Zabardast tanveer Bhai Aap ki videos se bohat kuch seekhne ko mil Raha hai aur aap k naqshe qadam par chalte Howe mai bhi achi videos banane ki koshish kar Raha hoon. Thanks again dear ustade mohtarm
Dear Mr. Tanweer, i was eagerly Waiting for video on Ventilation system, i searched yesterday all your videos on your channel on this topic but didn't find so thought to write you to make video on Ventilation systems, it's so nice you already made. I request you to make more videos on this topics like you made on Fire fighting systems. Finally, thank you for your sharing knowledge on MEP Engineering.
Sir all your videos have been very very informative. Please let know if you can upload on plumbing system designing water supply and drainage riser and pipe size design also. This channel is a blessing indeed.
Calculation for the basement let's suppose we have dimension as mentioned below 20 x 20 x 3 = 1200 V x ach / 1.7 1200 × 18 ÷ 1.7 = 12705.8 cfm Is this calculation is correct If we have select the fan size for the basement based on above dimension and calculation is that our fan selection calculation is right .or no Is that fan capacity corrected 12705 is the capacity of the fan Need feedback on it from all engineers
Sir mere kuch questions the sir ji main puch raha tha ki hum jo jet and Axial fan basement main install karte wo kaise kiya jata h jaise ki basement main kitni CFM ka fan lagega ya kis arear Main kaise Nikalte h ki ek Axial fan kitne area ke liya lagya jata h aur ek jet fan kitna area cover karta h aur Axial fan ka cutout kaise nikalte h aur normal Axial fan 6000 to 40000 CFM ka fan koi sa bhi kitna area cover karta h please. Explain sir ek video ban do sir
Watch my this series of videos regarding basement car parking ventilation videos then mostly answers of your questions will find. If any confusion then ask question. Move forward step by step.
Ser ji ye ventilation ki duct design kitne velocity or kitne friction loss per karege aur grill and exhaust diffuser ko design krne k liye kitni velocity per lete h
Assalamualekum One of my project is going on Basement Ventilation. In this Project no CO sensor is their but CFD analysis is their how jet fans work with CFD analysis plz make a video. Hope you will support me.
Sir mera ek question hai ki agar basement me ham fresh air provide kar rahe hai suppose agar basement me fire lag jaye to us waqt hum agar fesh air intake karege basement me to fire increase kyuki oxygen level increase hoga fresh air ke zariye tab hum kya karege please tell me.
Assalamu alaikum bhai I'm in India bhaiya Mera basement main Koi roshandan nahin hai 100 Gaj ka hai uske andar ek gate bas gate ke upar exhaust fan lagaya hua hai but andar ghutan rahti hai fresh air nahin aati kya karna hoga bhaiya
Suppose we have basement 20 m by 20 m and height is 3 m Fan calculation or fan selection for the basement 20 × 20 × 3 = 1200 cubic meter 1m= 35.31 cft 1200 × 35.31 = 42,372 cft Q= vcft x ach / 60 Q= 42375 x 10 / 60 Q= 423,720/60 = 7,062 cfm = 7,062 / 2.119 = 3332.7 L/s The above mention calculation is as per civil defence UAE regulation I just request you kindly check and give your suggestions on this calculation. Thanks
Part-2: ruclips.net/video/Tds2O9yqLSw/видео.htmlsi=Ku3UP1ok4LulbyaX
masallah tanweer sir apne to zindagi raushan krde concept smjh gya pura sukriya.
Welcome
السلام علیکم ورحمۃاللہ وبرکاتہ جی کیسے ہیں آپ
ماشاءاللہ بہت اچھا کام ہے
Very good information sir Love you
وعلیکم سلام، الحمدللہ بلکل تھیک۔
آپ کی مھربانی
Gracias por el Video. Bien Explicado. Un Saludo desde Santo Domingo, República Dominicana.
Welcome
Zabardast tanveer Bhai
Aap ki videos se bohat kuch seekhne ko mil Raha hai aur aap k naqshe qadam par chalte Howe mai bhi achi videos banane ki koshish kar Raha hoon. Thanks again dear ustade mohtarm
Welcome
Dear Mr. Tanweer, i was eagerly Waiting for video on Ventilation system, i searched yesterday all your videos on your channel on this topic but didn't find so thought to write you to make video on Ventilation systems, it's so nice you already made.
I request you to make more videos on this topics like you made on Fire fighting systems.
Finally, thank you for your sharing knowledge on MEP Engineering.
Thanks for like my videos and appreciation
Useful information thank you Bhai from India 🇮🇳
Thank you
Assalamualaikum
Sir g
U r my super teacher
Welcome dear
Nicely explained in simple language
Thank you
Allah bless you tanveer sir
Thank you Farhan
Sir all your videos have been very very informative. Please let know if you can upload on plumbing system designing water supply and drainage riser and pipe size design also. This channel is a blessing indeed.
Ok I will work this subject also
very informative sir, thanks for sharing
Welcome
Calculation for the basement let's suppose we have dimension as mentioned below
20 x 20 x 3 = 1200
V x ach / 1.7
1200 × 18 ÷ 1.7 = 12705.8 cfm
Is this calculation is correct
If we have select the fan size for the basement based on above dimension and calculation is that our fan selection calculation is right .or no
Is that fan capacity corrected 12705 is the capacity of the fan
Need feedback on it from all engineers
Okay
Sir mere kuch questions the sir ji main puch raha tha ki hum jo jet and Axial fan basement main install karte wo kaise kiya jata h jaise ki basement main kitni CFM ka fan lagega ya kis arear Main kaise Nikalte h ki ek Axial fan kitne area ke liya lagya jata h aur ek jet fan kitna area cover karta h aur Axial fan ka cutout kaise nikalte h aur normal Axial fan 6000 to 40000 CFM ka fan koi sa bhi kitna area cover karta h please. Explain sir ek video ban do sir
Watch my this series of videos regarding basement car parking ventilation videos then mostly answers of your questions will find. If any confusion then ask question. Move forward step by step.
Ser ji ye ventilation ki duct design kitne velocity or kitne friction loss per karege aur grill and exhaust diffuser ko design krne k liye kitni velocity per lete h
Watch my duct designing videos
@@TanweerAhmed ser wo to dhek li wo sab samajh aa gaya bs wo plenum wali aur bana do pls
Assalamualekum
One of my project is going on Basement Ventilation. In this Project no CO sensor is their but CFD analysis is their how jet fans work with CFD analysis plz make a video. Hope you will support me.
Check my all video of car parking jet system.I hope, you will get the answer of your question
ماشاء اللہ
Allah dunya akhrat main kamyab krin
Thank you dear good comments. Allah bless you and all
Sir mera ek question hai ki agar basement me ham fresh air provide kar rahe hai suppose agar basement me fire lag jaye to us waqt hum agar fesh air intake karege basement me to fire increase kyuki oxygen level increase hoga fresh air ke zariye tab hum kya karege please tell me.
Watch complete video, I have brief
please reply sir
mujhe basememt me gym kholna he..or wha oxygen levels kam h toh wha kese ventilation system krna chiye
HVAC Design Consultant will resolve your problem
It's good sir
Thanks
Hi can put a video on how to calculate head of pumps. Both centrifuge pump & hydrnomatic pumps
Ok noted
Thanks
Welcome
Nice information
Thanks
Fire ke case me fresh air dena hai ya nahi.
Fresh air fan will not run in case of 🔥 fire
Good
Thanks
Assalamu alaikum bhai I'm in India bhaiya Mera basement main Koi roshandan nahin hai 100 Gaj ka hai uske andar ek gate bas gate ke upar exhaust fan lagaya hua hai but andar ghutan rahti hai fresh air nahin aati kya karna hoga bhaiya
Fresh air and exhaust air both shall be supplied for proper ventilation
Assalamualaikum
Sir can u explain thermal Store tank and decoupler line?
W.Salam, insha'Allah
Mashallah
Alhamdullah
Sir buldingme corridoe smoke extract fan hei
Same fans are used but application and design little different
@@TanweerAhmed wht different
Suppose we have basement 20 m by 20 m and height is 3 m
Fan calculation or fan selection for the basement
20 × 20 × 3 = 1200 cubic meter
1m= 35.31 cft
1200 × 35.31 = 42,372 cft
Q= vcft x ach / 60
Q= 42375 x 10 / 60
Q= 423,720/60 = 7,062 cfm
= 7,062 / 2.119 = 3332.7 L/s
The above mention calculation is as per civil defence UAE regulation I just request you kindly check and give your suggestions on this calculation.
Thanks
Ok
arigatougojaimasu tanweer san
?
@@TanweerAhmed means thank you very much tanweer sir in Japanese
ڀليڪار
Welcome in Sindhi
👌👌
Thanks
Dear sir air conditioning is ok
But what is ventilation sir send me link of ventilation
This is ventilation video
Sir good morning
Good morning ☀️
Thank you sir for information but can you put translate all videos to english thank you
Ok noted
how CO sensors locations defined?
CO sensor has sensing range in circle and as per area CO sensors quantities are fixed in columns or walls
Assalamualaikum sir
W.Salam
Sir g car parking main maf q lagty ha
maf?
Please share installation checklist and commissioning notes
Now not available and may be share later
@@TanweerAhmed this is my WhatsApp no 7278606729 text message if I have any questions I will ask you directly
Can you please send these pdfs
Sorry unavailable
Bhai mereko ek help ker saktiho. Urgent he
What type help is required?
@@TanweerAhmed need to talk with u???
Lv
Lv?
aapna number de do sir
Join my Telegram group