With regards and respect to your service In ABB inverter model ACS580 we have error 6581 During continuous operation, it gives this error every three hours, and in case of fault, the inverter is turned off. please guide me Of course, it goes without saying that we have also done a factory reset Thank you
F0101 to F0199 and F0201 to F0299 are all system errors and no corrective action listed other than to contact your ABB rep. Please contact our ABB product manager at 800-337-1720 for further assistance with these particular errors.
The F3381 fault is "Output Phase Loss." This means the motor connections are open and the drive doesn't see any current on 1 or all 3 output phases. Check your motor connections between the drive and motor junction box for broken wiring. Check the motor for ground insulation as well. A motor leaking to ground bad enough but not shorted can make the drive do random faults or flag a missleading fault. A good motor will measure at least 10-100 megg ohms to ground or higher @ 1000 volts. 1-10 megg ohms to ground is kind-of-a maybe zone, maybe it cause trouble, maybe it won't. Less than 1 megg ohm to ground is a definite trouble zone with most modern drives. If motor checks ok, try a different motor. Is there any disconnect devices (Disconnect Switch, or Contactors) between motor and drive? Let us know what you find.
Please help me to solve warning : AFE1 AUXILIARY CODE 0000 0000 Emergency stop (off2) Emergency stop command (off2) received Please help to solve above warning
can we perform fault test to abb acs880?...i just want to make sure that cantact RO3(fault) energize..
With regards and respect to your service
In ABB inverter model ACS580 we have error 6581
During continuous operation, it gives this error every three hours, and in case of fault, the inverter is turned off.
please guide me
Of course, it goes without saying that we have also done a factory reset
Thank you
Hello
Can you help me?
Hi! Recently we installed a acq-580-04 in our plant. It works about 5/10 minutes and show 5681 fail. What can we do to solution it?
If VFD tripped by earth leakage fault,what can i do?motor and its power cable IR value 15G Ohm
Please help ABB ACH580 SHOWING CHECK CONNECTION ON PLC SHOWING VDF TRIP MODE
warning in ACS880 INV run enable missing. How do I resolve ?
Plz how can I get my ABB 580ACQ back to automatic. Its just quite not even a fault light on the buttons
How do I reset alarm fault 4981 on ABB VFD Ach580 . external temperature 1 too high
Please help solve the problem fault 5093, ACDrive-ACS580 , 7.5kw
Hi how can i fix it
Memory unit FW load failed FB14
Memory unit is inserted and compatible, but FW can't be loaded
acs580-01 drive frame R0 from R5 Fault 7086
Plz give me solution this problem
The drive I'm working on is showing Fault 5093 mismatching ID and is not resetting.
Hello
Can you help me?
My acs 550 drive is showing code F0101 how to remove this fault
F0101 to F0199 and F0201 to F0299 are all system errors and no corrective action listed other than to contact your ABB rep. Please contact our ABB product manager at 800-337-1720 for further assistance with these particular errors.
My ACS 880 drive is showing code F 3381 how can i do of can run?
The F3381 fault is "Output Phase Loss." This means the motor connections are open and the drive doesn't see any current on 1 or all 3 output phases. Check your motor connections between the drive and motor junction box for broken wiring. Check the motor for ground insulation as well. A motor leaking to ground bad enough but not shorted can make the drive do random faults or flag a missleading fault. A good motor will measure at least 10-100 megg ohms to ground or higher @ 1000 volts. 1-10 megg ohms to ground is kind-of-a maybe zone, maybe it cause trouble, maybe it won't. Less than 1 megg ohm to ground is a definite trouble zone with most modern drives. If motor checks ok, try a different motor. Is there any disconnect devices (Disconnect Switch, or Contactors) between motor and drive? Let us know what you find.
Please help me to solve warning : AFE1
AUXILIARY CODE 0000 0000
Emergency stop (off2)
Emergency stop command (off2) received
Please help to solve above warning
My VFD is ACH580-1 .am presently having alarm Fault 4981 .motor temperature PTC external temperature 1 too high
Ach580 vfd fault 7583 not reset
plz how to language change. china to English
How this is abb drive in 73f0 error
plz help me abb vfd acs580 fault code 5093 id miss match
how to clear fault 5093 id miss match many vfd this problam
The drive I'm working on is showing Fault 5093 mismatching ID and is not resetting.
Please help solve the problem fault 5093 , ACDrive - ACS580 , 90kw
Hello
Can you help me?
Hi! If you need immediate assistance, please call our experts at 800-575-5562 or send an email to sales@galco.com.