DIFFERENT TYPES OF PLC MODULE| PLC में लगे सभी Module को details me समझे|PSU_CPU_SM_FM_IM_CP|Hindi|
HTML-код
- Опубликовано: 8 фев 2025
- Dosto Aaj ke video me dekhenge Different types of PLC Module ko details me i.e PSU(Power supply Unit), CPU(Central Processing Unit), SM(Signal Module),IM(Interface Module), CP(Communication Processor), FM(Functional Module) etc.
See the video till end for better concept.
Don't Forget to subscribe my channel 🙏
Note: If you have any questions regarding this then comment it in comment box.
Facebook page
/ industrialelengineering
E-mail I'd: asktonitinpal@gmail.com
Follow me on Instagram for Technical talk & Suggestions
/ nitinkr_singh
#plc
#differenttypesofplcmodule
#module
#typesofmodule
#typesofplcmodule
#powersupplymodule
#cpu
#cpumodule
#i_omodule
#analoginputmodule
#digitalinputmodule
#analogoutputmodule
#digitaloutputmodule
#modularplc
#plctypes
#differencebetweencompact_modularplc
#compactplc
#rackmountedplc
#fixedplc
#typesofplc
#compact_modularplc
#ai
#ao
#di
#do
#module
#modules
#industrialei_engineering
Very great video sir 👍 so nice
Very good sir
Very good beautiful nice job
Sir you done good job Nice explained 🤲🤲🙏🙏🖐️🖐️💐🌹🌹👌👌👌👋🤚✋✋🤝🤝🤝🤝🤝🙏
Excellent video
Very nice video explained....
Very good job sir
Nice
Thank you very much sir
Great job please carry on.
Nic sir
Thanks Sir 👍
plc system ko all instrument + vfd se connectivy ka vedio banaiye sir please
Very Nice
Make a video over sir profibus connection in plc
DCS pr videos bnaye
How to check digital feedback of any sunmersible pump. On scada the pump shows it start but actually it does not start. Then in this case what we have to do sir please explain
Sir, As per what you said ,
Feedback (DI) is not a problem,
the problem is your DO command from which Motor will start. When you start the Motor from your scada it is showing that DO comand is send to start the Motor but actually it doesn't start because
1.May be You wire connection is loose
2.May be your Connection is loose from yours PLC/DCS terminal block.
3.May respective relay is not operated in PLC.
@@IndustrialEIEngineering thank you sir.. please try to make small video on this and also on the troubleshooting of PLCS General problem.....you are doing great work sir... once again thank you
sir , RTI DO MO full form which will be help to understand
Good
How Are youuuuu but I hope you are Very Best and Very great 🙄👍
New types discussion please sir
Good morning sir
Esme two network alg alg h ya dono aaps me communication krte h kisi ak ke failure hone pe dusre PLC se communications ktta hai
Dcs pa ake video banaya sir
Jarur sir,
PLC ko bad DCS hi cover karenge.
Bane rahiye aap👍
@@IndustrialEIEngineering sr aapka mob nob chahiye
Different between S7 300 and S7 400 aur flofibus kyo use krte hai sir ethernet bhi to hota hai please
Difference between di and di soe modules?
Sir muje logic creation sikna hai kya aapki help mil sakti hai ?
👍🙄 hey everyone
Ok
Wireing and RTD ka configuration kese hota hai programming me dekhiye sir
Sir already videos available hai ,aap playlist me ja kr dekhiye
@@IndustrialEIEngineering ok thank you sir. currently I'm doing job as automation engineer (5th month experience). Your video contents very good it's help to improve my technical knowledge (I'm completed 3month industrial automation training)
Sir write in examination that a simple language theory
also we can see only input here in PLC no output ??
Rtd kya hai sir?
Plc ki programing sikhate ho kya
Ho much power supply in putt in PS
220v
थ्योरी के अलावा और कुछ नहीं है क्या आप के पास
Thank you sir ji..