We have a 10KVA UPS of BPE make (2018). The batteries have been replaced recently 6 months ago. But the UPS is still displaying Battery low. What could be the reason?
Hlp me plz Kya ham 1kva online ups ko invertar se chala sakte hai 200 ah battry me 1225 va ka invertar se Power supply cut hone pe backup kitna der mile ga Pathology me lagana hai Cvt hai lekin flactuvation aa raha hai
Inverter ka output rating 1225 va hai. Online ups 1kva ka hai efficiency kitni hai utna power add hoga. .suppose efficiency 80%hai 20%loss hai toh 200va add hoga . Clearance ke liye 30% extra chahiye means 300va then inverter needed will be 1500va roughly. Or check full load on inverte .agar 800va ya close aata hai toh theek hai
@Total Power Solution Sir kisi ne 5kva online pcu bolkr de diya tha...aur 16 battery lgakr...solar panel voc 210-230 voc bnakr direct batteries par lga di ..fir bht battery kharab hoti thi..ab 16 battery ka controller bht costly h..16 battery ki series h ..sab battery change bhi nahin kr sakta..aap 48 ka bnado..fir mppt contrlr khareed lunga...possible?
hello bhaiya main Bangladesh se hoon aapka Ek subscriber Main Ek problem face kar raha hun yeh kya problem hai aur iska solution Kya Hai Jara bataenge please.
Sir I power 3kva online ups show battery voltage to high in display (133v)but manually battry voltage is normal(110v) ups not proper working. solution.
Aviprink thanks for video. Its very usefull video. I want to ask you one question if you answer me. I have numeric infinity ups. Its connected with 3 bettries(36vdc). So after 2 years one bettery is not working properly and i want to remove it. If i connect only 2 bettery(24vdc) and change parameter in ups mannualy(24vdc) then what effect on ups. Please suggest me. Company tell me purchase bettery.
It will be very difficult to change 36v UPS to 24 v . you need to remove many connections or need to replace parts trace parts. A simple mathod is to put a new battery innplace of defective one
01 Bus error showing in this UPS. Can you please tell what could be the problem output, charging ok. Rarely it works ok but often end up in error while in backup mode.
@@Aviprink the company is "elent" and the model is "UPS U03B" online ups 3000 VA 96 v SL NO 1411-0011 i found the model number written by hand on a small sticker in the cabinet
मेरे पास सेम डिजाइन आर एस पावर 3kva यूपीएस है। जिसका बैटरी 96 वोल्ट डीसी है। फॉल्ट यह है कि बैटरी 96 होने के बावजूद डिस्प्ले में 63 बोल्ट शो कर रहा है।
Hello sirji,Good knowledgeable videos, keep it up sir ji... Mujhe kuch doubts the ups related..can I have your whatsapp no.. please sirji.... Mujhe kuch madad mil.jayegi... Mera ups Eaton 10 kva ka hai aur fault code 89 bata raha hai...kaun se sections pe problem hai....Aur kya kya check karna padega iska... Kya aap iska..manual aur circuit diagram share kar sakte hain..please.. Awaiting for your kind response at the earliest.. Thanks..vvb
Hi Sir, thank you for this video. Do you have schematic for this ups ? Mine is quiet similar and had a weird issue ! As soon I tried to activate outpout, a big flash happens (pink like plasma) beetween 4 fast switching diode mounted on heatsink, but nothing burnt on the board, basic check of component doesn’t reveal something for now. I have a video of the issue here ruclips.net/user/shortscX2G8Nz-8s0?si=YkW1JBESxERxqJTQ Thank you for your advice
Good tiching karte hai 👍👌👍👍👌👌👍
We have a 10KVA UPS of BPE make (2018). The batteries have been replaced recently 6 months ago. But the UPS is still displaying Battery low. What could be the reason?
First you need to check that battery is charging properly with rated current then check for error..
Hlp me plz
Kya ham 1kva online ups ko invertar se chala sakte hai
200 ah battry me 1225 va ka invertar se
Power supply cut hone pe backup kitna der mile ga
Pathology me lagana hai
Cvt hai lekin flactuvation aa raha hai
Inverter ka output rating 1225 va hai. Online ups 1kva ka hai efficiency kitni hai utna power add hoga. .suppose efficiency 80%hai 20%loss hai toh 200va add hoga . Clearance ke liye 30% extra chahiye means 300va then inverter needed will be 1500va roughly. Or check full load on inverte .agar 800va ya close aata hai toh theek hai
Good tiching 👍👍👍👍👍👍👍👍👍
My office ups is BPE company of 1kva, it shows Overload problem without any output....what is the problem? and what I have to do???
Sir if one battery is fault need to replace all battery or only the particular battery
It would be better if entire battery bank replaced ..for balance
Input power card filtering ka cast kya rahega 3kva
Electric supply off hone par ups on Nahi Hota , kya ho Sakta , same model uniline 96v 3kv
🅰️🅱️🕉️🕉️GOOD TEACHING FOR YOUR CHANNEL🚦THANK YOU SO MUCH VERY VERY GOOD 👌👍👌👍💃💃💃😁😀😂😝😝
@Total Power Solution Sir kisi ne 5kva online pcu bolkr de diya tha...aur 16 battery lgakr...solar panel voc 210-230 voc bnakr direct batteries par lga di ..fir bht battery kharab hoti thi..ab 16 battery ka controller bht costly h..16 battery ki series h ..sab battery change bhi nahin kr sakta..aap 48 ka bnado..fir mppt contrlr khareed lunga...possible?
can u guide me to reapear 3kva ups model surt3000uxi apc ka hai
out put nhi de raha hai
batt sugn k upaf aur 1 sign hsi x ka whi dikha raha hai
Check it's manual
dear sir cyberpower ups on ho raha he lekin out put dc aa raha he koi error bhi nahi aata to kya problem ho sakti he
Output igbt check kijiye
Ser iske programing card apke pas mileage kya hame ek 24v ka online ups ka card chahiye
Mera ups continue beep sound de raha hai, MOSFETs,IGBT bhi thik hai
Error code hoga huch
Input power filtering card jhal gya hai.... Kya cost hogi..?
Online ups ka timer kese band kare aur ise inverter ki tarah use kare ise continue bina brekup me chalaen
Agar wo default hai then place tape on Buzzer
Sir same avo ups I have problem that I have given more load on output so now power button is not working.
Check it's fuse
Sir Ji Bpe 3 kva ups me 63 fault aa raha hai.use kaise thik Kare.ups ke kon se section me problem hoga.
same problum
Sir how are you,yiu teaching is intersting how can i solve bps phase error in 40kva ups
??
Sir I have a interest in ups service &repair will u teach me through online
Nice sir
very nice video sirji .
hello bhaiya main Bangladesh se hoon aapka Ek subscriber Main Ek problem face kar raha hun yeh kya problem hai aur iska solution Kya Hai Jara bataenge please.
Iske uper Maine jyada work ni kiya ha
Very nice sir thanks 👌👍
Is this 3phase? From where do you buy the card?
Sir
I power 3kva online ups show battery voltage to high in display (133v)but manually battry voltage is normal(110v) ups not proper working. solution.
You need to trace Resistor divider of Volt battery.. Try to check R Gnd
@@Aviprink hey. my 3kva inline ups is making blasting noise, solution please? i think its because of line noise issue
Sir mera pass yahii ups hai iska on.wala switch work hii nahii karta hai plzz vido send karoo
mera ups ka fault 01 show kar raha hain,to kya fault hain aur kya change kar na parega ap kya bata sakhta hain
I dont have fault data. Try google .
Sir prostar 2kva online ups.
Baar baar fan eror show kr rha kaise theek hogaaa
Fan check kijiye
Sir. How to contact with you... because i am industrial electrical incharge so 3ps this ups have damage in our industry
Brother, bus error 62 is coming. Tried most of the things, but no results. Company- Power Guard; model- HP3KVAS. Looking for your help.
Sir I have the same UPS but when charging the voltage is only 102V on DC side, what part should I check Thank you
Uske uper bhi video aaya hua hai charging CKT ko kaise check karna hai . ok
@@Aviprink Hey. Can you repair my ups too? Same model. It blast but no signs of damage anywhere in any PCB.
Sir what is problem battery fault .but we check battery fine fuse is fine
Aviprink thanks for video. Its very usefull video. I want to ask you one question if you answer me. I have numeric infinity ups. Its connected with 3 bettries(36vdc). So after 2 years one bettery is not working properly and i want to remove it. If i connect only 2 bettery(24vdc) and change parameter in ups mannualy(24vdc) then what effect on ups. Please suggest me. Company tell me purchase bettery.
It will be very difficult to change 36v UPS to 24 v . you need to remove many connections or need to replace parts trace parts.
A simple mathod is to put a new battery innplace of defective one
Very Nice
Sir Ye repair hone me kitni cost aayegi. Or shi ho jayega ya nhi
Sir 3kv ups mains on karne par falt2 bus over
Mere pass hai aur bilkul dead hai kya fault ho Sakta hai
sir hi 3kv 96v online ups without load 85watt load bata raha hai our 1hour baad output cut hojata hai
I think it is normal to show 85w (same here) put some load on output side then try it won't turn off it self
Bpe online ups mai 01 eror aa rha kya ho sakta hai
Hi, do you have the Riello MDT10 UPS service key?
Payment for that key to reset the battery service message.
Thank you.
96v 3kva uniline ups bUS ERR 62 and ups not on without ac power on
Sir good video
Sir 1 kva 36 V used online UPS mil jayega kya??
Mere paas 1kva 24v APC , smart ups hai. If needed call me at 8002381273
01 Bus error showing in this UPS. Can you please tell what could be the problem output, charging ok. Rarely it works ok but often end up in error while in backup mode.
I UPS Repair and services engineering anyone ups I interested your problem solve
Fan load ho kai display on nahi hota ky karu?
Critas ups mere ups me 450mf450v condenser. Fat gaye hai
Same model ups main on display work but No. power on and output
Change power button - check power button to logic board continuity and power button voltage. 5v ok
Mere pass bpe 3kva ka online ups hai wo charging toh ho raha hai pr on nahi ho raha hai any suggestion
Basics se start kijiye. Eg button. Continuity to main board.
Hello my 20kva elnova ups not start. I think its power card get burnt . input output process not done . i m using it on bypass what i do
If Any visible burnt mark found on main PCB then please check its associated parts of parts near burnt mark.
@@Aviprink ya its power card get burnt
2 kva online ups mein out nahi aa raha hai
Display mein ~ he sign bhi nahi ata
I think not detecting AC voltage.. 🤔
Dada aro video banayio Ups Full information
Thank you vai
Thanks for your tutorial..
Sar hamare UPS mein 21 error kyon a raha hai
Sir mere ups main fault 11 ho gya hai sir usko repair kaise kare plz sie btae
No idea bro . please check your ups manual .
problem hai Eco alarm a raha hai
D 809 ka valu pls ......96v charger board
Microtek 3 kva online ups battery galat lag gai ab ups on nahi ho raha display aa raha battery bhi charge ho rahi ky aho sakta hai
Fuse check kijiye
Bpe 2kva ka charging ko kaise check kare/thik kare
Inverter me sound aa raha on karne par kya kare
Battery charger Nahi sir usse converter or rectifier section bolate hai
Thank you
Hello sir my 1kva inverter won't starting it showing a 62 number in the display and long busser sound only what will be the reason
Thks in advance
Kindly include model no and compney
@@Aviprink the company is "elent" and the model is "UPS U03B" online ups
3000 VA
96 v
SL NO 1411-0011
i found the model number written by hand on a small sticker in the cabinet
यह स्क्रैप मार्केट कहां पर है सर सेकंड हैंड इनवर्टर कहां से मिलते हैं उसका एड्रेस डाल सकते हैं क्या सर
Sir..I can't find 2nd part for this video.. please help me to find it.
It will be available soon
Plz do quickly i got an ups of same config from scrap i want to repair it
@@Aviprink part second vedios kanha hai sir
is model main battery terminal pe shock marta hai to kya karen
Check parasitic capacitance
ups mu901hf error code 80 meaning?
मेरे पास सेम डिजाइन आर एस पावर 3kva यूपीएस है।
जिसका बैटरी 96 वोल्ट डीसी है।
फॉल्ट यह है कि बैटरी 96 होने के बावजूद डिस्प्ले में 63 बोल्ट शो कर रहा है।
Battery voltage me paas se ek sense trace hoga uske paas me koi resistor hoga usko check kijoye
Bhai is bale ki MCB trip ho hai
Sir i have Educomp UPS 24 volt pls pls tell me about change over fault for this ups thanx
Change over means when ups switches from battery mode to mains mode
Hello sir mujhe sikhna h apse please reply me
Btaiye
what brand that ups have?
E rickshaw smps charger ka dusraa part bhi banaao sir ji plz
Next video. Sure
Online UPS repair karna sikhana hai please meri help kijiye
sir help me
Nice video
Mera online Ups me "communication fails" dikhata he, kyu sir??
Control change
Sr mere ups me problem hai
Ser je scrap ups kahana milegaa
Ac output ni de Raha
Can I get this complete panal
You can contact me if you want to any ups products
my online ups ont turn on ...what is the problem
You need to check main supply first them . you need to ensure 5v dc in micrcontroller section
Fuse, 12v power supply board
Thanks sir
New board ki kimat kitni hogi
Sir online UPS scrap kaha pe milega
I contact me
Its not H bridge ,its sunber cct
Ok
Ups programin card kaha milega
Ups programming card kaha milega
Uske bare mein kuchh bataen sar please
Thanks good
بھاٸی اسکے ساتھ ہے ویڈیو بیھج رہا ہوں سلوشن بتاٸیں
Ups display not light no see
👍👌👍👍👌👍
I have 2nos 1 kva 36volt ups i want to sell
Hello sirji,Good knowledgeable videos, keep it up sir ji...
Mujhe kuch doubts the ups related..can I have your whatsapp no.. please sirji....
Mujhe kuch madad mil.jayegi...
Mera ups Eaton 10 kva ka hai aur fault code 89 bata raha hai...kaun se sections pe problem hai....Aur kya kya check karna padega iska...
Kya aap iska..manual aur circuit diagram share kar sakte hain..please..
Awaiting for your kind response at the earliest..
Thanks..vvb
nice
Super sr ji
How to bypass
Sayad control card defect
Sir apka contact no hai kya mere pass ek 6kva ka ups hai usme thoda problem hai
I UPS Repair, sell,PM,AMC, any model
Inu err aa rha h
Hi Sir, thank you for this video. Do you have schematic for this ups ? Mine is quiet similar and had a weird issue ! As soon I tried to activate outpout, a big flash happens (pink like plasma) beetween 4 fast switching diode mounted on heatsink, but nothing burnt on the board, basic check of component doesn’t reveal something for now. I have a video of the issue here ruclips.net/user/shortscX2G8Nz-8s0?si=YkW1JBESxERxqJTQ
Thank you for your advice
4 igbt he