Renogy 100 Watt Solar panel VS Harbor Freight 100 Watt Solar panel

Поделиться
HTML-код
  • Опубликовано: 18 июн 2022
  • In todays video we compare renogys 100 watt monocrystalline panel against Harbor Freights 100 watt monocrystalline to see which proves to put out more power.
    Let me know what you think in the comments below and be sure to smash the like button and subscribe. #solar #renogy #offgrid #rv
    UPDATE!!! So I did verify the wire as being tinned cooper as so many were wondering. Sorry it took a bit to check but I’ll see about making a short video to Update you all. Thanks for the comments and suggestions, appreciate all of it!!!
    Harbor Frieght Panel: https: sovrn.co/1g532mp
    Renogy 100watt panel: amzn.to/3zM3pLb
    Mc4 connector video!! MC4 Install Crimping Easy DIY
    • MC4 Install Crimping E...
    Ask me direct for fast response asqme.com/@johnnysweekends
    CHECK OUT MY AMAZON STORE: www.amazon.com/shop/johnnyswe...
    Buy me a Coffee 👍🏼🙌🏼👊🏼😀
    www.buymeacoffee.com/johnny5120J
    TopTes Gas Detector PEN!!: www.amazon.com/dp/B0B62LBZPC?
    Trailer and vehicle accessories
    www.etrailer.com/?etam=a0017
    Lithium SOK Batteries Solar and more!! currentconnected.com/?ref=JW
    Level your trailer FAST & EASY!!!!
    Level mate pro: amzn.to/3S2xf5c
    AWESOME BUDGET BATTERY Chins w/ low temp and blue tooth! amzn.to/3IOjVfv
    MC4 All in one Kit : amzn.to/37jwLVb
    BEST GAS CAN!! Surecan Gas can : amzn.to/3Kf5rqn
    Protect Everything!! 303 Aero space Protectant: amzn.to/329dkM7
    BEST FIRE PIT!! Outland Propane fire pit!! : amzn.to/3rKIkwZ
    Generator tent amzn.to/3ddd3ds
    Lucas fuel treatment: amzn.to/3IfxQv8
    Videos are for entertainment purposes only. Do your own research when it comes to using these products shown in any Johnny's Weekends videos.
    Thanks for watching. Above links are part of a affiliate program. As an Amazon Associate I earn from qualifying purchases, if you purchase something I earn a small commission, if you do thank you so much as it helps creators like me to continue to bring content for viewers.👍👊😊

Комментарии • 2,6 тыс.

  • @johnnysweekends
    @johnnysweekends  Год назад +196

    UPDATE: Late last evening I went and popped the back panel off the Renogy solar panel to verify if the wire truly was Tinned copper and it was!! Like so many had mentioned. I updated the description and may show a short video for those interested. Sorry for the quick over look. Updated 6 month and 1 year will come later.

    • @SeaJay_Oceans
      @SeaJay_Oceans Год назад +7

      Ok, now hit each one with an EMP and see if either one survives.

    • @johnnysweekends
      @johnnysweekends  Год назад +19

      What would you expect to survive a emp since no one has seen it happen in real life? And these would take a second to fix. A all it would do is pop a diode, maybe. Boom good to go again.

    • @angelvelazquez8493
      @angelvelazquez8493 Год назад +3

      Definitely 💯

    • @SeaJay_Oceans
      @SeaJay_Oceans Год назад

      @@johnnysweekends wow, youtube blocked their own video demonstrating how to EMP test your equipment and ensure your system is hardened against lightening strikes ? Sad to see the truth blocked by communists.

    • @johnnysweekends
      @johnnysweekends  Год назад +12

      I have settings in my account that blocks links on purpose. I had to do this after my account grew and spam was starting to show up everywhere. So unfortunately it blocks other people sharing links as well.

  • @johnclemens3018
    @johnclemens3018 2 года назад +1490

    I appreciate how quickly you give the information- No BS and you jump right to the next point. I'm a fan. Thanks

    • @johnnysweekends
      @johnnysweekends  2 года назад +31

      You’re welcome and thank you… no time for fluff! Well maybe a pinch sometimes 😅👍🏼

    • @cameronbennett5258
      @cameronbennett5258 2 года назад +39

      Didn't even feel like I watched an 8 minute video 🤣 maybe other youtubers can learn from this

    • @johnnysweekends
      @johnnysweekends  2 года назад +22

      I hope not it only helps me 🤣🤣🤣👊🏼👍🏼

    • @WisdomVendor1
      @WisdomVendor1 2 года назад +17

      I could not agree more!
      I get so frustrated with videos such as these where people will sit there and babble for 2 or 3 minutes about nothing that has anything to do with the subject at hand. This is very refreshing.

    • @johnnysweekends
      @johnnysweekends  2 года назад +5

      Thank you 😀👍🏼

  • @jpopelish
    @jpopelish Год назад +369

    Diodes, soldered in with straight leads, will experience mechanical stress between the diode chip and the attached leads, as they expand and contract with heat and cool cycles. If you have a diode failure and have to replace them, put a bit of an S bend in each lead, before you solder it in, to give the leads some springiness.

    • @exgenica
      @exgenica Год назад +11

      The heating caused by the current inside the diode itself is far more mechanically significant than external heating of the external leads. If there is a problem it will show up due to internal heating of the chip itself well before any problem shows up due to heating of the external leads. However...
      Once you're INSIDE the diode package, any difference in the thermally caused mechanical stress due to heating effects on the EXTERNAL portion of the leads is virtually eliminated by the epoxy/ lead bonding...so the "S" shape outside the package doesn't help at the chip/lead interface (and the "lead" interface doesn't actually directly connect with the chip in a way that this aspect would change anyway).
      However, the "S" shape in an external lead CAN help reduce thermally caused mechanical stress at the external lead/connectors whether crimped or soldered. However the lead alloy, shape of the "S", and the diameter and length of the leads would also change the forces due to the change in the increase in length as the lead heats up...so there can be a point of diminishing returns.

    • @jpopelish
      @jpopelish Год назад +21

      @@exgenica Perhaps you have more faith in the rigidity and strength of the epoxy package than I have. But if the leads are soldered between two points, in a straight line, and the distance between those two points changes from diode or external temperature changes, the leads can produce large forces on the die bonds. I have attempted to reduce these forces with lead bends and also soldering a pair of brass strips across the leads, close to the package, and fanned them out, as a heat sink, to reduce the temperature swings generated by the diode chip, itself. I worked in industrial electronics, for a long time, and saw many diode failures. I didn't have a semiconductor lab, to perform proper autopsies. But some doable things seemed to help.

    • @jpopelish
      @jpopelish Год назад +6

      @tallwill38 In old tube amplifiers, the tie point strips and tube sockets were made with purposefully flexible, sheet metal terminals, that would flex, and take the strain off the component leads soldered, at right angles to them. The terminals the diode leads are soldered to, in these junction boxes, look pretty stiff, by comparison. And the plastic boxes those terminals are mounted on, change size, quite a bit, between sitting in the sun on the hottest day, and the middle of the coldest night of the year.

    • @WalterGreenIII
      @WalterGreenIII Год назад +9

      I usually do not solder straight leads, I bend them into a bent L and solder the end of the L. having the lead after the bend long enough usually will serve the same purpose as the S bend.

    • @devilsatan2973
      @devilsatan2973 Год назад

      Your reading way to much into this! The reason NASA specs the "s" bend is because their stuff is launched in a very temperate environment, but then goes to space. It's VERY cold up there! Yet, the device has to work in both environments. The small changes from day to night at your location will not make much of a difference! Your NOT sending something into space folks!

  • @waltbennett5503
    @waltbennett5503 Год назад +235

    I've had four Renogy 100 watt panels on my 5th wheel roof for 8 years now. Absolutely no problems or issues, including being in two hail storms and traveling over 50k miles. They are great!

    • @johnnysweekends
      @johnnysweekends  Год назад +20

      Wow awesome thank you for the feedback..😀👍🏼

    • @zedwolf1589
      @zedwolf1589 Год назад +19

      Thanks Walt, the best advice or recommendations are from the people who have used something for a while.

    • @MarkusAnthony88
      @MarkusAnthony88 Год назад +3

      Looking at the results, you're probably get sub par performance compared to a much cheaper harbor freight set up.

    • @Emma-ol7kf
      @Emma-ol7kf Год назад +20

      @@MarkusAnthony88 Knowing every single harbour freight product - They would have been destroyed by rain drops - let alone hail. I would like to see an impact test done on these panels

    • @johnnysweekends
      @johnnysweekends  Год назад +7

      😀👍🏼 I like it…!!!

  • @scottkolaya2110
    @scottkolaya2110 2 года назад +587

    Great review. I would have never in a million years guessed that the Harbor Freight Panel would outperform the Renogy.

    • @johnnysweekends
      @johnnysweekends  2 года назад +68

      I tried to make the test as equal as possible and even when I have been messing with them the HF are still putting out better numbers. Not that Renogy doesn’t have good stuff but interesting to see the different results.

    • @nightstringers
      @nightstringers 2 года назад +28

      You ,me and a lot of others think the same thing

    • @therealbigfoot3076
      @therealbigfoot3076 2 года назад +7

      I would

    • @pierremitham2964
      @pierremitham2964 2 года назад +11

      The Half cut cells on the HF panel give it an advantage over the Renogy panels (which aren't bvery good panels to start with)

    • @scottkolaya2110
      @scottkolaya2110 2 года назад +26

      @@pierremitham2964 I certainly agree half-cut cells allow for slightly higher watts per sq meter, but we're talking about the same wattage rating on the panels, not discussing their size. On the other hand, I looked up the harbor freight panel and it's 986 sq in and the Renogy is 866 sq in. So the Renogy is less surface area with a less efficient design, it shouldn't be too much of a surprise that the Harbor Freight puts out more actual wattage.

  • @twiddler71
    @twiddler71 2 года назад +337

    I purchased 6 harbor freight panels when they had them on sale for only $89 each. Changed all the connectors to MC4. I like the aspect size of the harbor freight. It seems easier to orient on a ground mount. I also like that the Harbor Freight panels have the plastic protectors on the corners.

    • @johnnysweekends
      @johnnysweekends  2 года назад +31

      Yea the plastic protectors are nice if you plan to move them a lot. $89 is a good buy👍🏼

    • @grantdeisig1360
      @grantdeisig1360 2 года назад +23

      I did the same, 6 panels at $89.99. I think they work very well for the price. Here in Michigan, I typically get about 110 watts per panel on average. I only lose performance on the very hot days. Usually about a 10-20 watt loss. I've had my panels peak at 7.25 amp on a cool sunny day. I would like to get 2 more, but it's disappointing that the price went up.

    • @johnnysweekends
      @johnnysweekends  2 года назад +15

      Wow good numbers. Yea they got popular so price went up some.

    • @keithmanningbocodjkaraoke7259
      @keithmanningbocodjkaraoke7259 2 года назад +2

      I Have 21 100 watt Harbor Freight Panels on sale for $89 on sale n Been Off Grid for a 1year running All of my 30 amp 40ft Park Model Camper Shallow Well Water Pump n My DJ Equipment to for my cookouts n 6000 btu Ac n my Fridge n outside freezer TVs surround sound system n my wife's blow dryers n all my appliances with only 8 101 amp hour a total of 808Amp hours of EverStart Deep Cycle Batteries from Wall Mart at about $109.00 each .

    • @keithmanningbocodjkaraoke7259
      @keithmanningbocodjkaraoke7259 2 года назад +15

      Total of array of 2100 Watts of Harbor Freight 100 watt panels .

  • @WillProwse
    @WillProwse Год назад +23

    Aluminum? Pretty sure that is tinned copper. Not aluminum. PV wire has a lot of strands and feels like aluminum, but it's just how tinned copper with lots of strands feels like.
    Good video!!

    • @johnnysweekends
      @johnnysweekends  Год назад +5

      Will you are correct!! I actually popped the cover plate again last night and checked the wire and you can see the tin coating upon inspection.
      I’ll be updating the description and maybe make a RUclips short just to update everyone.
      Thank you so much for the comment and love your videos ..!!!! 👊🏼👍🏼
      Stay cool!! Cooking up here in Far NorCal!

    • @WillProwse
      @WillProwse Год назад +5

      @@johnnysweekends oh cool!! I made the same mistake some years ago and am still embarrassed I thought it was aluminum 😂 oh nice! What part of norcal

    • @johnnysweekends
      @johnnysweekends  Год назад +2

      Hey no one if perfect, I mess up lots of stuff, well I try not to but how ya learn. 🤷‍♂️😅
      Redding, CA. Where all the fires 🔥 are 🤦🏼‍♂️ lol.
      But did you know it’s the second sunniest city in the nation… ??? Crazy right !

    • @rastatafari7691
      @rastatafari7691 3 месяца назад +1

      My guy

    • @rastatafari7691
      @rastatafari7691 3 месяца назад +1

      I follow ur channel peace bro from Rasta

  • @blackhawk7r221
    @blackhawk7r221 Год назад +33

    We use these 100w HF panels in many places all over the farm. Never had one fail, and most have been up at least ten years. But their $30 charge controller circuit boards tend to corrode rather easily.

    • @johnnysweekends
      @johnnysweekends  Год назад +8

      Awesome, thanks for the feedback.
      Yea the controllers I normally tell people to by pass and get something else. Unless running a real simple set up then sure it will probably do the job.

    • @1949crewchief
      @1949crewchief Год назад +6

      Helpful tip, treat the controller with Corrosion X and hot glue desiccant packs inside. we use these for keeping our coop cooling fans going and after these small additions we have had no problems! 👍

  • @jakenuno9900
    @jakenuno9900 Год назад +11

    I worked for a manufacturer working on high-end prototypes, and a deviation I had to do often was swapping for a more robust connector between the solar panels and the rest of the wiring. It was common for the connectors to be the highest resistance point, thus creating extra heat, and melting the connectors, then eventually shorting and causing further, obvious issues. The fix was adding a much larger connector with larger terminals. The initial engineers expected the original connector to be sufficient, but turned out not to be in real life. Something to think about when swapping connectors. I've always been on the side of don't replace, upgrade, for things like this. Great video!

    • @johnnysweekends
      @johnnysweekends  Год назад +3

      Thank you. And yes the SAE to mc4 would be a upgrade as they can handle much larger amounts of volts/current going through it. 👍🏼
      Thanks for stopping by 👍🏼😀

  • @edwincollins9820
    @edwincollins9820 2 года назад +24

    I bought 8 HF 100 watt panels and installed them on top of my south facing patio cover (4 x 6 inch timbers). I have two arrays of 4 panels each in series giving me 80 volts. These two branches are in parallel. These charge my EcoFlow Delta Max which I use to power my entire house. I am getting 760 watts out of this array starting at 1115 until 1600 or so in San Diego. This is enough to recharge my EcoFlow Delta to 100% in 6 hours. I am experimenting going off grid every other day. So far so good since setting this up in May of this year. I kept the SAE connectors but I removed the aluminum stand arms. Using 2 x 2 alum angle for stationary mount. Very pleased with those HF panels especially when they go on sale.

    • @edwincollins9820
      @edwincollins9820 2 года назад +4

      @Danang Alta yes. I leave the solar line connected full time to.keep it topped off. Using the phone app let's you monitor inputs, outputs. State of charge in real time. I'm really impressed with ecoflow. I run the washer dryer (gas) off it via an extension cord.

    • @gingerkittiesfour
      @gingerkittiesfour Год назад +2

      Question about powering your entire house. Do you have multiple fridge/freezers, central AC, furnace, water heater, electric stove, clothes washer and dryer, and other electronics? I'm wondering how many panels would it take for all of that?

    • @johnnysweekends
      @johnnysweekends  Год назад +1

      Being we install solar, its not just solar but a battery back up is what’s going to run all that unless you want run a off grid system or hybrid types DIY and more.
      My house is pretty simple,1800+SQ with a 5.4kw solar system. I run pretty much net 0 out of pocket each year. Tried to go larger but city would not let me. I do not have a back up system but plenty of options for when the occasion comes for power. Typical system payback like this about 4.5-5.5 years. Most are about that. 5-7 year pay off.
      When the power goes out your solar panels are tied to the grid,so they no longer provide power to the grid spinning your meter back ward so to say. The panels are still making power but no where to go. Hence a battery back up system that works with the solar so if power is out and sun is shinning you are good. As it drains in the night the next day it charges back up again. No you still want to conserve. You can’t burn 200 gallons of fuel if the sun will only bring in 150 gallons if that makes sense.
      Many ways to go for back up power. DIY builds or buy a small power station or a gas generator.

    • @edwincollins9820
      @edwincollins9820 Год назад +2

      @Danang Alta Yes it does. At night it shifts into standby.

    • @edwincollins9820
      @edwincollins9820 Год назад +3

      @@gingerkittiesfour I have eight 100W Harbor Freight panels facing south in a 4P-2S config. Ecoflow limits solar input to NMT 800W. Later I put up another eight panels same config facing east paralleled into the south array. So as soon as the sun comes up the ecoflow comes alive and starts charging. So 800W early morning and at noon 800W as the sun travels to the west.

  • @gizmoguyar
    @gizmoguyar Год назад +43

    Thanks you so much for this review. Straight to the point, no BS. Exactly how these kinds of videos should be.

  • @patriciatinkey2677
    @patriciatinkey2677 Год назад +1

    Thank- you!! This is the basic solar advice channel I need to pull it all together. First time you have popped up on my feed, but now I'm subscribed. Was very glad to see your test of the Harbor Freight panel matched up closely with my meter readings.
    Now I need to watch your other vids to see why I'd need to change the connectors.

    • @johnnysweekends
      @johnnysweekends  Год назад +1

      Glad I could help. Trying to help people get started but explaining it in simple terms with out much of the technical stuff.
      Glad you found me….and feel free to ask questions from me or anyone else to help or get advice you need.
      I try to answer as many comments as I can but sometimes they come in so fast it’s hard…😀👍🏼

  • @rick5793
    @rick5793 6 месяцев назад +1

    I really appreciate your presentation, easy to follow, no personal opinions, straight shown facts. Great job, hopefully others can learn from your format.

  • @randallcrawford4141
    @randallcrawford4141 2 года назад +22

    I'm a Electrician and HVAC Technician, copper is always better than aluminum they use aluminum now only for main power lines to panels or the service drop... aluminum expands and contracts when used for a conductor which causes loose connections and why aluminum for house hold receptacles or outlets is no longer used because they have been the source of many house fires when they use aluminum wire for lighting and receptacles in house wiring!... special anti oxidation and splices with aluminum to copper are used on the house's that still have aluminum wiring....and also a special outlet is sold for this also to combat the issue of aluminum wiring getting loose connections and over heating causing fires or over heating also instead of pushing the wires into the clip holes in the back it is always much better to put the under the screws minding the direction the screw turns to have the wire bent in the same direction to ensure a tight connection that will stay tight longer over the test of time ...many electrical companies and contractors though use the back clip in hole because how quick and convenient they are to install and complete the job ....time is money!...but a good soldered connection always is better just remember to use the proper solder or flux for the electrical and in areas that have water /weather etc. Use proper weather proofing of electrical even bugs or mice etc.moisutre all need to be kept from the electrical..... ...keep them dry and clean...when I was working on panels that had circuits over heating. We used Lazer thermometer to check temperatures of the electrical connections or even thermoheat video meter which is more expensive but can pinpoint all the connections quickly that are overheating. ..have a good day y'all! Stay safe and respect the power of ⚡⚡⚡ electricity ....it only takes about 2 amps to disrupt the beat of a human ❤️. Many batteries can be well over 100 amps and if you ! Used welding with stick electrode and grounding clamp to what your welding and it grounded...could stick weld metal but would be dangerous as it would be a direct short on the battery and it could overheat or explode.. from hydrogen gasses...so under some circumstances even a 12 volt batteries can be dangerous enough to kill someone!
    Work safe and fare thee well!

    • @WizzRacing
      @WizzRacing 2 года назад +2

      That is not Aluminum.. It's Tinned Copper Wire. Used in High grade Audio car stereo systems...It resist oxidation better.

    • @johnnysweekends
      @johnnysweekends  2 года назад

      I’ll have to double check and see if it’s a copper. I’ll cut a mc4 off and strip it.

    • @WizzRacing
      @WizzRacing 2 года назад +3

      @@johnnysweekends You don't have too. I can see the very fine strands of wire. Only Tinned Copper gets that...It's to prevent Corrosion from water or moisture getting in.

    • @boblinda1738
      @boblinda1738 2 года назад +3

      The commercial property I worked at for thirty years was originally built with all aluminum wiring back in the late 1960's. Every year we had to go to our main electrical room and tighten all the lugs because, as Randall said, the aluminum wire expanding and contracting created this situation. If we failed to do it, we would have aluminum wiring arching causing burned lugs and loss of power. By the time I left there all aluminum wiring was gone, the cost of which was depreciated, we have eliminated a potential for fire, and we saved the annual expense of having an electrician go through the property tightening the lugs in the panels. For electrical wiring, whatever or wherever the use, it's copper only for me.

    • @WizzRacing
      @WizzRacing 2 года назад +3

      @@boblinda1738 That was only used in the 1950'e. Due to the lack of Copper.During the rebuilding of Europe after WWII. As copper was expensive to mine ...And only America had the capacity to supply huge amounts of materials for that rebuilding...
      And to stop that. You used Nolox...As the problem was the lugs were Aluminum as well..Which they still are today in new service panels..
      Hell the Main service feed to your house is Aluminum wire. As that is what the electrical company install from the transformer..
      Now you want o go have fun. Go replace Knob and Tubing. It's run the same way. Free air no insulation..Wrapped around insulators..Like the power company runs high tension lines..

  • @bizzaromazzaro9532
    @bizzaromazzaro9532 2 года назад +50

    Cleaner connections, Copper wire, higher amp output, same voltage range, Wow, the harbor freights, if maintained well, outperform brand name panels. How interesting. thank you for the vid. Very enlightening.

    • @johnnysweekends
      @johnnysweekends  2 года назад

      Your welcome..👍🏼😀

    • @adonian
      @adonian 2 года назад +5

      just reading this comment made my decision, thx.

    • @probablynotabigtoe9407
      @probablynotabigtoe9407 2 года назад +5

      Yes Harbor freight is well known for its long lasting quality products... lmfao

    • @johnnysweekends
      @johnnysweekends  2 года назад +3

      Good thing HF doesn’t make them. They just supply them.

    • @puckcat22679
      @puckcat22679 2 года назад +11

      @@probablynotabigtoe9407 In recent years, they've really been trying to change their image and quality. You can still get cheap junk there, but they also have some really good quality stuff on the shelf now. As for these solar panels... the HF panel is objectively better than the Renogy. Copper wire vs. aluminum (copper is a better conductor but aluminum is cheaper, and price is the only reason to use it vs. copper) soldered connections instead of just crimps (soldering takes longer in production, but crimps are subject to oxidation if not done perfectly, and can loosen over time, especially on aluminum which is not as elastic as copper)
      Finally, there's the appearance of the inside of the junction box. The Renogy panel looks like it was assembled by someone who didn't give a f*** about their work- the diodes just shoved in there almost sideways, with bent leads and connections just kind of half-assed. The HF panel on the other hand looks like it was assembled by someone who has pride in their work- the diodes are in there straight, the connections are neat and look good. Literally the only cost cutting measure I saw was the use of SAE connectors instead of... Whatever the standard ones are called. The SAE connectors aren't as weather resistant and don't have positive locking tabs. However, there's actually a good reason to use them here- HF markets these panels to RVers and other people who are primarily planning to use them for charging 12 volt lead acid batteries, and those SAE connectors are a standard connection type for that. They're used on boats, RVs, and battery chargers everywhere.

  • @user-mm6xi3er5u
    @user-mm6xi3er5u 2 года назад +49

    Great review. I bought 6 - 100 watt harbor freight panels when they were on sale for $99. Also bought a Bluetti AC200 max and 4 370 watt Santan Solar panels. Ready for power down and retreat living off grid.

    • @johnnysweekends
      @johnnysweekends  2 года назад +7

      Nice, yea if you can get the coupons you can get some deals on these.!! 👍🏼😀

    • @cupcakemcgee3175
      @cupcakemcgee3175 2 года назад +5

      Bluetti ac200max was my best purchase in a while

    • @metaglypto
      @metaglypto 2 года назад +8

      I also have the same Bluetti power station. I use it for camping and backup power for the house. Great power station and nice size.

    • @KC-dr3cg
      @KC-dr3cg 2 года назад +1

      So what I'd like to know is is it simple to plug a solar panel into a solar charger and then have a 110 Electric plug-in readily available or do you have to have some technical knowledge about how to connect the solar panel to the charger

    • @metaglypto
      @metaglypto 2 года назад +3

      @@KC-dr3cg Yes and no. Totally depends on you and what you buy. it is super easy to connect a solar panel to a "solar charger" if both the panel and charger were made by the same company, such as Jackery or Bluetti. To connect a Renogy or Harbor Freight panel to one of those solar chargers may be a bit more difficult, if you have no knowledge of electricity or solar type connectors. Companies that make both solar panels and solar power supplies, make them as true plug and play units, and often have bundle deals. Both companies also make their solar power supplies with built in, 110 electric plug-in, 12 volt, and USB outlets. I own both Jackery and Bluetti, but prefer the Bluetti, as it has a bit better battery chemistry, which makes it faster to recharge, depending on the number of solar panels you get. Side note: Off brand solar panels will often have a selection of different connectors that make them compatible with most popular brands of solar chargers.

  • @cmdrredhawk
    @cmdrredhawk Год назад +21

    You had the perfect setup to test how blocking a single cell, or part of the panel effects performance. Like shading the lower 1/4th of the panel. Also another + comment on getting to the point and showing the content. Great video.

    • @johnnysweekends
      @johnnysweekends  Год назад +13

      I did the shade test and edited it out added like 4 mins and both suffered greatly but the renogy did slightly better like a volt or two more but no watts.
      Hard with just a single panel.
      But I did 80% 50% 30% 25%
      Changed the shade area to go over certain parts of the cells on that string and more and both really did t produce anything unless about 90% uncovered .

    • @johnnysweekends
      @johnnysweekends  Год назад +2

      Oh and thank you, appreciate it..😀👍🏼

    • @CaptainSeamus
      @CaptainSeamus Год назад +1

      @@johnnysweekends Good video.
      The shading thing is kind of tricky until you get how the wiring of the cells works. An individual cell being shaded will take out the entire string due to the protection diodes that will "shut off" a string in the PV to protect against fire in that string.
      There's actually a lot to it, but it shows up with those drops you noted.
      Look very carefully at the PV and note how the busses are wired to figure out orientation... then block one or more cells on a given string to see the whole string cut out.

  • @dougrobertson87
    @dougrobertson87 Год назад +14

    I bought the Harbor Freight panel for $99. I have only used once while dry camping. It did a great job of charging up the batteries on my RV. No regrets so far.

    • @johnnysweekends
      @johnnysweekends  Год назад +1

      Nice, most times you can always find a coupon for $99 so make it a decent buy.
      Thanks for the feedback..😀👍🏼

  • @housesOTR
    @housesOTR Год назад +60

    I was at our Harbor Freight store when they first came out. They were $99 so I bought two of them. They are for backup. I connected them together with hinges to make a suitcase. Heavy but easy to store.

    • @johnnysweekends
      @johnnysweekends  Год назад +12

      Yes they are great for a mobile build like a suit case to throw in the truck for camping or little power stations

  • @alexlew5039
    @alexlew5039 Год назад +1

    This is a godsend for Hurricane season here in New Orleans. I might even make this my new side hustle . Thank you for this amazing video.

    • @johnnysweekends
      @johnnysweekends  Год назад

      There is always a side hustle and small solar hook ups or back up battery stuff to run internet and a fridge is huge..👊🏼👍🏼

  • @michaeltichonuk2176
    @michaeltichonuk2176 2 года назад +1

    Most Excellent presentation! Almost ordered a Renogy panel to go with rest of Renogy system. So glad you posted this. Many thanks!

  • @davep2945
    @davep2945 Год назад +15

    I see a lot of people here commenting on the Renogy panel being better because they "know" it will be better over time. Perhaps that's true but until the theory is tested it remains merely an opinion. Plenty of guys use HF air tools without issue for years while doubters claim their Snap On's will last three times as long. Again, perhaps that's true but at three times the price what's the difference? Obviously these panels don't have that big of a price difference so it may be a wash. Also, the type of copper is a factor. Copper is a better conductor but if not OFC free or very well insulated it will corrode and become brittle and then snap after several years. But that can happen to aluminum as well.

    • @bubbledoubletrouble
      @bubbledoubletrouble Год назад +1

      “at three times the price what’s the difference?”
      You don’t have to waste any time procuring a replacement. And since prices are always going up over time-even when inflation isn’t high-your second and third ones will cost more, so it will have been _less_ than three times the price in the end. And that’s not even getting into the extra trash from needing to buy two more.

    • @markmcdonnell6947
      @markmcdonnell6947 Год назад +1

      Most of my tools are Rigid,Milwaukee & Dewalt love them & stand by them. But for many reasons I've had to run out to quickly buy a tool. Harbor Freight was close the first time I needed to grab a hammer drill quickly. Had it several years now & no problems. Other tools I've bought there cordless drills, grinder, screw gun & air comp. All have made their money & stood the test of time. They are a bit louder than my other tools & the small compressor takes more time to fill. But have no complaints & not worried About a $300 multi tool falling off staging,ladder or roof when the rookies use them on the job.

    • @johnnysweekends
      @johnnysweekends  Год назад

      Somethings are great for a one time job and are expected to be thrown away. But they keep working and eventually a few years later your like, huh this stupid thing still works good. 🤷‍♂️🤷‍♂️😅👍🏼

  • @MissionaryForMexico
    @MissionaryForMexico Год назад +18

    I am surprised how well the Harbor Freight panel did in this comparision. It also revealed how many panels I would need to power up one roof top a/c for my fifth wheel trailer! That would come to 17 panels!

    • @johnnysweekends
      @johnnysweekends  Год назад +6

      Well if you can use bigger panels go that route. 200 watts or larger. Just depends on the lay out and how much room you have. And in all honesty running a AC in trailer is expensive and can take along time for pay back. A generator is still cheaper in the long run and you can keep the generator.

    • @jakeeddy9256
      @jakeeddy9256 Год назад +7

      Get a 12v swamp cooler. As long as you have water and it's not too humid, it works quite well.
      You can run a evaporative cooler on maybe 2 panels, pump needs included.

  • @judivowell5748
    @judivowell5748 Год назад +2

    Thank you for making it easy to understand for someone who doesn't know much about the solar panels. I have portable panels but I'm thinking about adding one panel to trickle charge my house battery. This video helps me a lot.

  • @willymags123
    @willymags123 Год назад +1

    I love the editing on this you're doing an amazing job! The bus is coming out so beautiful! Ashton you are such a good sport you all make me laugh. Till next time, God bless.

    • @johnnysweekends
      @johnnysweekends  Год назад

      Thank you, and I’ll tell Austin the bus is looking great 😀👍🏼
      I need to find out who Austin is first 🤔😁

  • @bruceallen6016
    @bruceallen6016 Год назад +12

    Interesting test. I'm impressed with the HF panels meeting and exceeding the Renogy ones. Thumb up.

  • @AeschylusShepherd
    @AeschylusShepherd 2 года назад +23

    Just incredible technology. I am just blown away how far solar has progressed, and it's getting better and better! Thanks for sharing!

    • @johnnysweekends
      @johnnysweekends  2 года назад +2

      I agree it’s getting way better. Imagine 5 years. This size panel will be double output. And bi facial may really be pumping a lot more as well.
      Thanks for the comment and thanks again for watching

    • @gregthomas5699
      @gregthomas5699 Год назад +1

      @@johnnysweekends I still use the panel I bought in 1982. The only big change is price went down.

    • @johnnysweekends
      @johnnysweekends  Год назад

      See and people ask, well how long with these even last.
      Some of the original designed solar panels are still putting out power today. 👍🏼
      Yours is a great point. They still work

  • @buscampers
    @buscampers Год назад +2

    This video sold me on the HF panels. I installed 2 of them on my skoolie last weekend after picking them up on sale for $89/ea. They work great. Thanks!

  • @ElectricPoliville
    @ElectricPoliville Год назад +2

    Good test, I agree the soldered connections shows how well the solder connections are on each cell.

  • @BLAM777
    @BLAM777 Год назад +4

    Quick and to the point 👍. We're still trying to figure out what we want for a solar system at our off grid cabin and this helps. Think i may go with the harbour freight panels. Thanks.

    • @johnnysweekends
      @johnnysweekends  Год назад

      If you can fit larger panels then it will be much cheaper per watt.

  • @joejohn5398
    @joejohn5398 9 дней назад +1

    I’m no fan of HF but one who deals a lot with with electrical, HF stepped up their game.

  • @Tacticaldesertdweller
    @Tacticaldesertdweller Год назад +1

    I’m really happy to see this video because I just bought the same set up. Thank you for your time and effort.

    • @johnnysweekends
      @johnnysweekends  Год назад

      Your welcome and thanks for stopping by 😀👍🏼

  • @Refus777
    @Refus777 Год назад +4

    Well prepared, straight forward presentation! Thank You for giving us just the honest facts! Well done!

    • @johnnysweekends
      @johnnysweekends  Год назад

      Thank you and thanks for watching 👍🏼😀👊🏼

  • @johnm.harper773
    @johnm.harper773 2 года назад +14

    I have bought both, and the Harbor Freight panels give me a little more volts and amps, but I also like the Renogy panels!

  • @DavidSmith-ox9ub
    @DavidSmith-ox9ub Год назад +1

    Thank you for this test. I keep thinking about buying a kit for my outdoor shed.

    • @johnnysweekends
      @johnnysweekends  Год назад

      Ahh nice. Yea so many good uses for it. Charging up the tools or now electric lawn mowers and more!! Man cave!!!!!

  • @spasmonaut10
    @spasmonaut10 Год назад +1

    Please do some long-term follow up findings on these panels. Glad I found this video. Very good information!

  • @OnHoldAt50
    @OnHoldAt50 Год назад +4

    Second independent review I've seen comparing these same panels, with the same result. I may have to take back everything I ever thought bad about HF.
    One interesting comparison that might cost a few bucks is a destructive test (how well they would hold up in a hail storm). Thanks OP for the thoughtful review and time it took to publish it.

    • @johnnysweekends
      @johnnysweekends  Год назад +1

      Thank you appreciate the feedback.
      And, well it may seem like a good idea! 😁👍🏼

    • @allaboutroofing2
      @allaboutroofing2 Год назад +2

      Depends on size of the hail. At about golf ball size, all bets are off reguardless of manufacturer. Also hardness qnd density of the hail ball makes a huge difference. For this reason, you will have a hard time finding a correct answer to that.

    • @johnnysweekends
      @johnnysweekends  Год назад +1

      I agree it would be more for fun and to see how much they can sustain versus say a normal residential panel

  • @johnm.harper773
    @johnm.harper773 2 года назад +23

    I just tested both the Harbor Freight and Renogy panels again with sun out very bright! The Harbor Freight are running a little over 100 watts, 5.2 Amps, and 20+ volts, and the Renogy is running a little over 80+ watts each, but they are not side by side, so it is not a complete accurate test, but the Harbor Freight panels are testing a little better wattage!.

    • @johnnysweekends
      @johnnysweekends  2 года назад +2

      Yea the HF do really well. Surprised really.
      Thanks for the feed back.

  • @btakin8737
    @btakin8737 2 года назад +1

    Thanks! You are way easiest to listen to than Will! Helped in my decision making

    • @johnnysweekends
      @johnnysweekends  2 года назад +1

      Wow thank you. Glad I could help..😀👍🏼

  • @Patrickjohnphotography
    @Patrickjohnphotography Год назад +1

    Thank you for having the time and equipment and knowledge to use me decide. Great video!

    • @johnnysweekends
      @johnnysweekends  Год назад

      You’re welcome glad it helped and thanks again for watching 😀👍🏼

  • @solarguy6043
    @solarguy6043 Год назад +28

    Another excellent episode! In general, the quality of all solar panels has improved over the years. Also pretty likely HF doesn't make their own panels, and there aren't a huge number of manufacturers out there. Might both come from the same plant.
    Also note that IR thermometers can get very inaccurate if not held close enough, and if not held at something close to 90*. They can also produce very different and inaccurate readings if the surface finish is shiny vs matte. For comparisons, just put a piece of black electrical tape on both objects to remove that source of error from reflectivity.

    • @johnnysweekends
      @johnnysweekends  Год назад +4

      Yes the solar panels are definitely getting better from every manufacturer as the tech gets better. And correct harbor freight does not make there panels no do a lot of companies it’s all sourced out from a major supplier. I don’t know how much of HFs stuff is made by them if any. It might all be made from a company who they contract with.
      And thanks I’ll try the idea on the next run of testing to see if there are some differences in temp accuracy 👍🏼😀

    • @davemi00
      @davemi00 Год назад +2

      @@johnnysweekends I’m guessing Chÿna made.

    • @johnnysweekends
      @johnnysweekends  Год назад +1

      Both products say China like 90% of the stuff we buy now 🫤

  • @ronrico2620
    @ronrico2620 Год назад +17

    The solder vs crimp debate is easy. If it moves crimp, if it's stationary solder. When a stranded wire is soldered it becomes solid. If it flexes often stresses can cause the soldered wire to snap. Boats, car, motorcycle wiring gets crimped for me; with a coat of oxguard for corrosion

    • @andrewt9204
      @andrewt9204 Год назад +1

      Yeah, I used to solder almost every terminal until they started breaking just below the solder point. As you said, it turns a bit of the wire into solid core and fatigues quickly. Stationary or anchored wire, yeah soldering is good.
      However, I crimp almost everything now that's not on a circuit board. Whether it's wire ferrules, crimp connectors with a good ratcheting crimper, or ring terminals with a hydraulic hex crimper. I use some dielectric grease or deox-it spray on the wires before crimping to make sure the connection between wire and connector stay clean.

  • @JJHDZ68
    @JJHDZ68 Год назад +1

    Another great video!
    Big THANKS to you for taking your time and educating us.
    Blessings!

    • @johnnysweekends
      @johnnysweekends  Год назад

      😀👍🏼🙌🏼🎄🎁 Merry Christmas and a happy New Years

  • @paxmagellanic498
    @paxmagellanic498 Год назад +2

    Great review! And surprising too! I guess HF has been improving their products on the down low. Keep up the good work!

  • @terrywereb7639
    @terrywereb7639 2 года назад +13

    The soldering on the Harbor freight is sloppy, but, as another poster stated, aluminum " cant" be soldered. Actually, it can, but it takes extra heat and some skills that most companies dont want to pay for.
    The Aluminum wires will corrode quickly.

    • @bullshitstomper9417
      @bullshitstomper9417 Год назад +2

      Don’t even bother with anything lower than 350 watts for a panel

    • @johnnysweekends
      @johnnysweekends  Год назад +3

      You can’t always throw a 350 on a Rv or truck camper or smaller sail boats.
      All depends what you need

    • @2pist
      @2pist Год назад

      Sloppy? Pretty doesn't help performance. Aluminum wire is copper coated for solderability.

    • @scottleggejr
      @scottleggejr Год назад

      @@2pist Not all wire is CU coated AL. I would rip that shit out and solder in some TXL or SXL if I were using those chinese panels. I think the conclusion here is both of those panels are trash. If I had something where solar were important, I would double the design N+1, and make sure it's a reputable brand with a warranty both on function and performance like an LG. See SAE J-1128 for reference.

  • @migmigjohnson6083
    @migmigjohnson6083 Год назад +25

    A 1 year follow up would be nice. These things tend to degrade the most during the first years and Renogy is supposed to be the better brand.

    • @johnnysweekends
      @johnnysweekends  Год назад +12

      I will be doing one soon..👍🏼😀

    • @freeranger1677
      @freeranger1677 Год назад +2

      MigMig Johnson - To give you an idea, my 100W Renogy panels have been on my camper van roof for three and a half years. I am getting over 94W per panel using a Victron SmartSolar MPPT 100/20 which has a peak efficiency of 98%. So the panels are approx 4% (4W) below spec after three and a half years. I hope that helps.

    • @johnnysweekends
      @johnnysweekends  Год назад

      Thanks for the feedback always good to get more user feedback for people to read. 👍🏼😀

  • @azfarsyed7082
    @azfarsyed7082 Год назад +1

    Good, America years 2076 , 300 hundred years old.Hope this environmentally friendly Solar system can help all Citizens.NEED to learn basic skills to install .Thanks sharing.

  • @richeastmain4031
    @richeastmain4031 2 года назад +13

    Thanks for the thorough tests. I have wondered those 2 panels compare. I have 6 of the Harbor Freight panels that I purchased when they had a coupon that let you buy up to 4 (they let me get 6) at $89. I use them for my travel trailer with a Victron charge controller and also for my Bluetti E55 and AC200P. I changed some of them to MC4 connectors and left the sae plugs on 2 of them and use adapter cables. The Bluettis each came with cables to use MC4 for input. They work great in series or parallel and in good sun consistently give the rated output, occasionally a bit more. I am very impressed with the quality and performance of them.

    • @johnnysweekends
      @johnnysweekends  2 года назад +2

      They really are impressive how well they do. I wish they made larger ones lol.

    • @friedrice5292
      @friedrice5292 2 года назад +1

      WOW... that's great! May I ask what coupon did you use? Where did you get that? I would like to get couple of the 100 watts panel from HF. Thank you. Cheer!

    • @richeastmain4031
      @richeastmain4031 2 года назад +5

      @@friedrice5292 It was a coupon I got in my email from them. That was several months ago. I did see a coupon last month for $99. If you go on the HF website they usually have the specials listed.

  • @stevekeller7696
    @stevekeller7696 Год назад +6

    Excellent job, thanks. I'll take copper and solder over crimped aluminum any day. I've tested solar panels and never seen one at spec like that. Good to know.

    • @johnnysweekends
      @johnnysweekends  Год назад

      Right even at a decent temp as well. I’m curious when it’s 65 degrees ..👍🏼

  • @tombrewsaugh1399
    @tombrewsaugh1399 2 года назад +55

    As a retired electrician 14 awg copper carries more load than aluminum of the same size. The Rinergy may do better if they increased the aluminum wire to 12 awg and soldered all the connections. Good test though thanks.

    • @johnnysweekends
      @johnnysweekends  2 года назад

      Thank you..👍🏼😀

    • @Trialnerror
      @Trialnerror 2 года назад +5

      That's not copper in the HF panel, it's copper clad aluminum FYI.

    • @PeterTrimboli
      @PeterTrimboli 2 года назад +3

      @@Trialnerror how could you tell usually I gotta look at the tip of the conductor it wasn't clear in the video to me

    • @MicahFunk
      @MicahFunk Год назад +3

      @@Trialnerror I believe copper clad aluminum (CCA) should be outlawed. It's junk and won't last long at all in the elements. It's getting difficult to even find cat5 or cat6 network cable that isn't CCA. It works at first then it eventually breaks connection.
      Have you had any success using CCA?

    • @rockytop441
      @rockytop441 Год назад

      Tom were you IBEW?

  • @jonathankuhn483
    @jonathankuhn483 Год назад +1

    Great video! Clear, concise, and helpful!

    • @johnnysweekends
      @johnnysweekends  Год назад

      Thank you glad it was helpful and thanks for watching 👍🏼😀

  • @woodyifhecould4024
    @woodyifhecould4024 2 года назад +80

    Aluminum degrades fairly quickly when wet. I lived at a couple of different campgrounds who had used aluminum wire on the meter boxes and there were major problems either white corrosion at connectors or anywhere it was exposed to moisture although it was run in plastic conduit there were problems

    • @g.4279
      @g.4279 2 года назад +18

      Depends a lot on the grade of aluminum. Aerospace and marine grade alloys are very corrosion resistant and typically very strong.

    • @bretmohler9719
      @bretmohler9719 Год назад +14

      @@g.4279 true but what grade is usually used for wire applications. many alloys of AL would be too brittle to be used in a wire form so perhaps the marine grade is great at corrosion but terrible when stranded and carrying current. I honestly dont know, but carrying current is one of the largest factors on increase in oxidation rate. They use AL wire for large transmission lines so we know it can be a cheap material to delivery large amounts of energy but what grade they use vs this panel, and how much flex they expect it will need to tolerate will determine how exotic they can go. would be interesting to know for sure.

    • @garethbaus5471
      @garethbaus5471 Год назад +6

      @@bretmohler9719 high voltage lines are made from 1350 aluminum a grade that is at least 99.5% pure aluminum with limits for certain elements that could reduce conductivity. I doubt many aluminum alloys would be cheaper or easier to work with, so the lower voltage lines are probably at least reasonably similar.

    • @bretmohler9719
      @bretmohler9719 Год назад +5

      @@garethbaus5471 ok good info. So then looking at the conductivity chart it has a 62 while a marine grade 5083 has a 29. So the corrosion resistance is prob not worth a 50 percent loss in conductivity. I didn't look up anything about how ductile they are compared to each other.

    • @johnnysweekends
      @johnnysweekends  Год назад +12

      Alright now you guys are going beyond me lol.
      Uhhh now I have to go read ..😂👍🏼

  • @jamesgizasson
    @jamesgizasson 2 года назад +7

    Fascinating! One of the next steps in my pickup build is to 'solarify' the camper shell. Nice to know HFT still offers quality! :3

    • @LanternLabs
      @LanternLabs 2 года назад +2

      I.think HFT has increased its quantity in the last couple years.

    • @johnnysweekends
      @johnnysweekends  2 года назад +1

      Totally, well at least on some stuff..👍🏼

    • @jamesgizasson
      @jamesgizasson 2 года назад +1

      @@johnnysweekends True. I LOVE their wrenches and socket sets!
      I haven't had great luck with their power tools (bought years ago), but they are cheap and do last long enough to justify the purchase. I'm curious about their new Bauer grinders... they look well made. :3

    • @michaelwillman5342
      @michaelwillman5342 2 года назад +2

      @@jamesgizasson Bauer and Hercules are good products, way better than the old Chicago Electric junk.

    • @jamesgizasson
      @jamesgizasson 2 года назад +1

      @@michaelwillman5342 Nice! Thanks for the input. :3

  • @FESLIVENYC
    @FESLIVENYC Год назад +1

    Dude this is the first video I watched on ur ch👍 best of luck thanks please never sell out always be honest God like

    • @johnnysweekends
      @johnnysweekends  Год назад +1

      Thank you so much and I try ..👍🏼😀🙌🏼

  • @brandonboulton2776
    @brandonboulton2776 2 года назад +1

    Absolutely the best no bs review. Thank you.

    • @johnnysweekends
      @johnnysweekends  2 года назад

      You’re welcome and thanks for watching 😀👍🏼

  • @spacecase0
    @spacecase0 2 года назад +37

    I have a 100 watt renogy panel that I have had for about 5 years. The glass is perfect but the silicon cells underneath have mostly fractured. It gives out less than 2 amps in full sun now. I am definitely going to replace it with the Harbor Freight panel

    • @Texasprepper
      @Texasprepper 2 года назад +6

      they have a 25 year warranty

    • @spacecase0
      @spacecase0 2 года назад +5

      @@Texasprepper I read the warranty very carefully. It does not cover environmental damage. Clearly this was done by temperature cycling from the environment. I don't know if they will decide to cover it anyway

    • @Texasprepper
      @Texasprepper 2 года назад +5

      @@spacecase0 it wouldnt hurt to try.

    • @spacecase0
      @spacecase0 2 года назад +3

      @@Texasprepper I agree that it wouldn't hurt to try. But I just found out a few days ago and haven't tried yet. I replaced my battery bank and I noticed it when I was testing the entire system.

    • @JohnThomas-lq5qp
      @JohnThomas-lq5qp 2 года назад

      @@spacecase0 Good luck with any warranty issues on garbage made in cheating lying communist china. Just ask contractors about houses that had cheating china extremely toxic sheetrock. Cost the average homeowner $80,000 to have all insulation, poisonous china sheet rock, all the wires ,copper water lines and plumbing faucets.

  • @dongoble1792
    @dongoble1792 2 года назад +4

    I bought one of those harbor freight Thunderbolt 100 watt panels for my Bluetti solar generator and it works so well that I bought a second one and for less than half the price of most other brands.

    • @johnnysweekends
      @johnnysweekends  2 года назад

      Awesome thanks for the feedback..😀👍🏼

    • @virt1one
      @virt1one 2 года назад

      Dokio is another good brand, available off Ali Express, often with US stock for 5 day ship times, and is typically around $75 for a 100w panel.

  • @wrongwaygarage
    @wrongwaygarage Год назад +1

    Excellent video!!! You get straight to the point without a whole lot of jibber jabber (like my stuff). Lol I love it when a harbor freight product does better in a comparison test. Harbor freight does not always make crappy stuff and it’s nice to see a video that acknowledges that. 👍🏻

    • @johnnysweekends
      @johnnysweekends  Год назад +1

      Thank you, and I agree some stuff you stay away from. Some you buy to throw away, and some is actually not to bad! I think the mighty vac canister is great!! I use that thing a lot and still sucking stong!! 🤣🤣👍🏼

    • @wrongwaygarage
      @wrongwaygarage Год назад +1

      @@johnnysweekends 😂👍🏻

  • @hueypilot1950
    @hueypilot1950 2 года назад +1

    Quick and complete. Well done.

  • @markskeldon1347
    @markskeldon1347 Год назад +34

    Copper wire and the solder connections are superior to the aluminum wire with crimped connections. Also the gasket seemed to be seated better.

    • @enki2gold
      @enki2gold Год назад

      I beg to differ.

    • @gregthomas5699
      @gregthomas5699 Год назад +1

      Apparently he is now saying it was copper, not aluminum.

    • @johnnysweekends
      @johnnysweekends  Год назад +6

      I said it was coated copper along time ago. Only a couple days after video came out. But no one reads the description or pinned comment..🤷🏼‍♂️

  • @jekkershinator4671
    @jekkershinator4671 Год назад +3

    Cool informative Video. I would think new Copper will be more efficient than aluminum wire new to new but over time and exposure it would be interesting to see if the copper had more energy transfer loss as any corrosion may develop. Also an upgrade to either of these would be to use marine tinned wire especially if its used in Damp to wet exposure over time. Being IP67 rated I would say Tinned wire for longevity if you use in damp to wet environments.

    • @johnnysweekends
      @johnnysweekends  Год назад +1

      I did update the description and comment area that the renogy is using tinned copper but sorry it took a while to update. But I’m not sure anyone is reading it..🤷‍♂️

  • @stephaneroy8415
    @stephaneroy8415 Год назад +1

    I guess we can call this an excellent demonstration , i love the way you do it , keep up your good work , if i were you, i'd make a video to show people how to make excellent video , i could i've watch it for hours.

    • @johnnysweekends
      @johnnysweekends  Год назад

      Wow thank you, appreciate it..😀👍🏼
      I do have other videos for your viewing pleasure 😂👍🏼👊🏼😉

  • @EvaderGuy
    @EvaderGuy Год назад +1

    Great comparison testing. Thanks for the video

    • @johnnysweekends
      @johnnysweekends  Год назад

      You’re welcome glad you liked and thanks for watching 😀👍🏼

  • @jackjones9886
    @jackjones9886 Год назад +11

    Nice video and thumbs up to HF to make a affordable panel that gives us experimental guys something to work with. I bought the 100 watt four panel version and found that it was a pain to work with. So I bought the single 100 watt panel for ease of use. Would really like to see you compare the harbor freight to HF panels and see if there is any advantage, being both are the same price.

    • @johnnysweekends
      @johnnysweekends  Год назад

      Thank you. And sounds like that might be a good idea. May have to add that to the list later.

  • @vukken99
    @vukken99 2 года назад +32

    Conclusion: Harbor freight is better...

  • @barrykery1175
    @barrykery1175 2 года назад +1

    That was very interesting and showed unexpected results.
    Thanks for posting.
    Barry

    • @johnnysweekends
      @johnnysweekends  2 года назад

      Your welcome and thanks for watching 👍🏼😀

  • @jimh3777
    @jimh3777 Год назад +1

    Good review, wished I would have caught it before I ordered the Renogy package. Will pick up the HF units for my add ons for sure.

    • @johnnysweekends
      @johnnysweekends  Год назад +1

      Well if you already have renogy it may be better to stick with that even though voltages are pretty close.
      Unless you plan to do a second array and different controller. But if adding on stay with the same..👍🏼

  • @WisdomVendor1
    @WisdomVendor1 2 года назад +16

    All wire connections that are to be considered as permanent should always be soldered. A well done solder joint will always have less resistance than a slide connector / butt connector and resistance is your enemy especially when power delivery is your goal.

    • @Step-n-Wolf
      @Step-n-Wolf 2 года назад +2

      Not so. When assembling cables for solar systems they are all crimped. Have read not to solder them and the reasoning seemed solid.

    • @mikejohnson9118
      @mikejohnson9118 2 года назад +2

      That's not accurate. When we build $$$$ power supplies we went copper/connector. I asked the engineer why. He said less resistance and heating issues in the long term. But we used very nice professional grade crimpers and connectors.

    • @drxym
      @drxym 2 года назад +2

      Electricians rarely use soldering for other electrical installations so I don't see why it would be necessary for solar. They'll use connectors, terminals, splices or crimps in places where they are joining one unit to another. Not only is it faster but it makes it easier later if you need to replace units or do other repairs / modifications.

  • @davidjames1063
    @davidjames1063 Год назад +15

    Copper wire is infinitely preferred over aluminum, especially when you consider LONGEVITY. Unless those aluminum connections are well sealed, they will oxidize, over time & exposure. The choice for me is CLEAR.

    • @tomwilson2112
      @tomwilson2112 Год назад +1

      Agreed. I don't trust crimp connectors. If I was using this panel, I would solder all the connections.
      Also, that solder connection on the right side of the Renogy panel looked pretty sketchy. I'd probably re-do that, too.

    • @davidjames1063
      @davidjames1063 Год назад +1

      @@tomwilson2112 As would I. Nor do I trust "weatherproof" claims. I weatherproof to MY standards, not some Factory.

    • @davidjames1063
      @davidjames1063 Год назад

      @@tomwilson2112 I am going to experiment with the HF panel. I'm thinking of using Reflectors around the panel, to increase the amount of light hitting it, at any given time. If my guess is correct, it should increase efficiency overall by as much as 5%. I suspect that on overcast days, those reflectors will increase output as well. I am doing small scale experimenting, before doing anything larger. I just wish we could get those 34% panels sold ONLY in China. The US syndicate (Gov) blocked sales in the US.

  • @FizzleFX
    @FizzleFX 2 года назад +1

    A good test you got there. Very fair and transparent. I like that. IF ONLY others did that instead of reading of the box and claiming winners based on "the producer claimed it could... X"

    • @johnnysweekends
      @johnnysweekends  2 года назад +1

      Thank you..👍🏼😀

    • @FizzleFX
      @FizzleFX 2 года назад +1

      @@johnnysweekends we thank you.
      I quite frankly done with conga reporting. One false claim parroted around the world....
      No one putting in a minute of research to dis/prove it.
      Solar Freaking Roadways.
      Do i need to say more? ;(

    • @johnnysweekends
      @johnnysweekends  2 года назад

      I thought the solar roadways was cool. But probably not in our life time 😅

  • @MrDANGEROUSIDEAS
    @MrDANGEROUSIDEAS Год назад +2

    great review just information no sales pitch I found this very useful

    • @johnnysweekends
      @johnnysweekends  Год назад +1

      Thank you so much glad you liked..👍🏼😀

  • @qolspony
    @qolspony Год назад +3

    I have a similar HF looking HSQT panel. These panels, at least the HSQT are lighter and easier to move. So I made it a point to not buy longated panels in the future. When I move them for storage, I just tie them together. And I can carry each set on one hand. So I'm moving four instead of two longated panels. They are really almost like carrying a kit.

    • @johnnysweekends
      @johnnysweekends  Год назад +1

      Sounds like the solar suit case so made out of the Hf panels. You should check out the video. Cheap build

  • @Tommyr
    @Tommyr 2 года назад +7

    Aircraft and spacecraft always use crimp connections because they are more reliable than solder. Solder can crack and break. That Harbor freight panel works surprisingly well! I use a Baldr 120 folding panel to charge my 2 Bluetti's. I have a EB70 and the new EB3A. LOVE the new display on the EB3A!

    • @johnnysweekends
      @johnnysweekends  2 года назад +1

      I to am surprised how well the HF panel does. And they use copper wire as opposed to aluminum.

    • @Tommyr
      @Tommyr 2 года назад +1

      @@johnnysweekends The do seem excellent.

    • @johnnysweekends
      @johnnysweekends  2 года назад +2

      Yea if you buy with a super coupon then totally..👍🏼

    • @jimlynch9390
      @jimlynch9390 2 года назад +6

      The marine industry also uses crimp connectors. If you use soldered connections on a boat/ship and it's liable for inspection, it won't pass.

    • @johnnysweekends
      @johnnysweekends  2 года назад

      Wow didn’t know. Thanks for the info..👍🏼😀

  • @brianbelliveau5551
    @brianbelliveau5551 11 месяцев назад +1

    Didn’t know HF had solar panels they seem like they are pretty good and they have the connection for my zamp solar system in my keystone passport thanks for sharing

  • @JustSomeGuyNotAnAlien
    @JustSomeGuyNotAnAlien 2 года назад +1

    Thanks for making this quick and exact.

    • @johnnysweekends
      @johnnysweekends  2 года назад

      Thank you and thanks for watching 😀👍🏼

  • @nixieandyakyak3837
    @nixieandyakyak3837 2 года назад +6

    I’ve had numerous soldering classes in the USAF and after. They always say to start with a good mechanical connection, then solder. They both should crimp then solder.

    • @johnnysweekends
      @johnnysweekends  2 года назад

      Awesome thanks for the info. I have heard this as well and has always made sense to me..👍🏼

    • @michaeltichonuk2176
      @michaeltichonuk2176 2 года назад +1

      That is my thinking as well. Especially if application is mobile like RV and subject to vibration.
      Air Force Vet here too. We are such Perfectionists. Have to be!

    • @virt1one
      @virt1one 2 года назад

      Aluminum is usually crimped because it's more difficult to reliably solder to. Copper is usually soldered (except where mechanical stress is expected, because the point where the solder stops wicking into the copper wire forms a stress point and increases the chances of failure)

  • @kpadalldotablet1009
    @kpadalldotablet1009 Год назад +17

    As solder heats up and cools down, it will eventually crack. You can see that where VRMs, which get really hot, eventually fail at the solder joint. So crimping where they did isn't a bad thing at all.

    • @2pist
      @2pist Год назад +7

      I have yet to see a solder joint fail. I soldered wires under my vehicle 15 years and 100000 miles ago.

    • @kpadalldotablet1009
      @kpadalldotablet1009 Год назад +5

      @@2pist I just resoldred a 32 year old Bose bass module where the VRMs contacted the heatsink. About 80% of them had the telltale circular cracks in them. Wires probably will be fine. The problem is where the joint gets hot and cold over and over again.

    • @fgbhrl4907
      @fgbhrl4907 Год назад +6

      @@2pist By contrast, I had a '93 honda civic that developed a crack in a solder joint going to a relay on a PCB. The ambient temperature / engine temperature changes were enough to cause it to conduct or be open circuit. Took a while to find that....

    • @dorhocyn3
      @dorhocyn3 Год назад +1

      The more the indifferent the materials the more likely the solder is to crack and it depends on the type of solder. The Cummins 24 valve engines had issues with circuit boards losing contact internally from the heating and cooling with the Solder.

    • @steelman86
      @steelman86 Год назад +1

      So the best would be a crimped joint and then soldered it sounds like!! 6 of one, half dozen of the other!!

  • @Thatsmisteroldguytou
    @Thatsmisteroldguytou 2 года назад +1

    Very good. Info. Quick and easy to understand. No b.s. was appreciated.

    • @johnnysweekends
      @johnnysweekends  2 года назад

      You’re welcome and thanks for the feed back..😀👍🏼

  • @ruthdilbeck2035
    @ruthdilbeck2035 Год назад +1

    I was guessing from the beginning that this was a renogy commercial or something but this was quite fair and Harbor Freight coming out on top except in price. thank you.

  • @Tom-fu6sf
    @Tom-fu6sf 2 года назад +21

    Great comparison, but I wonder if the slight difference is because the Renogy ran a bit warmer, without air circulation behind it?. Keep up the good work.

    • @johnnysweekends
      @johnnysweekends  2 года назад +6

      I do t see how only a couple degrees could effect it. Even with me still comparing them just leaning on a wall the Hf is still consistently putting out more watts. It’s possible though.

    • @Tom-fu6sf
      @Tom-fu6sf 2 года назад +2

      Nice test, and good to see HF making progress,. But I got consistently over 100 watts at high noon with my Renogy panels when they were new.

    • @johnnysweekends
      @johnnysweekends  2 года назад +1

      What were the temps..?

  • @rgeraldalexander4278
    @rgeraldalexander4278 Год назад +3

    Cool to see the HF panel actually putting out 100 watts. Impressive.

    • @johnnysweekends
      @johnnysweekends  Год назад +1

      Where ever they got these from most are having very good results. And the little legs are a nice touch especially for a suit case set up.

    • @MikinessAnalog
      @MikinessAnalog Год назад +1

      @@johnnysweekends I assume now a final deciding factor would be size, shape, space +/-

    • @johnnysweekends
      @johnnysweekends  Год назад

      Yup, always try and get the biggest panels you can for the project and see what would fit best.

  • @RIPGLIDE
    @RIPGLIDE Год назад +1

    Very informative and straightforward. I appreciate that

    • @johnnysweekends
      @johnnysweekends  Год назад

      Your welcome .. and thanks for watching 😀👍🏼

  • @googleprivacyfilter8480
    @googleprivacyfilter8480 Год назад +1

    Appreciate your time on this comparison. I would like to see a device that showes illumination(light bulb) this would give a real time visual.

    • @johnnysweekends
      @johnnysweekends  Год назад

      I’ll try and find a charge test I can do so figure out a method to show some results but so many variables could make the test flawed

  • @jameslovrek8634
    @jameslovrek8634 2 года назад +24

    After working with electronics, off and on, through my life, I was surprised, recently, to find out that solder is a less than ideal conductor of electricity. That is why you rarely see it used in house wiring. It creates a point of resistance. The one thing with solar panels, though, is also the consideration that moisture may get into a crimped connection causing corrosion, causing resistance or failure.

    • @johnnysweekends
      @johnnysweekends  2 года назад +3

      Yea the nicest solar panels residential type are actually potted so you can even get to the connections which is fully water proof. Digging that out is no fun.

    • @Doing_it_right_the_first_time
      @Doing_it_right_the_first_time 2 года назад +5

      Like anything James, the quality of the solder is what makes or breaks a good connection and conductivity. Using a lesser grade / lower quality solder will of course impede current and voltage flow versus a higher quality solder and that is one with more tin in it.

    • @stefanl5183
      @stefanl5183 2 года назад +6

      Of course when you compare solder, which is mostly tin and lead to metals like copper and aluminum, it's a worse conductor, but the difference is small. And that's an apples and oranges comparison. It's an invalid comparison because the alternative to a solder joint is a junction between 2 separate pieces. As you mention you can get corrosion at junctions like that, but even without visible corrosion and without any moisture, practically all metals, except maybe gold and platnium react with air to form an oxide layer. In fact, this is the reason some metals, like Aluminum appear to not corrode. Aluminum appears to stay shiny, because it actually very quickly forms a very thin, hard layer of clear aluminum oxide that protects it from further corrosion. However, that oxide layer, will add resistance. So, a soldered joint is definitely going to be superior to any kind of crimped joint, unless you use gold plated contacts. The reason it's not used in house wiring is it would add cost and make repairs, modifications, or upgrades much more complicated and costly. Also, the actual thickness of the solder joint between the two contacts is going to be very thin, so even if the solder isn't as good a conductor as the copper, the overall difference is negligible and as stated is far superior to any other kind of junction. So, soldered is definitely the way to go.

    • @mikejohnson9118
      @mikejohnson9118 2 года назад +3

      you can improve that with dielectric grease and a heat shrink cover. By the time that fails, the panel is toast.

    • @garethbaus5471
      @garethbaus5471 Год назад +2

      Some high temperature silver solders can be almost as conductive as copper, but they are pretty much never used for electrical connections.

  • @Tael71
    @Tael71 Год назад +24

    I've found over time the Renogy panels hold up better than the harbor freight. My friends went with the harbor freight brand and I went with Renogy, in the beginning they edged me out but after a couple of years the Renogy have pulled ahead. They have mostly maintained their efficiency where as my friends HF have dropped quite a bit.

    • @johnnysweekends
      @johnnysweekends  Год назад +3

      Are they using these new thunderbolt mono panels ??
      Curious as I’ll do a 6 month and 1 year but even then 3 years seems to be the bigger test.

    • @MonkeySpecs301
      @MonkeySpecs301 Год назад

      Wow such a scientific review!!!!

    • @hundejahre
      @hundejahre Год назад +4

      Honestly, that sounds about right for anything HF. Not knocking them, to me their niche has always been less expensive products for things I won’t use a lot or am willing to risk losing.

    • @tomtee4442
      @tomtee4442 Год назад +1

      Harbor freight use to sell Lincoln Electric, Ingersoll Rand and some more name brands years ago.

    • @davidjames1063
      @davidjames1063 Год назад +1

      Zero maintence users versus not. You are trolling Renogy over H.F. in spite of obvious quality differences.

  • @nathanpotter8569
    @nathanpotter8569 Год назад +1

    Thank you for this video. Over the last few months, I've been collecting some harbor freight panels, and as I have been looking for things to connect with them I have seen these other panels show up on my feeds everywhere. I'm glad I don't feel burned. However, I did keep my connector that it came with and bought the 400-watt connector "pucks" to connect 4 panels together easier I guess, I just ordered some mc4 connectors and waiting for the ratchet crimpers to arrive. I did Just picked up 4 used 245 watt panels for $250 locally, so it will be interesting to see how much they put out in comparison to the 8 harbor freight ones I have.

    • @johnnysweekends
      @johnnysweekends  Год назад

      The used panels could do well depending how old and model. So yea would be interesting to see.
      And glad you liked the video…😀👍🏼

  • @cowboy7x
    @cowboy7x Год назад +1

    Great video. FAST and to the point.

    • @johnnysweekends
      @johnnysweekends  Год назад

      Thank you… and thanks for watching 😀👍🏼

  • @min2oly
    @min2oly Год назад +6

    Would love to see simultaneous reading with identical resistors as load. There is too much changing to actually compare. and ...
    watts IS amps x voltage!

  • @Londubh
    @Londubh 2 года назад +15

    One difference you didn't cite is the higher voltage for the HF panel; the same wattage at higher voltage will have less line loss, because line loss is largely a function of number of amps being pushed through

    • @frankswd
      @frankswd 2 года назад +5

      yep=i^2 * R

    • @scottkolaya2110
      @scottkolaya2110 2 года назад +2

      While true, they both have the same rating, just one of them isn't so honest.

    • @PeterTrimboli
      @PeterTrimboli 2 года назад +3

      I get what you're saying but a volt or 2 will give you negligible results the amount of resistance in the wire for 1 or 2 volts would probably result on fractions of a watt lost

    • @scottkolaya2110
      @scottkolaya2110 2 года назад +1

      We can discuss all the details of circuit resistance, half cell designs, etc. But given the fact, that the HF panel is 986 in² and the Renogy is 866 in² alone counts for an increase in output even if everything else was equal.

    • @Londubh
      @Londubh Год назад +1

      @@scottkolaya2110 you're assuming equal efficiency. The nominal specs of the Renogy is 18.6v 5.38A, while the HF is 18v 5.56A. Those are both 100.1W, despite the difference in size, meaning that _nominally_ the Renogy panel uses more efficient cells.

  • @snawsomes
    @snawsomes Год назад +1

    Bro, nice right to the point video. Keep it up man!

    • @johnnysweekends
      @johnnysweekends  Год назад

      Thank you and thanks for watching 👍🏼👊🏼😀

  • @ruizhou9612
    @ruizhou9612 Год назад +12

    I actually know one of the owners (a family member of Renogy) that was on site when they had their first startup in Chino Ca. She was really solid on quality and customer service. I watched this company grow, with Harbor Freight sometimes it is Hit or Miss.

    • @johnnysweekends
      @johnnysweekends  Год назад +2

      Renogy still has great products, but this HF panel did surprisingly well. Pretty impressed. Over time will it last and put out as much?? Who knows. I plan to do a one year test and just see what it looks like.

  • @actionjksn
    @actionjksn 2 года назад +8

    If I ever build a solar system, which I most likely will, I will find the best conducting wire I can. It will be crimped and soldered and it will be a full run without any connections from the roof to the first component. I suspect a thick gauge with fine strand copper would be best, but I don't know because I haven't researched that part yet. I will definitely be finding out.

    • @johnnysweekends
      @johnnysweekends  2 года назад

      You don’t want fine strand but medium will do fine. And depending on the run or how big 8 or 10g will be fine unless you plan on a larger home system then you’ll want to adjust accordingly.

    • @ferrofeles2063
      @ferrofeles2063 Год назад +1

      technically the best normal conductor of electricity is silver but running wire out of silver gets expensive fast

    • @Arby631
      @Arby631 Год назад +2

      @@ferrofeles2063 after buying 80ft of 2/3 copper cable I’d probably faint if I got a bill for silver lol

    • @mrmotofy
      @mrmotofy Год назад +2

      You're pretty much right on with your plan

    • @andrewt9204
      @andrewt9204 Год назад +1

      If you're worried about voltage drop, get an MPPT that can take 500V to get as many panels in series as you can. A single string at 8-9A won't have much drop at all even with a few connections in between the panels and MPPT. Tin coated copper is your best bet. It's more about retaining conductivity than starting out higher. And I wouldn't solder anything, a good hydraulic hex crimp with some dielectric grease will be just as good without adding brittleness that soldering brings.
      I used to solder wire connections until they starting breaking just below the solder points.

  • @arinasan247
    @arinasan247 2 года назад +1

    Great video, well thought out. Thank you!!!

  • @glenwaldrop8166
    @glenwaldrop8166 Год назад +1

    I would have lost that bet.
    I've had a couple of Renogy panels and I figured they'd win. Nice job.

    • @johnnysweekends
      @johnnysweekends  Год назад +1

      Thank you.!!! Will see what the 6 month and one year look like.😀👍🏼

  • @zachary4225
    @zachary4225 Год назад +5

    Man I’m glad I found this video. It covered all the questions I had. I have 4 of the harbor freight panels and I was wondering what the connector behind the panel looked like. And also today one panel was putting out 21.9 volts. While the other 3 panels were at 20.6. I thought something was wrong. But I guess it’s good to go.

    • @johnnysweekends
      @johnnysweekends  Год назад

      Nope numbers sound good and sometimes it’s just the angle of the panel. Be surprised if it’s off some it will effect it. But glad this helped you out 😀👍🏼👊🏼

    • @zachary4225
      @zachary4225 Год назад +1

      @@johnnysweekends thanks man. Really appreciated your video. I’m just trying to fine tune my mini system as I go along.

    • @johnnysweekends
      @johnnysweekends  Год назад +1

      Awesome everyone starts somewhere and watch out the big will get ya 😂👍🏼👊🏼

  • @MrNunna
    @MrNunna 2 года назад +50

    The Renogy crimped their wire connections because you can't solder aluminum wire. It would be better if they used copper wire in their units.

    • @suspiciousunicorn3085
      @suspiciousunicorn3085 2 года назад +7

      You certainly can solder aluminum wire, but it's impractical at this price point. Of course, Renogy is clearly aiming at a low price point here, with the "quantity over quality" mindset and they'd likely crimp connections anyway for the assembly savings. If they wanted, they could use copper-clad aluminum but there's nothing wrong with properly spec'd aluminum wire. Nor with crimping, if done correctly, and it would be mechanically more sound.
      The real issue is that it's a panel designed to stay at a $99 (now $89) price-point, and that means trimming every corner you can. Obviously a bit more gets you those trimmed corners back, but then it's not a $90 panel any more. The question is, does that extra $20-$40 get you 20-40% more performance. Is the performance difference from the Renogy due to crimped connectors and two feet of ~16awg (copper equivalent) wiring, or the cell assembly and quality? 14awg aluminum for 24v at 6A for 2 feet looks like more than is needed anyway.

    • @pierremitham2964
      @pierremitham2964 2 года назад +7

      It’s much more likely that the renogy panels are using tinned copper. No one uses aluminum wiring any longer. Crimps are a better connection than soldering for this application

    • @saltysteel3996
      @saltysteel3996 2 года назад +6

      IPC standards state a solder joint provides a better electrical connection than a crimp joint.
      Plus, the results speak for themselves. The HF panels are the clear winner and are built better.

    • @jonmccauley6490
      @jonmccauley6490 2 года назад +4

      @@saltysteel3996 I've had 2 Renogy's sitting on my camper for 2yrs now in the Texas sun with no issues.
      The HF is not the clear winner as it has a lower performance per dollar. That's the only scientific data that's been presented. The video review, including your opinion, is only speculating that the HF will last longer than the Renogy. You can't base a winner off pure speculation. Put these outdoors for 5yrs, compare performance and durability, and then you can deduce the winner.

    • @keatoncampbell820
      @keatoncampbell820 2 года назад +1

      @@jonmccauley6490 that does depend on use case, though. If I'm not mistaken unloaded solar cells in sunlight causes the silicon to degrade. So the quality of the silicon and the %load used from the panels will effect their lifespans as well. I'd think for something like a house with very good electrical management, the renegy is probably the best due to $/W and it being a best use case.

  • @robertalumbaugh5286
    @robertalumbaugh5286 2 года назад +1

    Great video comparison! Thank you

    • @johnnysweekends
      @johnnysweekends  2 года назад +1

      Thank you and thanks for watching 👍🏼😀

  • @jasonbroom7147
    @jasonbroom7147 Год назад +2

    I have four of the really old 25w panels from HF. They have been charging a small lead-acid battery and powering lights in our shed for at least 6 or 7 years, with no trouble at all.

    • @johnnysweekends
      @johnnysweekends  Год назад

      Yea those are the older ones. The amount of companies coming out with solar panels is really getting crazy…!! Glad to see them still working and thanks for the feedback..😀👍🏼

  • @ianide2480
    @ianide2480 Год назад +24

    One thing that you may want to look at before deciding anything about the material used in the wiring. You cannot call something copper or aluminum because of its color. There are copper plated aluminum wires and tin plated copper wires. Scrape the strands and see if anything else exists under a suspected plating before you decide what the wire is. =)

    • @johnnysweekends
      @johnnysweekends  Год назад +14

      I did update the description and comment section that it is tinned copper 👍🏼

    • @johnwalters80
      @johnwalters80 Год назад +3

      Great idea thx!

  • @8180634
    @8180634 Год назад +4

    At 2:47: crimps can be more durable than solder; solder joints can crack with time and vibration. Aluminum is not preferred however, aluminum oxides are not conductive so if the wire corrodes with age the joint can become bad. At 2:55 the diode solder joint in the middle looks less than ideal, notice how the solder is around the wire and not smoothly flowed to it, for lack of a better description. It looks like the joint wasn't heated enough during soldering, and/or they were skimpy on flux. Also for both cases using a pfet here instead of a diode would give better efficiency (less loss to heat).