Faulty Compressor, Nuair portable Compressor now working, strip, fault find and repair

Поделиться
HTML-код
  • Опубликовано: 20 окт 2024

Комментарии • 18

  • @nobodyspecial6436
    @nobodyspecial6436 11 месяцев назад +23

    I laughed out loud when it went dark…… truly an “oops” moment….

  • @andrewlacerenza667
    @andrewlacerenza667 10 месяцев назад +1

    Rocker switches are one of the most common switches to fail, at least in my personal experience. I have an arsenal of rocker switches in my shop for when i service equipment

  • @nlousapt
    @nlousapt 11 месяцев назад +2

    Dean the knowledge you give here on RUclips it's public service. We see a lot of crap here. Thanks.

  • @refactorear
    @refactorear 11 месяцев назад +3

    5:11 lol, that was unexpected

  • @markmawson1
    @markmawson1 11 месяцев назад +6

    It looks like you might have wired the switch up wrong because when you plugged the power supply in the first time the switch never lit up and then the second time you plugged in the power supply the switch lit up

    • @deandohertygreaser
      @deandohertygreaser  11 месяцев назад +9

      i think your right, this one was bugging me. the more i think of it. there is no way that piece of alu could have caused my braker and RCD to trip. Had to have been the switch wired wrong.

    • @markmawson1
      @markmawson1 11 месяцев назад +4

      4:47 i think it was the way you said "put the live and neutral on one side and the other wires go on the other side" instead of live and neutral on the top and the other wires go on the bottom.

  • @UnderwaterSable
    @UnderwaterSable 11 месяцев назад +2

    Dean went into the Darkside, or maybe not. 😂

  • @user1766swl
    @user1766swl 10 месяцев назад

    Swap input wires group on the switch because led always on.

  • @MrRusty1trumbone
    @MrRusty1trumbone 11 месяцев назад +1

    Would like to see a review or teardown of one of the new cordless compressors.

    • @deandohertygreaser
      @deandohertygreaser  11 месяцев назад +2

      was thinking of doing just that myself. might get a new makita one and open it up

  • @xtender5
    @xtender5 9 месяцев назад

    They sure went wild with the size of that case. Do they charge by the square centimeter? 😁

  • @AutodidactEngineer
    @AutodidactEngineer 11 месяцев назад

    What do you think about Parkside Performance tools?

  • @lukemarshall239
    @lukemarshall239 11 месяцев назад +2

    I think you wired the switch incorrectly and you shorted live to neutral when turning on instead, ive not watched till the end yet but the two contacts you had continuity on should be live in and out and i think you had them the wrong way round!

  • @atillaozturk7075
    @atillaozturk7075 7 месяцев назад

    All that money for such a simple device

  • @alouisschafer7212
    @alouisschafer7212 4 месяца назад

    Could have put it in a housing half the size 😂Also these compressors go for around 100€ here. Ripoff.

  • @MrHowieZ1973
    @MrHowieZ1973 11 месяцев назад +2

    Squint and clinch . LOL Its the only safe way. You are not a man till you have been jolted a few times

  • @michaelfairchild
    @michaelfairchild 10 месяцев назад

    "Type: Superboxy"
    Things you can say about your compressor, but not your wife/girlfriend.