Yes that's true because with an aftermarket firmware you can disable that , but it comes at a price where you need to Pay 3% of Dev fee to the firmware developer that's why i didn't use a third party firmware on the video since most people will keep their miner on a stock firmware , but thanks for the input
@@Crypto_mining_labIf there is not yet a Braiins OS for S19 Hydro I use it because of the automatic reboot in case of loss of connection or undervoltage in the network. It works great for that.
if you are referring to the power cord for the miner , it is the standard cable form bitmain for S19 Hydro , if you referring to the cable coming from the main breaker to the the miners breaker , then it will depend on how many miners you running on a single cables
This was done in China for your information all mining pools are banned in China , so the pools we used is a private pool , you can see the pool address used , that’s why
Hello Sir thank you for your videos, very valuable information. What is the temperature of the water that gets out of the miner? If I were to heat a storage of water with it, how hot could I get the water?
the temps of the coolant out of the miners is usually between 65 to 80 C depending on how efficient is your cooling , and you can definitely reuse the heat for other purposes
yes they need some kind of system to dissipate the heat , so they needs a hydro cooling cabinet if you have many miners , or a small radiator if you have one or two units
Not relevant to many people. It is normal for it to run for 10 minutes at 15 degrees Celsius outside temperature as in your video. You must specify that everything depends on the outside temperature. I have exactly this configuration, but a huge cooler with a dissipation power of 100 Kw, and a pump of 100 L/m and when the outside temperature reaches 32 degrees Celsius it stops working. Asic reaches 90 degrees.
You need to be more specific on your setup as well , you meyiihdd a 100kw dry cooler , a 100L/ M pump but you don’t mention anything number about the number of miners you have , because when you say you have same setup people will assume that you are running two miners with 100kw dry cooler and 100L/m flow pump which is completely incorrect
@@Crypto_mining_lab As I specified, in the first message, the same configuration, i.e. fixed the same number of asic-s, and the same model. Now it's clear...?
its not a static value , it will change based on many factors , how much heat the miner is generating , and you ambient temp , but as longas you keep your intlet fluid temp between 28 C to 40 C , and inlet inside the miner below 80 C the miner will run fine
When you say the same you mean similar , the cooling capacity on the radiator I was using is 15kw , and water pump flow is 25. L / min , so I’m sure you using something similar but not the same , that’s why you having overheating issue
Hello, I am impressed with the excellent content you have provided! 👍🏻 Could you tell me if it is complicated to get a license for mining in Dubai? Thx
Get a 10% Discount by using this code : 15KW www.asicshield.com/product-pa... www.cryptomininglab.net/produ... a perfect solution for small scale Hydro mining a dry cooler with a capacity of 15Kw that can handle 2 units of any of hydro miners available in the market
i live in a freezing country. i send 21 centigrade into my S21 335T but don't start mine it says, "ERROR_TEMP_TOO_HIGH: over max temp" Does anyone know why? 2024-04-20 12:12:08 water temp 21 ~ 22, stop. 2024-04-20 12:12:08 set UART baud to 115200 2024-04-20 12:12:16 Chain[0]: find 216 asic, times 0 2024-04-20 12:12:23 Chain[1]: find 216 asic, times 0 2024-04-20 12:12:31 Chain[2]: find 216 asic, times 0 2024-04-20 12:13:51 too hot water temperature pic temp 56 (min 56) 2024-04-20 12:13:51 ERROR_TEMP_TOO_HIGH: over max temp 2024-04-20 12:13:51 stop_mining: over max temp 2024-04-20 12:13:51 uninit_temp_info 2024-04-20 12:13:51 do not read temp anymore... 2024-04-20 12:13:51 uninit_asic_temp_vol_info 2024-04-20 12:13:51 do not read asic_temp_vol anymore... 2024-04-20 12:13:51 cancel thread 2024-04-20 12:13:51 ***power off hashboard***
What power plug u use ???
Can you make more videos about the s21 hydro, I'm considering getting one and also the 15kw radiator.
The S19 hydro and S21 hydro are the same in terms of cooling requirement , so what works for the S19 will definitely work for the S21
Have you bought S21 HYD?
When using Vnish firmware, you don't need to wait for 20*C hot water. They have a start at 10*C.
Yes that's true because with an aftermarket firmware you can disable that , but it comes at a price where you need to Pay 3% of Dev fee to the firmware developer that's why i didn't use a third party firmware on the video since most people will keep their miner on a stock firmware , but thanks for the input
@@Crypto_mining_labIf there is not yet a Braiins OS for S19 Hydro I use it because of the automatic reboot in case of loss of connection or undervoltage in the network. It works great for that.
I use a heatgun on the radiator and miner if it´s to cold.
Ready in 10 min at 10°C.
thats a good solutions too , thanks for sharing
Is there English instructions and GUI?
yes there are comes with the cooler
Sir which s19 hydro series have upper inlet and which s19 series have lower inlet ?
Plz tell
What's cable size from fuse box to miner's breaker is it 2.5mm or more
if you are referring to the power cord for the miner , it is the standard cable form bitmain for S19 Hydro , if you referring to the cable coming from the main breaker to the the miners breaker , then it will depend on how many miners you running on a single cables
Why so many stale shares. and so few accepted? Would have expected to see higher number of accepted than stale.
This was done in China for your information all mining pools are banned in China , so the pools we used is a private pool , you can see the pool address used , that’s why
@@Crypto_mining_lab I did wonder about the IP in the stratum. Thanks for the info hash on!
Do you think you could add a 3rd miner?
Only if you are in a cold location , otherwise it’s gonna be hard for the cooler to keep up with miners
20 degrees is a real "troublemaker" in case you often start/stop mining, is there any patch out there to fix this ???? 15 degrees
try some of the after market firmwares such as Vinish , you can lower that mini to 10 C i think
Hello Sir thank you for your videos, very valuable information. What is the temperature of the water that gets out of the miner? If I were to heat a storage of water with it, how hot could I get the water?
the temps of the coolant out of the miners is usually between 65 to 80 C depending on how efficient is your cooling , and you can definitely reuse the heat for other purposes
how many triphasic I need ? One for the miner and one for the drycooler? Thank you.
the dry cooler runs on single phase 200V-240V , it doesn't require three phase
@@Crypto_mining_lab thanks man I appreciate it.
I have antminer s19 pro hydro 184 th is it normal for inlet temp is 66 and outlet is 55
its not , you must have reversed the inlet and outlet piping , the inlet should be on the hasboards and outlet at the PSU
Can you also tell me where is the inlet and outlet in the radiator maybe I reversed
Hydro miners don't work without a radiator?
yes they need some kind of system to dissipate the heat , so they needs a hydro cooling cabinet if you have many miners , or a small radiator if you have one or two units
How much for the dry cooler
Check the link www.cryptomininglab.net/product-page/s19-hydro-m33-m53-dry-cooler-with-15kw-capacity
How many can be connected to the radiator? In a cold place is more than 3 possible?
maximum of two miners hydro
Hello friend, is the Y coupling 1/2" or 3/8"?
Is the hose that enters the miner 10mm or 12mm?
Isn't it better to use g12 cooling liquid?
thank you
Not relevant to many people. It is normal for it to run for 10 minutes at 15 degrees Celsius outside temperature as in your video. You must specify that everything depends on the outside temperature. I have exactly this configuration, but a huge cooler with a dissipation power of 100 Kw, and a pump of 100 L/m and when the outside temperature reaches 32 degrees Celsius it stops working. Asic reaches 90 degrees.
You need to be more specific on your setup as well , you meyiihdd a 100kw dry cooler , a 100L/ M pump but you don’t mention anything number about the number of miners you have , because when you say you have same setup people will assume that you are running two miners with 100kw dry cooler and 100L/m flow pump which is completely incorrect
@@Crypto_mining_lab As I specified, in the first message, the same configuration, i.e. fixed the same number of asic-s, and the same model. Now it's clear...?
May i use (it is better like watter) coolant which is used in cars?
definitely you can , it would be better specially for cold climate
Hi!!
What is the thermal equilibrium point? after hours of operation
its not a static value , it will change based on many factors , how much heat the miner is generating , and you ambient temp , but as longas you keep your intlet fluid temp between 28 C to 40 C , and inlet inside the miner below 80 C the miner will run fine
@Crypto_mining_lab it's interesting I have lianli radiator and when the water is above 35c the miner show red light .
can I use this one dry cooler for my two s21 hyd?
depends on your location , if you live in an area where ambient temp dont exceed 35C yes you can run two miners with this dry cooler
And I have a extra question. The s21 hyd use one three-phase cable only? Or the ASIC use 2?(for connecting to the wall)
@@trofixgo5332 all hydro miners use only one cable which is a three phase cable
Can it run on solar energy?
yes absolutely
I am using same as your antminer and radiator but it barely can handle 1 miner
When you say the same you mean similar , the cooling capacity on the radiator I was using is 15kw , and water pump flow is 25. L / min , so I’m sure you using something similar but not the same , that’s why you having overheating issue
Are the hydro miners 3 ph or single phase.
all hydro miners run on 3 phase 380/415V 50/60Hz
I dont know anyone with 3ph at there house. Is there a way to convert it over to single phase.
@@Crypto_mining_labI think that hydro miners work on 2 phases, not three, the third cable is like a neutral wire, not a phase
Hi,
do you know how much energy this cooler requires?
it doesn't require much energy compared to the miners them self , between the pump the fans you are looking at 300W consumption
Hello, I am impressed with the excellent content you have provided! 👍🏻 Could you tell me if it is complicated to get a license for mining in Dubai?
Thx
Email me through our website regarding mining license in the uae
Get a 10% Discount by using this code : 15KW
www.asicshield.com/product-pa...
www.cryptomininglab.net/produ...
a perfect solution for small scale Hydro mining
a dry cooler with a capacity of 15Kw that can handle 2 units of any of hydro miners available in the market
سلام
من ساکن ایران شهر اصفهان هستم
لطفا میتوانید مشخصات فنی رادیاتور و فن های خنک کننده و پمپ اب را برای من ارسال کنید
با تشکر
you can purchase the product through us
the biggest problem is finding 416 volts to run that miner.
True not everyone has access to three phase , but actually the miner will run on any three phase with 380V to 415 V it doesn’t have to be 415 V
@@Crypto_mining_labminer is working only on two phases not three if i have good infos.
من زبان انگلیسی بلد نیستم
i live in a freezing country. i send 21 centigrade into my S21 335T but don't start mine it says, "ERROR_TEMP_TOO_HIGH: over max temp" Does anyone know why?
2024-04-20 12:12:08 water temp 21 ~ 22, stop.
2024-04-20 12:12:08 set UART baud to 115200
2024-04-20 12:12:16 Chain[0]: find 216 asic, times 0
2024-04-20 12:12:23 Chain[1]: find 216 asic, times 0
2024-04-20 12:12:31 Chain[2]: find 216 asic, times 0
2024-04-20 12:13:51 too hot water temperature pic temp 56 (min 56)
2024-04-20 12:13:51 ERROR_TEMP_TOO_HIGH: over max temp
2024-04-20 12:13:51 stop_mining: over max temp
2024-04-20 12:13:51 uninit_temp_info
2024-04-20 12:13:51 do not read temp anymore...
2024-04-20 12:13:51 uninit_asic_temp_vol_info
2024-04-20 12:13:51 do not read asic_temp_vol anymore...
2024-04-20 12:13:51 cancel thread
2024-04-20 12:13:51 ***power off hashboard***
it will help a lot if you can send a full load after starting the miner
you can email it to : info@crypomininglab.net
@@Crypto_mining_lab your email not working
does it make lot sounds like the others ant miner🥲
no , no where near the noise from a regular antminer , you can run these at home no issue