How many turns pls...and how do you turn the copper coil....does it have a specific method or style? Mine doesn't power up even after using a diode..what could be the problem??
Master, could you please tell me how many turns you made and what number of wire you use? I have a diesel generator staor and it shows 54 ohms, maybe it is overheated, by the way it uses 0.6mm 22 gauge wire
On rewinding my gen, I counted 590 "loops" each side. Given, mine is a 10K watt gen and with 22 gauge wire. There is a website that you can estimate how long the wire is by checking the Ohms and add the gauge- given, the wire is not broken\open loop like mine was originally.
Hello, I'm very curious. Does that rotor have a permanent magnet. If there is no magnet, where is DC current given to the rings on the rotor. Greetings. I am from Turkey. Do you know Turkey.
Yes they have...look carefully 0:07 sec in video. They are small rectangular peaces at the and of the core. But they are only for the excite then you have an AVR (automated voltage regulator) electronics for DC current to the rotor
The AVR is supplied from the stator and it takes voltages information from the main 230V of the stator ...if voltage drops when you load the generator it push more DC current to the rotor
Can anyone tell how to check that style armature with an ohms meter I did the brush tracks and had continuity but I also had continuity when I went brush to shaft is this armature grounding out from the windings to the base please let me know if its good still
This man keeps bothering me with subscribe graphics. No narration or explanation. Spent too much time on cutting paper. Thumbs Down from me for irritating me with onscreen graphics.
Good job, congratulations 👌.
nice work
buen trabajo
ভাই ধন্যবাদ আপনাকে। আমি বাংলাদেশ থেকে দেখছি।আমার ৬৭০০ ওয়াট জেনারেটর আর্মেচার বার বার পুড়ে যাচ্ছে।তারের গইজ নম্বর এবং প্যাঁচ সংখ্যাটা বলবেন প্লিজ।
what"s the name of that liquid substance u pour on the body of that windind?
Good work rewineding alternator
Thanks
🤞🤞🤞🤞🤞🤞
Number of wire gauge? How much weight of wire
wire gauge=23 No.,,,,,,,,weight=920+920 grams.
Ok but you need to show routing of connections.
How many turns pls...and how do you turn the copper coil....does it have a specific method or style? Mine doesn't power up even after using a diode..what could be the problem??
how many ohms one of 8kva and 10kva with wire 23
Master, could you please tell me how many turns you made and what number of wire you use?
I have a diesel generator staor and it shows 54 ohms, maybe it is overheated, by the way it uses 0.6mm 22 gauge wire
On rewinding my gen, I counted 590 "loops" each side. Given, mine is a 10K watt gen and with 22 gauge wire.
There is a website that you can estimate how long the wire is by checking the Ohms and add the gauge- given, the wire is not broken\open loop like mine was originally.
@@h.mandelene3279 what is the Webside? I have a 3K Generator. How many loops i must have?
How many ohms of resistance should one of 8kva and another of 10kva have?
75.
Thanks for advice
Thanks for what you doing, please I have a question: how do I determine the quantity of coil needed for rewinding. Thanks
Отлично!
Good
Good but you have present connection of terminals direction of winding starting!
Hello, I'm very curious. Does that rotor have a permanent magnet. If there is no magnet, where is DC current given to the rings on the rotor. Greetings. I am from Turkey. Do you know Turkey.
yes l know Turkey
Yes they have...look carefully 0:07 sec in video. They are small rectangular peaces at the and of the core. But they are only for the excite then you have an AVR (automated voltage regulator) electronics for DC current to the rotor
The AVR is supplied from the stator and it takes voltages information from the main 230V of the stator ...if voltage drops when you load the generator it push more DC current to the rotor
Yes some have as an added advantage for establishing quick initial excitation.
Kodėl nenasako kaip pajungti apvijas irkaip pradėtj vinioti ačiū
what is the size of the wire sir? If for example, using 0.8 millimetres, is it possible?
2kw to 3kw swg 25
5kw 6kw swg 24 and 23
@@abdulqayyum446
Yesterday I rolled up the wire, but the current hasn't come out yet, sir, is there any input?
Sir aarmechr me Tirn ke heesab se dalege kee vajn ke heesab se
just as I expected: some small piece of paper drop into the wires and can not take it out.
Brother i believe resistance should remain between 5-15ohms
Noup...is around 30-50 ohms depending of kVA
For this type of rotors...
Brass lass router diode canacktion
Can anyone tell how to check that style armature with an ohms meter I did the brush tracks and had continuity but I also had continuity when I went brush to shaft is this armature grounding out from the windings to the base please let me know if its good still
minmum 45 ohm
maximum 70 ohm
if wire is 25 swg
After rewinding my generator rotor there's no power so how did you make the connection
What genertor
1100 of turns to supply you a 220v
Can you please give number of turns and wire size,I'm trying to rewind a brushless rotor as the fan broke the wires.
Number of turn sir?
Sir yekada andi shop
Bhai 7 kw Generator h tar no.
This man keeps bothering me with subscribe graphics. No narration or explanation. Spent too much time on cutting paper. Thumbs Down from me for irritating me with onscreen graphics.
Winding finishing is poor...
गूंगे हो कया?
Bhai app bolo bol ke batao sab kucch
People will give him thumbs down.
Undetailed useless...
Good work