Great, your calculation and formulas works 100% accurate, i make 220v to 27 v transformer using 1.5 * 1.5 bobin, 22 gauge silver wire with 340 turns in input and 20 gauge wire 80 turns in output. Which works very accurately. Thank you very much for uploading the videos. Great job.
بھائی آپکی اوور لوڈ ریلے والی ویڈیو زبردست تھی اگر آپ اِسی طرح باقی ریفریجریٹر کے پارٹس کے بارے میں سمجھائیں تو بھائی آپکی بہت مہربانی ہوگی کیونکہ آپ سے بہت کچھ سیکھنے کو ملتا ہے
Salamoalaykum....... Jnab....... Apse majeed gujarish he ki ceiling fans ki winding calculation ki ek video bnaye....... My pleasure request to you....
Assalam alaikum sir, aap hame transformer Ka calculation swg yane ke wire size ke sath samjha dijiye Ku ke ham aap ke videos bahut like karte hair it's very nice
sir I want to create a step down transformer ..following value.from 220 volt ac to 50 ,60 volt out 250 ams. so what should be primary winding cycile secondary cycle( turn)?and wire gage?sing core size? please give details..
Kabhi power rating ke bare me padha hai.ji nehin To fir 60v aur 250 ampere step down tx banane se behtar hoga ap ek 15 kVA tx Ko install karlo grid substation ki permission se.eo log aur sab arrangement kar denge.
@@ranjulatanayak584 i appreciate with u ..i think u know videly about transformer nd electrical device..if u dont mind pls can u tell me what r u doing by profession. .realy ur opinion is valuable
@@ranjulatanayak584 i appreciate with u ..i think u know videly about transformer nd electrical device..if u dont mind pls can u tell me what r u doing by profession. .realy ur opinion is valuable
सर मैंने आपके सारे विडियो देखे उसमे आपने Direct EI प्लेट दिखाई, मुझे थोड़ा confusion है कि पहले ट्रांसफॉर्मर का Secondary watt निकालते है उसके बाद Primary Current निकालते हैं, उसके बाद Core Area निकालते हैं तो core area के बाद EI प्लेट कैसे सिलेक्ट करना है और bobbin कैसे Select करना है ये थोड़ा बताइए. क्यू के 0आपके सभी विडियो में Direct EI प्लेट दिखाई इसीलिए कैसे EI प्लेट सिलेक्ट करना inch या mm के अनुसार ये थोड़ा जानकारी दीजिए उसीके साथ ही अगर मल्टिपल winding हो तो वो core area के साथ EI प्लेट कैसे select करना है. धन्यवाद
Wo sab galat tarike se samjhayegi.pehle tx ki secondary power nikalte hain,us ki Baad me (core quality se ) primary input power nikalte hain. Is ki Baad me tx ki window area aur core area product Ko nikalte hain.Is ke bad core aur bobbil Ko select Kiya jata hai. Is ke bad tpv, No,Ns Ko nikala jata hai aur is ke bad me Ip,Is Ko fir Do,D's se.primary aur secondary wire gauge Ko select karte hain.iske bad wire ki length aur weight Ko calculate karke 10% jyada weight ka wire late hain.
Itne sare questions se ap ki questions Sabse jyada achha lagi.apne really intelligent question Ko pichhe hai.mujhe Matt hai ki is ka answer unki bas ki baat nehin.
Sirf 7.5 har jagah use nhi hota, ye general purpose workable solution hai. Bada transformer me flux density kam use karte hain aur jaha intermittent use hota hai, waha flux density jyada liya jata hai. Aap use ke according 5.5 se lekar 9 tak use kar sakte ho.
sir me es fomula se transfomer winding kiya hu lekin primary winding me volt shi nahi aata hai jese 12 volt ka bnata hu to 14 volt ban jata hai kirpiya kar ke hme eske bare me btaye jo ki hame propar volt mile
Hi.sir Me 3 year se transfomer winding me job kar rahahu par muje transfomet winding ke core area kese nikal te he ye janna he EX. 1KVA transfomer ke core ariya kese nikalte he
Core area=sqrt(VA)/5.88. ye generic formula hai. Companies me design ke baad kuchh models test kiya jata hai. Usme koi issue nikle, to fir se redesign karte hain core area ko ghata badha ke. Isiliye achhe brand ka transformer local ya shop pe bane transformer se jyada efficient hota hai. Upar formula square cross section ke liye valid hai.
Core area se kya milega. Pehle tx ka size is ka power handling capacity Ko Darshana hai.Jaise 1sq"*1sq"= 1 sq sq" 200 VA power handling capacity Ko Darshana hai. Fir tx bhi ek hi tarah nehin hota hai. Kisne ek coil to kis me do coil same power rating se Banta hai. Hum log jis tx Ko stabilizer me lagate is me sirf ek coil use hota hai. Is ka cost subsequent kum hota hai.
@@Dave_en sirf core area se tx bante nehin uske liye window area ki bhi jarurat Hoti hai. Tx ki size W*A product aur power handling capacity se depend karta hai. Core area sirf turns per volt ke liye hai.lekin kon SA wire kitne wire gauge me is window se fit hoga wo ek window area se nikala jata hai. Example ki tarah 7/3" aur 8/3" me core area 6 sq" hai.lekin kon SA core mejyada power handle Kiya ja Sakta hai? Kyunki his core ka window area jyada hai isme jyada thik wire laganata hai same number of turns me.to fir iska power handling capacity badhya hai ki nehin.logon Ko iski bare me achhe se samjhao na.
@@ranjulatanayak584 core stamping size ka ek standard hota hai. Log alag alag formula use karke apne hissab se core power handling capacity nikaalte hain. Aapka method bhi maine study kiya hai. Lekin practically bahut saare parameters hote hain jaise swg choose karne se pehle current density decide karenge. Commercially available transformers me maine dekha hai ki inme current density 3.7amp/mm2 ya isse jyada liya gaya hai. Mera assumption hai ki 2.5 ke aas paas lena chahiye jo American standard pe based hai. Ya aap 700/750 circular Mills per ampere ka chart dekh lo. Ye sabse best compromise hota hai. Market ka jo 12 Volt 6 amp transformer hota hai, usko mai 4.5-4.8 amp hi consider karta hu. Cost cutting me log quality compromise kar dete hain. Core window ka pata chal jata hai tongue width se, usi se aap power ka andaza laga sakte ho. Iski ratio hoti hai. Fill factor bhi matter karta hai. Jaha 1:1 ratio ke aas paas turns ratio hota hai, waha aap upto 50% hi window area cover kar sakte ho. Jaha ye ratio badh jata hai, waha fill factor 0.3-0.4 hi reh jata hai. Aap insulation kitna use karte ho, uspe bhi transformer ka size depend karta hai. Flux density 70% time 1Tesla lenge. Application pe bhi Tx size depend karta hai. Achhe company ka Tx humesha heavy hota hai. Isspe charcha ki jaay, to ek book ban jayegi. Company me bahut saara prototype testing hota hai, phir jarurat padne par redesign kiya jata hai. Temperature rise bhi ek factor hota hai. Induction motor power output pe bhi bahut sara formula hota hai, lekin practical scenerio me bahut kuchh badal jata hai. Maine to bas starting guideline diya hai ki 7.5 se core area divide karke turns per volt nikaala ja sake, lekin ye universal rule nhi hai.
Sir muze step down 60 kva ka 0 zero. 380 three eight zero. 415 four one zero. Secondary 0zero . 110 one one zero ka alluminium wire 35×25 please farmula batana jo bhi charge hoga me dunga.
Pehleaap7.5 le aaye jiska khud aap ko pata nahi ke ye kie hay , phir ye batanay ke liye ke ye 7.5 kahan se aaya ek naya formula laga diya jiss me ye nahi pata ke 4.44 kia hay aur (10
Sir g 1.5 ko x160 pher 200 pher 220 pher 240 pher 260 hr ek ke sat 1.5 ko multiply krna ha ups ka trainfarmer jis ke lop nekal ney ha ous ko 1.5 sy krna ha jawb plz
👍ecellent video sikander. very knowlegeable
Thank you very much Sir for giving me valueable info how 7.5 constant comes out. More power!
Now I want to know how to determine the current cspacity of s certain core area. Thanks for your reply!
VERY SIMPEL METHOD SIR 🙏
ecellent video ecellent explanation thanks sir
bht achi vedio thi Allah pak salamat rkhaay...
It's really helpful, thanks .......😊
Great, your calculation and formulas works 100% accurate, i make 220v to 27 v transformer using 1.5 * 1.5 bobin,
22 gauge silver wire with 340 turns in input and 20 gauge wire 80 turns in output. Which works very accurately.
Thank you very much for uploading the videos.
Great job.
very nice tech good explain very good .......
VERY GOOD & EASY METHOD
I like this tutorial
Zbrdst ab samjh ayaa tnx
Ustad Kia baat hain you are great
Very very good
waiting for next video
Good khan g
Siraaassaaaaa 👌👌👌👌👌👌👌👍👍👍👍👍👍👍👏👏👏👏
Veri simpal &good video sir
Nice video sir ji
Sir ji plz send ur whats app no
good viedeo
good thanks
very mice your video
confusions clear ho geya
Very useful information sir ji
Ager transfermer chote size ka ho ya low power ka ho tho ye 7.5 change hoga ke nahi
Nice❤
Thanks, now clear.
Good video sir
Deck k lehay transformar bananha ho2
بہت خوب سر !
لیکن پوچھنا یہ تھا کہ اس کیلئے swg کا انتخاب کیسے کریں۔۔۔۔۔
بھائی آپکی اوور لوڈ ریلے والی ویڈیو زبردست تھی اگر آپ اِسی طرح باقی ریفریجریٹر کے پارٹس کے بارے میں سمجھائیں تو بھائی آپکی بہت مہربانی ہوگی کیونکہ آپ سے بہت کچھ سیکھنے کو ملتا ہے
ویلڈنگ مشین کیلیے بھی وڈیو بناو سر
Par kyaa ye formula dc motor winding me kaam ayega?
3000 stabilizer maj ju transfermer hota hai us mai 12 v output ka transfermer ban jaiga?
BHAI kya flux density ki Value Hr transformer k liye fix rahy gi jo 60000 ap ny likhi hai.....
Kai aluminium wire ma formula change hota hai tpv find krna ka ?
Sir plz one video share for domestic transformer to find turn per volt
ok dear
bhai zan swg hisab video diya
Muze sir Apse training lena hai to kya karna padega.
Good day
super sir
kya sabhi ke liye 7.5 chalega ya phir dusara hai
Salamoalaykum....... Jnab.......
Apse majeed gujarish he ki ceiling fans ki winding calculation ki ek video bnaye....... My pleasure request to you....
7.5 se jyada area ho jese 7 ya 8inch area to bhi 7.5 hi rhega yaa 7.5se kam
Assalam alaikum sir, aap hame transformer Ka calculation swg yane ke wire size ke sath samjha dijiye Ku ke ham aap ke videos bahut like karte hair it's very nice
sr kn sa swg ka wire use kare
assalam o alekum
sir
tell me somthing about chock winding for 2000watt
sir I want to create a step down transformer ..following value.from 220 volt ac to 50 ,60 volt out 250 ams. so what should be primary winding cycile secondary cycle( turn)?and wire gage?sing core size?
please give details..
Kabhi power rating ke bare me padha hai.ji nehin
To fir 60v aur 250 ampere step down tx banane se behtar hoga ap ek 15 kVA tx Ko install karlo grid substation ki permission se.eo log aur sab arrangement kar denge.
welding set bnaoge kya?
@@ranjulatanayak584 i appreciate with u ..i think u know videly about transformer nd electrical device..if u dont mind pls can u tell me what r u doing by profession. .realy ur opinion is valuable
@@ranjulatanayak584 i appreciate with u ..i think u know videly about transformer nd electrical device..if u dont mind pls can u tell me what r u doing by profession. .realy ur opinion is valuable
please hame bataye how to connect three phase connection to single pahse motor ,
Video Acha laga thank you 🙏
Par kya aap bata sakte area ko cm mm kaise le sakte h?
सर मैंने आपके सारे विडियो देखे उसमे आपने Direct EI प्लेट दिखाई, मुझे थोड़ा confusion है कि पहले ट्रांसफॉर्मर का Secondary watt निकालते है उसके बाद Primary Current निकालते हैं, उसके बाद Core Area निकालते हैं तो core area के बाद EI प्लेट कैसे सिलेक्ट करना है और bobbin कैसे Select करना है ये थोड़ा बताइए. क्यू के 0आपके सभी विडियो में Direct EI प्लेट दिखाई इसीलिए कैसे EI प्लेट सिलेक्ट करना inch या mm के अनुसार ये थोड़ा जानकारी दीजिए उसीके साथ ही अगर मल्टिपल winding हो तो वो core area के साथ EI प्लेट कैसे select करना है. धन्यवाद
Wo sab galat tarike se samjhayegi.pehle tx ki secondary power nikalte hain,us ki Baad me (core quality se ) primary input power nikalte hain. Is ki Baad me tx ki window area aur core area product Ko nikalte hain.Is ke bad core aur bobbil Ko select Kiya jata hai. Is ke bad tpv, No,Ns Ko nikala jata hai aur is ke bad me Ip,Is Ko fir Do,D's se.primary aur secondary wire gauge Ko select karte hain.iske bad wire ki length aur weight Ko calculate karke 10% jyada weight ka wire late hain.
Very very thanks
Bhi mry pass 2 by 3 ka transforme h,,,,matlab bobin size 2*3 tu us k ly no.of turns primry, secondary bta dn,,,tar no.17 k ly
Khan sahab. Ab pori Don ke log apna transformer AP ke bataye Howe bobin pe wind karegi kia??core area or wattag me ki ratio Hy???
Nice video Bhai Jan
sir Automatic Voltage stabilizer k bary main b video banaye..k kis tara os ki loops nikali jaati hai.. konsy volt pay loop nikaly...?
Sir, agr wire thik ja thin ho. Tb kya krna chayee. Tb bhi turn same hogy kya
Itne sare questions se ap ki questions Sabse jyada achha lagi.apne really intelligent question Ko pichhe hai.mujhe Matt hai ki is ka answer unki bas ki baat nehin.
Sirf 7.5 har jagah use nhi hota, ye general purpose workable solution hai.
Bada transformer me flux density kam use karte hain aur jaha intermittent use hota hai, waha flux density jyada liya jata hai.
Aap use ke according 5.5 se lekar 9 tak use kar sakte ho.
Bobbin ki depth kaise decide karenge e.g. 4no.,5no.,6no. because these three have one side 1.5 inch
Sir ek video stebilizer par banaiye ki kaise turns calculate karte hai or kaise primary or secondary winding karte hai
Sir I want to make a coil for solar inverter and and convert from 380volt to 220 volt can you tell me formula
now , what is the POWER Handling of your CORE? please show us your formuLA
bahi ek sawal ha kindly solve krdien subha paper ha
How can I drive formula for 3 phase motor ?
Primary coil me ondor join hota hai to koi dikkat hai
Sir please aap bataye 9 0 9 amper kaise select karte hai hai 2 amper 5 amper 10 amper
nice dear...
Brother wire kon si kon say boben mah istamal honi hay kindly link send ker do
sir me es fomula se transfomer winding kiya hu lekin primary winding me volt shi nahi aata hai jese 12 volt ka bnata hu to 14 volt ban jata hai kirpiya kar ke hme eske bare me btaye jo ki hame propar volt mile
Sir winding resistance ko kese calculate karenge
Asslam alekum,, sir tern Kate calculation to thik he per hum wire ka gaj no kese nikale get,,, please ye zarro batiye
Sir transformer say amp ka step up Kya ja Santa hai please replay
ما شا اللہٰ
sir taar ka b btsye kase select kare..?
Aap ka wire gauge mota ho to same hoga aap apni book ke bare me btye
cross sectional area niklna bhi bata den
You made a good video. But I am not comfortable with it. You write in English and explain in India
Current ke bare mai bataye gauge of wire selection
Hi.sir
Me 3 year se transfomer winding me job kar rahahu par muje transfomet winding ke core area kese nikal te he ye janna he
EX. 1KVA transfomer ke core ariya kese nikalte he
Core area=sqrt(VA)/5.88. ye generic formula hai. Companies me design ke baad kuchh models test kiya jata hai. Usme koi issue nikle, to fir se redesign karte hain core area ko ghata badha ke.
Isiliye achhe brand ka transformer local ya shop pe bane transformer se jyada efficient hota hai.
Upar formula square cross section ke liye valid hai.
Core area se kya milega. Pehle tx ka size is ka power handling capacity Ko Darshana hai.Jaise 1sq"*1sq"= 1 sq sq" 200 VA power handling capacity Ko Darshana hai. Fir tx bhi ek hi tarah nehin hota hai. Kisne ek coil to kis me do coil same power rating se Banta hai. Hum log jis tx Ko stabilizer me lagate is me sirf ek coil use hota hai. Is ka cost subsequent kum hota hai.
@@Dave_en sirf core area se tx bante nehin uske liye window area ki bhi jarurat Hoti hai. Tx ki size W*A product aur power handling capacity se depend karta hai. Core area sirf turns per volt ke liye hai.lekin kon SA wire kitne wire gauge me is window se fit hoga wo ek window area se nikala jata hai. Example ki tarah 7/3" aur 8/3" me core area 6 sq" hai.lekin kon SA core mejyada power handle Kiya ja Sakta hai? Kyunki his core ka window area jyada hai isme jyada thik wire laganata hai same number of turns me.to fir iska power handling capacity badhya hai ki nehin.logon Ko iski bare me achhe se samjhao na.
@@ranjulatanayak584 core stamping size ka ek standard hota hai. Log alag alag formula use karke apne hissab se core power handling capacity nikaalte hain.
Aapka method bhi maine study kiya hai.
Lekin practically bahut saare parameters hote hain jaise swg choose karne se pehle current density decide karenge. Commercially available transformers me maine dekha hai ki inme current density 3.7amp/mm2 ya isse jyada liya gaya hai.
Mera assumption hai ki 2.5 ke aas paas lena chahiye jo American standard pe based hai. Ya aap 700/750 circular Mills per ampere ka chart dekh lo. Ye sabse best compromise hota hai.
Market ka jo 12 Volt 6 amp transformer hota hai, usko mai 4.5-4.8 amp hi consider karta hu. Cost cutting me log quality compromise kar dete hain.
Core window ka pata chal jata hai tongue width se, usi se aap power ka andaza laga sakte ho. Iski ratio hoti hai.
Fill factor bhi matter karta hai. Jaha 1:1 ratio ke aas paas turns ratio hota hai, waha aap upto 50% hi window area cover kar sakte ho.
Jaha ye ratio badh jata hai, waha fill factor 0.3-0.4 hi reh jata hai.
Aap insulation kitna use karte ho, uspe bhi transformer ka size depend karta hai. Flux density 70% time 1Tesla lenge.
Application pe bhi Tx size depend karta hai. Achhe company ka Tx humesha heavy hota hai.
Isspe charcha ki jaay, to ek book ban jayegi.
Company me bahut saara prototype testing hota hai, phir jarurat padne par redesign kiya jata hai. Temperature rise bhi ek factor hota hai.
Induction motor power output pe bhi bahut sara formula hota hai, lekin practical scenerio me bahut kuchh badal jata hai. Maine to bas starting guideline diya hai ki 7.5 se core area divide karke turns per volt nikaala ja sake, lekin ye universal rule nhi hai.
Please yah bataen ki isko kis number wire se banaenge
Good
How to calculate flux density please sir tell me
Nice bro
kuchh logon ka questions h ki 7.5 kaha se aya jo 7.5 area ka bobin hota h usme 1 volt par turn hota h ye fix h isliye core eria 7.5 se divide hota h
Sir ,transfarmer ka complete formola btain,is me kese pta chalay ga kon sa wire guge istamal ho ga or primery secondry kitne turn ho ge
I wait your answer .
Wire gauge Kon sa use karna he.....?????
Transformer ka wire gas kaise nikalta hai
Bhi tar kon se nobr ki dle gi kese pta chalega
thank you sirr tar k amp ka kasy canfurm karty h
Sir muze step down 60 kva ka 0 zero. 380 three eight zero. 415 four one zero. Secondary 0zero . 110 one one zero ka alluminium wire 35×25 please farmula batana jo bhi charge hoga me dunga.
Sir flux density kaise nikale
Sir 2by4 inch m 24v ke lea konsa guage lagega?
स्विच बोर्ड से न्यूट्रल वायर किस किस तरह से कैसे-कैसे जाता है हर पॉइंट पर सर इसकी वीडियो बनाई है
I need video about no of turn by frequency plz mohamed from Egypt thanks
Pehleaap7.5 le aaye jiska khud aap ko pata nahi ke ye kie hay , phir ye batanay ke liye ke ye 7.5 kahan se aaya ek naya formula laga diya jiss me ye nahi pata ke 4.44 kia hay aur (10
Thanks
Sir g 1.5 ko x160 pher 200 pher 220 pher 240 pher 260 hr ek ke sat 1.5 ko multiply krna ha ups ka trainfarmer jis ke lop nekal ney ha ous ko 1.5 sy krna ha jawb plz
Sir hmm inch me nanekar cm me hisab kar sakte he kya
Sir core size L 1.75 W 2.25 is transformer 50 0 50 8 amp kese winding Karen he
Sikandar Bhai wair ka batain konsa large ga
wire gauge kaise nikalna hai..?
Mai is per video daaloonga
Khan Shahib stabilizer ki connection wiring diagram pe video upload kar den
sir gi tar ka nambar kaisy malom kartay hain k kon sa nambar dala jay ga