Siemens sirius soft starter wiring.

Поделиться
HTML-код
  • Опубликовано: 17 июн 2020
  • 4-minutes tutorial on how to wire Siemens sirius 3w3 softstarter. Part 1 - control by switch, part 2 - control by push buttons.
    🔔 Click the notification bell to get a notification about new videos !
    👋 FACEBOOK👋
    *******************************
    / aboutelectricity-29164...
    #sirius #softstarter #siemens
    Disclaimer:
    I can't under any circumstances be held liable for any possible personal injury or material damage resulting from the use of this example.
    Song: Jarico - Island (Vlog No Copyright Music)
    Music promoted by Vlog No Copyright Music.
    Video Link: • Video
  • НаукаНаука

Комментарии • 27

  • @bastiangonzalez6761
    @bastiangonzalez6761 3 года назад +3

    Thanks my brother! It was very useful :) regards from Chile 🇨🇱 and God bless you in your project.

  • @ras0906
    @ras0906 Год назад +2

    Excellent video... I like your "overlay" of each step in the wiring process. Makes sense to me. Thank you.
    I am new to the field and wondering if the same wiring diagram can be applied with a 24 V AC supply voltage? Hot 24 V line replacing +24 VDC, and 24 V neutral replacing 0 VDC? We are looking at a Siemens 3RW4036-1BB05 motor starter.

  • @athilaldurry5880
    @athilaldurry5880 3 года назад

    Many thanks

  • @Vujangga
    @Vujangga 2 года назад

    Good job

  • @haitham5084
    @haitham5084 3 года назад +1

    perfect

  • @coreyellisart6877
    @coreyellisart6877 2 года назад

    Good day to you I've been watching a handful of your videos and they're pretty good demonstrations I have been meeting my head against the wall trying to figure out wiring on an old motor it's a bodine motor 6 wires too blue to black and two Brown it says to run a 10 microfarad cap on the plate but no diagram the brown wires .5 ohms the black wires 8 ohms the blue wires 18 ohms. Single phase 115 volt. I'm not sure what the 0.5 ohm wires are for

  • @haitham5084
    @haitham5084 3 года назад

    thanks

  • @joaomanuelfernandes3432
    @joaomanuelfernandes3432 2 года назад

    Can I use the wiring diagram for the 24V 3RW40 soft starter or does it have changes

  • @bastiangonzalez6761
    @bastiangonzalez6761 3 года назад

    I have a question: a few words, the terminal A1 and A2, always must be energized? The terminal that gives the signal of startup in the circuit is the IN? Thanks brother.

  • @WeconTechnology
    @WeconTechnology Год назад +1

    Hi, are you still making videos?

  • @jesusnavarrotei1159
    @jesusnavarrotei1159 3 года назад +1

    active traduccion automatica a sus videos gracias

  • @himansusahu8850
    @himansusahu8850 3 года назад

    Please make a video on how to read a circuit diagram of closing and tripping circuit of breaker like L&T ACB, siemens,alstrom,areva VCB.plz reply me

  • @robertomuhammad35
    @robertomuhammad35 Год назад

    Hi . Can use soft starter with 220v single phase ?

  • @MsJack111111
    @MsJack111111 5 месяцев назад

    How would you connect the motor up?
    If its in delta?

  • @azuzkharef2293
    @azuzkharef2293 2 месяца назад +1

    ،GOOD

  • @hanhlang6329
    @hanhlang6329 3 года назад

    relay duelco nst 2002.2 user manual.help me!

  • @Jp-jg8xu
    @Jp-jg8xu 3 года назад

    Qual e o nome da música?

  • @vishukatariya9149
    @vishukatariya9149 3 года назад

    Sir I do this . But it's trip automatically

  • @bigraysmith9489
    @bigraysmith9489 Год назад

    Sir plz provide point names on this video

  • @fairose1052
    @fairose1052 5 месяцев назад

    Device and bypass indicator blinkong what is the issue

    • @AboutElectricity
      @AboutElectricity  5 месяцев назад

      You need to look at the manual.Should be error codes there.

  • @riteshpahladsingh3819
    @riteshpahladsingh3819 Год назад

    This wiring is wrong, why I say that. Because one phase is always live.

    • @AboutElectricity
      @AboutElectricity  Год назад

      Why is that? Give us more details so we can discuss it.

  • @nasiruddinhimu5075
    @nasiruddinhimu5075 3 года назад

    off switch 2 no wire where going ???? video rejulation very poor

    • @hanhlang6329
      @hanhlang6329 3 года назад

      Very easy

    • @hanhlang6329
      @hanhlang6329 3 года назад

      I don't know it(relay duelco nst 2002.2 user manual).help me!