Bhai kva* power factor = kw matlab agar apke pass 25 kva k generator hai toh 25000 va * 0.8 = 20000 w ka load dal sakte ho 1 hp = 746 watt hota hai ,20000÷746= 26.80 hp ki motor use kar sakte ho likin hum log 20 % kam load chalte hai jis se hum generator ki life aachi milte matlab hum log 21.44 hp tak koi bhi chej chala sakte hai
Bhai aap ka calculation sahi hai lekin 20 hp motor chalne ke liye tractor bhi us hisab ka chahiye. Mera tractor 45 hp ka hai. 45hp ko 10 hp ki motor bohot heavy ho jati hai. 10 hp motor ka hi acha khasa load Ata hai tractor par. Mere hisab se 20 hp ke liye 65h ha tractor chahiye
Bhai sab calculation tpo matlab power take off k horsepower hisab se hoti hai tractor k hp se nahi ager tpo k hp kam hai toh apko kabhi output mil he nahi sakta sab balance mai hona chaiye
Hum kud 50 kva k kirloskar company k chala rahe hai mahindra 755di jiska tpo 66 hp ka hai bo max power 40 kw nikal deta hai 20 % hum kam load par chalte hai
तुमच म्हणण बरोबर आहे. पण पंख्याला पानी जवळ लागत. आमच्या ईथ पान्याच्या जवळच ट्रॅक्टर न्हेता येत नाही. ❤ व्हिडीओ आवडली असेल तर आपल्या चायनला नक्की सब्सक्राईब कर🙏
Agar yeh 25 kva ka alternator hai toh 12.5HP ki motor aaram chalegi. Aur agar aap soft starter VFD wala panel fit karo to 15 HP tak bhi motor chala sakte ho. Neutral grounding aur body earthing karo yeh safety ke liye jaruri hai.
तुम्हारा चैनल क्या सब्सक्राइब करें,,, आपको जानकारी तक नही है, आप कभी जनरेटर बोल रहे हो, कभी आर्मेचर जबकि ये दोनों गलत हैं,,, सही तो ये है कि 25Kva का अल्टरनेटर जो कि ट्रेक्टर से चला रहे हों तुम
बहुत बढ़िया जानकारी दी है आप ने। कुछ लोगों का कम ही होता है कमियां निकलना।
Bhai kva* power factor = kw matlab agar apke pass 25 kva k generator hai toh 25000 va * 0.8 = 20000 w ka load dal sakte ho 1 hp = 746 watt hota hai ,20000÷746= 26.80 hp ki motor use kar sakte ho likin hum log 20 % kam load chalte hai jis se hum generator ki life aachi milte matlab hum log 21.44 hp tak koi bhi chej chala sakte hai
Bhai aap ka calculation sahi hai lekin 20 hp motor chalne ke liye tractor bhi us hisab ka chahiye.
Mera tractor 45 hp ka hai. 45hp ko 10 hp ki motor bohot heavy ho jati hai. 10 hp motor ka hi acha khasa load Ata hai tractor par. Mere hisab se 20 hp ke liye 65h ha tractor chahiye
Bhai sab calculation tpo matlab power take off k horsepower hisab se hoti hai tractor k hp se nahi ager tpo k hp kam hai toh apko kabhi output mil he nahi sakta sab balance mai hona chaiye
Hum kud 50 kva k kirloskar company k chala rahe hai mahindra 755di jiska tpo 66 hp ka hai bo max power 40 kw nikal deta hai 20 % hum kam load par chalte hai
275 Mahindra da 20hp chal sakti ha bro
Kitne rupe laga h konsa company ka achha hai bhiya ji aur kitne hp Tak chala sakte h subersibial motar pump
Thanks for the update and your family are doing well and enjoying the
Thank you ❤
Subscribe Our Channel to watch interesting videos related tractor and farming 🙏
Sonalika 52hp 3 cilendor pe pto janretar single fej me 40 kve ka chalega bataye dekoreshan me chalana hai maharastra se hi hu
10 hp chi motor chalte hya generator war. Decoration cha load mapat asl tar chalel.
Sir ye tempo me Aisa jugad fit hoga kya?
No
Bhai 250 ampiar ki welding machine chalane ke liye 10 kw ka cromton armechr chahiye milega Kya tumare madhym se?
Ok
❤❤🎉❤❤🎉
Bhai plz reply diesel engine generator best hai ya tractor pto gernator best hai
Aap ke pass konsa tractor hai
@@farmingempire bhai mere pas new holland ka 42 hp tractor hai
@@sudhirsaw2433 aap ko daily chalana hai ya kabhi kabhi chalaoge
@@farmingempire bhai 2hp ki motar chalane ke liye kitne kva ki gernator hona jaruri hai
@@farmingempire daily use ke liye lena hai bhai reply
Kubota 45 hp cha ahe kont ani kiti kva ch generator ghav
30 te 35 kva chalel 45 hp la
Bhai ise single phase supply milti hai ki nahi
No
भाऊ डायरेक पंखा जोडला असता तर दोन लिटर डिझेल लागले असते जास्त पाणी आले असते 100%
तुमच म्हणण बरोबर आहे. पण पंख्याला पानी जवळ लागत. आमच्या ईथ पान्याच्या जवळच ट्रॅक्टर न्हेता येत नाही. ❤
व्हिडीओ आवडली असेल तर आपल्या चायनला नक्की सब्सक्राईब कर🙏
Power tiller pe chalta hay kay
No
Eka tasala kiti disel 7.5 hp motar la
3
21hp kubota la kiti kva chalel
25
Agar yeh 25 kva ka alternator hai toh 12.5HP ki motor aaram chalegi. Aur agar aap soft starter VFD wala panel fit karo to 15 HP tak bhi motor chala sakte ho.
Neutral grounding aur body earthing karo yeh safety ke liye jaruri hai.
Ok ji
Kitne hp tractor pe chal sakta hai
45hp
20hp की मोटर चलने के लीये कोनसा टक्टर चाहीये कीतने hpचाहये
Approximately 55hp
Aapki dam se aapke ghar Tak ke pipeline kitni lambi hai
Kitne inch pipe line hai
2000 feet
4 inch
Hello bhai pto pump lga do full pani dega
Bhai pto pump ke liye head water head jo hai wo pump ke pass me lgta hai
Pipeline kiti lambi chi ahe
1700 feet
Ye fraud punjab mai bahut ho raha 40 kva ka generator bata kar 20 kva ka de dete hai so aap log cheak jarur karba le
Yes🙏
एक घंटे में कितना डीजल पिता है
3 litter
Fraud bhi bhai bahut ho raha hai punjab side mai 40 kva k bol kar 30 kva k de rahe hai
Hamko lena hai kha milega
Machine shops
Price kiti ahe
Around 35k.
Aata jara jast asl
Price
Around 35000
तुम्हारा चैनल क्या सब्सक्राइब करें,,, आपको जानकारी तक नही है, आप कभी जनरेटर बोल रहे हो, कभी आर्मेचर जबकि ये दोनों गलत हैं,,, सही तो ये है कि 25Kva का अल्टरनेटर जो कि ट्रेक्टर से चला रहे हों तुम
नाम से को फर्क नही पडता भाई आप information देखो । व्हिडीओ पसंद नही है तो सब्सक्राईब मत करो कोई जरूरत नही 🙏