HOW TO INSTALL SPD || Surge protection device for home || electrical safety

Поделиться
HTML-код
  • Опубликовано: 23 ноя 2024
  • НаукаНаука

Комментарии • 30

  • @sakibshah7710
    @sakibshah7710 3 месяца назад +1

    @techmansukhpal Sir second earthing pados k ghr ka use kar sakte hai ? 😅

  • @Redtruthlion
    @Redtruthlion Год назад

    SPD k liye alag say earthing ki wire Jamin may dalwani padti hai kyaa

    • @techmansukhpal
      @techmansukhpal  Год назад

      Yes

    • @23saurabhdethe96
      @23saurabhdethe96 9 месяцев назад

      Sir Kya mai Alag earthing krne ka Reason jaan sakta hu​@@techmansukhpal

    • @techmansukhpal
      @techmansukhpal  9 месяцев назад +1

      Kyunki SPD surge ke liye hai. Jo ki 11KV ki line se bhi aa skti hai. Or agr ghr mein dusri earth se jodenge to three pin sockets mein ja skti hai surge
      Or wahan se appliances ki body mein

    • @23saurabhdethe96
      @23saurabhdethe96 9 месяцев назад

      @@techmansukhpal thanks you sir

    • @Redtruthlion
      @Redtruthlion 9 месяцев назад

      @@techmansukhpal ok thanks🙏

  • @ctetbtetacademy1516
    @ctetbtetacademy1516 9 месяцев назад +1

    440V होने पर ये SPD किसी उपकरण को खराब होने से बचा सकता हैं क्या।

    • @techmansukhpal
      @techmansukhpal  9 месяцев назад

      440V to normal voltage hain three phase mein

    • @ctetbtetacademy1516
      @ctetbtetacademy1516 9 месяцев назад

      440V(यानी अर्थ भी फेज हो जाता हैं) से SPD किसी उपकरण को खराब होने से बचा सकता हैं क्या

  • @ankurbharali917
    @ankurbharali917 Год назад

    Bhai maine spd lagaya tha but voo jal gaya kis wajah se jali hai aap bata sakte hai ?

    • @techmansukhpal
      @techmansukhpal  Год назад +1

      Usne apna kaam kiya isiliye jal gya. Surge aa gyi hogi

  • @barafwal253
    @barafwal253 7 месяцев назад

    Namaste ,
    Mujhe single phase ke liye ghar mein SPD lagaani hai. Kaun si purchase karoo sir?
    Single pole or Double pole?
    Single pole mein sirf 1 SPD de rahe online.
    Kya hume 2 SPD combine lagwana compulsory hota hai jisme 1 phase ka wire aur doosra Neutral wire lagana hota hai?
    Yaa bas ek akeli SPD leke usme Phase ka wire laga de aur neutral direct connect kar de?

    • @techmansukhpal
      @techmansukhpal  7 месяцев назад +1

      Ese spd kaam nhi kregi. And spd koi single ya double pole nhi hoti. Vo mcb hoti hai. Aap simply single phase AC SpD type 2 order kijiye. Phonix contact company ki

    • @barafwal253
      @barafwal253 7 месяцев назад

      @@techmansukhpal Phoenix SPD mein 335 voltage ke upar ke surge ko bypass karega jabki AMICISMART wali SPD 275 Voltage ke upar ke surge ko hi earthing karne lagegi

    • @techmansukhpal
      @techmansukhpal  7 месяцев назад +1

      Sir 335 model mein likha hai but uska Uc 320 hota hai. And 275 voltge ko surge nhi bolte. 320 wala hi sahi rhega
      275 wala boht bar change krna pdega.

    • @barafwal253
      @barafwal253 7 месяцев назад

      @@techmansukhpal Great advice brother, iska matlab yeh hai ki jo voltage likha hota hai, uske upar jaane par SPD kharab ho jaati hai and usse baar baar change Karo phir?

    • @dhandraraju8850
      @dhandraraju8850 5 месяцев назад

      Over aur under voltage device hain Jo markeet main vo is se acha hai Kiya usko earth ki bhi jarort nahi

  • @pardeepchahar0001
    @pardeepchahar0001 2 месяца назад

    Kya fayda iska jbki dono wire mcb se sidha bord me h

  • @pratibhamaurya8563
    @pratibhamaurya8563 8 месяцев назад

    Mere ghar me 11000 line baar baar aa jata hi jise pure ghar ka fan jal jata hi

  • @puranprakashdave
    @puranprakashdave 9 месяцев назад +2

    अनुपम

  • @kaifuzehen3478
    @kaifuzehen3478 3 месяца назад

    Kisi ko bhi spd chahiye mujhe msg kre

  • @gujar5546
    @gujar5546 6 месяцев назад +2

    इससे कोई फायदा नहीं है सिर्फ बेकुफ बनानी वाली बात है और कुछ नहीं