 refer Technical Report 023. Just FYI. 10times the diameter is not the right measure of depth.

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад +4

      Thank you brother for good suggestion ,, In the next video, reference was made by checking the video above what you have given .

  • @amitkumarlife5360
    @amitkumarlife5360 4 года назад

    Good video

  • @nanamarkad7832
    @nanamarkad7832 10 месяцев назад

    Can any one sugest best chemicals brand for rebaring for 18 inch cantilever beam..(this beam will also carry brick wall load)

  • @deshiupaysetaiyar6537
    @deshiupaysetaiyar6537 2 года назад

    Good👍👍

  • @indersaini513
    @indersaini513 3 года назад +1

    Mostly max. Dia bar used in bottom layer. As u told 25 dia bar taking top layer and 20 dia bar in bottom.

  • @11sudipdutta
    @11sudipdutta 4 года назад

    Very good

  • @radhe3699
    @radhe3699 Год назад

    Sir can we done rebaring in brick structure of 12 inches wall

  • @hareswarhajong7533
    @hareswarhajong7533 3 года назад

    Good method

  • @raghuveersingkumre7539
    @raghuveersingkumre7539 7 месяцев назад

    Slab ke liye beam bhi joint kar sakte hai. purane colum se please batayega sir

  • @arshadgholam2799
    @arshadgholam2799 4 года назад

    Yeh staircase ke midlanding ka steel missing tha shayed? Yeh kis project ka hai aur kaun si company kaam kar rahi hai? Dekhne mein to barha project lag raha hai.

  • @rbsinghcivilengineeringaca6777
    @rbsinghcivilengineeringaca6777  4 года назад +2

    🙏🙏🙏🙏🙏

  • @prajwalsrinivas1842
    @prajwalsrinivas1842 3 года назад +3

    Hi sir,
    Can i extend 2.5 feet rcc slab of ground floor length 30 feet just for passage of 1st floor...no loads no wall just slab for passage..
    1st floor outer walls will be on old slab itsef...

    • @PranoyRoy1991
      @PranoyRoy1991 Год назад

      Yes why not.install 4columns for load distribution

  • @civildaddy6258
    @civildaddy6258 6 месяцев назад

    Thank You Sir

  • @foodjkvlog1
    @foodjkvlog1 4 года назад

    Sir Mera gharr 3 manjil bana hua h but ground floor waale kamre m pillar nhi h 9" ki wall h or ab deewar m crack aane lage h load ki vajah se...second floor prr Piller beam dono h

  • @doctorvimalkatarmal4704
    @doctorvimalkatarmal4704 4 года назад

    good work👍

  • @amitkumarlife5360
    @amitkumarlife5360 4 года назад

    Nice

  • @diksharathore2560
    @diksharathore2560 Год назад

    Sir but humara pillar ki saria to h but wo galat 9 inch doori par h to uska load chat par aayiga to rebearing kr skte h

  • @alibasu508
    @alibasu508 3 года назад

    Sir where is this site?

  • @pradeepverma6686
    @pradeepverma6686 Год назад

    Kitne ghante baad concrete kr skte hai

  • @traininginengineering6398
    @traininginengineering6398 2 года назад +1

    Good

  • @bikashchandrabauri6139
    @bikashchandrabauri6139 9 месяцев назад

    Sir apka video main Bhahot kuch sikhne ko milta hai
    Very good sir
    Sir rebaring is code kaya hai?

  • @planningteam2666
    @planningteam2666 4 года назад

    Man gye dada

  • @ADILKHAN-gh4xg
    @ADILKHAN-gh4xg 2 года назад

    🙏

  • @asjadkhan7258
    @asjadkhan7258 3 года назад

    Column mera side may crck hai us ke liye koi achcha atreeqa batao

  • @busylife1235
    @busylife1235 2 года назад

    Sir fr that which IS CODE is followed?

  • @hafeezrehman3920
    @hafeezrehman3920 4 года назад

    Sir ap India mn e job krty hn?

  • @nanamarkad7832
    @nanamarkad7832 10 месяцев назад

    For taluka malshiras dist solapur state maharashtra ke liye koi rebar ke liye hai kya

  • @srabansingh6655
    @srabansingh6655 4 года назад

    Sir ishka load test kaise karege...

  • @bhupenparmar1523
    @bhupenparmar1523 2 года назад +1

    Nice sir

  • @keshavkumar390
    @keshavkumar390 Год назад

    Good idia

  • @anuragsarkar8842
    @anuragsarkar8842 3 года назад +1

    If people start doing rebaring this way, then believe no structure will be safe. It’s absolutely disaster how he is fixing those reinforcements, he is literally hammering them.

  • @spectrovision7466
    @spectrovision7466 Год назад

    By doing this you are missing 2 valid points .
    1. The joint doesn't become RCC for beam . It's only steel there at beam-wall interface to take care of the load .
    2. The beam doesn't get any bearing on wall .

  • @surajitdas-qx5vb
    @surajitdas-qx5vb 2 года назад

    Is chemical ko hum log bhi banate hai. Humara company ka nam VIBGYOR INC(Kolkata).

  • @6070avm
    @6070avm 2 года назад

    How many inches of steel should be inserted inside the concrete

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  2 года назад +1

      Minimum 10 dia of Steel.

    • @6070avm
      @6070avm 2 года назад

      concrete insert steel length

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  2 года назад +2

      @@6070avm minimum steel inserted in the concrete 10 X dia of Steel,
      Suppose that steel used in the columns 12mm dia , minimum requirements of steel insert of concrete 120 mm .
      maybe clear this doubt sir ji.. 👍👍

    • @6070avm
      @6070avm 2 года назад +1

      @@rbsinghcivilengineeringaca6777 Thank you sir

    • @spectrovision7466
      @spectrovision7466 Год назад

      @@rbsinghcivilengineeringaca6777 , he is asking how many inches ...gaddha mistri ban'na chahiye .

  • @silvinremedios7347
    @silvinremedios7347 5 месяцев назад

    😅❤ 0:37

  • @papiamondal9839
    @papiamondal9839 3 года назад

    Aisa chidki opar Kalam kia jasakta ha, kyoki chad ki rod sob katahoaaha,

  • @vickarttoyou9876
    @vickarttoyou9876 4 года назад

    iske baad iski testing bhi hotti h ya nhi???

  • @arpitajain6327
    @arpitajain6327 2 года назад

    What are Service charges per hole. Any contact for Indore.

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  2 года назад

      Mr. Kasi ram ji +919561425493 , Already indore madhya pradesh , mein hi hai aap is person se contact karke rate faur chemical ke bare mein pata kar sakte 👍👍

  • @Singh.RichyRich
    @Singh.RichyRich 3 года назад +3

    Sir Ji, Chemical to theek hai, Lekin hole 🕳 for 2/3 full kiya Jata hai Pehle. Jaise aapne kiya hai woh itna nahi bhra. Main bhi yehi kaam karta hoon Australia mein. Hum Hilti Use karte hain. Cleaning process bhi aapki thodi aur safai se honi chahiye thi. Brush use karke, fir blower, fir brush fir blower. Chemical anchoring is a serious business and your bond is as good as your hole cleaning. Wear ear muffs and gloves for safety reasons. Be safe and keep up the good work.

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад +1

      Very good dear , Next video me aap ki baato ka dhyan diya jaayega..
      Thank you for good suggestion..

    • @hemalpatels2016
      @hemalpatels2016 2 года назад

      Aur bhi ek bat hai ki 20 dia rod k liye drill bit bhi 20 ka hi use kiya, kya ye sahi hai??
      20 dia ka rod rebaring k liye bit kitne mm ka use karna chahiye??

    • @digantdubey8863
      @digantdubey8863 2 года назад

      @@hemalpatels2016 20mm ke rebarring ke liye 24 mm ki bit use honi chahiye

    • @nanamarkad7832
      @nanamarkad7832 10 месяцев назад

      Can any one sugest best chemicals brand for rebaring for 18 inch cantilever beam..(this beam will also carry brick wall load)

    • @Singh.RichyRich
      @Singh.RichyRich 10 месяцев назад

      @@nanamarkad7832 Hilti has quite good reputation. Better off consulting them before use.

  • @chanderpaswan1305
    @chanderpaswan1305 Год назад

    Sir conse hammer se plinth bim ,me hole ho jayega, mere pas tiger ka hammer h, but usse hole ni ho pa rha, pls help me.

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  Год назад +1

      Hilti drilling machine ya Boss drilling machine ka use Karo brother, sath mein steel ki marking jarur kare ta ki ham side me ashani se drilling kar sake.

    • @chanderpaswan1305
      @chanderpaswan1305 Год назад +1

      @@rbsinghcivilengineeringaca6777 ji , thankyou 🙏 so much sir,sir rebarring karna h, plinth Bim me, new constitution h, bathroom k liye , kya chemical use karna compulsory h, pls help me

  • @kaushiksharmah1483
    @kaushiksharmah1483 Год назад

    Good Explanation!
    But its a layman s way its done, but Rebaring is a very technical topic!
    Any connection done needs to be designed as for EC2! 10D is death trap, plz avoid!

  • @suryaraj1831
    @suryaraj1831 3 года назад

    How can we calculate rebar drill debth for formula

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад +1

      10D is taken and which is important in depth of hole , So that my steel , Dia is 20 or 25mm, Hole depth = 25×10 = 250 mm & 20×10 = 200 mm as per IS code required for rebaring work

    • @thiruvuvignesh4203
      @thiruvuvignesh4203 3 года назад

      @@rbsinghcivilengineeringaca6777
      Sir kindly tell us IS CODE no

    • @spectrovision7466
      @spectrovision7466 Год назад

      Class 5 me join karo . Multiplication sikho useless log .

  • @SaurabhKumar-uf9bj
    @SaurabhKumar-uf9bj 2 года назад

    Lekin sir cmcl lagane k bad gun rakhne par sukh jata h

  • @aamirsaifi1470
    @aamirsaifi1470 3 года назад

    Is chemical ka name aur price kya hai plz bataye🙂

  • @Ankeshkumar-jl5tk
    @Ankeshkumar-jl5tk Год назад

    Chemical ka naam kya hai

  • @Amitkumar-vb4mq
    @Amitkumar-vb4mq 4 года назад

    Chemical Ka kya nam he batiye please

  • @angadyadav1351
    @angadyadav1351 2 года назад

    R e Wall ka full form rain force ha kya sir ji

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  2 года назад +2

      दोस्त , री- वायरिंग का मतलब होता है किसी भी जगह में दोबारा स्टील बार को डालना..

    • @s.bproject1406
      @s.bproject1406 2 года назад

      Returning wall

  • @ayubshaikh96
    @ayubshaikh96 3 года назад

    thank you for video but aap kanjuse karna sikha re ho chemical ko hole ke depth me minimum 70 % fill karna hota hai ta steel andar jane k baad 100% chemical ho

  • @akilanconstructions1196
    @akilanconstructions1196 2 года назад

    Hello sir the chemical name

  • @vnxndhjf3648
    @vnxndhjf3648 3 года назад

    bottle se pahle chemical nikale Nahin sar

  • @kiranbhatia2554
    @kiranbhatia2554 Год назад

    Aise karne bricks ka weight sahan kar lega?

  • @Youbegaming2010
    @Youbegaming2010 10 месяцев назад

    Ma

  • @deepaksingh-rb5tj
    @deepaksingh-rb5tj 11 месяцев назад

    Sir iska IS Code Kya ha

  • @Tej_bharadwaj
    @Tej_bharadwaj Год назад

    Coloum ka v same process hota h?

  • @snkshorts4626
    @snkshorts4626 Год назад

    25 Mm ke rod ko fix karne ke liye to 28 mm ke bit se drill karna chahiye na hammer marne se kamjor hojata hai aur above 16 mm ke rod ke liye fisher ka chemical bahut bekar hai hilti RE 500 hona chahiye

  • @arbazinmandar7743
    @arbazinmandar7743 3 года назад +1

    ऐक बॉटल मे कितने राड होते 12mm के
    6 ईन्च अनदर

    • @s.bproject1406
      @s.bproject1406 2 года назад

      Apko krane h kya sir

    • @s.bproject1406
      @s.bproject1406 2 года назад

      Apko krane h kya sir

    • @chanderpaswan1305
      @chanderpaswan1305 Год назад

      ​@@s.bproject1406 sir plinth Bim me hole ni ho pa rha tiger hammer se, kya solution hai, pls help me

  • @shanuahmad9647
    @shanuahmad9647 3 года назад +1

    Sir kisi slab pr M25 dalni thi or galti se M20 dal gyi ho to fir solution kya hoga plz reply. M ye question ka answer kafi time se khoj rha hun plz solution provide kren.🙏

  • @Veku0007
    @Veku0007 3 года назад

    Sir muje ya chamical chahiye Kha milega

  • @angadyadav1351
    @angadyadav1351 2 года назад

    Rw wall ka full form kya hi sir ji

  • @shivshaktienterprises7183
    @shivshaktienterprises7183 4 года назад +1

    ये HILTI machin nahi

  • @deshiupaysetaiyar6537
    @deshiupaysetaiyar6537 2 года назад

    Very good work, Sir aap ka mobile number mil saktaa hai kya..

  • @cabp9
    @cabp9 4 года назад +4

    WRONG GROUTING IS CARRIED OUT. FISCHER MATERIAL IS NOT ADEQUATE.

    • @jvjv6332
      @jvjv6332 Год назад

      Why sir?

    • @shahinahmad9695
      @shahinahmad9695 Год назад

      @@jvjv6332This material is not epoxy based. It is vinyl based. Epoxy is better and appropriate for such job.

    • @pradeepshriyanvlogs
      @pradeepshriyanvlogs 11 месяцев назад

      better to use forsroc Lockfix,,Sastha and Majbooti hai... Baaki sub befaaltu ..

  • @jayeshlakum7956
    @jayeshlakum7956 4 года назад

    Bhai chemical itna daalo ki road daal ne ke baad chemical bahar aaye

    • @jskhani
      @jskhani 3 года назад

      Correct,it’s a poor work

  • @sandeerock2470
    @sandeerock2470 4 года назад

    Kya ye belivebal h

    • @jskhani
      @jskhani 3 года назад

      Ur Wala nahi, Larkin system se hona chahiye

    • @s.bproject1406
      @s.bproject1406 2 года назад

      Ji

  • @vinodkumarpatel699
    @vinodkumarpatel699 3 года назад

    प्लीज इसका रीवा रिंग डॉक्टर फिशर का रेट बताइए कितना मिलता है

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад

      Dear ismein bahut Sare product aate Hain aapko kis kam ke liye chahie, yadi crack repair ke liye aap baat kar rahe hain to near about 500 rs to 700 Rs ke near about per kg padega.

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад

      Aur yadi aap bada packet Lete Hain to is se kam rate padega.

  • @pritamchakraborty3696
    @pritamchakraborty3696 4 года назад +3

    This is an absolutely wrong method of post installed rebar grouting.
    First of all Rebar grouting methods and principles are defined by European Technical Association and not IS. Also there is no concept of 10XD. That is absolutely wrong.
    The drilled hole diameter for every rebar size is mentioned by ETA.
    The cleaning of holes need a brush cleaning along with blower.
    The way the chemical is injected is wrong. You should use a plug for that.
    You should always understand that any engineering application should not be causally taken into account.

    • @jskhani
      @jskhani 3 года назад +1

      Yes you are right. This is all poor work.

  • @chandkazi8664
    @chandkazi8664 2 месяца назад

    सही से एक्सप्लेन नहीं किया

  • @mohammedshaikh6533
    @mohammedshaikh6533 4 года назад

    Yeh chemical kha milenga?

  • @prahladkumar2269
    @prahladkumar2269 Год назад

    Name bataeye na

  • @Topnotchindustrial
    @Topnotchindustrial Год назад

    Machine hilti nhi hai bro... Koi aur company hai

  • @lachhirajak9198
    @lachhirajak9198 2 года назад

    Rebaring aise nahin hoti bhai

  • @jskhani
    @jskhani 3 года назад

    Contact me for Pull Out test

  • @thedemocratic_indian
    @thedemocratic_indian Год назад

    Aap re wiring kyu bol rahe ho

  • @IsrarKhan-ok4nt
    @IsrarKhan-ok4nt Год назад

    Firstly, it is not rewiring it is rebarbing, secondly your method of grouting is wrong, chemical is poured inside the hall at once and it should fill and come out and thirdly your grouting chemical itself is wrong.

  • @sattaking8530
    @sattaking8530 3 года назад

    Kaam करना आता नहीं है और लोगो को बता रहे है की ऐसे होती है री ribarig कितना ml केमिकल डालता है होल मे ऐसे होती है ribarig

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад

      Very good dear.. please send the correct methodology for this work...

    • @divitpatel3757
      @divitpatel3757 3 года назад

      @@rbsinghcivilengineeringaca6777
      Ye video dekh lo🤭🤭
      ruclips.net/video/GjP2dGyb4as/видео.html

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад +1

      dost hamare video aur is video mein jyada antar Nahin hai main bhi ho Sakta hai aapane Sahi tarike se video ko Dekha Nahi hai..

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад

      दोस्त हो सकता है आपको हमारा वीडियो अच्छा ना लगा हो और जो आपने भेजा है और जो हमारा वीडियो है वह लगभग 90% एक जैसा है कृपया और अधिक जानकारी के लिए आप हमारा वीडियो पूरा देखिए 🙏🙏

  • @sachinnppl293
    @sachinnppl293 4 года назад

    Ye bilkul fail method hai
    Bar ko thoka nahi jata

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  4 года назад

      Sir ji sahi method ko batao Bhai Kya hai... Civil engineering ka koi 1 methods nahi hota hai ..bahut sari method hote hai..

    • @pritamchakraborty3696
      @pritamchakraborty3696 4 года назад

      You are absolutely right. Rebar ko kabhi Thoka nahi jata.

    • @pritamchakraborty3696
      @pritamchakraborty3696 4 года назад +2

      @@rbsinghcivilengineeringaca6777 Sir aap European Organization for Technical Approvals ka report TR023 Assessment of Post-installed reinforcing bar connections padh lijiye. Waha pe likha hua hain. Ya phir www.hilti.in pe padh lijiye.

  • @chappaseetamnaidu5744
    @chappaseetamnaidu5744 4 года назад

    Very good

  • @srabansingh6655
    @srabansingh6655 4 года назад

    Nice