Sir mere pass jo core hai uski beech wali patti 2.3 cm hai aur uski strack 6 cm hai .muze inverter ke liye 50 amp tak ka transformer banana hai uske liye wire gauge aur TPV bataiye . please please please reply me....thnxxxx..12 0 12 primary. And secondary 230 volt...
Sar Transformer Mein 7 Number Core , aur 6 inch ka Strike Ismein kitne kilowatt ka stabilizer banaa sakte hain Sir please reply , dena, Aur Sar ismein 100to480 V ka microcontroller kit Laga sakte hain
Sir please replay dijiye Sir aap ka jo bhi deta hai uske liye sirf power pack ka microcontroller bord lage ga ya phir koi bhi microcontroller bord chale ga
sir mere pas invrter transfomer ka winding data book hai usme data dikha hai 4 SQ inch/core 4no/st 2 sir mera samjh me ye nahi yaya ki agar 4 no core hai and st 2 inchi hai to 4SQ inchi kese hogaya helf sir
kya kisiko permission hai ki ghar me 22 kva ki power 200v supply me use karne ke liye, kyunki 90v×112A=10080vA aur 200v×112A=22400vA. Kyunki current to wohi rahega jab feeder wire se lekar house wiring wire me kuchh to badla nehin jata hai isliye.
My Dear 10 SWG wire will carry only 21 Amps current. 240v x 21 Amp = 5040 Watts means 5 kw load it can manage. For 10kw Load you need 7Gauge Wire which will carry 44 Amp current 240v X 44 Amps = 10560 watts means 10.5kw
current ke bare me koi nehin sochta hai. Jab input voltage 90v hoga tab input current 112A hoga pehla tappings ke liye. Jab input voltage 130v hoga tab input current 77A hoga dusra tappings ke liye. Jab input voltage 190v hoga tab input current 53A hoga 4 th tappings ke liye. Aur 3rd tapping ke liye current ratings 62A hoga aur 5th tappings ke liye current ratings 50A hoga. Aur core ki window area aur crossectional area ki products hi batayega kitna power ki transformer ho sakega.
Har bakt low output voltage se current ratings karne se thoda jyada current hota hai aur wire ki diameter bhi badhta hai jo sahi hota hai transformer me
Sir ji aap Automatic stabilize ke Data Bata te ho tu is ke Aap Relay connection ke saath mein Bata Koi bahi Automatic stabilize ke Data ho Relay connection aap Bata ya Karo sir ji Ta ke samjh mein AA ye Sab ko connection kar na nahi aata Aap please connection ke saath mein Bata ho.
Aap ko ye to malum hoga ki output me voltage 200 v se 240v tak ayega. To (240/200) =1.2. Aur (1.2×90) =108v.jab input 90v hoga tab output 200v ayega aur jab input badh kar 108 v hoga tab output badh kar 240v hoga.isliye input 1 no se Dena hoga aur output 5 no se Lena hoga. Iske baad me output relay on hoga aur input 109 se 130v ((1.2×109)=131v)tak 1 no me Dena hoga aur output 200 se 240 v 3 no se Lena hoga. Isliye 1 no tappings ka maximum voltage 130v hota hai. Jab aap 90v me karoge tab 1 no tappings 130v input hone se jal jayega.
Lots of thanks for 10 kv automatic v data n please continue till last, the kit, relay installation etc. etc. Please
Please send data 165 to up 1.5 ten aircundeshner steplizer
Sir mere pass jo core hai uski beech wali patti 2.3 cm hai aur uski strack 6 cm hai .muze inverter ke liye 50 amp tak ka transformer banana hai uske liye wire gauge aur TPV bataiye . please please please reply me....thnxxxx..12 0 12 primary. And secondary 230 volt...
Sar is transformer ko banane ke liye Kitna copper wire lagega❤
Very nicely you told thanks
Namaste namaste dhanyawad sir
सर जी 3फेस वोल्टेज स्टेपिलाइजर कैसे बनायें उस मे25के वी के लिए बायर व कोर के साइज भी बताएं और उस का वीडियो बनाकर डाले
Sir aap inverter ke transformar ko 12-0-12 banakar batao aur aapko kese pata hota hai ki kitne number ka taar lagaye
Kya hame har winding 138v.68v 40v.45v.9v. Gunah karna zaroori hai
Bhai ji core no 8B me strek kitna hoga
Thanks you sar ji
Toroidal transformer ke bare me bhi kuch batao sir
Sar Transformer Mein 7 Number Core
, aur 6 inch ka Strike
Ismein kitne kilowatt ka stabilizer banaa sakte hain
Sir please reply , dena,
Aur Sar ismein 100to480 V ka microcontroller kit Laga sakte hain
Sar kea apke pas microkontrollar kit hain 12v-0v
Sir ji 10 kva me kitna kilo E I patti lgega
Sir
Very nice
Sir almuniyam wire use karna hoga to kitna no ka wsg denge
Sir main west bangla sa bolre hai sir 8kv stbilizer uto reset ka data and cor and swg and tarn batya sir please?
Sath me ye bhi bataye ki kon sa microcontroller bord lagega module number ke sath
Ovesom, par sath hi ye bhi bataye ke
Kitne kva me kitni kg copper wire lagegi
Sir ye 90 se 280 ka he to kya ye srif single main hi chlega ya double main bhi chl skta he kyunki double main to 300 paar votage rhta he n
سر اگر ہم 20000 سٹپلائز بناتے ہے 28کلو بلاک میں تو اس کا فارمولا ہم کیسے نکالتے ہے بلاک کا ناف اور اس کا ٹرن اگر اپ اس پر بھی ایک ویڈیو بناؤ
प्रायमरी वाइंडिंग में कितने न.गेज ओर कितने न.टर्न डाले
Thanks for sharing ser how to get the size of wire what is the calculation see thanks....
Sir bobbin ka sayaj kaise nikale
Sir 90 to 440v automatic transformer mein loop kitna pe nikalenge sir please ek video banaye sir
Sir Kya Allumunium winding Kar sakte hai
Kw kam ho jayegi
Sir apko 7.5 kahase mila? 7.5 keya hai? Plz reply.
कोई भी स्टेपलाइजर के लिए वायर गेज किस प्रकार निकाला जाता है वायर गेज निकालने का फार्मूला क्या है
Ji sir iske bare me batayen please kindly zaroor se
Sir please replay dijiye
Sir aap ka jo bhi deta hai uske liye sirf power pack ka microcontroller bord lage ga ya phir koi bhi microcontroller bord chale ga
Koi bhei..
12kva manual stabilizer winding data
sir mere pas invrter transfomer ka winding data book hai usme data dikha hai 4 SQ inch/core 4no/st 2 sir mera samjh me ye nahi yaya ki agar 4 no core hai and st 2 inchi hai to 4SQ inchi kese hogaya helf sir
Copper swg 10 vayar ka vajan bataye
Sir namkar
Ek bat baitaye job turn counting Kar Te hai 0 se dosrah loop ke bad 0 se stat Karna hai ya continue Karna hai
Continue
Kaise pta hame 138volt ya 68 volt hai please
Gap bachta hai ya nahi aap bataoge na
Welding plant banane ka formula aur tarika batayen.
Sir humara yahan 10kw 8b core sa banta hai
Sir volt kese nikalte he Autometic ka ye bhi btaiye
kya kisiko permission hai ki ghar me 22 kva ki power 200v supply me use karne ke liye, kyunki 90v×112A=10080vA aur 200v×112A=22400vA. Kyunki current to wohi rahega jab feeder wire se lekar house wiring wire me kuchh to badla nehin jata hai isliye.
sir isme primary winding to h hi nhi wo isi me se nikallege kya bta dijiye plzzzz
Isme 0 se 138v wali loop tak trimary winding hei...
My Dear 10 SWG wire will carry only 21 Amps current.
240v x 21 Amp = 5040 Watts means 5 kw load it can manage.
For 10kw Load you need 7Gauge Wire which will carry 44 Amp current
240v X 44 Amps = 10560 watts means 10.5kw
current ke bare me koi nehin sochta hai. Jab input voltage 90v hoga tab input current 112A hoga pehla tappings ke liye. Jab input voltage 130v hoga tab input current 77A hoga dusra tappings ke liye. Jab input voltage 190v hoga tab input current 53A hoga 4 th tappings ke liye. Aur 3rd tapping ke liye current ratings 62A hoga aur 5th tappings ke liye current ratings 50A hoga. Aur core ki window area aur crossectional area ki products hi batayega kitna power ki transformer ho sakega.
Har bakt low output voltage se current ratings karne se thoda jyada current hota hai aur wire ki diameter bhi badhta hai jo sahi hota hai transformer me
Sir aap 15,or 20 kva ka bhi data bata na jo ham dj me use karseke.
Sir ji 3 kva automatic stebilizer 50 volt to 230 volt ka data bateye
440v se5kva stablizer ko banana hain
7 KB ka stabilizer 140 se hai abuse 90 mein banvana hai kya Ban jaega
Please send data 165 up 1.5 ten aircundeshner
Sir
manual stabilizer data di ge a
10kw,kaa,manul,steplaezer,kaa,yanding,data
Sir iska wire weaght kitana hoga
Wire weaght
Sir
Comments ka jababa bhi diya kijiye
90v to 340v stpz ka data 3kw ke ley 7no core me
Sir need 230 v ac 24,15 v 120 A transformer data
Sir ji aap Automatic stabilize ke Data Bata te ho tu is ke Aap Relay connection ke saath mein Bata
Koi bahi Automatic stabilize ke Data ho
Relay connection aap Bata ya Karo sir ji
Ta ke samjh mein AA ye
Sab ko connection kar na nahi aata
Aap please connection ke saath mein Bata ho.
Sir jb 90volt se 280 volt bana rhe hai to 90 volt ke jagha 138 volt kyo rkhe hai
Aap ko ye to malum hoga ki output me voltage 200 v se 240v tak ayega. To (240/200) =1.2. Aur (1.2×90) =108v.jab input 90v hoga tab output 200v ayega aur jab input badh kar 108 v hoga tab output badh kar 240v hoga.isliye input 1 no se Dena hoga aur output 5 no se Lena hoga. Iske baad me output relay on hoga aur input 109 se 130v ((1.2×109)=131v)tak 1 no me Dena hoga aur output 200 se 240 v 3 no se Lena hoga. Isliye 1 no tappings ka maximum voltage 130v hota hai. Jab aap 90v me karoge tab 1 no tappings 130v input hone se jal jayega.
Sar 1000 kw Manuel deta bataye sar video Baker bheje sar
Kabhi BHI 10 KVA Nahi hai, 90 to 280 ke liye 9swg Chahiye
Sir ismea CK 100 kit ore Neuton kompani ki. Kit isteamaLkarnea sea stabilizer Kam kareaga please please sir massage vage
Yes
Bang !@ wrong swg size
According to load of 10 kw 🤩
140v se 500v ka data de sir
70 to 230
I think 10 kva ka stabilizer banega 10 swg me jo ki 8000 watt hoga
agr 10000 watt banana hai to 9swg use karni chahiye ....
मेरे पास 50 एमएम बाय 65 एमएम एक्सट्रैक्ट रखा हुआ है मैं उसको वेल्डिंग ट्रांसफार्मर बनाना चाहता हूं कृपया जानकारी दें 9752 7750 45
Pleases gide me
Hello sir ji , good evening ji , sir ji driver transformer and sound transformer ka data chahiye , plz your whatsapp no. Ji
Ovesom, par sath hi ye bhi bataye ke
Kitne kva me kitni kg copper wire lagegi