Siglent SD3055 FW Update...and some Quirks

Поделиться
HTML-код
  • Опубликовано: 8 сен 2024
  • Please support my content creation by using my Amazon Store:
    astore.amazon.c...
    Or anything on Amazon:
    www.amazon.com/...
    ----------------------------- Click "Show more" ------------------------------------------
    In this video I chat about the Siglent SD3055 firmware updates:
    sdm305(V100R001B01D01P15R1) (ver 1.01.01.15R1) and sdm305(V100R001B01D01P15R2) (ver 1.01.01.15R1).
    These improve amongst other things:
    * Increase the trigger / UI update speed.
    * Add the diode threshold setting function.
    * Fix a bug in temperature measurement.
    Quirks:
    * The saving of the settings for next power on can take up to a minute. If the meter is powered off before then, the settings are not saved.
    * The Filter feature used in DC measurements switches a large capacitor across the input which can unsettle the reading and change the 10 Mega Ohm input impedance while it charges.
    Siglent have committed to maintaining a change log for the firmware and updating their manual to explain the way some of their "features" work.
    ------------------------------------------------------------------------------------------------------
    My website and forum:- www.mjlorton.com
    Donations and contributions:- www.mjlorton.com
    My techie channel MJLorton - Solar Power and Electronic Measurement Equipment - / mjlorton
    My Techie Amazon Store: astore.amazon.c...
    My other channel VBlogMag - For almost any topic under the sun! - / vblogmag
    My VBlogMag Amazon Store: astore.amazon.c...
    ------------------------------------------------------------------------------------------------------
    ===================================================
    Video sponsor, Pass Ltd - their websites:
    At checkout use the discount / promotion code "mjlorton" for 5% off.
    www.tester.co.u... - Test Equipment and Test-meter suppliers and
    www.calibrate.c... - Calibration and service of test equipment
    ===================================================
    $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
    Bitcoin (BTC) Donations: 1K7PeF55e7ssE7W3WVCoa7c4j2PHzy6ASv
    $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
    **********************************************************************************
    Music clip from RUclips Music Library - Phase Three by Huma-Huma
    **********************************************************************************

Комментарии • 30

  • @g1fsh
    @g1fsh 8 лет назад +1

    At least they seem to be listening Martin and trying to move forward. I love the big display on this meter and with the bugs ironed out and for this price I see a very nice meter in the future. It shows how much well deserved respect these people have for your opinion.

    • @mjlorton
      @mjlorton  8 лет назад

      +Gary g1fsh Thanks for the post Gary.

  • @jeffsansoterra7743
    @jeffsansoterra7743 8 лет назад

    Thanks Martin. It is good to see all the deep characterization of this meter and how Siglent has been responding with updates.

  • @sdgelectronics
    @sdgelectronics 8 лет назад +2

    Thanks for the video Martin!

  • @billybbob18
    @billybbob18 Год назад +1

    With what you're describing with the slow state update . I think this may use EEPROM to store the settings. EEPROM has a limited write cycle at around a million write cycles depending on temperature conditions. Being conservative with that sort of memory was wise. And who changes settings then immediately turn it off anyway. They should tie the power button to the update storage function. obvious fix

  • @DeeegerD
    @DeeegerD 8 лет назад +1

    The AC filter taking a few moments to settle makes perfect sense as it takes time to charge the capacitor... Don't see a problem. They could have used a smaller value cap but I'm sure it was selected for maximum voltages and current. Short of having an array of capacitors selected by range... Just get some patience ;)

    • @balbes1165
      @balbes1165 6 лет назад

      They should have implemented a digital filter...

  • @ElmerFuddGun
    @ElmerFuddGun 8 лет назад +5

    What's the point of having a "soft" power button then? That's when they should be saving the settings. And even if you write to flash memory every single time it shouldn't be a problem if done right. You don't write to the exact same bytes but cycle through the entire flash or EEPROM (wear levelling). Heck, even if you do it "wrong" these chips have 100,000+ to 1,000,000+ write cycle endurances. I don't see how they would need much space to save every option on this meter.
    25+ years ago people were saving machine state information when it detected a hard power off and had to save the information before the charge on the PS caps died. Limited time and memory that didn't have the write cycle life that today's chips have yet it worked fine. This has a soft power button giving them all the time they want to write data before turning off. I'm confused why they are having a problem.
    What are they using the soft power button for then? They're not using it during shutdown and they are not using it to allow a quick start up (the screen should come on instantly) so what is the point? Just to have a high standby current and a pulsing LED?!

  • @rotlerin
    @rotlerin 8 лет назад

    As a resident of Merseyside UK, I just love that t-shirt Martin. By the way, the video's cool too!

  • @PapasDino
    @PapasDino 8 лет назад

    Rigol has been pretty good about their change logs and in some cases has been responsive to user feedback albeit taking some time to implement. Thanks for the update, nice to see that at least they're trying! 73 - Dino KL0S

  • @SteelBlueVision
    @SteelBlueVision 8 лет назад +1

    Oh, I see they have "fixed many other problems," according to their release notes. How informative!

  • @leppie
    @leppie 8 лет назад +1

    They should just save the settings when it soft power-off. But, does it have a way to do reset to defaults if something messed up?

  • @tonycstech
    @tonycstech 2 года назад

    In comparison to ANY handheld, this multimeter shows EXACTLY HALF the resistance value measured in circuit.
    Why is that ?

  • @Coolkeys2009
    @Coolkeys2009 8 лет назад +1

    Why didn't they write the firmware to save the settings just before it powers down? At least they're not wearing out the flash by saving every control change to it.

    • @mjlorton
      @mjlorton  8 лет назад

      +Coolkeys2009 Valid point. I think they will be reading these comments and hopefully they can provide an answer.

  • @Eric4711
    @Eric4711 8 лет назад +3

    Where can I get the new firmware? I don't see it on the Siglent site.

    • @mjlorton
      @mjlorton  8 лет назад

      +Eric Hospel Hi Eric, I've asked Siglent to respond to your question. I know they gave it to me ahead of time so I think it should be up on their site soon..but I'll let them confirm.

    • @Eric4711
      @Eric4711 8 лет назад

      +mjlorton Thanks Martin. I did get a version of the 15R2 firmware and the problem is fixed!

    • @mjlorton
      @mjlorton  8 лет назад

      +Eric Hospel Brilliant, thanks for posting the feedback.

  • @krish2nasa
    @krish2nasa 7 лет назад

    Hi Martin, Did you try (Filter On and Off VDC test) with 10GΩ input impedance setting?

  • @mread42
    @mread42 8 лет назад

    Martin, thanks for this, did you get a chance to asses the temperature measurements ? At the moment it is very inaccurate, ( reads about 4 C high ), using my sdm3055 with a k series thermocouple and 15R1 firmware, and I want to use it for some data logging.

    • @mjlorton
      @mjlorton  8 лет назад

      +Martin Read Hi Martin, I did not take the time to properly assess the temperature issue but that's the key issue 15R2 is supposed to correct. If I have the time I'll role back my update and see if I have the same issue.

  • @pratwurschtgulasch6662
    @pratwurschtgulasch6662 3 года назад

    China #1

  • @SatyajitRoy2048
    @SatyajitRoy2048 8 лет назад

    If it has got a large filter cap, then why is it overshooting when you disconnect and connect the input ? Where is it getting the extra voltage from ? Would you please consider tearing down the multi meter and show where exactly things happening which is causing this issue?

    • @CZDrMike
      @CZDrMike 8 лет назад

      +Satyajit Roy I think that perhaps this overshoot has to do something with inductance of wires (just my theory)

    • @SatyajitRoy2048
      @SatyajitRoy2048 8 лет назад

      +CZDrMike It could be, but as there is a series resistor it should not reach the highest value and then comes down to the actual. If you see the point when the probes are connected, then it starts by showing some milli volts (due to the incomplete integration period or something), but all of a sudden it goes 10.2436V and then settles down to the value. If it is due to inductance then its a bit difficult to charge the internal cap at that fast rate. I am assuming there is input series resistor which is certain for input protection mechanism. So the inductance factor might not work as per my views. Another point is, when the filter was disabled, then the overshoot didn't occur and the same inductance factor should have worked if it was meant to be the reason. Its interesting fact and I just cant find why its happening. However, if Martin is confident enough to let us see how the inside looks and the input sections are, then it will certainly reveal some of the interesting facts that we might be looking for :)

    • @mjlorton
      @mjlorton  8 лет назад

      +Satyajit Roy That's certainly a consideration if I can grab the time. The Signal Path does a look inside in his review so you may spot something there in his video.

  • @Sainology
    @Sainology 8 лет назад

    SD "M" not SD :P

  • @kaybhee6
    @kaybhee6 3 года назад

    can u measire less than 1 milli ohm

  • @kyoadam1593
    @kyoadam1593 3 года назад

    You should hack it