Dalawang Klase ng Outlet Installation | Alin mas Safe ? | Local Electrician
HTML-код
- Опубликовано: 15 сен 2024
- #outlet
#installation
#1gang
#2gang
#3gang
Thank you for watching guys!
Please visit our Channel👇👇👇
/ @localelectricianph
for more electrical installation and controls video tutorials.
FB Page: Electricians Guide
Direct message on our FB page for other questions. Thanks!!
OTHER USEFUL VIDEOS 👇
REMOTE CONTROL Switch Wiring | Testing
• Paano mg wire ng Digit...
MANUAL OFF AUTO MOTOR CONTROL
• MANUAL-OFF-AUTO Motor ...
FLOAT SWITCH wiring and diagram
• Float Switch wiring an...
3GANG SWITCH wiring
• 3 Gang Switch Wiring t...
HOW TO USE MEGGER / insulation tester
• HOW to use MEGGER Insu...
3-WAY SWITCH Wiring Tutorial
• 3 Way Switch - tagalog...
WYE DELTA MOTOR CONTROL
• WYE DELTA STARTER Wiri...
Stop Start Wiring Control Circuit and Diagram
• Stop Start Magnetic Co...
FORWARD REVERSE STEP BY STEP
• FORWARD REVERSE Motor ...
On Delay Timer Wiring Diagram
• ON Delay Timer Diagram...
FLOATLESS RELAY WIRING
• Floatless Relay Wiring...
Stop Start with Overload Relay Connection
• Magnetic Contactor Sto...
• Overload Relay ( therm...
OVERLOAD RELAY Function tutorials. tagalog
OHMS LAW
• OHMS LAW - Voltage Cur...
24 HOUR TIMER FUNCTIONS
• HOW TO SET 24 HOUR CLO...
• Multimeter Paano guma...
How to use MULTIMETER tagalog video
STOP START w/ INDICATOR LAMP
• STOP START w/ INDICATO...
• HOW TO SPLICE A WIRE -...
How to Splice a Wire video
MAGNETIC CONTACTOR PARTS AND FUNCTIONS
• Magnetic Contactor Par...
VOLTAGE TESTER
• VOLTAGE TESTER NEON SC...
HOW TO COMPUTE ELECTRIC BILL
• Electric Bill Computat...
7 WAYS TO REDUCE ELECTRIC BILL
• HOW TO LOWER ELECTRICI...
POWER FORMULA
• POWER CURRENT VOLTAGE ...
HOUSE WIRING TUTORIAL
• HOUSE WIRING TUTORIAL-...
PHOTOCELL with Magnetic Contactor
Wiring/Diagram-street lights
• PHOTOCELL w/ Magnetic ...
Magnetic Contactor VS Mechanical Relay
Uses and Function
• Magnetic Contactor VS ...
SUBMETER INSTALLATION
• SUBMETER INSTALLATION ...
MECHANICAL RELAY WIRING
• RELAY WIRING TUTORIAL ...
Music:
Tuff Data | Vans in Japan
No Copyright claim.
• Video
Vans in Japan | Four More Weeks
• Video
No Copyright Claim
Thank you sa iyong vlog. Kaya lamang sana hwag kami ang iyong pamiliin kung alin sa 2 paraan ang dapat gamitin para maiwasan
ang overloading sa linya. Malamang na higit na makakatulong ang iyong vlog kung sasabihin mo na rin agad ang dapat na piliin sa
2 paraan ng paglilinya ng outlets. Bagama’t ayon sa iyong paliwanag kung mabilis umunawa ang manonood ng vlog ay yaong
magkakahiwalay ang pagpasok ng linya sa outlets ang dapat na siyang gamiting paraan upang maiwasan ang sunog na dulot ng
faulty electrical wiring.
Meron po kasing mga electrician na yung gusto nila ang masunod lalo na pag wala alam ang client. Sasabihin nman ni client, "ba't yung materials sa iba mura " sa iyo mahal. depende po yan sa standards ng mga gamit. kya plagi po tayong manood sa mga vlogs para maunawaan po natin ang ibat ibang opinyon at diskarte ng mga technicians.Marami po tayong mapupulot sa kanila.. ❤️
@@edwinordinario2798 Salamat sa iyong paliwanag. Sorry, pero hindi ata tamang ang electrician ay susunod sa nagpapagawa kung ang huli ay mali dahil kapag nasunog ang bahay ng
nagpagawa dahil sa faulty-electrical wiring, and electrician na gumawa nito ay siyang masisi kung hindi man s’ya papanagutin sa pinsalang naidulot ng kanyang ginawa. Bukod dito,
kung naniniwala ka sa iyong kakayahan bilang electrician (na tingin ko naman ay experto kang electrician dahil meron kang sariling vlog) na pinakikinabangan ng marami mas maganda
cguro na manindigan ang iyong vlog kung ano ang pinakaligtas ayon sa iyong kaalaman at karanasan. Kung sabagay ang sa akin ay mungkahi lamang na sana ay mapagaralan mo kung
dapat o hindi mo dapat na gawin. Maraming salamat din sa pagbibigay mo sa akin ng iyong panahon. Ako ay nag subscribe na rin sa iyong vlog at umaasang maging matagumpay ka sa
iyong pagiging electrician vlogger.
Salamat po Sir. Well noted po. Base on actual experience lng po yong ibang sinasabi ko Sir. Pero hindi ko po kino kompromiso ang mga sariling gawa ko na magpapahamak sa akin at sa cliente ko po. Salamat po sa inputs at concern Sir😊
Salamat po Master
@@LocalElectricianPH idol bago lng ako chanel mu tanong sana ako, kng panu magtest na walang kuryente para malalaman kng ang linya mu? san mu ilalagay knob sa Tester ng digital?
Watching master sending full support..
Salamat master jo
Thanks sa sharing boss. Additional boss don sa nasa baba. Incase na masira or magka problem ang 1st outlet, lahat ng naka connect sa kanya affected. But don sa nasa taas once na magka problem ang 1st outlet hindi maapektuhan ang lahat ng outlet ns nasa dulo. For me yon yong isa sa mga iniiwasan ko bukod sa overload ng 1st outlet sa series connection pag nag iinstallation ako.
Salamat sa inputs Sir. Well noted po.
parallel connection is good..madaling itroubleshoot at hinde madamay ang ibang outlet..sakali masunog or loose connection sa terminal nya☺️
Salamat po Sir.
Nice sharing sir watching here sending full support
Salamat master..napindot kuna😊
May bagong natutunan nanamn ako😉...
Thank you po
Thanks for sharing idol...☺
Salamat dn.po
Nice sharing bro
Salamat bro.
Idol lagi ako nanonoud Ng mga video mo payakap naman po salamat idol
Salamat po..ge po
Now i know salamat sir
Salamat dn po sa pag view
At sa amp .dipindi sa isasak mo malalaman m sa watts.
ang galing mo lods..
Salamat po.
Ang parallel out po ay old code napo yan ang bago po ngayun ay nka pig tail po every outlet ang purpose po nun ay sakaling masira ang isa peron pang power ung iba…di tulab ng parallels pag sira isa lahat wang power ty
Salamat sa inputs Sir.
Mas safe ang nasa taas. nasunog yung nka series dahil mga chest type freezer ang naka connect sa outlet. Kya depende at ingat din sa mga isasaksak.
Opo sir. Safety first po palagai sa Electricidad
Idol .sana ginawa muna 2gang ..at yong amp.dna nasusunod lalo na pag maluwag ang plug iinit yan .
Yes po. Salamat sa inputs master.
Sir...subukan nyo na lng po tingnan...about
Radial circuit at Ring circuit..🙂🙂
Yes po..sa ibang bansa ganyan system nila😊
Boss bkit nyo Po binago Ang design Ng device wiring. At nag splice pa Ikaw.
Dagdag safety lang Sir specially for higher Amp loads
Naka istilasyon na boss ung bahay ko pero want ko magdagdag Ng 3 gang switch tanong Lang boss Kung saan koba pwede I tap ung connection Ng Hindi ako nagkakamali,, dahil parehong black ung wire na ginamit pano ko malalaman if saan ung line 1 line 2? Salamat po
F line to line supply nyo Sir. Pwedi naman yan magka baliktad...wag lng mg shorted po
nung kumidlat ng malakas sa amin, nacira ung nkacharge na celphone..at napondi ung isang ilaw..panu nangyari un sir?pumasuk ba ung kuryente ng kidlat sa wirings ng bahay?..may breaker naman ang kuryente namin..salamat sa sagot
Posible yun sir.meron kc voltage surge pag meron kidlat. Kaya advisable talaga unplug mga electronics natin pag meron kidlat
Good morning uli Sir.ilang outlet at ilaw Ang kaya Ng 20A na circuit breaker.
10pcs. na 2 gang po... sagad na yan at 180 watts limited load per outlet. Pero f lagpas sa 180 watts load nyo. Bawasan nyo nlng number of outlets
@@LocalElectricianPH salamat ulit Sir.God bless..
Welcome po
Sir tanong lng ung 12awg pwde ba sya Gawin cord Ng outlet extension?
Pwedi po
Salamat Po ggawa Kasi ko extension un Ang available wire ko sa bahay
Kuya paano I connect Ang breaker na Ang marking ay L1 at N pwede ba sa linya natin dito
Pwedi po..connect mo lang sa line 1 at line 2
Mas safe ang my individual connection sa bawat c.o.at mas reliable.
👍👍
D q type yang ganyan style. Madumi.
Dagdag safety po yan Sir
Sa code po ang 20 amps ay 10 outlet every 10ft
Salamat Sir
Salamat Sir
Don sa Outlet sa taas Po Sir ? Pwede kana din ba mag Add ng Lightning sir ??
meron kaseng mga ganun sir sa mga bahay,Isa lang breaker nila . Yung path ng Outlet nila ,iisa ng lightning nila
Pwedi naman po. Basta wag ka lalampas sa 16A total loads nyo po kasama outlets
3.5mm wire dn po gamitin nyo f mag dagdag kau ng ilaw
salamat sir
Sir pwedw po bang magdagdag o ipagtabi sa outlet ang installation sa taas?
Yes po 2 gang or 3 gang
Sir san nyu po natutunan ang ganyan..dito kc satin..ang ginagawa ay ung installation sa baba..
Sa mga engineers na kasama ko po.
Anong type yan na outlet
Flush type po
mas maganda po yung installation na nasa taas boss mas safe po yan
Yes Sir. Maraming salamat po sa panonood.