जानकारी के लिए हमें जरूरत है इसकी शिकायत के लिए हमें इसके पेमेंट बताएं क्या इसका क्या पर्याय लग सकता है और 3 किलो वाट की व्यक्ति हमें लेनी है 9660 गांव में 1599 नंबर है इस पर हम से कॉल करें हमें यह भी अपडेट चाहती है इसके लिए हमसे संपर्क करें
very nice sir sahi she SB smj a gya सर मेरी एक आपसे निवेदन हे की आप इसी डेल्टा vfd का पुश बटन द्वारा मोटर की स्पीड को कम और तेज कर सके ऐसा वीडियो बनाये please sir......
hi when you shut down the entire system, will the program still remain in memory and just start the motor with the external potentiometer? how do you program it? thanks for you help
For relay output, is it just Live coming out going to light or is it both live and neutral? U got two wires coming out for relay out put, what they for?
Nice video Sir. Ager aap diagram bhi bana kr samjhate or bhi achha lagta or concept bhi clear hota. VFD k input terminal k uoper to black color k dip switches hein us k baare me aap ne nahi btaya? Kiya yeh basic parameter setting hei kisi bhi motor ko start krne k liye? Thanks
thanks for your compliment farhim ji next time apki baat ka dhyan rakha jayega :) ji yeh sab basic parameter hain od DIP switch Avi/aci mode k liye woh jo apke pot ko currentmode or volt mode k liye variable banata hai
@@TeckyBuzz ,??? 325×3 =975 panal ka watt ( LUBi) vfd HEY to 0.37/1.hp 0.75/1 hp Ac sumbesabe chalegakinahi sir kiu yey pupm to (0.37 /1hp) ye chalega a sir
Tell me sir delta drive reverse and forward two different speed variation one spped is 30 Hz another speed is 100 hz both directions push button controlling
agar ap apni vfd 1 hp ki lete ho toh usme company se 1 hp ki motor ki values phele se aati hai same ese hi 2,3, 5 sab ka hai agar ap 1 hp ki drive se 0.5hp ki motor operate karoge tab apko parameter chnge karne padenge.
sir, मोटार लाईट और सोलर पे है सबेरे और बारिश के दिनो मे चल नही रहा है . पहिले लाईट पे चलने के बाद हि सोलर पे चल रहा है . मोटर डायरेक्ट सोलर पे उठा नही रही है . VFD DRIVE :- DELTA C 200 2 hp three phase ac lubi motor .freq50 hz set. works well on ac current . but on solar gives only 35 hrz. panel 180 wx10=1800w
sir, plc ki analog output programming mein jo values data register mein store hoti hein d1116 mein un ko kisi device jaisa ka vfd se kis tarah connect karta hein kya data register ki values ko compare karna hota ha
@@TeckyBuzz i know you are indian but you can aid me by informations at least and if you have spare parts we can get the way to transfere it to egypt my watts up 0201001749846
agar apke pass catelog hai parameter ka / guide toh aap usme three wire mode ki parameter apne hisab se feed kar dien k apko 3 wire m kon sa mode on karna hai
Sir mera vfd parameter setting me kuch hu he ki mera vfd on hota he pura sacal ke bad automatic off hana chaye to nahe hota he kabhi kabar hota he kabhi nahi hota he to kya asa koei parameter he ki ese band kara ja sakta he
I have questions regarding Delta vfd,vfd goes on run mode but actually not show frequency on keypad and vtg also not shown on U V W terminal... Why..? Plz reply
मैं काफी दिनों से vfd की सही जानकारी लेना चाह रहा था आपकी वीडियो देख कर सर् अब मुझे कोई प्रॉब्लम नही होगी थैंक्स सर्
Sir aap kisi se bhi saral video of BF
Veri good
जानकारी के लिए हमें जरूरत है इसकी शिकायत के लिए हमें इसके पेमेंट बताएं क्या इसका क्या पर्याय लग सकता है और 3 किलो वाट की व्यक्ति हमें लेनी है 9660 गांव में 1599 नंबर है इस पर हम से कॉल करें हमें यह भी अपडेट चाहती है इसके लिए हमसे संपर्क करें
One of the best chanel for plc knowledge , thanks sir ,,
Thanks for your appreciation
bhut khub very nice..... helping like a teacher,,,,, i am very glad to see it and also very informative :)
Bahut achha laga vidio or mai bahut kuchh shikh liye
very nice sir sahi she SB smj a gya
सर मेरी एक आपसे निवेदन हे की आप इसी डेल्टा vfd का पुश बटन द्वारा मोटर की स्पीड को कम और तेज कर सके ऐसा वीडियो बनाये
please sir......
Push button se speed increases decrease ruclips.net/video/8T_CdTd6y8Q/видео.html
बहुत अच्छे सर् वीडियो अच्छा बनाई hai
Hi sir. Very nice way of explaining.
सुन्दर प्रस्तुति
Thank you sir for your contribution
Buhat khoob bhai
bahut bahut shukriya sir is video k liye
Sir supperr
Bahut achchaa ..
Tq
good sir,
please share more and more videos on delta plc
Very Help full video sir
Sir aap bahit hi achha bataye h
Hello sir sap bahut achhe tarike see samjhate h
Informative video sir 🙏
Thank you sir
Useful video thanks for sharing
Very good understand
Nice explanation,,, How to control drive through analog sensor For pid control
i will make soon
@@TeckyBuzz currently am facing issue with C200MODEL DELTA 2hp not reset the drive not able to run even in external POT
Can you help me
@@kiranchoudhari4717 what?
@@kiranchoudhari4717 dm me on my
instagram
Bahot bhadiya sir
भाई एक question tha
Ager vfd ke output me MCB ya relay lagaye to kya wo work karegi
yes
Indicater ka wiring bataye nahi Sir baki sab thik tha bahut achhe se majhaye mujhe bhi achha laga but last me indicater ka wiring nahi bataye
Very good sir
Dear sir video was informetive .
Just we want to know how to wire stop. Start, jod pls share
watch full you will get all your answers
Very Nice
Nice explanation
Its good Job boss.. Tnxxxx
Zabardast
Very nice
hi when you shut down the entire system, will the program still remain in memory and just start the motor with the external potentiometer? how do you program it? thanks for you help
Thanks bro
Nice video
very good explain sir
thnku sir
Nice sir thank you for information
For relay output, is it just Live coming out going to light or is it both live and neutral? U got two wires coming out for relay out put, what they for?
yes its 220v single phase supply
Tecky Buzz but you got two wires coming out. One out of RA and other RC. what’s these two wires for?
I have added a braking resistor to my Delta 'S' series VFD. Do I need to change any parameters in software to optimize? thanks
Very good video sir motor 2 second on 2 second off continue peramiter setting bataaaao sir
BAHUT GOOD SIR JI I AM FROM NEPEL.
tanks im from indonesia
Good
Sir inverter repairing pr video upload kary thanks
Sir kya VFD se domestic load run kr sakte hai
kabhi try ni kiya 😀 waise 3 phase motor sumersible pump chala sakte hain
Nice
Can u tell me of similar make but of 20hp induction motor air compressor which VFD can be best used???
Omron ABB Delta all these VFDs are best and use 3 phase Input /3 phase out model
Nice video Sir. Ager aap diagram bhi bana kr samjhate or bhi achha lagta or concept bhi clear hota.
VFD k input terminal k uoper to black color k dip switches hein us k baare me aap ne nahi btaya?
Kiya yeh basic parameter setting hei kisi bhi motor ko start krne k liye?
Thanks
thanks for your compliment farhim ji
next time apki baat ka dhyan rakha jayega :)
ji yeh sab basic parameter hain
od DIP switch Avi/aci mode k liye woh jo apke pot ko currentmode or volt mode k liye variable banata hai
Bro my drive port got full frequency at half turn of potentiometer problem. What program paramete i can change to solve this problem
good explanation, is the green lamp that becomes active 24 volts or 220 volts? If it is 220 volts, is the relay in series with the mains voltage?
yes
Sir Solar panel and vfd se kiya koi sa vi sumbesabe A/c 0.37.1 hp or .75.1 hp ) yea sumbesabe chala ya ja sakta hai kya sir
solar inverter ki rated power zayda honi chahiye
@@TeckyBuzz ,??? 325×3 =975 panal ka watt ( LUBi) vfd HEY to 0.37/1.hp 0.75/1 hp Ac sumbesabe chalegakinahi sir kiu yey pupm to (0.37 /1hp) ye chalega a sir
inverter ki rating kya hai
@@TeckyBuzz ??? Sir main key sey patalaga un inveter ka reting sir
Reting ka ek vidio banaeye sir
Sir
Can I use 220V AC lamp at RA & RC terminal.(Delta M series VFD.)
yes you can
Thanks sir
Sir kia is controller se ghar ki ac supply chala sakte hai ?
never tried :D
Please bro make a video on Greenfoss Vfd.
sorry is waqt mere pass greenfoss vfd nahi hai
Ok thanks sir
Sir thanking you appreciate your videos sir how much frequency increase maximum
50hz
VFD kis liye use karte hai
speed ko kam zayda karne k liye
Sir how to increase torque in VFD series drive Or what is parameters 6.3/6.4/6.5/or 7.2
Sir isme, input, or out put keliye contractor ka istmal kar sakte hai, or kitna capacity ka motor istmal kar sakte hai
its is only for 1 hp motor other model are avail on their rating
yes u can use contractor by connecting through relay
3 hp tak Mai lga kr Diya Hu 120 hp Ka drive bhi lga kr diye the par Mai uska wiring nhi Dekha tha
Thanks
Tell me sir delta drive reverse and forward two different speed variation one spped is 30 Hz another speed is 100 hz both directions push button controlling
sir maltifaction spped me vfd by time off karana hee
use multi mode
sir, need learn 3wire, two push button start/stop connection.
Sir sabhi controller ka setting same hota hai nahi to pramukh automation 3hp ke moter name plate ke setting ka video bnao iska chalan jiyda hai
agar ap apni vfd 1 hp ki lete ho toh usme company se 1 hp ki motor ki values phele se aati hai same ese hi 2,3, 5 sab ka hai
agar ap 1 hp ki drive se 0.5hp ki motor operate karoge tab apko parameter chnge karne padenge.
Sir mere Pas pramukh automation ka 5hp ka single fase ka drive hai ab mere ko 3hp ka water pump chlana hai iski puri jankari btaiye sir Ji
plz share its image on my email
sir,
मोटार लाईट और सोलर पे है
सबेरे और बारिश के दिनो मे चल नही रहा है .
पहिले लाईट पे चलने के बाद हि सोलर पे चल रहा है . मोटर डायरेक्ट सोलर पे उठा नही रही है .
VFD DRIVE :- DELTA C 200
2 hp three phase ac lubi motor .freq50 hz set. works well on ac current . but on solar gives only 35 hrz.
panel 180 wx10=1800w
Sir eot Crain me 3hp ki draiv Crain of time me kuch time bad trip ho rrhi
check for over load
Isme 3 phase submarcible chal sakta hai kya
yes
@@TeckyBuzz koi problem to nhi hoga
rating parameter feed kar k
sir, plc ki analog output programming mein jo values data register mein store hoti hein d1116 mein un ko kisi device jaisa ka vfd se kis tarah connect karta hein kya data register ki values ko compare karna hota ha
analog value ki sacling wali video dekhiye hope smjh a ajayega
Sir ji plc programming pr bhi video banao
Sir Kia is VFD sy A/C ka DC compressor Chala saktey Hain.
yes use rated vfd for the motor
Sir agar vfd off Karne motor dhire dhire band Hoti h quick stop Karne ke liye kon se parameter mein jaien
de acc time m
Thanks
do you have any information and spare parts of delta vfd pu01 and vfd v015m43b please
delhi
@@TeckyBuzz i know you are indian but you can aid me by informations at least and if you have spare parts we can get the way to transfere it to egypt
my watts up 0201001749846
plz send me photos of your device or spare parts on my email id then i will send you with price
@@TeckyBuzz this is my watts 0201001749846
how can i send you
this is my watts and telegram
@@ibrahimfadl8721 email me on teckybuzz@gmail.com
these two wire for indictor supply ( green one) in series with suply
Sir 3 phases 5hp motor chalasakty hy Kay sir..
yes lkin vfd ki rating 5 hp honi chahiye
Some MCC panel inside communicating type VFD install so there they given one selector for BYPASS or VFD why given that type selector
Sir aur video banaye sir.
Sir price kya hai
sir vfd se alag - alag rpm me spindle ya koi motor chala
koshish karunga next video m apko practical kar k dekhaun abhi m out od station hoon so stay tuned
Bhai sahab jaise control on karti Hain to motor running wali basti lambodara nahin hoti hai per stoppage wali Patti download
Hello sir namaskar sir ji ek banner r58 senosor ki setting ke uper ek video banao
Sir parameter me speed Kaise banata hai Jankari chahiye tha I Luv Kush ka kahan se khulega parameter Major lock laga deta woh
Sir invd Gd model ka 3wire control to batadain
agar apke pass catelog hai parameter ka / guide toh aap usme three wire mode ki parameter apne hisab se feed kar dien k apko 3 wire m kon sa mode on karna hai
Sir plz provide link for Mitsubishi and omron plc software download. Thanks.....
Can VFD run 1 hp submersible pump ???
read subermesible pump rating
Plz call sir 8896086771
Sir show the indicator wiring connection one wire is coming from relay and from where the another wire is coming????
+ve supply
sir VFD drive control wiring aur peramier k bare Mai PURA detail Mai Shamjaye
My channel moving plzzzzz
Delta vfd parameter setting ruclips.net/video/X8fjiZXXhUk/видео.html
4 to 20 connection and parameters samjayena please sir
Pid valu
Bhai plz reply.. ye drive kaha milegi. Plz bhai kis ko bhi pata ho plz. Mujhe bataye... Reply plz
kha se ho aap
delhi m bhagirat palace ya online le ko amazon se
Thank you so much mere bhai
Mein faridabad se hu
Is ka models kya hai aap ke video me drive
Sir mera vfd parameter setting me kuch hu he ki mera vfd on hota he pura sacal ke bad automatic off hana chaye to nahe hota he kabhi kabar hota he kabhi nahi hota he to kya asa koei parameter he ki ese band kara ja sakta he
reset kar do
I have questions regarding Delta vfd,vfd goes on run mode but actually not show frequency on keypad and vtg also not shown on U V W terminal...
Why..? Plz reply
do you have its manual?
step 1
00.02> 10 ok
for reset
00.03> 1 for actual frequency output
Drive not goes on factory reset I try it (err) like shows
Yes
which model you are using and also tell me you are using single to 3 phase
Hamse seting nhi ho pa rha hai dimak Ka dahi ho gya hai
Moter Ka bhi details dalna padta h vo padosi batayega kya sir
factory installed hote hain if you are using same rated motors
Mai mp ka hu vfd repering karana hai mp me kaha hoga mujhe batay
plz contact to service center
Tenk full alarm or perametar se VFD kese band kare
limit switch se
how to set forward and reverse value
Could you do this video in english
ok
Sir vfd m delta come. Fikvency program video banaao
Potential Kitna watt ka Hona chahye
Normal 5w ka le lo
Vfd perameter manual chahiye pls give me sir
online avail hai download kar lo
Sir Ra RB RC Kay hai
Sir mai nepal se hu mujhe paragane karne sikhana hi aap apna whtsapp number deyjye