Hi, thank you for this video it helped me a lot. Im trying to set up a inspection tool to look for random contamination can you give me an example of what tools can i use? i've tried with brightness with no sucess. I apprieciate all your inputs!
HI Sang, Actual value for LH part is in the cell G18 and RH part is in the cell G37. Low limit and High limit are set using "Inrange" command in I18 cell and I37 cell.
@@nethiadi7468 I have done it, Thanks so much, Good luck and Good health and if you are free, please make more videos like useful this. Furthermore, Did you used to guide for Robots with vision Cognex?
@@LamNguyen-um4tq Thanks for your appreciation, I will post more videos regularly. Yes I did vision to guide robots, do you have any doubts on that leave a comments regarding robot guidance .
@@nethiadi7468 Yes i having a project regarding GP7 yaskawa robots. that is a requirement that the output data from cognex vision will send to robot system for controlling robot. Can you any suggestion about this problem? Thanks
HI Ken, Vision Capture fail conditions are absence of air wick cap and measurement of air wick cap. Please refer the G18 cell, 1. If the cell value G18 and G37 is above 95, then it is fail. 2. If the cell value G18 and G37 is below 90, then it is Pass.
Hi, thank you for this video it helped me a lot.
Im trying to set up a inspection tool to look for random contamination can you give me an example of what tools can i use? i've tried with brightness with no sucess. I apprieciate all your inputs!
HI Jean,
Try with Blob tool instead of using brightness tool, Blob tool will detect random contamination if we set the parameters correctly.
Hello, nice Video!. I got a question. Is it possible to display the result of the distance of pixels in millimeters? Sorry for my bad English.
Hi Selim,
Use this link to convert pixel value into mm value using Field of View and Camera Resolution.
ruclips.net/video/LTFKhAXxot0/видео.html
Hello. nice video. Could you show me how to use surface fx? i am new to spreadsheet.
Thanks , I will upload surface FX concept video soon.
ruclips.net/video/q-9xQb7k5PE/видео.html
Hi C N use this above link for surface FX Program Concept...!
the backgroud music is very comfortable
Hi taoyaneryuanlun5555, Thanks !!we will maintain these type of comfortable background music in upcoming videos
How did you create error free ? cell J18
Using Errfree command, we can get error free ouput
@@nethiadi7468 i also cant do like you. you do too fast:(((
@@nethiadi7468 What is the cell with I18?
@@LamNguyen-um4tq Thanks for your feedback , I will slow down my speed in future video.
@@LamNguyen-um4tq Cell I18 is result status for Distance value using "InRange" command .
I cant see any link among three cells including low limit, actual limit, high limit. Please explain to me about this. Thank so much
HI Sang,
Actual value for LH part is in the cell G18 and RH part is in the cell G37.
Low limit and High limit are set using "Inrange" command in I18 cell and I37 cell.
@@nethiadi7468 I have done it, Thanks so much, Good luck and Good health and if you are free, please make more videos like useful this. Furthermore, Did you used to guide for Robots with vision Cognex?
@@LamNguyen-um4tq Thanks for your appreciation, I will post more videos regularly.
Yes I did vision to guide robots, do you have any doubts on that leave a comments regarding robot guidance .
@@nethiadi7468 Yes i having a project regarding GP7 yaskawa robots. that is a requirement that the output data from cognex vision will send to robot system for controlling robot. Can you any suggestion about this problem? Thanks
@@LamNguyen-um4tq Using TCP communication to send data from camera to Robot .
I saw some is ok.. Why vision capture fail.. Who can tell me?
HI Ken, Vision Capture fail conditions are absence of air wick cap and measurement of air wick cap.
Please refer the G18 cell,
1. If the cell value G18 and G37 is above 95, then it is fail.
2. If the cell value G18 and G37 is below 90, then it is Pass.
That mean that fail is your measure height?
Yes that fail is the measurement of air wick cap height fail.
I did not understand to ERROR FREE. Did you skip that?
@ugurtezcan4085 Yes, I skipped that
Can you explain me that how does it work?