if my catenary height is 7.2 and contact 5 .8, should I put (7.2/1.676)*90 for caternery centre point? and from that centre point contact wire stagger of -300/+300? please explain this.
RDSO reference ETI/OHE/SK/124 ke schedule ko hi apne badal diya example ke through inside curve me rt plus ki lagti hai aur stagger minus me liya jata hai uska karan hai dono wire inside direction me hote hai aur load inside ki taraf hota hai. Jis wajah se rt opposite lagai jati hai . Rt humesha natural stagger jo wiring ke time ata hai wires me uske against lagai jati hai
if my catenary height is 7.2 and contact 5 .8 and superelevation 90mm, should I put (7.2/1.676)*90 for caternery centre point? and from that centre point contact wire stagger of -300/+300? please explain this.
@@CyraxSweetViper Dear you are taking catenary height and gauge in meter and superelevation in mm please take all values in one parameter second thing with given detail you will found panto and track deflection with respect to lower rail
@@shubhammishra9460 o to sahi hain,but video me contact ki stagger dikhayi gaya hain,but same situation me catenary ka stagger kitna rakhenge,suppose superelevation is 90mm,height of contact 5.8mtr,height of catenary 7.2mtr,then? Please solve it
@@shubhammishra9460 matlab first I will adjust catenary with its height 7.2 in this formula so i will get zero point of catenary and from there I have to adjust -300/+300 for contact stagger to get contact position? if I am wrong could you please bare me 5mins and give an example.if you can plz
ST, BT, RT and steady arm ki length kaise decide krtehain, iske liye maine ek video bnaya hua h, please watch this video, i am giving a link of that video ruclips.net/video/VwrM3OPH1yE/видео.html
Conventional OHE me Contact ka stagger straight track pr +200/-200 mm hota h, aur curved track pr Contact ka stagger +300/-300 mm hota h, High rise OHE me Contact ka stagger straight track pr +150/-150 mm hota h, aur curve track pr Contact ka stagger +250/-250 mm hota h, aur dono hi type ki OHE me Railway me catenary ka stagger zeo rakha jatah, but Metro me isko dead plumb rkhte hain contact k sath
In my new video i have added english subtitles also, please watch it ruclips.net/video/Ix8LrchjsqA/видео.html Please Like and Share the video and Subscribe the channel.
Contact wire ki height 100 mm presag k liye 5.6m hi hoti h, pr jb kisi location pr future me 20 cm track ka uplift projected ho to hum height ko 5.8m lekr hi OHE design krte hain.
@@railwayelectrificationohep7524 sir aap hame ye bataye ki jese over lep me out sid corve me superelaviton 50m ha stiger -200 contact hight 5.60 hi ha to kya karege
Bhot he bdiyaa gopal bhai...shandar...(y)...dheer
Thanks
well explanined in simple way. Then track versine also will be used for stagger adjustment please. and how versine will be used for ohe to calculate
Good work and good explanation
Thanks
Good job. Keep it up
Thanks
Please Give subtitles option
. Very nice explanation
Good effort gopal babu..keep it up👍👍
Thanks
Good work 👍
Excellent
Thanks
Mind-blowing... brother
Thanks brother
@@railwayelectrificationohep7524 hi
Is it compulsory for ohe designe to first locate obligatory mast ???????????
Excellent
Very nice video
Thanks
Very nicely explained
Thanks
Nice explanation 👍👍. Please do make a video on ATD adjustment and cutting
Ok, i will make a complete video on ATD.
@@railwayelectrificationohep7524 TSS SSP SP work video sir
if my catenary height is 7.2 and contact 5 .8,
should I put (7.2/1.676)*90 for caternery centre point?
and from that centre point contact wire stagger of -300/+300?
please explain this.
yes, same formula will be apply for both catenary and contact wire
Railway metro ohe line ke bareme video bana Dijiye
All parts ke bareme
ok, i will make a video on it
Very good
Sir track supreation ke according cantilever adjustment kaise karte
Nice bro
Thanks
अच्छा बताया आपणे
Thanks
Wow sir
Biomatlic strip fideee mastai kanha pr use hota hai sir ji
Curve inside ho ya outside stagger humesha positive hi ata hai dono case me pento positive me hi tilt hota hai example practically dijiye
Aapka panto kharab hai
good work
Thanks
RDSO reference ETI/OHE/SK/124 ke schedule ko hi apne badal diya example ke through inside curve me rt plus ki lagti hai aur stagger minus me liya jata hai uska karan hai dono wire inside direction me hote hai aur load inside ki taraf hota hai. Jis wajah se rt opposite lagai jati hai . Rt humesha natural stagger jo wiring ke time ata hai wires me uske against lagai jati hai
if my catenary height is 7.2 and contact 5 .8 and superelevation 90mm,
should I put (7.2/1.676)*90 for caternery centre point?
and from that centre point contact wire stagger of -300/+300?
please explain this.
@@CyraxSweetViper Dear you are taking catenary height and gauge in meter and superelevation in mm please take all values in one parameter second thing with given detail you will found panto and track deflection with respect to lower rail
@@shubhammishra9460 o to sahi hain,but video me contact ki stagger dikhayi gaya hain,but same situation me catenary ka stagger kitna rakhenge,suppose superelevation is 90mm,height of contact 5.8mtr,height of catenary 7.2mtr,then? Please solve it
@@CyraxSweetViper dono adjust karne padte hai taki contact clip tilt na ho jaye y rt bend na ho jaye
@@shubhammishra9460 matlab first I will adjust catenary with its height 7.2 in this formula so i will get zero point of catenary and from there I have to adjust -300/+300 for contact stagger to get contact position? if I am wrong could you please bare me 5mins and give an example.if you can plz
Great work sir 👍
thanks
Isolator & it's parts RI no.
Sir aap ohe design ka class dete hai.pls help me...
nhi main koi class nhi deta hoon, but you can ask me personally on my mail, whatever you want to ask regarding OHE & PSI
Good
Thanks
large span wire aur RC wire kya hota hai ?
Best
Feeder mast Mai biomatlic strip kanha pr use hota hai sir ji
Or ye biometalic strip hota Kya hai
ok i will make a video on this
Thanks सर g
Panto mein zero Reading kis k refrence mein lete h
Panto me zero reading OHE k reference me lete hain, hamare sare references OHE k according hi rhte hain
How to adjust catenary stagger of zero(0) in inside/outside curver
TT, BT, RT, Steady arm ko kaise choose kre ge please Reapply
ST, BT, RT and steady arm ki length kaise decide krtehain, iske liye maine ek video bnaya hua h, please watch this video, i am giving a link of that video
ruclips.net/video/VwrM3OPH1yE/видео.html
high rise and conventional ohe me kya difference hota hai plaesa bataye
Basic Difference is of height of catenary and contact wire.High rise OHE is for those route where Double container locomotive runs.
ok
Sp ssp tss par video banaiye sir ji
ok, i will make a video on this
Versine kese measure kare video dene se achha hoga
ok i will make a video on that
Sir please tell Maximum stager of ohe in curve kitna?
Maximum stagger Conventional OHE me 300 mm rhta h aur high rise OHE me maximum stagger 250 mm rhta h
O bhai ye to pata hi nhi tha..
(•‿•)
Spine dropper formula bataye sir
Sir OHE foundation kaun kaha use krna chahiye
ok i will make a video on this
Cross over and turn out par contact wire ki hight kitni hoti h
Turnout/crossover pr video jaldi hi aane wala h
Type of mast video b upload kare sir g
Ok sure, i will make a complete video on Type of mast
SI and T/OUT Adjustment one video plz
Take 1 aur tak2 in iver lap pr video daly
ok, i will make a video
Catanary kya stagger kya hoga curve par aur kaise determine karenge
Curve pr catenary ka stagger jitna contact ka stagger hota h uske same hi rakhte hain
Sir kaise pta kiye ki stg kaise pta kiye
mail me, i will send you pdf
Thik you
Boom combination related video
ok i will make a video on it
🤩💖🥳👸
How to put a stagger of catenary wire on curve line
Appy the same formula, just put height of catenary wire instead of contact wire
eto contact ka stagger hogaya,caternery ka stagger kitna rakhenge?
same formula apply for catenary also.
Formula same hoga but height change hoga?
Can you please share the pdf file of this video & also any other important calculation of ohe design
mail me, i will send you
Sir cantilever ka formula kaise solve kare
Ek imp ka hisabse Thora example de
Stagger kese rakte hai batawo 3 over lap
i will make a separate video at this topic.
🙏🙏
Contact wire height 7.57 kyu liye??
double decker/double container train ka route hota h wahan pr rakhte hain
Contact height ko lete hai n
jis wire ka stagger rakhna h usko lete hain
Sir voice slow aa rha haii
From my side everything is OK, if still same problem persist please use headphones.
Sir define cont and cat
Cont & cat stg on super elevation
Conventional OHE me Contact ka stagger straight track pr +200/-200 mm hota h, aur curved track pr Contact ka stagger +300/-300 mm hota h, High rise OHE me Contact ka stagger straight track pr +150/-150 mm hota h, aur curve track pr Contact ka stagger +250/-250 mm hota h, aur dono hi type ki OHE me Railway me catenary ka stagger zeo rakha jatah, but Metro me isko dead plumb rkhte hain contact k sath
Pls add English subtitles.. In your video
In my new video i have added english subtitles also, please watch it
ruclips.net/video/Ix8LrchjsqA/видео.html
Please Like and Share the video and Subscribe the channel.
Background music hata dijiye plz..
Kaafi disturbing hai..
ok, thanks for your suggession
Contact height to 5.8 m hota h
Contact wire ki height 100 mm presag k liye 5.6m hi hoti h, pr jb kisi location pr future me 20 cm track ka uplift projected ho to hum height ko 5.8m lekr hi OHE design krte hain.
New videos upload sir
I'm new join in TRD department.......
@@kishorenaik7736 New video is coming soon
@@kishorenaik7736 zone and division
@@madanlal-rb5jl ECoR SBP
Sir practical chaiye
ok, soon i will provide it
Sir plz apke num mil sakte he kya ..
plz plz z....I am new recruited JE
You can mail me at
sharma.gopal568@gmail.com
@@railwayelectrificationohep7524 sir aap hame ye bataye ki jese over lep me out sid corve me superelaviton 50m ha stiger -200 contact hight 5.60 hi ha to kya karege
Plz your whtsapp no send
Galt bta rahe hai aap sir
Sir aap ka number chahiye
Good job
Thanks