Why U-bends are provided in Steam line? | What is Expansion loop? | U-bends function |

Поделиться
HTML-код
  • Опубликовано: 13 сен 2024
  • Hello friends,
    "Power plant discussion" welcome to all of you my friend to this channel, my name is chandan pathak, I have 10 years of experience in power plant operation field I have created this channel only for sharing knowledge about power plant operation and maintenance, for this I shall provide series of lecture on the various topic of power plant in which theoretical, practical and mathematical concepts are included.
    Email
    powerplantdiscussion@gmail.com
    Website
    / @powerplantdiscussion (Company Website)
    LinkedIn
    / power-plant-discussion...
    #PowerPlantDiscussion
    #ExpansionLoop
    Thanks to all of you for connecting me.

Комментарии • 148

  • @Samuel-yz1sm
    @Samuel-yz1sm 2 года назад +5

    I will try to watch at least one video daily ! Thank you sir ji

  • @shaikrahman2455
    @shaikrahman2455 2 года назад +4

    Superb explanation vicky kaushal ji

  • @asifcat
    @asifcat 2 года назад +3

    Sir aap ki videos bohat informative hoti hain 👍👍 ❤ from 🇵🇰

  • @chandanjana6964
    @chandanjana6964 2 года назад +5

    Jabardast questions.. 👌👌Thnx sir

  • @harshittrivedi8766
    @harshittrivedi8766 2 года назад +3

    Thank u for informative videos

  • @ameeranna5030
    @ameeranna5030 2 года назад +3

    Excellent sir ji super 🙏👍👌

  • @ashishvitekar3474
    @ashishvitekar3474 2 года назад +2

    Very good information and useful

  • @dashrathsinghyadav4059
    @dashrathsinghyadav4059 2 года назад +2

    The best knowledge

  • @ashokchavan539
    @ashokchavan539 2 года назад +2

    Thsnk you sir, very best daitals

  • @motamahesh1849
    @motamahesh1849 2 года назад +1

    Sir very useful video thanks...

  • @TrackYt
    @TrackYt 2 года назад +1

    Very informative video sir🌷 ...agr ye information 2month phle milti to mere case study me bohot kaam aati...jis company me study krne gye the vha unko boiler k bare me kuch pta ni tha.... Apne sab clear krdiya but late.... 🥰No prblm

  • @sarojnayak2480
    @sarojnayak2480 2 года назад +1

    intersting topic sir 🙏🙏🙏

  • @NilASH77
    @NilASH77 2 года назад +1

    Very unique topic

  • @md.hamidulislam8515
    @md.hamidulislam8515 2 года назад +2

    Helpful video sir

  • @neeleshverma4468
    @neeleshverma4468 2 года назад +2

    Thanks

  • @lonolysmoker6163
    @lonolysmoker6163 2 года назад +3

    Sir may Allah bless you.

  • @ashokawasthi2959
    @ashokawasthi2959 2 года назад +2

    Very good video sir

  • @DYEManavSharma
    @DYEManavSharma 5 месяцев назад

    Amazing video 😍😍🎉🎉

  • @yeshwanthkumar3567
    @yeshwanthkumar3567 Год назад

    Thank u for the video

  • @dt1449
    @dt1449 2 года назад +2

    Very nice..

  • @Omkarpawar9370
    @Omkarpawar9370 2 года назад +1

    So informative proud of sir

  • @sunilkumarsingh7151
    @sunilkumarsingh7151 2 года назад +4

    Sir what about those expansion loop which is horizontal not vertical.
    Why horizontal u bend is there?

  • @MuhammadZubair-dk8vx
    @MuhammadZubair-dk8vx 2 года назад +1

    Very nice. After a long i found a channel with good stuff

  • @bobythakur2922
    @bobythakur2922 2 года назад +2

    Good Explanation Sir..

  • @manjittiwari8042
    @manjittiwari8042 2 года назад +1

    Very good bhai

  • @suddhodash879
    @suddhodash879 Год назад

    U r just awesome... Very informative video.

  • @sonusavita58
    @sonusavita58 2 года назад +1

    Good explanation

  • @rajugoan1519
    @rajugoan1519 2 года назад +2

    Very nyc sir

  • @vedprakashratnani3129
    @vedprakashratnani3129 2 года назад +2

    Good

  • @AmitKumar-xf5tf
    @AmitKumar-xf5tf 2 года назад +2

    Nice video

  • @sreenivaskakani3620
    @sreenivaskakani3620 2 года назад +2

    Clear explanation sir..🙂🙂

  • @kumarhhhyyy
    @kumarhhhyyy 2 года назад +1

    Safety valve me seat ko Nozzle kahte hai
    Nice information 🙏

  • @bhojpurirahulvlogs3657
    @bhojpurirahulvlogs3657 2 года назад +2

    Nice Vdio

  • @nagarajnaik1788
    @nagarajnaik1788 2 года назад +40

    Kindly, avoid unnecessary lengthy explanation on very basics, for example in this video regarding metal expansion. If u drag unnecessarily purpose will loose it's sanctity.

  • @shailendrajadon3599
    @shailendrajadon3599 2 года назад +2

    Nice video sir....

  • @prmaisuriya2046
    @prmaisuriya2046 2 года назад +2

    👌👍

  • @HarishKumar-qg7fk
    @HarishKumar-qg7fk 2 года назад +2

    Nice sir

  • @raja5540
    @raja5540 Год назад

    nice

  • @kabitakumari8533
    @kabitakumari8533 2 года назад +2

    Boiler circulating pump par bhi video banaye

  • @Yeshuwithholisprit2466
    @Yeshuwithholisprit2466 Год назад

    Thank you sir

  • @aloneaaesh4045
    @aloneaaesh4045 2 года назад +1

    Thanks sir from 🇵🇰

  • @ranvirsingh5212
    @ranvirsingh5212 2 года назад +1

    Low pressure boiler me after prs station ke bad steam line me lga sakte hai kya sir

  • @Shiv4mv10
    @Shiv4mv10 2 года назад +6

    Please make a video on hydraulic couplings used in ID fan, BFP.

  • @deepaksharmaedits5275
    @deepaksharmaedits5275 2 года назад +1

    Sir once through boiler per bhi video banaye

  • @rajeshkumarorg
    @rajeshkumarorg Год назад

    Super sir

  • @rajnikanttandel8526
    @rajnikanttandel8526 2 года назад +2

    Hi sir steam strac work kese karta hai uspe video

  • @lokeshsharma7811
    @lokeshsharma7811 2 года назад +2

    Top support expansion se related kuch information video send kre

  • @trilokverma9810
    @trilokverma9810 2 года назад +2

    👍👍👍

  • @rajeshkushwaha7941
    @rajeshkushwaha7941 9 месяцев назад

    All the best sir

  • @ansharalam4763
    @ansharalam4763 Год назад

    Nice speech sir

  • @mehulpatel9828
    @mehulpatel9828 Год назад

    Good 👍

  • @abhishekmishra5445
    @abhishekmishra5445 Год назад

    Well explained 🙏

  • @muhammadtalha3163
    @muhammadtalha3163 2 года назад +3

    Sir kindly make a video on steam consumption of plant and its costing

  • @AnilKumar-xg1nq
    @AnilKumar-xg1nq 2 года назад +1

    Mughey boiler emergency heldling ka video chahiye

  • @vedprakashratnani3129
    @vedprakashratnani3129 2 года назад +1

    Sir. why Water hardness Shown in caco3

  • @buhimanshu
    @buhimanshu 2 года назад +5

    Sir, can you tell me please where I can install Differential pressure transmitter for measuring steam flow, how far it should be from condensate draining point???

    • @sanketmergu6654
      @sanketmergu6654 2 года назад +1

      It should be within 15M to turbine inlet flange.

  • @amazingworld5189
    @amazingworld5189 Год назад +1

    Turbine flow meter bhi bina power ke on hota hai

  • @RavindraYadav-pf7oo
    @RavindraYadav-pf7oo 2 года назад +1

    Please can you make vedio on oil fuel supercritical boiler process or flow daigram because I have seen in supercritical boiler have no steam drum so I want to know how to steam formation in supercritical boiler without steam drum?

  • @sumanhalder137
    @sumanhalder137 2 года назад +2

    Sir ji expansion loop apne yahan vertical dikhaye hai lekin bahut jagah horizontal rehta hai... Toh iss case me steam trap ka efficient functioning toh nahi hoga

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  2 года назад

      Dear jaise hi bend ke pass steam first apna direction change karta h, ohi pr steam trap lga dia jata h, Q ki steam aur water ka velocity me thoda difference rhta h, Ha ap bol skte h vertical ke case me bahut easily nikal jata h, usko ap ek dam boiler ke najdik hi lga skte h, ya kahi vi complicated way h oha lgaya jata h,

    • @sumanhalder137
      @sumanhalder137 2 года назад +1

      Thank u so much... Mera puchneka yehi purpose tha ki ye U bend steam line me only for EXPANSION ke liye diya jata hai... Kyuki steam trap ap koi bhi jagah jaha direction change hota hai waha de sakte hai...yaha loop banta hai isliye yaha trap diya jata hai... Anyway, I like your videos.. Bahut hi easy way me ap power plant engineering ko samjhate hai

  • @samirkumarsatapathy5324
    @samirkumarsatapathy5324 2 года назад +4

    Sir, aap ne alfa ka value 9-15*10^-6/Kelvin pe bataye. Aur ∆T ka value °C pe liye. Convert nahi kiye ( °C to °K )

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  2 года назад +3

      Dear this can be writing as /K, /°C, /°F
      If you convert T1&T2 in K, °C or °F then their difference is always same.

    • @shivendrasingh4822
      @shivendrasingh4822 2 года назад +4

      @@PowerPlantDiscussion difference is always same for C and K not for F because in F , 5/9 factor comes 🙂

  • @akshaythakur1760
    @akshaythakur1760 Год назад

    Rcf ki exam hai. Paper ki tayari ke liye questions ki video banav sir.

  • @silentmanqateri
    @silentmanqateri 2 года назад +1

    Cooling tower gear box Amrillo company checks ur gear ratio per video bnyia kindly

  • @Rahulthakur-sr2ww
    @Rahulthakur-sr2ww 2 года назад +2

    Sir, please make up a video on IBR rules...!

  • @krushnabisoyee2292
    @krushnabisoyee2292 2 года назад +2

    Make a video about Centrifuge working principle.

  • @nandanbisht6035
    @nandanbisht6035 Год назад

    Sir V1,V2=to P1,P2 par vedio banayiye.

  • @bsrinterestinggkquiz2569
    @bsrinterestinggkquiz2569 Год назад

    Dear ne afbc boiler which type of steam dry or saturated?
    Please

  • @JavedJaved-tf3rv
    @JavedJaved-tf3rv Год назад +1

    Sir , home load aur ideal ke upar video banao

  • @SkSamsuddin-xr3zc
    @SkSamsuddin-xr3zc 2 года назад +4

    Sir, in the example you say that thermal linear expansion value in Kelvin, and you took ∆T in deg. Celsius.
    Buy it's okay?
    We use it like this?
    Or we need to convert all value in Kelvin.

    • @SkSamsuddin-xr3zc
      @SkSamsuddin-xr3zc 2 года назад +2

      Okay, I am saying that the value of thermal liner expansion, that webconsiderb10, that is in kelvin.
      So for both case it would be same?@@tauqeerahmadsiddiqui2315

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  2 года назад +1

      Dear this can be writing as /K, /°C, /°F
      If you convert T1&T2 in K, °C or °F then their difference is always same.

    • @SkSamsuddin-xr3zc
      @SkSamsuddin-xr3zc 2 года назад

      @@PowerPlantDiscussion okay, I will do and check...thank you

  • @lipunkumar7168
    @lipunkumar7168 2 года назад +1

    Sir please explain about windbox 🙏

  • @amankumarshrivastava2380
    @amankumarshrivastava2380 2 года назад +3

    Sir, my yonger brother is machnical engg working in CHP area in refinary domain and wants to change material handling line.....
    Any course you can suggest?

  • @Ayush-qn8fe
    @Ayush-qn8fe 2 года назад +2

    Sir turbine mai load increase aur decrease ke upar video bnaye .

  • @neerajpokhriyal7958
    @neerajpokhriyal7958 2 года назад +2

    This is mainly for expansion
    Every metl has different linear cofficient of expension ..like ss and cs.. or apne kelvin ko celcius me change ku nhi kra?

  • @mohanraj-wk9ct
    @mohanraj-wk9ct 2 года назад +2

    Sir please make vedio like Aqc boiler (whrb) with preheater boiler

  • @bhargavaarvind
    @bhargavaarvind Год назад

    Why u beam in some place is upward or downward or horizontal

  • @miorfitri1511
    @miorfitri1511 2 года назад +1

    Add subtitle bro

  • @rachappapatil-vq1ei
    @rachappapatil-vq1ei Год назад

    Sir,
    Please make one video for BOE exam IMP questions and answers.

  • @rishavsingh5712
    @rishavsingh5712 2 года назад +2

    Some tym it's has horizontal arrangements why it like that

    • @Legioniznogoud
      @Legioniznogoud 2 года назад +2

      For compensating thermal strain in piping

  • @lipunkumar7168
    @lipunkumar7168 2 года назад +1

    Please sir 🙏

  • @maheshsaini5024
    @maheshsaini5024 Год назад

    Sir Why is bypass steam line provided in the boiler through the main steam line.?

  • @hareshprajapati8688
    @hareshprajapati8688 Год назад

    Is it same for super critical boiler also. .?

  • @satyasharma7754
    @satyasharma7754 Год назад

    Can u plz describe, why u bend proving in high pressure flare line?

  • @gauravjoshi1117
    @gauravjoshi1117 2 года назад +2

    Sir, What about /K

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  2 года назад

      Dear this can be writing as /K, /°C, /°F
      If you convert T1&T2 in K, °C or °F then their difference is always same.

  • @fitnessmuscleshorts9324
    @fitnessmuscleshorts9324 2 года назад +3

    Thank you so much sir.... But in my company the U bend is in horizontal way not in vertical... So it's same working or little bit different

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  2 года назад +3

      Same function but vertical is very effective to condensate removal, horizontal bend provided due to inconvenience in way,

  • @pdileep09
    @pdileep09 Месяц назад

    What is steam density at 200 degrees

  • @adityagod8939
    @adityagod8939 8 дней назад

    Sir celculeton samjh nhi ai kai bar dekhne par bhi

  • @narayankhandagale4500
    @narayankhandagale4500 2 года назад

    Moc of steam line

  • @asmuhammad2089
    @asmuhammad2089 2 года назад

    How much pressure drop in steam and water line bend please make a video please

  • @ravimathapati160
    @ravimathapati160 Год назад

    Difference between attemperator and Desuper heater(PRDS) one video PLEASE

  • @silentmanqateri
    @silentmanqateri Год назад

    explain expansion bellow types and why use in pipe line؟

  • @karmele7shree
    @karmele7shree Год назад

    nice video but alpha value is per kelin and u taken per degree centigrate so final ans will be changed.

  • @Mr.Engineer1255
    @Mr.Engineer1255 2 года назад +1

    thermal expansion value is in per Kelvin but temp dofference is in degree C ...so can we solve without conversion? What about it if we convert the unit from C to K?

    • @usamarasheed4349
      @usamarasheed4349 2 года назад +2

      Even if you convert “C” into “K” the temperature difference is going to be same. So i doesn’t matter if you take temperature difference in C or K or F they all are going to be same.

    • @Mr.Engineer1255
      @Mr.Engineer1255 2 года назад

      @@usamarasheed4349 oh,got it.

  • @devivara1162
    @devivara1162 Год назад

    Sir what r the reasons steam pipe line always protect with sheet plates?!

  • @deepakoraon9019
    @deepakoraon9019 2 года назад

    Alloy steel kaya hota hai bhai, steel to khud he alloy hai.

  • @narayankhandagale4500
    @narayankhandagale4500 2 года назад

    Steam line ki moc kya hoti hai

  • @devivara1162
    @devivara1162 Год назад

    Sir why steam density is less than water density explain????

  • @jigneshbhavsar2931
    @jigneshbhavsar2931 Год назад

    If thermal liner expansion is in K so is it required to convert C of Delta T in K or not?

  • @dk_pani
    @dk_pani 2 года назад +2

    Water Separator..

  • @rcyadaw87
    @rcyadaw87 2 года назад

    What if steam source to steam turbine length is less than 25 meter... Does expansion loop required or not?

  • @asifcat
    @asifcat 2 года назад +2

    Steam line main ye U band vertically ziyada behtar hain k horizontal?

  • @dipendramishra8625
    @dipendramishra8625 2 года назад +2

    Friction se condense nahi hota pipe ke cold internal surface ke contact me aake hota hai