PCB FAULTS: How to TEST & FIX

Поделиться
HTML-код
  • Опубликовано: 13 июн 2024
  • Before any work is done on any boiler you should do this 4 Part test. Our yellow (easy to follow) FAULTS book and APP has this and a lots lots more information to solve this and most other problems.
    Our “Special Offer” is order both books, order value £40.00 include. P&P no vat UK Post Code only.
    Order the books & CO2 chart from
    www.mrcombi.com/shop/
    Our APPs are all one price £4.99 no vat
    Apple iOS download: apps.apple.com/gb/developer/m...
    Google Play download: play.google.com/store/search?...
    BOOKS: www.mrcombi.com/shop/
  • ХоббиХобби

Комментарии • 54

  • @muwafaksaid5934
    @muwafaksaid5934 2 месяца назад +1

    Thank you very much, for a very kind explanation.

    • @mrcombiBedford
      @mrcombiBedford  2 месяца назад

      Dear Muwafak, thanks for the kind words, glad to help, take care, George Staszak 🤩👍

  • @worldofparker
    @worldofparker Год назад +1

    good clear thorough explanations. Also info I've never heard before, such as the effect of a voltage on the neutral causing pump and zone valve issues.

    • @mrcombiBedford
      @mrcombiBedford  Год назад

      Thanks for comment, yes you are correct, too many installers still don''t do a short circuit test and spend hours on a fault then give up.All the best, george 🤩

  • @user-id9bf7hn4v
    @user-id9bf7hn4v 2 года назад +1

    This is actually top notch - Thankyou💯

    • @mrcombiBedford
      @mrcombiBedford  2 года назад

      👍thank for comment, take care, george

  • @Goon10110
    @Goon10110 2 года назад +1

    Very enjoyable video and highly informative. Thank you

    • @mrcombiBedford
      @mrcombiBedford  2 года назад

      Dear Doves, thanks for the kind comment glad you found it helpful regards George Staszak

  • @MOB30A
    @MOB30A 2 года назад +1

    Thank you very much for applauding these type of videos. Very informative and helpful, very nicely and politely style. Thanks again.

    • @mrcombiBedford
      @mrcombiBedford  2 года назад +1

      Hi Mo, Thanks for the kind review, it's good to know my videos are making a difference, take care, George Staszak

    • @MOB30A
      @MOB30A 2 года назад

      @@mrcombiBedford
      Thank you very much for your reply. I strongly believe that people who spread and share their knowledge to others, only for sake of god, they always get rewarded🤲

    • @mrcombiBedford
      @mrcombiBedford  2 года назад +1

      @@MOB30A Thanks you are correct, regards george

  • @ivandrozd8262
    @ivandrozd8262 3 года назад +1

    Very good presentation. 👍👍👍

    • @mrcombiBedford
      @mrcombiBedford  3 года назад

      Hi Ivan, thank you for the nice review, take care, george

  • @fificee8968
    @fificee8968 Год назад +1

    Great informative video 💯

    • @mrcombiBedford
      @mrcombiBedford  Год назад

      Thanks for your kind comment, all the best, George Staszak, ❤👍

  • @017hamilton
    @017hamilton 2 года назад +1

    Brilliant thank you

    • @mrcombiBedford
      @mrcombiBedford  2 года назад

      Thanks you for your comment, all the best george

  • @munnstar12
    @munnstar12 Год назад +1

    Hi combi and all gas knowledge folks here, I have an ideal logic c30 base model. Hot water is perfect but CH doesn't warm the house. I notice that the main selected knob for CH on the boiler itself only shows a digital range from 30 to 35 degrees C when the spec sheet shows it being min 30 C max 80 C .The DHW is fine and shows min 40 C and max 65 C, which matches spec sheet. I am being told PCB replacement required. Have you ever encountered something similar.

    • @mrcombiBedford
      @mrcombiBedford  Год назад

      Hi Munn91, Thanks for asking, All combies and HW cylinder settings the HW MAX is 60C, (except combies in the late spring / early autumn maybe turn down to 40C because the incoming water is hotter) CH all combies are set to 75/80 which most homes is TOO high (expensive) If you can set 60C saves lots of money! Danger, see my videos on heat loss etc. too many installers don't do this, stick any undersized rad in the lounge, to get hot the home owner has to turn both stats high to get warm and expensive.
      All the best, George Staszak

  • @royharwood
    @royharwood Год назад +1

    Hi George
    Great video, really clear explanation.
    My vaillant boiler is showing S30 fault code, no heating demand from external contol. I have hot water but no heating. I have changed the roomstat but no change. I notice that the roomstat instruction say that the power to it is 230v but when measured it reads
    4.5v when turned up to max and 50v when turned to minimum.
    Does the roomstat get its power from the pcb?. I can get the heating on if I press + & - together.
    But it goes off after it reaches full temperature.

    • @mrcombiBedford
      @mrcombiBedford  Год назад

      Hi Roy,
      Thanks for asking, very easy to test Vaillant or any boiler for NO CH.
      I assume the new stat is digital, turn it down to the lowest setting.
      If you DON'T have 230v on 4 SW.L its controls
      If you DO have 230v on 4 it's the boiler / pcb.
      1st Turn OFF the power to remove (in your case) the wires from terminals. 3 Com. and 4 SW.L and make safe the ends. Link a wire across 3 & 4 now you are to factory mode.
      Power ON select max CH on the boiler front, if it works you have a controls fault, ie. programmer R/S or the wire in-between.
      2. VOLTS: Check 230v from EARTH to L.
      0v on Natural
      230v 3 and and on 4.
      < 230 on 3 that's PCB, if more the 6 years change for latest version, if boiler is about 12 years change it etc.etc. because not economical to repair. Hope that helps.
      All the best, george 👍

  • @brendanwilkes5333
    @brendanwilkes5333 3 года назад +1

    Great demonstration, so many engineers out there don’t know they’re dead checks correctly 👍

    • @mrcombiBedford
      @mrcombiBedford  3 года назад +1

      Hi Brendan, you are correct, this easy test will show if safe to switch on without blowing up. take care and thanks for you comment . george

    • @canturgan
      @canturgan 2 года назад

      Their. You're welcome.

  • @korhankaraoren9299
    @korhankaraoren9299 Год назад +1

    Hi George, I have a 16 years old Glow worm 15hxi, which stopped working after a power cut. I checked 3A fuse and T630mA fuse on PCB, they are all ok. The little display doesn't show anything when turned on. Could it be PCB or display card, any advise? Thanks

    • @mrcombiBedford
      @mrcombiBedford  Год назад

      Hi Korhan, thanks for asking, love your boiler installed and fixed lots, there is always a risk when the power is turned OFF for the PCBs and programmers to fail, I always told the customer, this affects anything past 8 years, the software cannot cope with the switching ON surge.
      I had a look at cost of both boards £300+ fitting? To be honest start again, as I have said many times rip the whole system out, or really flush 3 times, recalculate ALL the rads, fit balancing TRVs, auto by pass enjoy the efficacy and save MONEY compared to this boiler. To get the longest guarantee find a factory hero installer have it seen EVERY year to keep the insured policy. get 3 quotes, hope that helps, regards George Staszak 😄

  • @lemonkeyconvertible848
    @lemonkeyconvertible848 2 года назад

    Superb 👍

    • @mrcombiBedford
      @mrcombiBedford  2 года назад

      Thanks for the kind words, take care, george staszak

  • @MOB30A
    @MOB30A 2 года назад +1

    Hi George.
    I have a Valliant system boiler. What symptoms would confirm if the PCB board is faulty? Also, what symptons would confirm that the flow and return NTC sensor is faulty? Thanks.

    • @mrcombiBedford
      @mrcombiBedford  2 года назад +1

      Hi Mo, thanks for asking, as with all boilers the NTC / sensor testing is the same, at room temperature 20c (the boiler is cold) check the ohms of each sensor to specks, normally 10 - 12KΩ : Vaillant are different only one wire to earth ( I love this method, dry pocket one wire to earth) the value is 1-5KΩ at room temp about 2.5K. The green sensors eg. Ferroli you must call tech for values. There is a chart which is in the Wednesday course notes but ask your boiler tech. for a download. regards, George Staszak.

    • @MOB30A
      @MOB30A 2 года назад +1

      @@mrcombiBedford
      George you are a angel.
      Thank you very much and God bless you.

  • @frosty_soda
    @frosty_soda 2 года назад +1

    Where can I buy the Short Circuit booklet? I am in Northern Ireland so can't really do one of your training courses. Thanks mate.

    • @mrcombiBedford
      @mrcombiBedford  2 года назад

      Thanks for asking
      Both the Faults and Wiring books have all the 4 part electrical safety testing info that you need, use this link to order www.mrcombi.com/shop/
      The Faults book is better because it's all about testing and fixing boilers.
      regards, George Staszak

  • @shane_and_sue
    @shane_and_sue 2 года назад

    Having a new boiler fitted in a few days, the 2 amp fuse on the circuit board has blown again, would a standard 3 amp fuse be ok until it's fitted ? Thanks

    • @mrcombiBedford
      @mrcombiBedford  2 года назад +1

      Hi San, thanks for asking, NO the pcb HAS to have a 2 amp which is weaker than the 3 amp in the wall to stop it blowing up. Power OFF measure in ohms L & N on the pcb, if less than 100 call the factory engineer or local hero to find what is causing a short circuit. If the pcb is over 5 years replace but you MUST find out what the actual fault is otherwise the new pcb will blow up !!. regards George staszak

    • @mrcombiBedford
      @mrcombiBedford  2 года назад

      Forgot, next week a new boiler it's not worth fixing

  • @mohdrizk4478
    @mohdrizk4478 4 месяца назад +1

    My PCB won't start until I hot air blow on it!!
    Then it works for 7 hours until it completely stops working, even the display.
    Any ideas?

    • @mrcombiBedford
      @mrcombiBedford  4 месяца назад +1

      Thanks for asking, easy one or more of the soldered joints has dried out, know as "dry joint" not possible to test every one thus replace with the latest version, don't buy a recon. take care, George 🤩

  • @chohanchohan8208
    @chohanchohan8208 2 года назад +1

    A lot of gas engineer don’t even know the difference of testing AC or DC hence blow the boards and maybe other components KNOWINGLY

    • @mrcombiBedford
      @mrcombiBedford  2 года назад

      Hi Chohan, I hope not, the main reason they blow up is age (over 8 years old) and another part (pumps) cause damage. regards, george

  • @SD-Plumbing-Heating
    @SD-Plumbing-Heating 2 года назад +1

    How do you check for polarity on boilers with no on/off switch?

    • @mrcombiBedford
      @mrcombiBedford  2 года назад

      Hi Stephen, thanks for asking, have a look at my PCB video, you need to have +230vAC at the switch in the OFF mode, if it's ON then the boiler would start up and blow a fuse also we don't want the boiler working whilst testing that would be very dangerous. Hope this helps, George Staszak

    • @SD-Plumbing-Heating
      @SD-Plumbing-Heating 2 года назад

      @@mrcombiBedford Hi George.
      The Baxi 600 & 800 combi range don't have a on/off switch on the boiler. On & off comes direct from the fused spur.

    • @mrcombiBedford
      @mrcombiBedford  2 года назад

      @@SD-Plumbing-Heating How strange, then you shut down via the programmer both channels to OFF to stop it working, regards, George Staszak. Happy New Year to all and thanks for the comments

  • @nathd1748
    @nathd1748 2 года назад +1

    Except your polarity test of L to Earth will take out any RCD that the circuit is connected to....

    • @mrcombiBedford
      @mrcombiBedford  2 года назад +1

      Hi Nath, thanks for your comment and of course you are 100% correct, what that would show is the low impedance metre is the wrong one and the person has not been trained which metre to use and should not be doing this test. Many come here with wrong metres even G clamps to fix boilers? regards george 👍

  • @markjparr
    @markjparr 3 года назад +2

    Damn, thought I was going to see a portable oscilloscope and a trained engineer show you how to test a PCB?

    • @mrcombiBedford
      @mrcombiBedford  3 года назад

      Hi Mark, thanks for your comment, take care, george

    • @chimpalahee
      @chimpalahee 2 года назад

      Same! Was informative either way

  • @huyongquan6554
    @huyongquan6554 2 года назад

    TN-S earth arrangement could get 5 Voltage between N and E

    • @mrcombiBedford
      @mrcombiBedford  2 года назад

      Dear Hu, any volts on Natural is a house wiring fault and will cause a fault on any boiler, thanks for the comment.

    • @huyongquan6554
      @huyongquan6554 2 года назад

      @@mrcombiBedford Thanks for reply. I am NAPIT full scoped. Only TN-C-S earth arrangement, Neutral and Earth Voltage should be zero. others like Ture TN-S or TT earth arrangement, Neutral and Earth Voltage always not be Zero. People always say Neutral and Earth Voltage be zero, because today most of property earth arrangement are TN-C-S system or not true TN-S system. For TN-S and TT system, Earth is always the true Mass Earth. So there is current flow back to transformer by Neutral conductor ( Three phase not always/unlikely balance, neutral current is always present), so there is voltage drop between neutral inside property and connected point which neutral and earth combined together at the transformer winding and case. For TN-C-S, the Neutral and earth combined at the cut out inside the meter box, so TN-C-S neutral and earth should be zero. Regards

    • @mrcombiBedford
      @mrcombiBedford  2 года назад

      @@huyongquan6554 Many thanks for the update, take care, george