Closed Loop (Hydrostatic) Charge Pressure

Поделиться
HTML-код
  • Опубликовано: 16 дек 2016
  • Make sure you've watched our previous closed loop / hydrostatic videos (Part 1: • Closed Loop Systems - ... Part 2: • Closed Loop (Hydrostat... ). Now, we're going to go deep on the charge pump. What's it for? What are its flow paths? What pressure values can you expect to see it produce?
    We make these animations by hand, and you can play with them yourself on our eLearning website www.lunchboxsessions.com
    Follow us for more great videos and learning content on your preferred social network.
    LinkedIn: / cd-industrial-group-inc-
    Facebook: / lunchboxsessions
    Google+: google.com/+lunchboxsessions
    Twitter: / lunchboxsession
  • НаукаНаука

Комментарии • 42

  • @user-yw1cc1wv9k
    @user-yw1cc1wv9k 2 месяца назад

    I'm always blown away by the quality of your videos. Great content, explanations, and graphics. Keep up the good work!

  • @michaelcostello6991
    @michaelcostello6991 5 лет назад +5

    Really great video. My lecturer would never be able to explain this like you have in this simulation. Amazing !!!

  • @RailFan92
    @RailFan92 6 лет назад +1

    Great video, very useful thanks

  • @andibachrul5942
    @andibachrul5942 3 года назад

    Amazing

  • @vivekpandey841
    @vivekpandey841 4 года назад

    Nice

  • @jovanni_orb5116
    @jovanni_orb5116 2 месяца назад

    yes

  • @michaelcostello6991
    @michaelcostello6991 5 лет назад +1

    P.S. I have signed up at lunch box sessions website

  • @rajarao1200
    @rajarao1200 Год назад

    Super

  • @islamtaha6414
    @islamtaha6414 4 года назад

    You are My teacher

  • @ustarecepusta
    @ustarecepusta Месяц назад

    Teşekkür

  • @jovanni_orb5116
    @jovanni_orb5116 Год назад

    helpful

  • @Joscope
    @Joscope Год назад

    Is the best place to filter and cool the oil the outlet of the charge pump?

  • @arifindwi6121
    @arifindwi6121 3 года назад

    Hi, what if the pressure is unstable when the motor is off? It should be stable at 300 right? But it always drop to 260 every 3 seconds. Thanks.

  • @harrisonfowler4461
    @harrisonfowler4461 6 лет назад

    I have a video on my channel of my charge pump on a garden tractor. Could you take a look and tell me if it sounds like it's cavitating? I think it is, but I'm not 100%. I am certain that the noise is coming from the charge pump. I've never heard it before.

  • @raminalikhani2262
    @raminalikhani2262 3 года назад +1

    Hi there, I have a little problem with a hydraulic circuit, would you please help me,?

  • @johneduardolaborem1
    @johneduardolaborem1 7 лет назад

    Goodnight. excuse my English. It is not my language I have a caterpillar crawler loader. Its transmission is hydrostatic. Inside it uses two piston pumps. Which are driven by two hydraulic cylinders that move the oscillating plates. This transmission carries a load sensing system, which works directly with the engine revolutions. Has pilot valve, servos, main control valve etc. Has several points of pressure. One of them is called charge pressure. Is actually a pilot pressure. When I activate the pumps with the machine stopped, brakes on. This pressure does not just fall. But also that it oscillates. The manual tells me it can not fall to less than 100 psi. And falls. But it rises again and falls again. The manual tells me that an indication is possible that there is excess leakage inside the piston pump. The fault is progressive, it gets worse and worse as the oil heats up. my question is. If there is leakage inside the pump, should not it fall and stay there? Bone should not rise again, then fall. Or will I miss any adjustments? Thanks here I leave the link ruclips.net/video/daUvDyvMzmg/видео.html. The hydraulic scheme is very similar to this. I believe that leaks break the bonds in unity.
    I want to add that the traction motors have no leakage since they block them, and the fault continues. Then, in a few words. My question is simple. A low load pressure is indicative of a leak in the main pumps? Is this why when I turn the lever fnr to max foward the oscillating plates come in and out? The load pump is gears and was tested on a bench and that's fine. I leave another link for you to see part of the system. Is very similar to the one you speak. Thank you. Https://ruclips.net/video/2q7clRhUOqw/видео.html

  • @HauNguyen-tn3vn
    @HauNguyen-tn3vn 11 месяцев назад

    what happen when turn the swash plate from full angle to zero intermediately , the remain flow will pass through hot oil relief??

  • @samirboualem3547
    @samirboualem3547 Год назад

    Please What could be the issue when a shuttle valve fluctuate between 200psi and 500 psi, for your information charge pump was adjusted 400psi and shuttle valve was adjusted 350psi, I had replaced shuttle valve but still the same issue, I have doubt maybe be one of 4 motors failed, what do you think?

  • @JP-hk7qs
    @JP-hk7qs 4 года назад

    I have little problem with Hydrostatic pump please can i get help

  • @vivekpandey841
    @vivekpandey841 4 года назад

    What advantage close circuit

  • @user-is1kk3zr4r
    @user-is1kk3zr4r 3 года назад

    How can I get this program

  • @shibaramreddy1874
    @shibaramreddy1874 5 лет назад

    Accumulator charging system

  • @pradachannel7940
    @pradachannel7940 Месяц назад

    how to decrease motor rpm?

  • @Mikemrs781
    @Mikemrs781 5 лет назад +1

    Why is the tank line in blue passing through the msin pump again on its way to the tank?

    • @sammy-me4xn
      @sammy-me4xn 4 года назад

      Bcoz its a closed loop circuit or else each pump rotation has to suck fresh oil from tank, as there is pump leakage and also pump case drain (not shown ) some hot oil passed off and cold oil is replenished by charge pump

  • @thunderbirdbob1
    @thunderbirdbob1 7 лет назад

    I have a eaton 70145 lal pump with a charge pump. your video helped me understand it a little bit better but not completely. could someone contact me to help me out?

    • @thunderbirdbob1
      @thunderbirdbob1 7 лет назад +1

      LunchBox Sessions ok I just took a look at your part 1 I think I understand now. if I do have any more questions I will contact you thank you vary much. if you check out my video my most recent one shows you what I'm doing. if you have any suggestions please let me know. thanks bob

  • @archaosy
    @archaosy 7 лет назад

    Why not redirect the Hot Oil Shuttle directly to the motor to cool it down? The pump already gets cooled oil from the charge pump, while I think the motor could overheat this way. Am I wrong? Nice video still thx!

    • @lunchboxsessions
      @lunchboxsessions  7 лет назад +3

      You are correct that sometimes the output from the hot oil shuttle is directed through the motor case. On a motor with two case ports, one for flushing-in and one for draining-out, this is then called a full flushing loop. Help with cleaning away contaminants and wear particles, and can help a little bit with heat.
      Many motors in closed loop, hydrostatic systems now self-flush using a small amount of the main loop, inlet flow and then draining back to tank on a single case drain line.
      Great question, thanks for writing. - Carl

    • @archaosy
      @archaosy 7 лет назад

      Thank you very much for the answer. Much appreciated!

    • @jcolivera881
      @jcolivera881 3 года назад

      LunchBox Sessions this is the case an a lot of poclain driven self propelled equipment!

  • @workwillfreeyou
    @workwillfreeyou 6 лет назад

    So the main pump case has up 300psi?

  • @garymatusavige3639
    @garymatusavige3639 4 года назад

    Ok on a eaton 70144 would I tee the charge line to get pressure reading

    • @jcolivera881
      @jcolivera881 3 года назад

      Is the Eaton motor ran off of charge pressure?

    • @garymatusavige3639
      @garymatusavige3639 3 года назад

      @@jcolivera881 not sure mine is still working

  • @NorAlb_Chainsaw_Carver
    @NorAlb_Chainsaw_Carver 5 лет назад

    How is it possible that the charge pump can open the check valve at 260psi yet fails to open it at 300psi when it's going over relief?

    • @diegoortiz1012
      @diegoortiz1012 5 лет назад

      I think that it opens the check valve at 300 psi, but just for a brief moment: as son as the swash plate is centered, oil might flow long enough to put pressure right after the check valve, but once both pressures are 300 psi, oil can't keep flowing through either check valve and it goes through the charge pump relief valve.

    • @simclardy1
      @simclardy1 4 года назад +1

      The pressures balance on both sides if the check valve so no flow.

  • @OriginalAyron
    @OriginalAyron 4 года назад +1

    What would cause a huge drop in charge pressure when the main pump is in full displacement. The identical pumps drop from 350 to 300 and the faulty one drops to 150

    • @JP-hk7qs
      @JP-hk7qs 4 года назад +1

      I have the same problem did u solve that

    • @OriginalAyron
      @OriginalAyron 4 года назад

      @@JP-hk7qs turns out it was bypassing in the motor which had a failed piston. You could visually see the motor slowdown/stop at a certain point during the revolution

    • @jcolivera881
      @jcolivera881 3 года назад

      I was going to say check your case drain flow on whatever those pumps were running.