  • @mubashiramir892
    @mubashiramir892 3 месяца назад

    Is there any standard for compaction .. how many time to strike the rod etc..?

  • @sahiransari3288
    @sahiransari3288 Год назад +1

    Cylinder mould hight and dia???

  • @engrmushtaq6061
    @engrmushtaq6061 2 года назад +1

    Great 👍 bro don't forget to explain how much will be the dia of temper rod and from how much height it should be free fall with fixed number of tempering.....the slump value is not fixed as should be varied as per concrete requirements

    • @CivilEngineerAtSite
      @CivilEngineerAtSite  2 года назад +1

      Yes dear I am try to share the things which are happening at site. Site is different from books. I am trying to give some snapshots form site to the fresh Engineers

  • @adnanabdul7044
    @adnanabdul7044 2 года назад +1

    If we don't get standard value then what we have to do
    Shall we cancel the concrete

    • @CivilEngineerAtSite
      @CivilEngineerAtSite  2 года назад

      If you watch the full video again you will get it. In the start the slump value was high then I wait for some time and take the concrete again for slump test and I get the correct value

    • @adnanabdul7044
      @adnanabdul7044 2 года назад +1

      @@CivilEngineerAtSite yes we got standard value if we didn't get then we should do
      If any another case if we didn't get standard value

    • @CivilEngineerAtSite
      @CivilEngineerAtSite  2 года назад +1

      The consultant will take the decision to reject or accept also depend on site conditions, projects conditions

    • @adnanabdul7044
      @adnanabdul7044 2 года назад +1

      @@CivilEngineerAtSite thank you

    • @thecivilsite
      @thecivilsite Год назад

      What should be slump values for slab ,beams and columns ?

  • @wasimahmed8170
    @wasimahmed8170 Год назад +1

    Sir,
    Please let me know that
    For how much quantity of concrete, how many samples of cylinder to be taken as per ACI
    Can you please Send me formate of ITP, NCR, MIR,

  • @Shahzad-EngineerBoy
    @Shahzad-EngineerBoy Год назад +1

    The first time you did the test, it failed, and then you observed for 15 minutes and after that the result was fine, but will the workers wait for 15 minutes? If the workers wated like this, time will be wasted "It is not better to change the water cement ratio

    • @CivilEngineerAtSite
      @CivilEngineerAtSite  Год назад +1

      Never change water cement ratio it will change the design of concrete. They have to wait

  • @ulsaffeek4863
    @ulsaffeek4863 Год назад +1

    Wrong slump test