API 650 STORAGE TANK BOTTOM, ANNULAR PLATE REPLACEMENT LOW COST METHOD FOR BEGINNERS AND EXPERTS

Поделиться
HTML-код
  • Опубликовано: 28 авг 2024
  • API 650 storage tank bottom and annular plate repair, replacement, easy, low cost and fast method tutorial for fitters, supervisors and engineers. Donate paypal.me/Tech...
    This channel explain about storage tank, pressure vessels, piping fabrication, erection, welding, piping isometric,
    ndt, welding, cutting , pipe fit-up, fabrication, erection, elbow cutting, elbow center calculation, welding process, valves,
    pressure gauge, hydro testing details, welding calculation, pipe supports, equipment, pumps, Trigonometric formula
    application, pipe offset calculation, fitter, fabricator training etc. ‪@technicalstudies.‬

Комментарии • 63

  • @nobodymane185
    @nobodymane185 5 месяцев назад +2

    Very informative video and interesting methods shown. Thank you for posting this video. It’s cool to see how all of the techniques and stuff is executed.

  • @pushpapanicker8547
    @pushpapanicker8547 3 года назад +2

    Superb good job 👌👌👌👍👍👍

  • @gfhash4319
    @gfhash4319 3 года назад +1

    Great thanks, great thanks, great thank.

  • @aliihsan8374
    @aliihsan8374 Год назад +1

    wonderful video

  • @sureshanjali7679
    @sureshanjali7679 3 года назад +1

    What a great work 👌

  • @user-kv1ze1jj7n
    @user-kv1ze1jj7n 6 месяцев назад +1

    Great video. What references would you recommend for determining the minimum required size beams needed for the stiffeners? API 653 doesn't seem to cover much beyond stating they may be required.

    • @technicalstudies.
      @technicalstudies.  6 месяцев назад

      Thank you bro. As you told, minimum size is not mentioned in the cods. Structural size depends, the diameter, slope, loads on the roof, ind speed etc

  • @centerenamel905
    @centerenamel905 2 года назад +1

    Great work

  • @ratishtyre4371
    @ratishtyre4371 3 года назад +1

    Informative

  • @ghaah
    @ghaah Год назад +1

    Thank you soo much

  • @akshaichandran3806
    @akshaichandran3806 3 года назад +1

    great work

  • @Tural1036
    @Tural1036 2 года назад +1

    Thanks for this

  • @datinbin
    @datinbin 2 года назад +1

    What cutting method was used to cut the old annular away so that there was a clean straight profile on the bottom of the shell plates for welding the new annular welds. Are there photos of this work somewhere? You must also take care not to cause a differential settlement situation or cause damage to the shell bottom plate when driving in wedges. Interesting approach.

    • @technicalstudies.
      @technicalstudies.  2 года назад

      We used the gas cutting method, fortunately, our gas cutting technician was highly experienced in these types of jobs. He put a 10 thick flat bar near the corner welding and moved the cutting torch horizontally. The cutting was very smooth. Unfortunately, there was not any photograph left.

  • @vinesh6890
    @vinesh6890 3 года назад +1

    Amazing 👍🏼

  • @mugovehillary7444
    @mugovehillary7444 2 года назад +3

    hi this is interesting ,is there a course that i should to be a certified storage tank repair

    • @technicalstudies.
      @technicalstudies.  2 года назад +2

      Sorry, Bro. To my knowledge, I don't know any institution conducting certification courses for tank repair.

    • @mugovehillary7444
      @mugovehillary7444 2 года назад +2

      @@technicalstudies. okay thank you so much

  • @chandrashekharpanicker8659
    @chandrashekharpanicker8659 3 года назад +1

    Superb

  • @samik9600
    @samik9600 2 года назад +2

    API 650 is for constructing a new above ground liquid storage tank while API 653 is for the maintenance of an API 650 to determine whether the tank fit for continued service.

    • @technicalstudies.
      @technicalstudies.  2 года назад

      Bro, you are right, but for some corrections, API 650 stands for atmospheric pressure. API 653 stands for whether the tank fits for continued service. Thank you for the comment.

  • @saranyadevi6468
    @saranyadevi6468 Год назад +1

    super bro

  • @redmanizer31
    @redmanizer31 3 месяца назад +1

    More vids please

  • @essamhassan5810
    @essamhassan5810 3 месяца назад +1

    How to apply RT on weld seams joining annular plates together ?

    • @technicalstudies.
      @technicalstudies.  3 месяца назад

      I am sure, you know the answer. Mostly the client will not ask you, when you repare and replace the annular plates.

  • @bouhaniafaycal9523
    @bouhaniafaycal9523 2 года назад +1

    What is the correct scissor seal installation method in floating roof storage tanks for hydrocarbons?

    • @technicalstudies.
      @technicalstudies.  2 года назад

      Bro, sorry for the late reply. Each and every sealing has its advantages and disadvantages. I am only a fabrication engineer.

  • @subramanyas8602
    @subramanyas8602 10 месяцев назад +1

    It is not clear on removeal of the existing annular bottom plate when wedge load is exerted on existing plate , also tnak height is reducing by 25 mm , will changes the position of nozzles

  • @kriswilliams9375
    @kriswilliams9375 3 года назад +2

    how do you perform the weld where the 2 annular plate is directly below the shell?

    • @technicalstudies.
      @technicalstudies.  3 года назад

      Thank you for the comment.We used to push two wedgs on both side of the joint between the shell and annular plate, making a gap of 20 to 25mm.

    • @TheTanker_69
      @TheTanker_69 2 года назад +1

      @@technicalstudies. How to do RT for Annular joints

    • @technicalstudies.
      @technicalstudies.  2 года назад +2

      @@TheTanker_69 Hai Ketsana. Not many clients, ask for RT, in this type of replacement methods. Instead, UT and PT is possible. In case the client ask for RT is a must, then we need to change the LOW COST to HIGH COST jacking method. Thank you.

    • @ghaah
      @ghaah Год назад

      @@TheTanker_69 where do you keep film for RT

  • @jondavis809
    @jondavis809 2 месяца назад +1

    Tank repair due to corrosion... have a ceiling

  • @kevinnazeraj1799
    @kevinnazeraj1799 2 года назад +1

    So you have to raise the tank with crane or hidraulik pistons

    • @technicalstudies.
      @technicalstudies.  2 года назад

      Bro. it depends on your pocket 🤣

    • @technicalstudies.
      @technicalstudies.  2 года назад +1

      If you have dollars, I will recommend the jacking method. This is a low-cost method.

    • @kevinnazeraj1799
      @kevinnazeraj1799 2 года назад

      Yes but if the tank weight is 120 tons, is not so safe to lift it with crane right ?

  • @vipinvidhyadharan7536
    @vipinvidhyadharan7536 Год назад +1

    How you remove the existing annular plate with bothe side welding

  • @venthangeorge5303
    @venthangeorge5303 Год назад +1

    How to weld annular to annular But Joint while Shell plates rest on Annular plate??

    • @technicalstudies.
      @technicalstudies.  Год назад

      drive, wedges, between the shell and the annular plate, you will get enough gap for welding, use a needle grinder for cleaning.

  • @mapengineering4524
    @mapengineering4524 2 года назад +1

    If your tank has a false button can you use this method

  • @ravimishra1906
    @ravimishra1906 3 года назад +1

    Great work