Grounding and Bonding in the ham shack

Поделиться
HTML-код
  • Опубликовано: 6 янв 2025

Комментарии • 34

  • @johnm0csn
    @johnm0csn 2 года назад +5

    Gotta love these videos...no fancy schnazzle just a normal operator's shack shown how people want to see it 👍👍

  • @MrMesospheric
    @MrMesospheric 2 года назад +7

    I presume the yellow/green wire is your connection to an external earth rod. If so, and you have a PME domestic supply (very many in the UK do) but no heavy-duty (10mm2 minimum) connection from your earth rod to the consumer unit earth, then this is contrary to the electrical regs and could cause a fire in the event of a neutral break along the supply line. Not only is this bad, it could be ruinous, because the breach of regs may well mean your property insurance would be invalidated. This is a common and serious error and one that even the RSGB have made in print.

    • @g0fvt
      @g0fvt Год назад

      I totally agree, our supply is TN-CS to the house and this is a potential problem (no pun intended). There are workarounds where you can legally use a different scheme for an isolated room but with some stipulations. Unfortunately much of the advice on the internet is from the USA where physics works the same but wiring regulations are different. I suspect that many UK installations are wrong, and I must confess to not being above criticism...

  • @Tom_2E1FUE
    @Tom_2E1FUE 4 месяца назад +1

    Where did you get the copper braid from need some for my mobile antenna on my car? Thanks DE 2E1FUE

    • @hamradiostationg0dtx583
      @hamradiostationg0dtx583  4 месяца назад +1

      you can get them off eBay but I got mine off d X engineering hope this helps 73

    • @Tom_2E1FUE
      @Tom_2E1FUE 4 месяца назад

      @hamradiostationg0dtx583 Thank you for the information. I will try to get the 28mm one about 1m for the car. Thanks again, De 2E1FUE.

  • @butchdingle1000
    @butchdingle1000 6 месяцев назад +1

    Where did you get that buzz bar John will get one when I change coax for this M&P extraflex bury 10 stuff great video 73 DZH

    • @hamradiostationg0dtx583
      @hamradiostationg0dtx583  6 месяцев назад

      www.dxengineering.com/parts/ero-egba14210jf

    • @hamradiostationg0dtx583
      @hamradiostationg0dtx583  6 месяцев назад

      ERICO Copper Grounding Bars provide proper bonding; essential to create an equipotential plane between service grounds and shack equipment. This equipotential plane provides a near-zero voltage differential and serves to protect people and equipment during transient and electrical-fault events. These ERICO grounding bars have a series of 0.281 in. diameter holes that accommodate mounting many items, including Alpha Delta, PolyPhaser, and other surge-protection devices. They include stand-off mounts that deliver extreme isolation from the mounting surface. When used in tandem with ERICO ground rods and ERICO CADWELD ONE SHOT Wire to Ground Rod Clamps, there is no better grounding system available… period! These ground bars have a 1-1/16 in. standoff of their stainless mounting brackets plus a 1-1/2 in. insulator. This places the inside of the ground bar more than 2-1/2 inches from the mounting surface. There's plenty of room to work after mounting the bar. These bars may be mounted horizontally or vertically and the mounting holes in the copper bar are 8-7/8 in. on center. These grounding bars provide a convenient, reliable grounding location. Their quarter-inch thick solid-copper bar represents the ultimate in ground connections. ERICO grounding bars include insulators, stainless steel brackets, stainless steel mounting bolts, and are UL Listed. For premier grounding at your station, rely on ERICO Copper Grounding Bars from DX Engineering.

  • @128mark
    @128mark 29 дней назад

    nice set up , can inform me were you got the brass connectors that are on your earth braids and what size are they cheers . mark

    • @hamradiostationg0dtx583
      @hamradiostationg0dtx583  29 дней назад

      DX engineering ERICO Copper Grounding Bars EGBA14210JF DX Engineering Tinned Copper Braid Assemblies DXE-TCB10-RT03 hope this helps

  • @GateKommand
    @GateKommand 2 года назад +2

    Interesting and informative thanks mate.

  • @davidorme5579
    @davidorme5579 2 года назад +1

    great video again john

  • @superconductorchip
    @superconductorchip 2 года назад +5

    Plenty of ground loops, good if you want to cause interference..

  • @hamradiostation_M0UGE
    @hamradiostation_M0UGE 2 года назад +4

    Just a heads up...This seriously needs to be bonded back to the consumer unit if you're on a PME system...

    • @hamradiostationg0dtx583
      @hamradiostationg0dtx583  2 года назад

      Thanks for info

    • @hamradiostation_M0UGE
      @hamradiostation_M0UGE 2 года назад +1

      @@hamradiostationg0dtx583 Not trying to be "Mr Know it all" here,
      Ian (GM3SEK) gives some solid, sound advice on this topic at an RSGB convention, video link here - ruclips.net/video/LSL1h6MJbaI/видео.html
      73
      M0UGE

    • @hamradiostationg0dtx583
      @hamradiostationg0dtx583  2 года назад

      @@hamradiostation_M0UGE THANKS WILL HAVE A LOOK

  • @johngulliver6151
    @johngulliver6151 2 года назад +1

    Where did you get the braided earth strap I could do with some of that cheers great video thanks for posting

  • @robertbest6863
    @robertbest6863 Год назад

    Hi this is M1DAT Rob, was wandering were you got your braid and ring connector and how much. Look forward to hearing from you, many thanks.

  • @mauricewilkes826
    @mauricewilkes826 2 года назад +1

    Looks a bit overkill. How effective is rf grounding when your shack is on the first floor?

  • @johnratcliffe6438
    @johnratcliffe6438 Год назад +1

    I don't bother with grounding. My world hasnt ended.

  • @스피드-z6x
    @스피드-z6x Год назад +1

    OH good from HL5 call 73!!

  • @LAFD54
    @LAFD54 Год назад

    If you would use a balanced dipole antenna, you wouldn't need all those ridiculous magnets and straps!

    • @hamradiostationg0dtx583
      @hamradiostationg0dtx583  Год назад +1

      it's for noise coming from the neighbours not rf its for qrm on the coax.

    • @LAFD54
      @LAFD54 Год назад

      LOL! @@hamradiostationg0dtx583