  • @Moodboard39
    @Moodboard39 10 часов назад

    What power plug u use ???

  • @YoanGonzalez-yr2rf
    @YoanGonzalez-yr2rf 8 месяцев назад +4

    Can you make more videos about the s21 hydro, I'm considering getting one and also the 15kw radiator.

    • @Crypto_mining_lab
      @Crypto_mining_lab  8 месяцев назад +1

      The S19 hydro and S21 hydro are the same in terms of cooling requirement , so what works for the S19 will definitely work for the S21

    • @UnistarAda
      @UnistarAda 7 месяцев назад

      Have you bought S21 HYD?

  • @beny68eos
    @beny68eos 10 месяцев назад +2

    When using Vnish firmware, you don't need to wait for 20*C hot water. They have a start at 10*C.

    • @Crypto_mining_lab
      @Crypto_mining_lab  10 месяцев назад +1

      Yes that's true because with an aftermarket firmware you can disable that , but it comes at a price where you need to Pay 3% of Dev fee to the firmware developer that's why i didn't use a third party firmware on the video since most people will keep their miner on a stock firmware , but thanks for the input

    • @beny68eos
      @beny68eos 10 месяцев назад

      @@Crypto_mining_labIf there is not yet a Braiins OS for S19 Hydro I use it because of the automatic reboot in case of loss of connection or undervoltage in the network. It works great for that.

  • @Grimmjar
    @Grimmjar 10 месяцев назад +1

    I use a heatgun on the radiator and miner if it´s to cold.
    Ready in 10 min at 10°C.

    • @Crypto_mining_lab
      @Crypto_mining_lab  10 месяцев назад

      thats a good solutions too , thanks for sharing

  • @Shard37
    @Shard37 3 дня назад +1

    Is there English instructions and GUI?

  • @AshishKumar-uu3lw
    @AshishKumar-uu3lw 3 месяца назад

    Sir which s19 hydro series have upper inlet and which s19 series have lower inlet ?
    Plz tell

  • @samooburst8548
    @samooburst8548 8 месяцев назад +1

    What's cable size from fuse box to miner's breaker is it 2.5mm or more

    • @Crypto_mining_lab
      @Crypto_mining_lab  8 месяцев назад

      if you are referring to the power cord for the miner , it is the standard cable form bitmain for S19 Hydro , if you referring to the cable coming from the main breaker to the the miners breaker , then it will depend on how many miners you running on a single cables

  • @DaRaccoonCrypto
    @DaRaccoonCrypto 9 месяцев назад +1

    Why so many stale shares. and so few accepted? Would have expected to see higher number of accepted than stale.

    • @Crypto_mining_lab
      @Crypto_mining_lab  9 месяцев назад +1

      This was done in China for your information all mining pools are banned in China , so the pools we used is a private pool , you can see the pool address used , that’s why

    • @DaRaccoonCrypto
      @DaRaccoonCrypto 9 месяцев назад

      @@Crypto_mining_lab I did wonder about the IP in the stratum. Thanks for the info hash on!

  • @darrenjohnson9019
    @darrenjohnson9019 9 месяцев назад +1

    Do you think you could add a 3rd miner?

    • @Crypto_mining_lab
      @Crypto_mining_lab  9 месяцев назад

      Only if you are in a cold location , otherwise it’s gonna be hard for the cooler to keep up with miners

  • @stevengabor3334
    @stevengabor3334 6 месяцев назад +1

    20 degrees is a real "troublemaker" in case you often start/stop mining, is there any patch out there to fix this ???? 15 degrees

    • @Crypto_mining_lab
      @Crypto_mining_lab  6 месяцев назад

      try some of the after market firmwares such as Vinish , you can lower that mini to 10 C i think

  • @portzir
    @portzir 9 месяцев назад +1

    Hello Sir thank you for your videos, very valuable information. What is the temperature of the water that gets out of the miner? If I were to heat a storage of water with it, how hot could I get the water?

    • @Crypto_mining_lab
      @Crypto_mining_lab  9 месяцев назад +1

      the temps of the coolant out of the miners is usually between 65 to 80 C depending on how efficient is your cooling , and you can definitely reuse the heat for other purposes

  • @trofixgo5332
    @trofixgo5332 3 месяца назад

    how many triphasic I need ? One for the miner and one for the drycooler? Thank you.

    • @Crypto_mining_lab
      @Crypto_mining_lab  3 месяца назад

      the dry cooler runs on single phase 200V-240V , it doesn't require three phase

    • @trofixgo5332
      @trofixgo5332 3 месяца назад

      @@Crypto_mining_lab thanks man I appreciate it.

  • @SBSS_-
    @SBSS_- 7 месяцев назад +1

    I have antminer s19 pro hydro 184 th is it normal for inlet temp is 66 and outlet is 55

    • @Crypto_mining_lab
      @Crypto_mining_lab  7 месяцев назад

      its not , you must have reversed the inlet and outlet piping , the inlet should be on the hasboards and outlet at the PSU

    • @SBSS_-
      @SBSS_- 7 месяцев назад

      Can you also tell me where is the inlet and outlet in the radiator maybe I reversed

  • @7777Tiago
    @7777Tiago 7 месяцев назад +1

    Hydro miners don't work without a radiator?

    • @Crypto_mining_lab
      @Crypto_mining_lab  7 месяцев назад +1

      yes they need some kind of system to dissipate the heat , so they needs a hydro cooling cabinet if you have many miners , or a small radiator if you have one or two units

  • @التقنيةوالمعلومات-م3خ
    @التقنيةوالمعلومات-م3خ 4 месяца назад +1

    How much for the dry cooler

    • @Crypto_mining_lab
      @Crypto_mining_lab  4 месяца назад

      Check the link www.cryptomininglab.net/product-page/s19-hydro-m33-m53-dry-cooler-with-15kw-capacity

  • @MisterNewton
    @MisterNewton Месяц назад

    How many can be connected to the radiator? In a cold place is more than 3 possible?

  • @JorgeGarcia-ph4le
    @JorgeGarcia-ph4le 8 месяцев назад

    Hello friend, is the Y coupling 1/2" or 3/8"?
    Is the hose that enters the miner 10mm or 12mm?
    Isn't it better to use g12 cooling liquid?
    thank you

  • @ionescumihai3099
    @ionescumihai3099 9 месяцев назад

    Not relevant to many people. It is normal for it to run for 10 minutes at 15 degrees Celsius outside temperature as in your video. You must specify that everything depends on the outside temperature. I have exactly this configuration, but a huge cooler with a dissipation power of 100 Kw, and a pump of 100 L/m and when the outside temperature reaches 32 degrees Celsius it stops working. Asic reaches 90 degrees.

    • @Crypto_mining_lab
      @Crypto_mining_lab  9 месяцев назад +1

      You need to be more specific on your setup as well , you meyiihdd a 100kw dry cooler , a 100L/ M pump but you don’t mention anything number about the number of miners you have , because when you say you have same setup people will assume that you are running two miners with 100kw dry cooler and 100L/m flow pump which is completely incorrect

    • @ionescumihai3099
      @ionescumihai3099 9 месяцев назад

      @@Crypto_mining_lab As I specified, in the first message, the same configuration, i.e. fixed the same number of asic-s, and the same model. Now it's clear...?

  • @vladimirsamselyi155
    @vladimirsamselyi155 5 месяцев назад

    May i use (it is better like watter) coolant which is used in cars?

    • @Crypto_mining_lab
      @Crypto_mining_lab  5 месяцев назад

      definitely you can , it would be better specially for cold climate

  • @rodrigokapo33
    @rodrigokapo33 10 месяцев назад

    Hi!!
    What is the thermal equilibrium point? after hours of operation

    • @Crypto_mining_lab
      @Crypto_mining_lab  10 месяцев назад +1

      its not a static value , it will change based on many factors , how much heat the miner is generating , and you ambient temp , but as longas you keep your intlet fluid temp between 28 C to 40 C , and inlet inside the miner below 80 C the miner will run fine

    • @arielik00
      @arielik00 8 месяцев назад

      ​@Crypto_mining_lab it's interesting I have lianli radiator and when the water is above 35c the miner show red light .

  • @trofixgo5332
    @trofixgo5332 3 месяца назад

    can I use this one dry cooler for my two s21 hyd?

    • @Crypto_mining_lab
      @Crypto_mining_lab  3 месяца назад +1

      depends on your location , if you live in an area where ambient temp dont exceed 35C yes you can run two miners with this dry cooler

    • @trofixgo5332
      @trofixgo5332 3 месяца назад +1

      And I have a extra question. The s21 hyd use one three-phase cable only? Or the ASIC use 2?(for connecting to the wall)

    • @Crypto_mining_lab
      @Crypto_mining_lab  3 месяца назад

      @@trofixgo5332 all hydro miners use only one cable which is a three phase cable

  • @Baby-CEO
    @Baby-CEO 6 месяцев назад +1

    Can it run on solar energy?

  • @SBSS_-
    @SBSS_- 8 месяцев назад +1

    I am using same as your antminer and radiator but it barely can handle 1 miner

    • @Crypto_mining_lab
      @Crypto_mining_lab  8 месяцев назад

      When you say the same you mean similar , the cooling capacity on the radiator I was using is 15kw , and water pump flow is 25. L / min , so I’m sure you using something similar but not the same , that’s why you having overheating issue

  • @michaelzimmerman5151
    @michaelzimmerman5151 9 месяцев назад +1

    Are the hydro miners 3 ph or single phase.

    • @Crypto_mining_lab
      @Crypto_mining_lab  9 месяцев назад

      all hydro miners run on 3 phase 380/415V 50/60Hz

    • @michaelzimmerman5151
      @michaelzimmerman5151 9 месяцев назад +2

      I dont know anyone with 3ph at there house. Is there a way to convert it over to single phase.

    • @vladimirsamselyi155
      @vladimirsamselyi155 5 месяцев назад

      ​@@Crypto_mining_labI think that hydro miners work on 2 phases, not three, the third cable is like a neutral wire, not a phase

  • @kappaxy1085
    @kappaxy1085 7 месяцев назад

    Hi,
    do you know how much energy this cooler requires?

    • @Crypto_mining_lab
      @Crypto_mining_lab  7 месяцев назад

      it doesn't require much energy compared to the miners them self , between the pump the fans you are looking at 300W consumption

  • @Mr.cold.as.ice.
    @Mr.cold.as.ice. 10 месяцев назад +1

    Hello, I am impressed with the excellent content you have provided! 👍🏻 Could you tell me if it is complicated to get a license for mining in Dubai?
    Thx

    • @Crypto_mining_lab
      @Crypto_mining_lab  10 месяцев назад +1

      Email me through our website regarding mining license in the uae

  • @Crypto_mining_lab
    @Crypto_mining_lab  10 месяцев назад

    Get a 10% Discount by using this code : 15KW
    www.asicshield.com/product-pa...
    www.cryptomininglab.net/produ...
    a perfect solution for small scale Hydro mining
    a dry cooler with a capacity of 15Kw that can handle 2 units of any of hydro miners available in the market

  • @rezaarab6788
    @rezaarab6788 4 месяца назад

    سلام
    من ساکن ایران شهر اصفهان هستم
    لطفا میتوانید مشخصات فنی رادیاتور و فن های خنک کننده و پمپ اب را برای من ارسال کنید
    با تشکر

  • @crisis3714
    @crisis3714 10 месяцев назад +2

    the biggest problem is finding 416 volts to run that miner.

    • @Crypto_mining_lab
      @Crypto_mining_lab  10 месяцев назад +1

      True not everyone has access to three phase , but actually the miner will run on any three phase with 380V to 415 V it doesn’t have to be 415 V

    • @vladimirsamselyi155
      @vladimirsamselyi155 5 месяцев назад

      ​@@Crypto_mining_labminer is working only on two phases not three if i have good infos.

  • @rezaarab6788
    @rezaarab6788 4 месяца назад

    من زبان انگلیسی بلد نیستم

  • @samankpgamage
    @samankpgamage 8 месяцев назад

    i live in a freezing country. i send 21 centigrade into my S21 335T but don't start mine it says, "ERROR_TEMP_TOO_HIGH: over max temp" Does anyone know why?
    2024-04-20 12:12:08 water temp 21 ~ 22, stop.
    2024-04-20 12:12:08 set UART baud to 115200
    2024-04-20 12:12:16 Chain[0]: find 216 asic, times 0
    2024-04-20 12:12:23 Chain[1]: find 216 asic, times 0
    2024-04-20 12:12:31 Chain[2]: find 216 asic, times 0
    2024-04-20 12:13:51 too hot water temperature pic temp 56 (min 56)
    2024-04-20 12:13:51 ERROR_TEMP_TOO_HIGH: over max temp
    2024-04-20 12:13:51 stop_mining: over max temp
    2024-04-20 12:13:51 uninit_temp_info
    2024-04-20 12:13:51 do not read temp anymore...
    2024-04-20 12:13:51 uninit_asic_temp_vol_info
    2024-04-20 12:13:51 do not read asic_temp_vol anymore...
    2024-04-20 12:13:51 cancel thread
    2024-04-20 12:13:51 ***power off hashboard***

    • @Crypto_mining_lab
      @Crypto_mining_lab  8 месяцев назад

      it will help a lot if you can send a full load after starting the miner
      you can email it to : info@crypomininglab.net

    • @samankpgamage
      @samankpgamage 8 месяцев назад

      @@Crypto_mining_lab your email not working

  • @KiranKumar-ke5oc
    @KiranKumar-ke5oc 5 месяцев назад +1

    does it make lot sounds like the others ant miner🥲

    • @Crypto_mining_lab
      @Crypto_mining_lab  5 месяцев назад

      no , no where near the noise from a regular antminer , you can run these at home no issue

    • @KiranKumar-ke5oc
      @KiranKumar-ke5oc 5 месяцев назад +1

      @@Crypto_mining_lab amm
      .thanks for reply❤