Rebaring work in RCC Columns & Wall by Fischer Chemical method.

Поделиться
HTML-код
  • Опубликовано: 3 ноя 2024

Комментарии • 183

  • @JyotiSingh-pg8xy
    @JyotiSingh-pg8xy 3 года назад +4

    Nice video sir from Tanzania, I am civil engineer really good information..

  • @pradeepkumaryadav3859
    @pradeepkumaryadav3859 4 года назад +3

    Thank you sooo much for explaining it in a very simple way with complete details about it without leaving a single point

  • @harshamallampalli7398
    @harshamallampalli7398 3 года назад +7

    Good Content sir. But a small correction. Just like for construction of a building where structural analysis is necessary, it is equally necessary to design post installed rebar applications like these following Eurocode 2 refer Technical Report 023. Just FYI. 10times the diameter is not the right measure of depth.

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад +4

      Thank you brother for good suggestion ,, In the next video, reference was made by checking the video above what you have given .

  • @pradipbhattacharjee448
    @pradipbhattacharjee448 2 года назад +1

    Very innovative idea..thanks 👌

  • @rabikurmi8174
    @rabikurmi8174 Месяц назад

    Sir
    Rebaring karne se ghar ka structure weak hota hai kya?

  • @shaikshakarimulla1367
    @shaikshakarimulla1367 3 года назад +2

    Excellent dear amazing explained

  • @raghuveersingkumre7539
    @raghuveersingkumre7539 11 месяцев назад

    Slab ke liye beam bhi joint kar sakte hai. purane colum se please batayega sir

  • @pradeepverma6686
    @pradeepverma6686 Год назад

    Kitne ghante baad concrete kr skte hai

  • @bikashchandrabauri6139
    @bikashchandrabauri6139 Год назад

    Sir apka video main Bhahot kuch sikhne ko milta hai
    Very good sir
    Sir rebaring is code kaya hai?

  • @dhammadeepdevke2334
    @dhammadeepdevke2334 3 года назад

    Long life chalega kya... Coz load will only on rebar ans concrete is just joint another column/beam

  • @manibhushansingh4489
    @manibhushansingh4489 5 месяцев назад

    Very nice

  • @karmjeet3688
    @karmjeet3688 3 года назад +1

    Very good job sir

  • @prajwalsrinivas1842
    @prajwalsrinivas1842 4 года назад +3

    Hi sir,
    Can i extend 2.5 feet rcc slab of ground floor length 30 feet just for passage of 1st floor...no loads no wall just slab for passage..
    1st floor outer walls will be on old slab itsef...

    • @PranoyRoy1991
      @PranoyRoy1991 2 года назад

      Yes why not.install 4columns for load distribution

  • @diksharathore2560
    @diksharathore2560 Год назад

    Sir but humara pillar ki saria to h but wo galat 9 inch doori par h to uska load chat par aayiga to rebearing kr skte h

  • @nanamarkad7832
    @nanamarkad7832 Год назад

    Can any one sugest best chemicals brand for rebaring for 18 inch cantilever beam..(this beam will also carry brick wall load)

  • @radhe3699
    @radhe3699 Год назад

    Sir can we done rebaring in brick structure of 12 inches wall

  • @deshiupaysetaiyar6537
    @deshiupaysetaiyar6537 3 года назад

    Very good information sir ji

  • @keshavkumar390
    @keshavkumar390 Год назад

    Good idia

  • @civildaddy6258
    @civildaddy6258 10 месяцев назад

    Thank You Sir

  • @DevenderSingh-vk6hp
    @DevenderSingh-vk6hp Месяц назад

    Which code 10d??

  • @indersaini513
    @indersaini513 4 года назад +1

    Mostly max. Dia bar used in bottom layer. As u told 25 dia bar taking top layer and 20 dia bar in bottom.

  • @satyanarayanroy8294
    @satyanarayanroy8294 3 года назад

    Excellent for rebar video

  • @foodjkvlog1
    @foodjkvlog1 4 года назад

    Sir Mera gharr 3 manjil bana hua h but ground floor waale kamre m pillar nhi h 9" ki wall h or ab deewar m crack aane lage h load ki vajah se...second floor prr Piller beam dono h

  • @giriprasadbammidi2798
    @giriprasadbammidi2798 2 года назад

    Can we do it for column rod, whenever there is no possibility of clink.

  • @arshadgholam2799
    @arshadgholam2799 4 года назад

    Yeh staircase ke midlanding ka steel missing tha shayed? Yeh kis project ka hai aur kaun si company kaam kar rahi hai? Dekhne mein to barha project lag raha hai.

  • @agaaz1776
    @agaaz1776 3 года назад

    Nice Sirji.

  • @spectrovision7466
    @spectrovision7466 2 года назад

    By doing this you are missing 2 valid points .
    1. The joint doesn't become RCC for beam . It's only steel there at beam-wall interface to take care of the load .
    2. The beam doesn't get any bearing on wall .

  • @Rj14facts826
    @Rj14facts826 4 года назад +1

    Thanks for tell about depth relation with dia. Of steel bar

  • @nanamarkad7832
    @nanamarkad7832 Год назад

    For taluka malshiras dist solapur state maharashtra ke liye koi rebar ke liye hai kya

  • @traininginengineering6398
    @traininginengineering6398 3 года назад +1

    Good

  • @anilsingh8430
    @anilsingh8430 3 года назад

    Very nice video

  • @bhupenparmar1523
    @bhupenparmar1523 2 года назад +1

    Nice sir

  • @anuragsarkar8842
    @anuragsarkar8842 4 года назад +1

    If people start doing rebaring this way, then believe no structure will be safe. It’s absolutely disaster how he is fixing those reinforcements, he is literally hammering them.

  • @kiranbhatia2554
    @kiranbhatia2554 2 года назад

    Aise karne bricks ka weight sahan kar lega?

  • @Tej_bharadwaj
    @Tej_bharadwaj 2 года назад

    Coloum ka v same process hota h?

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  2 года назад

      Yes brother.

    • @Tej_bharadwaj
      @Tej_bharadwaj 2 года назад

      @@rbsinghcivilengineeringaca6777 sir 2nd floor ke roof casting me 1 bich me coloum ka 3 sariya roof ke andr hi dab gya galti se rebar ke liye kitna inch andr drill karna hoga

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  2 года назад

      @@Tej_bharadwaj dear column ka steel ka dia kya hai & Slab ki thickness kya hai , please confirm

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  2 года назад +1

      10×dia of steel, Concrete mein hole karna hota hai minimum..

    • @Wealthbuilderexperts
      @Wealthbuilderexperts Месяц назад

      ​@@rbsinghcivilengineeringaca6777 we can use this method for column extension. Am I right? My column steel bars have corroded, some 16 mm bars have become the size of 10 mm. Can we use this technique for reinforcing the existing column steel bars?

  • @satishdungariya8262
    @satishdungariya8262 4 года назад

    Very good video sir

  • @Singh.RichyRich
    @Singh.RichyRich 4 года назад +3

    Sir Ji, Chemical to theek hai, Lekin hole 🕳 for 2/3 full kiya Jata hai Pehle. Jaise aapne kiya hai woh itna nahi bhra. Main bhi yehi kaam karta hoon Australia mein. Hum Hilti Use karte hain. Cleaning process bhi aapki thodi aur safai se honi chahiye thi. Brush use karke, fir blower, fir brush fir blower. Chemical anchoring is a serious business and your bond is as good as your hole cleaning. Wear ear muffs and gloves for safety reasons. Be safe and keep up the good work.

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  4 года назад +1

      Very good dear , Next video me aap ki baato ka dhyan diya jaayega..
      Thank you for good suggestion..

    • @hemalpatels2016
      @hemalpatels2016 3 года назад

      Aur bhi ek bat hai ki 20 dia rod k liye drill bit bhi 20 ka hi use kiya, kya ye sahi hai??
      20 dia ka rod rebaring k liye bit kitne mm ka use karna chahiye??

    • @digantdubey8863
      @digantdubey8863 2 года назад

      @@hemalpatels2016 20mm ke rebarring ke liye 24 mm ki bit use honi chahiye

    • @nanamarkad7832
      @nanamarkad7832 Год назад

      Can any one sugest best chemicals brand for rebaring for 18 inch cantilever beam..(this beam will also carry brick wall load)

    • @Singh.RichyRich
      @Singh.RichyRich Год назад

      @@nanamarkad7832 Hilti has quite good reputation. Better off consulting them before use.

  • @busylife1235
    @busylife1235 2 года назад

    Sir fr that which IS CODE is followed?

  • @manojkumargupta9805
    @manojkumargupta9805 3 года назад

    Very nice 👌👍

  • @chanderpaswan1305
    @chanderpaswan1305 Год назад

    Sir conse hammer se plinth bim ,me hole ho jayega, mere pas tiger ka hammer h, but usse hole ni ho pa rha, pls help me.

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  Год назад +1

      Hilti drilling machine ya Boss drilling machine ka use Karo brother, sath mein steel ki marking jarur kare ta ki ham side me ashani se drilling kar sake.

    • @chanderpaswan1305
      @chanderpaswan1305 Год назад +1

      @@rbsinghcivilengineeringaca6777 ji , thankyou 🙏 so much sir,sir rebarring karna h, plinth Bim me, new constitution h, bathroom k liye , kya chemical use karna compulsory h, pls help me

  • @kaushiksharmah1483
    @kaushiksharmah1483 Год назад

    Good Explanation!
    But its a layman s way its done, but Rebaring is a very technical topic!
    Any connection done needs to be designed as for EC2! 10D is death trap, plz avoid!

  • @arbazinmandar7743
    @arbazinmandar7743 3 года назад +1

    ऐक बॉटल मे कितने राड होते 12mm के
    6 ईन्च अनदर

    • @s.bproject1406
      @s.bproject1406 3 года назад

      Apko krane h kya sir

    • @s.bproject1406
      @s.bproject1406 3 года назад

      Apko krane h kya sir

    • @chanderpaswan1305
      @chanderpaswan1305 Год назад

      ​@@s.bproject1406 sir plinth Bim me hole ni ho pa rha tiger hammer se, kya solution hai, pls help me

  • @rbsinghcivilengineeringaca6777
    @rbsinghcivilengineeringaca6777  4 года назад +2

    🙏🙏🙏🙏🙏

  • @surajitdas-qx5vb
    @surajitdas-qx5vb 2 года назад

    Is chemical ko hum log bhi banate hai. Humara company ka nam VIBGYOR INC(Kolkata).

  • @shanuahmad9647
    @shanuahmad9647 3 года назад +1

    Sir kisi slab pr M25 dalni thi or galti se M20 dal gyi ho to fir solution kya hoga plz reply. M ye question ka answer kafi time se khoj rha hun plz solution provide kren.🙏

  • @vickarttoyou9876
    @vickarttoyou9876 4 года назад

    iske baad iski testing bhi hotti h ya nhi???

  • @SaurabhKumar-uf9bj
    @SaurabhKumar-uf9bj 2 года назад

    Lekin sir cmcl lagane k bad gun rakhne par sukh jata h

  • @arpitajain6327
    @arpitajain6327 3 года назад

    What are Service charges per hole. Any contact for Indore.

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад

      Mr. Kasi ram ji +919561425493 , Already indore madhya pradesh , mein hi hai aap is person se contact karke rate faur chemical ke bare mein pata kar sakte 👍👍

  • @deshiupaysetaiyar6537
    @deshiupaysetaiyar6537 3 года назад

    Good👍👍

  • @asjadkhan7258
    @asjadkhan7258 4 года назад

    Column mera side may crck hai us ke liye koi achcha atreeqa batao

  • @aamirsaifi1470
    @aamirsaifi1470 3 года назад

    Is chemical ka name aur price kya hai plz bataye🙂

  • @hareswarhajong7533
    @hareswarhajong7533 3 года назад

    Good method

  • @amitkumarlife5360
    @amitkumarlife5360 4 года назад

    Good video

  • @khushbuinfracon9864
    @khushbuinfracon9864 4 года назад

    Very nice 👌👌

  • @chappaseetamnaidu5744
    @chappaseetamnaidu5744 4 года назад

    Very good

  • @mayurmirchandani3411
    @mayurmirchandani3411 Месяц назад

    Ye hilti ka drill machine nahe he

  • @ADILKHAN-gh4xg
    @ADILKHAN-gh4xg 3 года назад

    🙏

  • @planningteam2666
    @planningteam2666 4 года назад

    Man gye dada

  • @pritamchakraborty3696
    @pritamchakraborty3696 4 года назад +3

    This is an absolutely wrong method of post installed rebar grouting.
    First of all Rebar grouting methods and principles are defined by European Technical Association and not IS. Also there is no concept of 10XD. That is absolutely wrong.
    The drilled hole diameter for every rebar size is mentioned by ETA.
    The cleaning of holes need a brush cleaning along with blower.
    The way the chemical is injected is wrong. You should use a plug for that.
    You should always understand that any engineering application should not be causally taken into account.

    • @jskhani
      @jskhani 4 года назад +1

      Yes you are right. This is all poor work.

  • @alibasu508
    @alibasu508 4 года назад

    Sir where is this site?

  • @ayubshaikh96
    @ayubshaikh96 4 года назад

    thank you for video but aap kanjuse karna sikha re ho chemical ko hole ke depth me minimum 70 % fill karna hota hai ta steel andar jane k baad 100% chemical ho

  • @doctorvimalkatarmal4704
    @doctorvimalkatarmal4704 4 года назад

    good work👍

  • @vinodkumarpatel699
    @vinodkumarpatel699 3 года назад

    प्लीज इसका रीवा रिंग डॉक्टर फिशर का रेट बताइए कितना मिलता है

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад

      Dear ismein bahut Sare product aate Hain aapko kis kam ke liye chahie, yadi crack repair ke liye aap baat kar rahe hain to near about 500 rs to 700 Rs ke near about per kg padega.

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад

      Aur yadi aap bada packet Lete Hain to is se kam rate padega.

  • @6070avm
    @6070avm 2 года назад

    How many inches of steel should be inserted inside the concrete

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  2 года назад +1

      Minimum 10 dia of Steel.

    • @6070avm
      @6070avm 2 года назад

      concrete insert steel length

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  2 года назад +2

      @@6070avm minimum steel inserted in the concrete 10 X dia of Steel,
      Suppose that steel used in the columns 12mm dia , minimum requirements of steel insert of concrete 120 mm .
      maybe clear this doubt sir ji.. 👍👍

    • @6070avm
      @6070avm 2 года назад +1

      @@rbsinghcivilengineeringaca6777 Thank you sir

    • @spectrovision7466
      @spectrovision7466 2 года назад

      @@rbsinghcivilengineeringaca6777 , he is asking how many inches ...gaddha mistri ban'na chahiye .

  • @papiamondal9839
    @papiamondal9839 3 года назад

    Aisa chidki opar Kalam kia jasakta ha, kyoki chad ki rod sob katahoaaha,

  • @angadyadav1351
    @angadyadav1351 3 года назад

    R e Wall ka full form rain force ha kya sir ji

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад +2

      दोस्त , री- वायरिंग का मतलब होता है किसी भी जगह में दोबारा स्टील बार को डालना..

    • @s.bproject1406
      @s.bproject1406 3 года назад

      Returning wall

  • @hafeezrehman3920
    @hafeezrehman3920 4 года назад

    Sir ap India mn e job krty hn?

  • @snkshorts4626
    @snkshorts4626 2 года назад

    25 Mm ke rod ko fix karne ke liye to 28 mm ke bit se drill karna chahiye na hammer marne se kamjor hojata hai aur above 16 mm ke rod ke liye fisher ka chemical bahut bekar hai hilti RE 500 hona chahiye

  • @cabp9
    @cabp9 4 года назад +4

    WRONG GROUTING IS CARRIED OUT. FISCHER MATERIAL IS NOT ADEQUATE.

    • @jvjv6332
      @jvjv6332 2 года назад

      Why sir?

    • @shahinahmad9695
      @shahinahmad9695 Год назад

      @@jvjv6332This material is not epoxy based. It is vinyl based. Epoxy is better and appropriate for such job.

    • @pradeepshriyanvlogs
      @pradeepshriyanvlogs Год назад

      better to use forsroc Lockfix,,Sastha and Majbooti hai... Baaki sub befaaltu ..

  • @silvinremedios7347
    @silvinremedios7347 9 месяцев назад

    😅❤ 0:37

  • @srabansingh6655
    @srabansingh6655 4 года назад

    Nice

  • @Ankeshkumar-jl5tk
    @Ankeshkumar-jl5tk Год назад

    Chemical ka naam kya hai

  • @srabansingh6655
    @srabansingh6655 4 года назад

    Sir ishka load test kaise karege...

  • @vnxndhjf3648
    @vnxndhjf3648 3 года назад

    bottle se pahle chemical nikale Nahin sar

  • @deepaksingh-rb5tj
    @deepaksingh-rb5tj Год назад

    Sir iska IS Code Kya ha

  • @suryaraj1831
    @suryaraj1831 4 года назад

    How can we calculate rebar drill debth for formula

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  4 года назад +1

      10D is taken and which is important in depth of hole , So that my steel , Dia is 20 or 25mm, Hole depth = 25×10 = 250 mm & 20×10 = 200 mm as per IS code required for rebaring work

    • @thiruvuvignesh4203
      @thiruvuvignesh4203 3 года назад

      @@rbsinghcivilengineeringaca6777
      Sir kindly tell us IS CODE no

    • @spectrovision7466
      @spectrovision7466 2 года назад

      Class 5 me join karo . Multiplication sikho useless log .

  • @Topnotchindustrial
    @Topnotchindustrial Год назад

    Machine hilti nhi hai bro... Koi aur company hai

  • @akilanconstructions1196
    @akilanconstructions1196 3 года назад

    Hello sir the chemical name

  • @Veku0007
    @Veku0007 3 года назад

    Sir muje ya chamical chahiye Kha milega

  • @chandkazi8664
    @chandkazi8664 6 месяцев назад

    सही से एक्सप्लेन नहीं किया

  • @deshiupaysetaiyar6537
    @deshiupaysetaiyar6537 3 года назад

    Very good work, Sir aap ka mobile number mil saktaa hai kya..

  • @angadyadav1351
    @angadyadav1351 3 года назад

    Rw wall ka full form kya hi sir ji

  • @Amitkumar-vb4mq
    @Amitkumar-vb4mq 4 года назад

    Chemical Ka kya nam he batiye please

  • @IsrarKhan-ok4nt
    @IsrarKhan-ok4nt Год назад

    Firstly, it is not rewiring it is rebarbing, secondly your method of grouting is wrong, chemical is poured inside the hall at once and it should fill and come out and thirdly your grouting chemical itself is wrong.

  • @shivshaktienterprises7183
    @shivshaktienterprises7183 4 года назад +1

    ये HILTI machin nahi

  • @sandeerock2470
    @sandeerock2470 4 года назад

    Kya ye belivebal h

    • @jskhani
      @jskhani 4 года назад

      Ur Wala nahi, Larkin system se hona chahiye

    • @s.bproject1406
      @s.bproject1406 3 года назад

      Ji

  • @lachhirajak9198
    @lachhirajak9198 2 года назад

    Rebaring aise nahin hoti bhai

  • @jayeshlakum7956
    @jayeshlakum7956 4 года назад

    Bhai chemical itna daalo ki road daal ne ke baad chemical bahar aaye

    • @jskhani
      @jskhani 4 года назад

      Correct,it’s a poor work

  • @prahladkumar2269
    @prahladkumar2269 2 года назад

    Name bataeye na

  • @mayankgunjan85
    @mayankgunjan85 3 года назад

    Kaam करना आता नहीं है और लोगो को बता रहे है की ऐसे होती है री ribarig कितना ml केमिकल डालता है होल मे ऐसे होती है ribarig

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад

      Very good dear.. please send the correct methodology for this work...

    • @divitpatel3757
      @divitpatel3757 3 года назад

      @@rbsinghcivilengineeringaca6777
      Ye video dekh lo🤭🤭
      ruclips.net/video/GjP2dGyb4as/видео.html

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад +1

      dost hamare video aur is video mein jyada antar Nahin hai main bhi ho Sakta hai aapane Sahi tarike se video ko Dekha Nahi hai..

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад

      दोस्त हो सकता है आपको हमारा वीडियो अच्छा ना लगा हो और जो आपने भेजा है और जो हमारा वीडियो है वह लगभग 90% एक जैसा है कृपया और अधिक जानकारी के लिए आप हमारा वीडियो पूरा देखिए 🙏🙏

  • @mohammedshaikh6533
    @mohammedshaikh6533 4 года назад

    Yeh chemical kha milenga?

  • @Youbegaming2010
    @Youbegaming2010 Год назад

    Ma

  • @thedemocratic_indian
    @thedemocratic_indian Год назад

    Aap re wiring kyu bol rahe ho

  • @jskhani
    @jskhani 4 года назад

    Contact me for Pull Out test

  • @sachinnppl293
    @sachinnppl293 4 года назад

    Ye bilkul fail method hai
    Bar ko thoka nahi jata

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  4 года назад

      Sir ji sahi method ko batao Bhai Kya hai... Civil engineering ka koi 1 methods nahi hota hai ..bahut sari method hote hai..

    • @pritamchakraborty3696
      @pritamchakraborty3696 4 года назад

      You are absolutely right. Rebar ko kabhi Thoka nahi jata.

    • @pritamchakraborty3696
      @pritamchakraborty3696 4 года назад +2

      @@rbsinghcivilengineeringaca6777 Sir aap European Organization for Technical Approvals ka report TR023 Assessment of Post-installed reinforcing bar connections padh lijiye. Waha pe likha hua hain. Ya phir www.hilti.in pe padh lijiye.

  • @11sudipdutta
    @11sudipdutta 4 года назад

    Very good

  • @amitkumarlife5360
    @amitkumarlife5360 4 года назад

    Nice