Thermal-Stress Analysis using Hypermesh [Optistruct Tutorial]

Поделиться
HTML-код
  • Опубликовано: 22 авг 2024
  • In this Optistruct tutorial, we will perform a coupled thermal-stress analysis using Hypermesh. Thermal loading will be applied on an IC engine block and resultant stress results due to thermal expansion will be visualized during post-processing.
    CAD Model Link : drive.google.c...
    Recommended Videos :-
    Non-linear Analysis using Hypermesh : • Hypermesh Nonlinear An...
    Topology Optimization using Optistruct : • Topology Optimization ...
    Dynamic Crash Analysis using LS Dyna : • Dynamic Crash Analysis... #aeroswap #fea #hypermesh #cae

Комментарии • 58

  • @yeene04
    @yeene04 7 месяцев назад +1

    This guy is incrediable! He knows everything

  • @manas3657
    @manas3657 3 года назад +2

    This is the first video I am watching but its possibly the best video on internet for thermal stress analysis right now thank a lot man this
    helped me

    • @Aeroswap
      @Aeroswap  3 года назад

      Glad it was helpful :)

  • @GnrlZBenZ
    @GnrlZBenZ 2 года назад

    U iz real FEA mate, bro ! CongratulationZ from tha old skool ! :)

  • @emmanuelvassilakis5630
    @emmanuelvassilakis5630 3 года назад +1

    Nice Swapnil! As a suggestion, you can apply this method to the bracket - bushing problem to expand the bushing hole under a specific thermal load and on the next step of the analysis install the bushing in place to study the effects of hole contraction on the contact surface of the bushing. This will be closer to the real life practices for bushings installations.

    • @Aeroswap
      @Aeroswap  3 года назад

      Thanks Emmanuel ! That is a great idea. I will work on a similar case soon. I think it will have to be a transient analysis as the cooling/contraction will take place gradually.

  • @user-eh6te2xi8w
    @user-eh6te2xi8w 8 месяцев назад

    It would be very helpful, if you could upload a tutorial for the new GUI, because in the new version this tutorial can not be done.

  • @CK-me8dl
    @CK-me8dl 3 года назад +2

    What will bey the difference if we apply temperature from constraints panel and from temperature panel ?

    • @Aeroswap
      @Aeroswap  3 года назад +1

      Hello Chaitanya,
      Both the methods are equivalent. You will get the same results regardless of how the temperature is applied. Feel free to use whichever method is suitable for you!

  • @sidharthakumar1127
    @sidharthakumar1127 9 месяцев назад +1

    Hi, Good presentation. Why did you scale the model 1000 times in negative. Having units of meter is not sufficient ? instead of scaling. I did not understand. Could you please explain

    • @Aeroswap
      @Aeroswap  9 месяцев назад +1

      Good question! Hypermesh is a unit-neutral environment. You can use any unit system as long as it is consistent. For this example, the material properties that I had received were in (N, m, kg, s) unit system. As the geometry was created in mm, I had to scale it by factor of 1000 to convert it to m.
      A second approach would have been to get the material properties in (N, mm, tonne, s). Then scaling of geometry is not required.
      I hope this answers your question!

    • @sidharthakumar1127
      @sidharthakumar1127 9 месяцев назад

      Thanks for the explanation !!! Agree with the answer. 👍

  • @5253chinna
    @5253chinna 3 года назад +1

    How to do the heating of part from 20c to 60C with time of 20minutes and holding the part for 40minutes at 60c. Cooling from 60C to 30c with time of 80minues.. could u lls exllain how to do in optistruct..Here need to heat or cooling the whole part..

    • @Aeroswap
      @Aeroswap  3 года назад +1

      Hi Suresh, this can be done using a 'transient thermal analysis'. I have already posted a tutorial ahout this. Please check the 'Thermal/CFD playlist' on this channel to watch that tutorial.

  • @rohitmore2336
    @rohitmore2336 3 года назад +1

    Sir, where can I get anisotropic material properties values required to be filled with MAT9 card image(G11,G22,G33 etc & A1,A2,A3) for aluminum alloy , cast iron etc.

    • @Aeroswap
      @Aeroswap  3 года назад +1

      There are several material databases online. Just search for the specific material you are looking for and you will find the information.
      I do not know about any particular website to search material data.

  • @StudyMaterialForYou
    @StudyMaterialForYou 3 года назад +1

    Hello Sir, Nice Video....Sir...In my Hypermesh cntr+F is not working....may I know the another way to global output result or how to set shortcut in cntrl+F..Must Reply Sir

    • @Aeroswap
      @Aeroswap  3 года назад +1

      To add this card, go to- Analysis >> control cards
      You will find all the control cards listed here in alphabetical order. Just click on any control card to add it to the model.
      Then you can exit this panel and use the Entity editor window to set up the card as shown in the video.

    • @StudyMaterialForYou
      @StudyMaterialForYou 3 года назад +1

      @@Aeroswap then how did I set HD3 Output option like you did in this video....

    • @StudyMaterialForYou
      @StudyMaterialForYou 3 года назад +1

      I'm using Hm14...so only I don't find search option in top right corner....
      I need to set thermal output to hd3 like u did

    • @StudyMaterialForYou
      @StudyMaterialForYou 3 года назад +1

      I found it sir...thqqqq

    • @Aeroswap
      @Aeroswap  3 года назад +1

      All options are provided in the global output request card. If you are facing difficulty in finding these options, leave it.
      Optistruct outputs all results in H3D format by default so it will not be a big issue.

  • @ezeddinekaroui8690
    @ezeddinekaroui8690 3 года назад +1

    Thank you for the wonderful explanation !
    I would like to ask you about the ftype =3 meaning and mainly the convection coefficient H=20, is it given or should I calculate it before coz Igot stuck in this point? thank you very much.

    • @Aeroswap
      @Aeroswap  3 года назад +1

      Hello,
      Ftype=3 is the setting which specifies that we want to enter the value of convective coefficient manually. I used 20W/m^2K as it falls in the standard range of values for air.
      Feel free to change this value, and all other material characteristics according to your problem. As this analysis was not based on an actual experiment, I have used standard values for all parameters.
      Glad you liked the video :)

  • @micheleromano9371
    @micheleromano9371 3 года назад +1

    Hello, thank you for your amazing work here ! May you explain how to use the check dof 1 to 6 in the constraint windows please ?
    Thank you, rock on man !

    • @Aeroswap
      @Aeroswap  3 года назад +1

      Glad you liked the videos Michele!
      There is a checkbox next to every dof in the constraints panel. If you see a tick, it means that the dof is constrainted (motion restricted along that dof). By default, all dofs are constrained in HM. You can deselect the unwanted dofs for creating the required constraints in the model. By check dof, I simply mean that you should make sure that all dof have the tick mark!
      I hope this clears you doubt.

    • @micheleromano9371
      @micheleromano9371 3 года назад +1

      @@Aeroswap Hello, if I create different thermal loads ( as QBDY1), to put them together should I use "LOADADD" card or something else ? I keep getting "ERROR 23 - SID 18 used on Case Control data DLOAD is missing in bulk data", where SID18 is the loadadd card.
      Thank you for your efforts

    • @Aeroswap
      @Aeroswap  3 года назад

      Are you performing a transient thermal analysis? If yes, you can combine multiple trasient load entries (TLOAD) using a DLOAD card. Then assign the DLOAD in loadstep.
      If you are talking about steady state thermal as shown in this video, just put all the thermal loads in same collector. No need to use LOADADD.

    • @micheleromano9371
      @micheleromano9371 3 года назад +1

      @@Aeroswap It is a transient and now it works correctly, I didn't think about DLOAD. Thank you so much man ! Really appreciate it

    • @micheleromano9371
      @micheleromano9371 3 года назад +1

      @@AeroswapSo sorry to bother again. If I apply every single load separately, everyone of them have its own influence but If I use DLOAD to apply the loads at the same time, I can see only the influence of the first one.
      Any idea to solve this issue ?

  • @user-qu4ul4qz2x
    @user-qu4ul4qz2x Год назад

    Hi, Thank you for the excellent video, Much appreciated. When I try to perform a thermal steady state analysis, I am getting an error message like this :
    *** ERROR # 3413 ***
    Unsupported subcases in Domain Decomposition mode.
    DDM is available only for static, eigenvalue/buckling,
    frequency response and modal transient analysis.
    Is there a possible solution to this problem? Thanks in advance!

  • @konderuanil
    @konderuanil 3 года назад +1

    Hi Aeroswap
    I really apricate your work. I am performing thermal stress analysis on different component, which are having non linear contacts, bolt pretensions and pressure loads. while performing the thermal stress analysis in HM 2019.1, I am a getting an error as below.
    A fatal error has been detected during input processing:

    *** ERROR # 4734 ***
    Surface-to-surface CONTACT 1 is not supported for heat transfer
    analysis.

    *** Run terminated because of error(s) in the input data.
    Please tell me how fix this issue.

    • @Aeroswap
      @Aeroswap  3 года назад +1

      The type of contact you are using is not compatible with thermal analysis. I do not remember the exact contact definition which needs to be used for thermal analysis right now.
      Please refer the Optistruct manual to resolve this issue. Looks like a minor error, wont affect your analysis setup much.
      Just an extra info, the Altair website has free ebooks in the Training and resources section. There is an ebook for 'Thermal Analysis using Optistruct'. It is excellent to learn this topic. I would suggest you to go ahead and download that ebook, it will help a lot in your project.

    • @konderuanil
      @konderuanil 3 года назад +2

      @@Aeroswap Thank you for your quick response. i got the answer for this. we need to use node to surface contacts instead of surface to surface.
      And can you please tell me why use the constraint loads as temperature loads instead of using direct temperature loads in analysis page. what will it make difference in analysis

    • @Aeroswap
      @Aeroswap  3 года назад +2

      Good point. Both these methods will give exact same results. You can use whichever is comfortable for you!

    • @konderuanil
      @konderuanil 3 года назад +1

      @@Aeroswap thank you for your quick response ❤️❤️

  • @everythingtamil1583
    @everythingtamil1583 3 года назад +1

    The file was not opening in hypermesh 19

    • @Aeroswap
      @Aeroswap  3 года назад +1

      It is just a regular CAD file and should not cause any issues. Please check if there is a problem with your Hypermesh installation.

  • @jidnyeshpatil9306
    @jidnyeshpatil9306 3 года назад

    Can you please do linear static thermal analysis on heat sink pls pls

    • @arunbabu4506
      @arunbabu4506 3 года назад

      bro r u also doing eleation hyperworks course??

  • @yash339
    @yash339 3 года назад +1

    Can we do it in radioss?

    • @Aeroswap
      @Aeroswap  3 года назад +1

      This is an implicit linear static analysis. Radioss is an explicit dynamic solver. So Optistruct is the right choice for this type of analysis.

  • @riddhishkathar8525
    @riddhishkathar8525 3 года назад

    Hey, I am getting an ***error 1490*** Unexpected continuation card, while performing Normal modes analysis of BIW, I have to submit my work within deadline (that is today). can you tell me how to resolve that issue? The quality check is failing for approx. 1% elements but I have disabled CHECKEL card so thats not an issue. Please help!

    • @riddhishkathar8525
      @riddhishkathar8525 3 года назад

      And yes, the BiW is a 2D body

    • @Aeroswap
      @Aeroswap  3 года назад

      Are you doing a normal modes analysis or heat transfer?

    • @riddhishkathar8525
      @riddhishkathar8525 3 года назад

      @@Aeroswap normal mode analysis

    • @Aeroswap
      @Aeroswap  3 года назад +1

      Please watch the modal analysis video posted by this channel. Follow every step and do not add any extra settings. It is a tried and tested method and works for all geometries.

    • @riddhishkathar8525
      @riddhishkathar8525 3 года назад

      @@Aeroswap Yes bro, I watched it already. And followed that as well. Can you just tell what are continuation cards in hypermesh? and how to block them?