What is Concrete Trial Mix| Quality Tests for Concrete| Air Content Test| Unit Weight Test.

Поделиться
HTML-код
  • Опубликовано: 17 ноя 2024

Комментарии • 58

  • @CivilEngineerAtSite
    @CivilEngineerAtSite  Год назад +6

    🚀The slump test (ASTM C143 / C143M) is used to measure the consistency of fresh concrete. It involves filling a mold with fresh concrete and then measuring the amount of slump, or settling, that occurs when the mold is removed. This test provides information about the workability of the concrete and can help ensure that it is easy to place and finish.
    🚀The air content test (ASTM C231 / C231M) is used to measure the amount of air trapped in fresh concrete. It involves filling a container with fresh concrete and then subjecting it to pressure to release any entrapped air. This test provides information about the durability of the concrete and can help ensure that it will withstand freeze-thaw cycles and other environmental factors.
    🚀The temperature test (ASTM C1064 / C1064M) is used to measure the temperature of fresh concrete. It involves inserting a thermometer into the fresh concrete and recording the temperature. This test provides information about the rate of hydration of the concrete and can help ensure that it will cure properly.
    🚀The unit weight test (ASTM C138 / C138M) is used to measure the density of fresh concrete. It involves filling a container with fresh concrete and then weighing it. This test provides information about the strength and durability of the concrete and can help ensure that it will meet the desired specifications.

    • @umarulfarooq216
      @umarulfarooq216 Год назад

      Sir is there is any vacancy in saudi arabia that we can apply from other country for freshers

  • @SabirAli-lo4em
    @SabirAli-lo4em Год назад +4

    Really appreciate your efforts,
    Will add 2 things
    1) Thermometer shall be placed at least 75 mm from edge of container or wheel borrow,ideally in centre of container
    2) As an engineer we can instruct technician to no handle concrete bare handed for due to safety purposes.

    • @mansoorbinashraf577
      @mansoorbinashraf577 Год назад

      May I know the Technical Reason why to place Thermometer 75mm from edge ? Any codebook reference ?

  • @muhammadawais-2798
    @muhammadawais-2798 Год назад +1

    Very impressive Engr saib

  • @pritheeshkumars7599
    @pritheeshkumars7599 Год назад +1

    This video very helpful for freshers sir 🎉tq so much sir🎉🎉

  • @Syediqbalshahh
    @Syediqbalshahh 8 месяцев назад +1

    Best of luck Eng Saif Shb

  • @engrkhalilnaz9019
    @engrkhalilnaz9019 Год назад +1

    Tnks sir for giving such a practical knowledge to us ❤

  • @engr.aftabahmad574
    @engr.aftabahmad574 Год назад +1

    well-done brother....we really appreciate.....thank you and all the best

  • @MuhammadIrfan-u8b9m
    @MuhammadIrfan-u8b9m 9 месяцев назад +1

    Sir Pls make one video for grouting

  • @langequerrolassinga8923
    @langequerrolassinga8923 11 месяцев назад +1

    Dear Mr SAif, I am a civil engineer and work as a CQC Engineer. Could you share any statements regarding honeycomb repair and concrete core holes with the application codes? That would be very helpful.

  • @engramjadalikhan7739
    @engramjadalikhan7739 11 месяцев назад +2

    First mistake: Temperature device must be kept in the center of the wheelbarrow, not on one side,

  • @Engineermudassardiaries
    @Engineermudassardiaries Год назад +1

    Good job !

  • @Junaidalam079
    @Junaidalam079 Год назад +1

    Your videos are so informative
    Please make videos on Aramco approval,sabic,shariq,
    petrokemya

  • @sadeeqahmad7559
    @sadeeqahmad7559 Год назад +1

    Good Job bro. 👍

  • @khajagazanfaroz3465
    @khajagazanfaroz3465 Год назад +1

    Keep the caption on sir

  • @langequerrolassinga8923
    @langequerrolassinga8923 11 месяцев назад +2

    how many minute you have to wait before the reading, after placing the thermometer?

  • @abdulmohsin6410
    @abdulmohsin6410 Год назад +1

    Sir kindly Explained about unit weight and Air Content test,

    • @CivilEngineerAtSite
      @CivilEngineerAtSite  Год назад +1

      🚀The slump test (ASTM C143 / C143M) is used to measure the consistency of fresh concrete. It involves filling a mold with fresh concrete and then measuring the amount of slump, or settling, that occurs when the mold is removed. This test provides information about the workability of the concrete and can help ensure that it is easy to place and finish.
      🚀The air content test (ASTM C231 / C231M) is used to measure the amount of air trapped in fresh concrete. It involves filling a container with fresh concrete and then subjecting it to pressure to release any entrapped air. This test provides information about the durability of the concrete and can help ensure that it will withstand freeze-thaw cycles and other environmental factors.
      🚀The temperature test (ASTM C1064 / C1064M) is used to measure the temperature of fresh concrete. It involves inserting a thermometer into the fresh concrete and recording the temperature. This test provides information about the rate of hydration of the concrete and can help ensure that it will cure properly.
      🚀The unit weight test (ASTM C138 / C138M) is used to measure the density of fresh concrete. It involves filling a container with fresh concrete and then weighing it. This test provides information about the strength and durability of the concrete and can help ensure that it will meet the desired specifications.

    • @abdulmohsin6410
      @abdulmohsin6410 Год назад

      @@CivilEngineerAtSite جزاک اللّہ حیر ،
      شکراً

    • @mansoorbinashraf577
      @mansoorbinashraf577 Год назад

      ​@@CivilEngineerAtSiteAppreciate it bro.
      Thanks for Sharing Knowledge

  • @abdulmohsin6410
    @abdulmohsin6410 Год назад +1

    JA ZA KALLAH khair

  • @HimanshuBarot-n6k
    @HimanshuBarot-n6k 5 месяцев назад +1

    Slump n air must be finish in 5 mins😊

  • @faridkhan-mf5xg
    @faridkhan-mf5xg Год назад +1

    Please make a vedio project quality plan

  • @Shahzad-EngineerBoy
    @Shahzad-EngineerBoy Год назад +1

    Sir Which standard codes use in KSA ?
    ASTM or ?

  • @mohammednaqeeb1949
    @mohammednaqeeb1949 Год назад

    Assalamualaikum.
    Will pls mention the standard value so it can be more clear..mentio in reply thank you

  • @EngrArif-it6mv
    @EngrArif-it6mv Год назад

    Acceptable Air content range ?

  • @maqsoodafridi4993
    @maqsoodafridi4993 Год назад +1

    Kindly bro name of air content or unit weight test instrument

  • @FaisalNazir-hf6ho
    @FaisalNazir-hf6ho Год назад +1

    Bro mera ek question hai, es ka answer must dena...
    Hum comcrete ka cube test karte hai for 7 days 14 days and 28 days, par wo concrete tu hum with 30 to 60min use karte hai. To cube test ka kya faida...??

    • @CivilEngineerAtSite
      @CivilEngineerAtSite  Год назад

      We have to check the strength of casted concrete by cubes or cylinders crushing.
      In case of cubes/cylinders failure we have to take cores from casted concrete at site and will crush that cores.

  • @adilzada2683
    @adilzada2683 Год назад +1

    Sir, Aamil aadi visa, Fardi visa and labour visa is same thing?

  • @kingkafeel
    @kingkafeel 2 месяца назад +1

    Hand gloves 🧤

  • @mohammedkhan543
    @mohammedkhan543 9 месяцев назад +1

    @CivilEngineerAtSite bhai how to get ACI certificate aur koie Institute rehta hai kya please bhai reply deyo im waiting for ur reply

  • @tahirusman1881
    @tahirusman1881 Год назад +1

    Dear Engineer,
    last week i interviewed for qc inspector position in Saudi Aramco, Therefore he asked me a question "what is the causal of Q " I do not know this question if you know the answered of this question please share with me

    • @CivilEngineerAtSite
      @CivilEngineerAtSite  Год назад

      Schedule Q is a document in which Aramco explain all the quality requirements for contractors

    • @muhammadarsalanmehsood5689
      @muhammadarsalanmehsood5689 Год назад

      ​@@CivilEngineerAtSitesalam sir g how are you I hope you are fine my name is arsalan Khan mehsood and I'm live in Pakistan I need your help can you help me

    • @zainulhassan7092
      @zainulhassan7092 10 месяцев назад

      Brother apne interview k liye apply kese Kia tha? Please explain

  • @adeeladi8706
    @adeeladi8706 Год назад +1

    Aslamualikum drawing k bary Mai batin kasin study karty hai

  • @innocentmian5266
    @innocentmian5266 Месяц назад +1

    Calculations

  • @salmanalikhan8128
    @salmanalikhan8128 Год назад +1

    Good but why not using gloves ?

  • @HimanshuBarot-n6k
    @HimanshuBarot-n6k 5 месяцев назад +1

    Naye hp kya

  • @AliHaider-li2op
    @AliHaider-li2op Год назад +1

    A.O.A
    brother i need your help, mje riyadh aye 4 month ho gay hen mje job ni mil rai mai civil Engineer hn pakistan 3 year ka experince be hai plz plz plz bro help me to find out a job plz

  • @wajidkazmi9805
    @wajidkazmi9805 Год назад +1

    Wrong precursor brother.

  • @owaismaqbool6969
    @owaismaqbool6969 4 месяца назад

    *This black shirt guy doesn't let others to learn or help*

  • @arsalankhan4545
    @arsalankhan4545 Год назад +1

    Assalamualaikum sir g stso number pkar de please

  • @abdulmohsin6410
    @abdulmohsin6410 Год назад +1

    JA ZA KALLAH khair