CSI SAFE - 22 Strap Foundation

Поделиться
HTML-код
  • Опубликовано: 8 сен 2024
  • A strap footing is a component of a building's foundation. It is a type of combined footing, consisting of two or more column footings connected by a concrete beam.
    A strap footing is often used in conjunction with columns that are located along a building’s property or lot line. Typically, columns are centered on column footings, but in conditions where columns are located directly adjacent to the property line, the column footings may be offset so that they do not encroach onto the adjacent property. This results in an eccentric load on a portion of the footing, causing it to tilt to one side. The strap beam restrains the tendency of the footing to overturn by connecting it to nearby footings.
    ********************************************************************
    To Build a relationship, Please CLICK THE SUBSCRIBE BUTTON..
    1-Download CSI SAFE Software Latest Version
    civilmdc.com/c...
    2-PASSWORD
    www.civilmdc.com
    If you face any difficulty...... Please Feel free to contact.
    Contact Details
    www.civilmdc.com
    Professional Trainers
    Email ID: civilmdcgroup@gmail.com
    #Srap #foundation #SAFE

Комментарии • 55

  • @civilmdc
    @civilmdc  5 лет назад +3

    To make a RELATIONSHIP, Don't forget to press the subscribe button with bell icon to get the latest notifications. My channel :)
    ruclips.net/channel/UCw9kSuR1bTFBmaMEyD_DXvQ

  • @manik.c834
    @manik.c834 11 месяцев назад

    Excellent... expecting more videos . Thank you engineer .

    • @civilmdc
      @civilmdc  11 месяцев назад

      Welcome
      Here is the full course link on CSI SAFE
      ruclips.net/p/PL0h14oMuZXQ6l-O7aqF0hYsZbyJ7eFt1H

  • @BashirAhmed-jo4zq
    @BashirAhmed-jo4zq 3 года назад

    Really Appreciate your Series of videos on different softwares. Nice job dear

  • @erimoro3
    @erimoro3 5 лет назад +1

    Excelente video, explicacion muy clara, gracias ingeniero

  • @dennysnjagy9134
    @dennysnjagy9134 2 года назад

    Amazing. Tuned in from Kenya

  • @SantiagoGomez-ih6rg
    @SantiagoGomez-ih6rg 3 года назад +1

    Thank you. I wonder if it´s wrong to include a linear subgrade modulus in the beams in edge column case.

  • @Dr_Mike_US
    @Dr_Mike_US 5 лет назад +1

    Thank you, Bro!

  • @Johnny-pz3ch
    @Johnny-pz3ch 3 года назад

    Thank you kind sir!

  • @awasay5
    @awasay5 4 года назад +1

    I appreciate your efforts...But I want to clarify one big doubt ....As per the codes it is recommended to provided only one layer i.e bottom layer of reinforcement ...Experts say that the upper layer of reinforcement don't contribute in further increasing flexural capacity ...Also considering the economical side ...I just want to provide the reinforcement as bottom mesh for the eccentric or edge footing ...Could you please suggest how to deal with this situation .......

  • @asangajurel8558
    @asangajurel8558 4 года назад +1

    If we don't check the punching, how do we determine the depth of footing? Can you please elaborate??

  • @engayedalayed7004
    @engayedalayed7004 4 года назад +2

    PLS MAY I GET CLARIFICATION ABOUT K SPRING COMPUTATION. BECAUSE WE USUALLY COMPUTE IT BY THIS FORMULA ( ALLOWABLE B.C*120 -AS SI UNITS )
    EX: IF ALLOWABLE BC =200KN/M3 THE K =200*120=24000 KN/M3) IS THIS PROCEDURE CORRECT OR NO

    • @civilmdc
      @civilmdc  4 года назад +1

      I got your question.... That is also one method...
      Here is the full course link on CSI SAFE
      ruclips.net/p/PL0h14oMuZXQ6l-O7aqF0hYsZbyJ7eFt1H
      and here is the lecture, where i have discussed about both method... Basic and Bowl's Approach method
      Link: ruclips.net/video/NDfeQt8x4VY/видео.html

  • @engr.md.titumirhasan5595
    @engr.md.titumirhasan5595 4 года назад

    Sir, In foundation design why consider only service load combination not ultimate factored load combination. in load combination what should check using ultimate load combination. From Etabs should we take only dead and live load why not seismic load effect. pls sir.

  • @markcanicula
    @markcanicula 4 года назад +1

    what if it the column is eccentic on both x and y direction i mean the column is on the corner edge of the property line. is it possible to design the whole perimeter strap beam due to the lot is small and need all column to be on the edge of property line. thanks

    • @civilmdc
      @civilmdc  4 года назад

      Yes it is possible

  • @allinfo321
    @allinfo321 5 лет назад +1

    When I check Punching Shear it says "N/C" not calculated. Please help

    • @civilmdc
      @civilmdc  5 лет назад +3

      Software will never calculate punching shear for strap foundation (A foundation connected with beam).
      Because beam will restrict the punching... it will restrict the punching of foundation......
      For Example: If you have slab and columns only (Means with no beam), then there is a chance of punching shear,...........
      But if you have slab with beams and columns... there is almost no chance of punching.
      I hope this will clear your question.

  • @surajgurung5856
    @surajgurung5856 4 года назад +1

    While Applying the column load, Should we use factored load or unfactored load?? help plz.

    • @civilmdc
      @civilmdc  4 года назад

      Unfactored loads.....
      And bearing pressure... Use Allowable bearing pressure

    • @surajgurung5856
      @surajgurung5856 4 года назад

      @@civilmdc while in manual calculation of raft foudation, stress on soil, sigma (6)= P/A + Mx/Iy + My/Iy, which load should we use, P, Mx, My factored or unfactored???? plz help

  • @Dr_Mike_US
    @Dr_Mike_US 5 лет назад +1

    Bro! You're from which country (If you don't mind)?

    • @civilmdc
      @civilmdc  5 лет назад +1

      No issue... from Pakistan

    • @Dr_Mike_US
      @Dr_Mike_US 5 лет назад

      @@civilmdc am also from Pak...Thanks anyways...Bro

  • @md.ashrafulalam4732
    @md.ashrafulalam4732 4 года назад +1

    How can i design these kind of footing in safe if i done the analysis of the building in etabs?

    • @civilmdc
      @civilmdc  4 года назад +2

      Here is the full course link on CSI SAFE
      ruclips.net/p/PL0h14oMuZXQ6l-O7aqF0hYsZbyJ7eFt1H

    • @md.ashrafulalam4732
      @md.ashrafulalam4732 4 года назад

      @@civilmdc Thanks

    • @md.ashrafulalam4732
      @md.ashrafulalam4732 4 года назад +1

      One thing, i have done analysis and design of a 6 storied building in etabs. Now i have to design foundation. So how can i design the foundation of the building in SAFE from ETABS file that's i wanted to know. I have seen the playlist you shared and i don't understand which one is needed me. I am in shorting time. It will be very helpful if you please specify the link of the tutorial.

    • @civilmdc
      @civilmdc  4 года назад +1

      @@md.ashrafulalam4732 CSI SAFE 20 AND 21 Lecture

    • @md.ashrafulalam4732
      @md.ashrafulalam4732 4 года назад

      @@civilmdc May Allah bless you.

  • @roshansharma1655
    @roshansharma1655 5 лет назад +1

    why have the punching shear design not checked needed some clue??

    • @civilmdc
      @civilmdc  5 лет назад

      I have watched the video again.
      I forgot to check the punching shear check...
      It is simple to check shear check..... And you have to Must check the punching shear check....
      For that.. Go to display and select.. Punching Shear check...
      You will see the details of punching shear check.

    • @civilmdc
      @civilmdc  5 лет назад

      I have watched the video again.
      I forgot to check the punching shear check...
      It is simple to check shear check..... And you have to Must check the punching shear check....
      For that.. Go to display and select.. Punching Shear check...
      You will see the details of punching shear check.
      If you still face any issue please let me know

    • @roshansharma1655
      @roshansharma1655 5 лет назад

      @@civilmdc can i get to know if the N/C comes after checking the punching shear. Even after changing the footing thickness the punching shear did not come less than 1.
      how can we make it less than 1 .
      any suggestion or further video would be fruitful for all the viewers.

    • @fadifadi-ug5cp
      @fadifadi-ug5cp 5 лет назад

      @@roshansharma1655 n/c means punching shear is not calculated because beams prevent slabs from punching.

  • @shaheershafat4599
    @shaheershafat4599 2 года назад

    What about shear reinforcement in beam.

    • @civilmdc
      @civilmdc  2 года назад

      You can also check.

    • @shaheershafat4599
      @shaheershafat4599 2 года назад

      @@civilmdc where ?? Pls help

    • @civilmdc
      @civilmdc  2 года назад

      @@shaheershafat4599 display, go to show beam design...

    • @shaheershafat4599
      @shaheershafat4599 2 года назад

      @@civilmdc Display type to transverse rebar?

    • @civilmdc
      @civilmdc  2 года назад +1

      @@shaheershafat4599 Yes

  • @borhan-ulhasan7965
    @borhan-ulhasan7965 5 лет назад +1

    Dear friend please share Pilecap design. Thank you

    • @civilmdc
      @civilmdc  5 лет назад

      Sure I will share pile cap design in CSI SAFE.

    • @civilmdc
      @civilmdc  5 лет назад

      @
      Borhan-ul hasan CSI SAFE - 23 Pile Cap design Link ruclips.net/video/imznVQh5QXQ/видео.html

    • @civilmdc
      @civilmdc  5 лет назад

      I have uploaded the pile cap design video.

    • @borhan-ulhasan7965
      @borhan-ulhasan7965 5 лет назад

      @@civilmdc Thank you brother.May ALLAH bless you .

    • @civilmdc
      @civilmdc  5 лет назад

      @@borhan-ulhasan7965 Ameen... You too.