I find your tutorials excellent in sense that you describe everything in detail in nice manner. Which is essential in such type of videos. You're best (y)
Hello Zia TV Channel, Your work is so excellent that it is complete for a professional or even a normal tech interested person can understand well. I'm Vinod kumar , tech interested person doing practical work on mashines . Sir, i have aBirla Yamaha Generator model LG 2000 which i have opened the Generator Side . Pls tell me how to service Carborator - KPACCO , Full electrical wiring & Rotor service. My whatsap no.7736590672 .India
Valve setting may vary brand to brand. I have adjusted valve clearance for my 2kva intake 0.08 and exhaust 0.1 mm for gas use after consulting user manual.
Abi bht c video pari ha wo upload ho jay Last ma wiring ki video ha Video editing ma bht time lg jata ja Jo b fre time milta ha mje wo ma video pe he lagata hn Kabi to full day time he nhi nikal pata hn
Zia m ny valve bhi banae ha sahi or tabet setting bhi ki ha aap k btaey hue tariqe sy... Lakin kabhi start ho jata ha or kabhi sulf k time missing ki awaz aati ha or start nh hota....
missing plug ya gas ya petrol in ma kisi 1 ma prbm ki waja sy hoti ha tuning ma ye sab saaf kr k lg jati hn ap in sab ki saafai kr lo agar phr b missing ha to ap lgntion coil new laga lena lgntion coil plug k lye jo lead nikal kr ati ha wo isi lgntion coil sy nikal kr ati ha
Nhi bhai is pr kuch nhi lagta ha Is jega heat bth hoti ha Ye jo packing jis ko gas kit b bolty hn Ye bani he isi k lye hoti ha Is ko kisi tube ki zarorat nhi hoti ha
@@ZiaTvgenerator acha Zia bhai hamare generator me gas ka masla hy jesy k ager gas pipe kit se tora sa door ho to chalta hy or ager kit me lagaye to generator band hojata hy is me kiya masla hosakta hy ????? ??????
Valves grinding stick bolty hn Ye stick ha is k dono taraf rubber k cup bany hoty hn 1 side choty valve k lye or 2nd bary valve k lye Pr apny yahan jo kam karty hn wo petrol k lye jo paip hota ha us paip ko valve ki cap wali side na paip laga kr us sy ghomaty hn or set kr dety hn
@@ZiaTvgenerator Mera swal tha k mene generator k valves yani tappet tik kiye, lekin os k bad generator ka head bohat garm ho jata hai, ek dafa smoke bi nikla tha, dosra masla ye hai k generator khudi band ojata hai. Kia masla hai?
Oil full rhta ha engine ma ?? Oil k kam hony sy asa hota ha Ya phr engine ki speed zyada ha Ya load zyada dal rha ha Head ma hole bany huy hoty hn Jin sy air pass hoti ha jo air flywheel or rotor k fan sy ati ha Oil aany sy is hole ma mati jamna start ho jati ha Jis sy hole band hony lagty hn Hole band hony sy head garam hony lagta ha Ap mje head ki pic send kar do Ma dhkh kr ap ko is ka hal bata dn ga Mera whatsapp num ha +92 312 3902109
Plug saaf karty ho ?? Agar plug saaf ha phr b start late hota ha to ap new lgntion coil laga do IN SHAA ALLAH set ho jay ga Gas prbm kit ma ho sakti ha
Tools ki shop pe pata karna pary ga Wesy is ka use bht kam log karty hn Ap petrol wala paip ly kr kr lo Stick ko valve k oper laga kr ghomaty hn Paip ko valve k nechy sy jahan spring or cap lagti ha wahan laga kr ghoma sakty ho
Valve ache tarhan check kr leye thy ? Valve apny time pr open and close ho rhy hn ? Start karny k lye step by step check karna parta ha 1st ma ap gas ya petrol jis pr b chala rahy ho wo check karo k theak sy pass ho rha ha 2nd ma spark plug apna kam theak kar rha ha 3rd ma chock sy setting karni parti ha Prblm in ma kisi ma hoti ha Ye sb theak ho to start ho jay ga
Valve ki setting feeler gauge tool sy theak hoti ha Agar generator bilkul fre ghom rha ha ya phr kick jam karta ha to valve ko check karna parta ha Start na hony ki waja hoti ha plug ya phr coil khrab hoti ha Us k bad ata ha gas ya petrol jo b use kr rhy ho wo theak sy pass ho rha ha ya nhi Bs in ma he kisi jega prblm ho gi Ap koi or lgntion coil ko laga kr start kr k dhkho ho sakta ha coil theak sy power nhi de rhe ho
Start na hony ki kuch waja hoti hn 1st gas ko chek karo Agar thek ha to 2nd kuch petrol ko ly kr gas kit sy jo paip carborter ma ja raha ha us ma petrol dal kr or paip ko mo ko band kr k strat karo agar start ho jay to paip ko gas kit ma aram sy laga do 3rd plug chek kia karo 4rd plug ma spark ho raha ha ye chek kia karo In ma he zyada tr prblm hoti ha Agar petrol use karty ho to ap ko plug chek karna ha bs Plug ma spark chek karna ha Last choke sy b kbi prblm hoti hn choke ki b setting jo ha. Wo kia karo
Zia Bhai exaus valve tight karta hn tho self lagta ha jab exaus valve lose karta hn tho kich back Marta ha iski Kya waja hosakti ha? Air generator start nahe Hoya. Plug bhe ok ha
Zia Bhai mera GENRATOR b Masla kr Raha hai head new Dala tha One month bht Acha Chala Ab mushkil se Start hora Hai
I find your tutorials excellent in sense that you describe everything in detail in nice manner. Which is essential in such type of videos. You're best (y)
Thanks frnd
Hello Zia TV Channel,
Your work is so excellent that it is complete for a professional or even a normal tech interested person can understand well.
I'm Vinod kumar , tech interested person doing practical work on mashines .
Sir, i have aBirla Yamaha Generator model LG 2000 which i have opened the Generator Side .
Pls tell me how to service Carborator - KPACCO , Full electrical wiring & Rotor service.
My whatsap no.7736590672 .India
Such a great vedio for valves adjustment. I never watch before this kind of detail at you tube.
JazakAllah
Thanx
Valve setting may vary brand to brand. I have adjusted valve clearance for my 2kva intake 0.08 and exhaust 0.1 mm for gas use after consulting user manual.
Zia bhai 5th vedio main Oil sensor ke functioning aur wiring ka zoror bataiya ga.
Oil sensor or wiring ki video last ma ha
Abi bht c video pari ha wo upload ho jay
Last ma wiring ki video ha
Video editing ma bht time lg jata ja
Jo b fre time milta ha mje wo ma video pe he lagata hn
Kabi to full day time he nhi nikal pata hn
Zia bhaee salam is it necessary two small type cap on both spring needed bcoz it is missing some time pls reply
Wah zia bhai kia bat ha apki..
جزاك الله خير
Tankyou verymust help totureal continous
Love you bha, koshsh kayo piston khey piston chao, pistum na chaibo aa
Mashallah boht shukria AP ka
Mashallah
Zia m ny valve bhi banae ha sahi or tabet setting bhi ki ha aap k btaey hue tariqe sy... Lakin kabhi start ho jata ha or kabhi sulf k time missing ki awaz aati ha or start nh hota....
missing plug ya gas ya petrol in ma kisi 1 ma prbm ki waja sy hoti ha
tuning ma ye sab saaf kr k lg jati hn ap in sab ki saafai kr lo
agar phr b missing ha to ap lgntion coil new laga lena
lgntion coil plug k lye jo lead nikal kr ati ha wo isi lgntion coil sy nikal kr ati ha
Zia bhai plug sparking bhi continue hy m ny check ki ha...
Very nice zia
Bahut axh vidiyo hai sar g
Well done Zia Bhai. Thanks for helpful tutorials :)
Generator choke may start hota hy or choke band karny par engine stop hojata hy. Is problem ka solution kya hy.
Please kindly Do an english version of this course, we'll appreciate 🙏🏿
Mera Generater start hone k kuch hi time mai band hojata hai bht hi hit up hojata 3kva 2years old reply please
Thanks
good
ok tray karti hu sir
Zia bhai jese k apne head ka Peking lagaya kiya esper WO elfi waghera nahe laga hy kiya ??
Nhi bhai is pr kuch nhi lagta ha
Is jega heat bth hoti ha
Ye jo packing jis ko gas kit b bolty hn
Ye bani he isi k lye hoti ha
Is ko kisi tube ki zarorat nhi hoti ha
@@ZiaTvgenerator acha Zia bhai hamare generator me gas ka masla hy jesy k ager gas pipe kit se tora sa door ho to chalta hy or ager kit me lagaye to generator band hojata hy is me kiya masla hosakta hy
?????
??????
bhai 6500 generator ke valve sitting ka feeler gauge number kiya hai
hi Zia how much is the measure in millimeter to adjust the intake valve and exhaust?
Zia Bhai valve ki seat sahi Karne ke tool ko Kia kehte hain jis se valve ko ghumate hain.
Valves grinding stick bolty hn
Ye stick ha is k dono taraf rubber k cup bany hoty hn
1 side choty valve k lye or 2nd bary valve k lye
Pr apny yahan jo kam karty hn wo petrol k lye jo paip hota ha us paip ko valve ki cap wali side na paip laga kr us sy ghomaty hn or set kr dety hn
Salam Bhai petrol Engine me Chala jata h matlab engine oil or petrol mix ho ja rhe h koi solution batao
Sir, kindly tell me the problem, ohv head oil is licking after fixing 2k generator valves.
Yar mje itni english nhi ati ha
@@ZiaTvgenerator Mera swal tha k mene generator k valves yani tappet tik kiye, lekin os k bad generator ka head bohat garm ho jata hai, ek dafa smoke bi nikla tha, dosra masla ye hai k generator khudi band ojata hai. Kia masla hai?
Oil full rhta ha engine ma ??
Oil k kam hony sy asa hota ha
Ya phr engine ki speed zyada ha
Ya load zyada dal rha ha
Head ma hole bany huy hoty hn
Jin sy air pass hoti ha jo air flywheel or rotor k fan sy ati ha
Oil aany sy is hole ma mati jamna start ho jati ha
Jis sy hole band hony lagty hn
Hole band hony sy head garam hony lagta ha
Ap mje head ki pic send kar do
Ma dhkh kr ap ko is ka hal bata dn ga
Mera whatsapp num ha
+92 312 3902109
Asslam o alyekum bhai mere generator gas's pe bahot massla karta he valve b new or starting bahot let karta he kuch hall btaye plss
Plug saaf karty ho ??
Agar plug saaf ha phr b start late hota ha to ap new lgntion coil laga do
IN SHAA ALLAH
set ho jay ga
Gas prbm kit ma ho sakti ha
भाई वाल ओर वाल शिल गाईड लगाने का तरीका कियु नहीं बेताते हो
Kitna cc hai engine
GK 200 engine bay video bejo engine key setting Kelly
0.15mm and the other valve?
How much horsepower?
Naimuddin
Thank u bhai ye kaha milta he....generally
Tools ki shop pe pata karna pary ga
Wesy is ka use bht kam log karty hn
Ap petrol wala paip ly kr kr lo
Stick ko valve k oper laga kr ghomaty hn
Paip ko valve k nechy sy jahan spring or cap lagti ha wahan laga kr ghoma sakty ho
sir generator ke over size ke vavle lagaye abhe start nhen ho rha hn mera generator honda gx160
Valve ache tarhan check kr leye thy ?
Valve apny time pr open and close ho rhy hn ?
Start karny k lye step by step check karna parta ha
1st ma ap gas ya petrol jis pr b chala rahy ho wo check karo k theak sy pass ho rha ha
2nd ma spark plug apna kam theak kar rha ha
3rd ma chock sy setting karni parti ha
Prblm in ma kisi ma hoti ha
Ye sb theak ho to start ho jay ga
Zia Tv thanks bhai vavle.mn masla.tha ab generator theak chal rha hn
Plug b Thk Kam kr Raha hai valve ki timing kese check kren Uska Kuch bataen
Valve ki setting feeler gauge tool sy theak hoti ha
Agar generator bilkul fre ghom rha ha ya phr kick jam karta ha to valve ko check karna parta ha
Start na hony ki waja hoti ha plug ya phr coil khrab hoti ha
Us k bad ata ha gas ya petrol jo b use kr rhy ho wo theak sy pass ho rha ha ya nhi
Bs in ma he kisi jega prblm ho gi
Ap koi or lgntion coil ko laga kr start kr k dhkho ho sakta ha coil theak sy power nhi de rhe ho
I find that you forgot to mention the inlet valve clearance
Quá chuẩn
Zia bail gas kit kelvin sating karne be batao
Ok
Brother meray generator ka awaz bohat zyda ha plz hul bta do
sir mara genetator start nahi huraha pata nahi q ap kuch batai ya engan ki koi problam nahi hay kuch batai ya
Start na hony ki kuch waja hoti hn
1st gas ko chek karo
Agar thek ha to
2nd kuch petrol ko ly kr gas kit sy jo paip carborter ma ja raha ha us ma petrol dal kr or paip ko mo ko band kr k strat karo agar start ho jay to paip ko gas kit ma aram sy laga do 3rd plug chek kia karo
4rd plug ma spark ho raha ha ye chek kia karo
In ma he zyada tr prblm hoti ha
Agar petrol use karty ho to ap ko plug chek karna ha bs
Plug ma spark chek karna ha
Last choke sy b kbi prblm hoti hn choke ki b setting jo ha. Wo kia karo
Zia Bhai Mera 5 kva generator Hy start thk hota Hy per 10 sec k bd pickup mainten nhi hota aur misfire karta Hy mujay lagta Hy gaskit issue hy
Movie mein kirasan Tel jaane ka Karan kya hota
China Honda start hone ka Bhat Kavita ke shaadi se pehle
Sound problem give one video
Làm sao để sát định thông số của động cơ khi bị mất số liệu
Plz explain sir genertor working principle
Sory samja nhi ap ki bat
Whenever a conductor is moved in a magnetic field an emf (electromotive force) gets induced in the conductor.
Engine is used to move the conductor.
Please don't say پسٹم۔۔۔۔......it's piston
Sir apka mobile number melsaktha hai ka keu ki maih bhi Honda gx390 engine ka Kam kartha hu. Kavi jarurath para tho call karenga
Ma Pakistan ma rhta hn
Mere whatsapp num not kar lo
+92 312 3902109
Bhai mera pas 5kv ka engine ha sale Kar rha ho
سر میرا جرنیٹر کا تیپت کا بولت توت رھاہے
What's up nambar
No English I cant hear what you are saying
Bhoat khoob Zia Bhai.
Zia Bhai exaus valve tight karta hn tho self lagta ha jab exaus valve lose karta hn tho kich back Marta ha iski Kya waja hosakti ha? Air generator start nahe Hoya. Plug bhe ok ha