I have one doubt sir DAIKIN vrv-3 indoor ducted unit set point -16 cut off the valve and set point -30 cut off the valve but set -24 can't cut off the valve more cooling the off what is the issue sir recently replaced EEV
I have one doubt sir DAIKIN vrv-3 indoor ducted unit set point -16 cut off the valve and set point -30 cut off the valve but set -24 can't cut off the valve more cooling the off what is the issue sir recently replaced EEV
Hi, my house unit is also having this issue but it is not happening daily, currently 3 weeks. Why is this so? Do you help to do checks? We used to have this issue in 2021 and Daikin is unable to find out root cause till they changed the entire PCB outdoor. Before this, they changed the valve indoor. What is the impact of not fixing this F4 alarm?
previously daikin collected data for 1 full week and cannot find a conclusion till they changed the PCB outdoor. Now this issue comes back again but not on a daily basis. However there is still aircon during the blinking light period. After we turn on and off, the light stopped blinking.
Hi I have problems putting in back my blower wheel into the shaft for my mitsubishi starmex aircon. Previously was stuck and I took it out, maybe I didnt screw the shaft properly. But now it could not be put in properly. Thanks. Is there any way to put it back smoothly?
@@BonMj Hi thanks for the fast reply, but I tried all angle plus putting lubricant, the blower wheel can only go in half the shaft, I see through the hole of the blower wheel and there is nothing stuck... feel the shaft and visual check also dont seem to have any protruding...
Hello Boj hope you well Thanks for the video . Is it same for the vrv3 ?. Please how do I know if example a error code appear on the control board , is the fault will be in indoor unit or at outdoor unit (condenser). Many thanks T.Matib
@@BonMj Hello Thank you for replying to me ,the error code is F4 on VRV3. Also in general when I get error code flashing on controller how do I know is a fault on outdoor unit or on indoor unit. Many thanks Have good day Bon . T.Matib
Hello Boj I'm having trouble on this vrv3 with code error E2 so my read resistance is between white and red is 12mega ohm and red and black is 96 ohm Ombiante temperature is around 40 degree what do you think about this sensor? as I don't have new one to compare Thank you Bon
Tenho uma máquina daykin vrf, são 7 máquinas, 4 k7 e 3 piso teto , já limpei as bombas de treno ,o código PJ fica a.onde , na unidade evaporadora ou na condensadora?
Dear Sir, I am a daikin air conditioning technician, I have followed your channel and learned a lot of useful things. Thank you for sharing that useful information. By the way, can you let me know your email or somehow contact you directly so that you can advise me when I encounter any problems? I really hope to get your help.
Thanks for watching my video.
Please Like, Share and Subscribe .
🙏🙏🙏🙏
You’re a very good technician 👍🏽
Thanks
Thanks for your videos, I can really learn something from these.
Thanks
I have one doubt sir DAIKIN vrv-3 indoor ducted unit set point -16 cut off the valve and set point -30 cut off the valve but set -24 can't cut off the valve more cooling the off what is the issue sir recently replaced EEV
I have one doubt sir DAIKIN vrv-3 indoor ducted unit set point -16 cut off the valve and set point -30 cut off the valve but set -24 can't cut off the valve more cooling the off what is the issue sir recently replaced EEV
Obrigado , ajudou muito f4/02
You always do a great job at your videos, keep up
Thanks bro
Good finding Bon!
Thanks
trimakasih ilmu yah mr bon sukses selalu bos ku thak you goood👍👍👍👍 mantapppp
Terima kasih master.
Tolong share kawan kawan ya🙏🙏
Very useful sir your latest update video
Thanks
Good job thanks for the info 🙏
Thanks bro🙏
Hi, my house unit is also having this issue but it is not happening daily, currently 3 weeks. Why is this so? Do you help to do checks? We used to have this issue in 2021 and Daikin is unable to find out root cause till they changed the entire PCB outdoor. Before this, they changed the valve indoor. What is the impact of not fixing this F4 alarm?
Need collect data and check any parts reading abnormal
previously daikin collected data for 1 full week and cannot find a conclusion till they changed the PCB outdoor. Now this issue comes back again but not on a daily basis. However there is still aircon during the blinking light period. After we turn on and off, the light stopped blinking.
Thx,sir good video
Welcome!
Thank you sir👍👍
We need more info about wirless adapter
How to use it, and how to find it the issues
Thanks
Hi Mr Bon,nk tnya klau sensor c4 rosak adkah boleh buat eev fully open jgak?
Selamat pagi, kena tengok keadaan, check c4 reading dulu.kalau reading kecil mungkin, boleh juga eev rosak punca eev fully open.
請教Bon,如3代大金VRV,室內故障碼F4,會是那裡出錯?
先检查indoor eev 还有thermistor
Ada cara utk check unit indoor mne yg bermasalah thermister seperti masalah dlm video ini ? Atau memang kne check satu persatu bacaan pada remote ?
Kalau Ada DC checker senang, boleh baca semua dalam satu kali, kalau Tak Ada checker pakai wire remote check satu per satu
hello sir., can you i form the normal themperature range.? for the liquid and gas.. thank you
8 - 12
Hi I have problems putting in back my blower wheel into the shaft for my mitsubishi starmex aircon. Previously was stuck and I took it out, maybe I didnt screw the shaft properly. But now it could not be put in properly. Thanks. Is there any way to put it back smoothly?
Check the fan motor shaft alignment
ruclips.net/video/GXLTcSNI3v8/видео.html
@@BonMj Hi thanks for the fast reply, but I tried all angle plus putting lubricant, the blower wheel can only go in half the shaft, I see through the hole of the blower wheel and there is nothing stuck... feel the shaft and visual check also dont seem to have any protruding...
@@AA-su7up try to remove the blower screw and push in or the shaft uneven
Hello Boj hope you well Thanks for the video .
Is it same for the vrv3 ?.
Please how do I know if example a error code appear on the control board , is the fault will be in indoor unit or at outdoor unit (condenser).
Many thanks
T.Matib
What is the error?
@@BonMj Hello Thank you for replying to me ,the error code is F4 on VRV3.
Also in general when I get error code flashing on controller how do I know is a fault on outdoor unit or on indoor unit.
Many thanks
Have good day Bon .
T.Matib
@@toufikmatib9855 F4 normally is indoor EEV problem.
Is fully open
@@BonMj Thank you Bon
Hello Boj I'm having trouble on this vrv3 with code error E2 so my read resistance is between white and red is 12mega ohm and red and black is 96 ohm
Ombiante temperature is around 40 degree what do you think about this sensor? as I don't have new one to compare
Thank you Bon
Thanks a lot bon
Welcome
Thanks you ☺
Welcome
Gracias por la información. Eres el mejor.
thinks sir g thinks
Thanks
What was wrong with office ac? Remote flashing.
Remote flashing and error F4, indoor thermistor faulty .
Permasalahannya di indoor atau outdoor ?
Most is indoor
can the damage be done outdoors too?
hi bon nice Job bro.
J4 error code for video pls. Thnx.
Thanks
Hi boss please one video outdoor airnet address just demo
Normally F4 error code is outdoor side or indoor side issue
Check Fcu eev
What is error f4-05 Daikin vrv
Check indoor EEV
Okay bon there is totally 7 indoor units and this model ac 18 hp &16hp master and slave unit how to check
@@gothandaraj860 try on half of the fcu in cool mode and half in fan mode.
If the fcu in fan mode still cold,mean the eev got problem
Can’t understand
Tenho uma máquina daykin vrf, são 7 máquinas, 4 k7 e 3 piso teto , já limpei as bombas de treno ,o código PJ fica a.onde , na unidade evaporadora ou na condensadora?
Do you replace any pcb.
PJ normally is model setting issue
Eror kode e9 24 diagnosis mr.
Vrv4
Im from indonesia
Saya punya unit vrv3 keluar error F4, saya check Outdoor unit, inverter compressor sejuk kenapa ye?
Selamat pagi,F4 biasa nya salah satu indoor EEV rosak, EEV buka habis.check mana satu indoor yang terlalu sejuk,itu mungkin yang rosak.
Sir video hindi me. Daliye
👍
F4-02师傅
F4 check indoor EEV
Pengalaman.e peno iku
Thanks
Dear Sir,
I am a daikin air conditioning technician, I have followed your channel and learned a lot of useful things. Thank you for sharing that useful information.
By the way, can you let me know your email or somehow contact you directly so that you can advise me when I encounter any problems?
I really hope to get your help.
bonmj81@gmail.com