Hi That was an excellent video on how to set up solid inverter! I am new in the game & it’s great to see someone who knows what there talking about! Thanks again! Regards mg.
This is a great video better than Solis help and videos I have followed the video to the letter and and the batteries are now not being fully charged even at midday when loads of PV power the PV power drops right of to just above loads being used ie 500w so tried time of charge run and the system did limit and drew all power from the grid, changed the setting to stop and it then limited ( time setting charge 07:00-1800 discharge 18:00-07:00) so can’t wait to see new video with more in depth instruction of the settings
I want to connect all my load to AC-backup and only use AC grid to charge battery when SOC is low or when loads on AC backup need more than battery or solar can provide. Can it be done? Basically similar to any off-grid inverter with AC-IN port.
Yes you can, that's the proper setup. Put all the AC load under your Backup Output for power protection. The hybrid will maintain your battery SOC, it will only charge if you your falls below the set value. Sample, SOC=80%, the hybrid will keep it at 80%. The 20% will be charged by your PV. If No PV , then it won't discharge beyond it's SOC level.
@@MarkMinoza What i want to achieve is to connect AC to AC-backup. I want to use cheap electricity overnight to charge battery and during the day i only want to use solar or battery to drive AC. I want to get help from the grid only if battery soc is lower than 10%. I want to avoid using grid during the day as much as possible and I don't want to export anything. What settings should I put?
buti to na adjust voltage battery parameter. yon deye na adjust din ba?. para wala ata?. pero pwde magamit to kahit wala battery ongrid lang xa?. myron ba xa self use yon time discharge pero pwde xa ma set kong ilan % lang i discharge nya?!. sample self use discharge setting time ko 6pm to 4am. pero hangang 50% lang capacity ng battery gagamitin nya?!.
@@MarkMinoza in lead acid mode i need CAN cable too? i ordered a diy battery from china with seplos BMS ,could i have it running without CAN cable in lead acid mode?
A very interesting video ! Would you give me an answer about the user settings ? I have a battery of the brand Easun 51,2v and 200ah wall mount kind regards Robert
@@MarkMinoza Hi Mark,Ok thanks for the very quick response I know that the information is on the sticker of the battery if this is entered in the user define for example is that the stocking done or are there any settings needed for charging and discharging? yes for me this is completely new to do this. Kind regards,Robert
Ok Mark thanks for the quick reply and info I will figure this out further for the settings and hopefully I won't break the inverter. best regards Robert,@@MarkMinoza
Hello! Is it possible to connect a gasoline generator to the input of the grid (s) to SOLIS RHI 5K 48ES 5G when there is no city mains for charging batteries at night)?
Hi thanks for this. I have a few questions... 1. Is there a battery calibration setting? My 15kwh batteries drain 60pc in the night and there is no chance I am using so much 2.i keep getting a highvolt.bms error....not sure why or what to do
Hello. I assembled a 48V battery myself from 16 Lifero4 cells. Capacity 105 Ah. And installed bms seplos 16s on it. I connected it to the inverter. CAN shows ok. Can you please tell me what should be the settings for such a battery?
Follow your battery data sheet on per cell level. Then multiply it by 16. Or, try to choose some of the battery setting options like Pylontech, Dyness or GSL. Most bms shared the same firmware with them.
@@geragozov you need to follow your cell data sheet based on your battery. Now, some bms manufacturer “patterned” their firmware on some well know brand, thus you can use then as well whichever it works. Consult your seller, as per our local support. Using User Define is not supported and would make your hardware void its warranty.
Hi Thanks for a great video I have followed through and battery seems to be working in self use mode. However my PV is 0. I have plugged in one string and they are reading around 300v - not sure why the inverter is not detecting them? Any advice as I think something is off somewhere in the settings?
Kindly check your Voc first without connecting it to the hardware. Please use the provided mc4 that comes with your hardware as it end points. Now, if dc1 or dc2 has an issue on , you need to inform your seller right away to claim your warranty.
Many thanks, one of the cables needed pushing in a bit more. Solar works now I have set self use and when I select allow grid - it starts to take electric from grid - I only want it to take electric during charge time (cheap electric hours). Any ideas? Thanks for your help 👍
@@magars_on_tour You can use the Timer Settings to control your charge and discharge. You have 3 timing controls under User Define or Grid Priority backup setup.
HI Mark, just had the Solis RHI5g hybrid inverter fitted along with a SMILE-BAT-10.1P battery. having issues as i dont beleive it has been set up correctly. the system shows all 4 lines of power (solar in, battery, grid and house) and will utilise the panels to the full potential when battery is charging however when battery is fully charged it only draws what the house is using from the panels and doesnt seem to put anything in the grid. The interface doesnt show CAN OK on battery or percentage and doesnt show RS485 on the house section. House rund from battery fine during evening/nightg but want to know how to fix the issue. is there anything you can advise ?
You have 2 issues at hand, incompatible battery and limiter is enabled. To rectify , Remove the canbus cable, have your battery switch to lead acid. Disable your limiter to let your hybrid export powerr.
@Mark M so i need to change the setting internally ? sorry, new to this and trying to ensure all is done correctly. could you point me in the right direction as to where to change it in settings ?
Hey, many think for video, Your headline about video is not so good you can't read anything then from the settings because my english is so good. Thanks very much
Use lead acid settings, check your dsta sheet on the following values. 1. Bulk Charge = Equalizing voltage 2. Float voltage 3. Over Discharged Voltage = DOD 4. Force Charg Voltage = EOD
Hi sir mark pwede po ba i schedule ng off ang grid pag wala ng araw ?back up nalang para sa brown out 100ah lang po kc batt ko mauubos sya pag tuloy2 magdamag
Hi Mark I have a Solis System installed but not configured properly from what I can see. I have the following battery and want to use it as self use mode only and not to charge from grid. Battery : Pylontech US3000C What options would I need to check on my inverter to see if all is configured correctly only want to use in self use mode with no charging from grid. Thank you
Hi Bhav, to prevent Solis Hybrid from charging your battery, just remove the AC Grid Charge function upon exit. But using a Polyntech battery, i would suggest to use the Backup Mode instead and enable the SOC value to your liking, then enable your AC Grid charge upon exit to maintain the battery SOC as set earlier. Above condition will only charge your battery using PV.
@@MarkMinoza Thank you Mark I am new to this and have only had this installed 2 weeks ago. Please could you give me the setting example to follow. Happy to share my email address with you? Please let me know. Many thanks
@@mistrybhavesh21 Solis Hybrid looks at the grid only when grid is available. Your backup output is powered by grid, its always bypass mode when you have a grid. You may refer this to your manual. 1. Backup -> Soc % (Battery , Load, Grid) - maintains your SOC% 2. Self Use -> Load , Battery , Grid) Thats how your hybrid function works. It always prioritize your load. When grid is not available, the. Battery will be use to power your Backup Load.
@@MarkMinoza Thank you for your brilliant illustration! Can you please explain "Allow Enable Charge from Grid" should ensure that my battery will get charged only by PV energy and not from Grid?
@@TBITS1 Using the Grid to charge your battery, its based on SOC settings on your Hybrid. If you set your SOC to 80%, the 20% will be used. It will stop discharging when it reaches 80%. GRid Charging will only charge your battery in the event you have a grid interruption and the SOC drops below the intended setup. E.G. 80% SOC, no grid --> SOC drops to 60%. When Grid available, your Grid will charge it to 80% regardless if you have a PV or not.
Hi, I can see at the end of your video you limited the backflow to 0W however it was still exporting electricity to the grid. Do you know why the inverter still shows export to the grid? Thank you
You cant prevent export to the grid, but is value is low 20-50w depending on your load behavior. Your limiter is just a feedback mechanism, there is always delta on your load vs reading.
@@MarkMinoza Thanks for your reply. My RHI-6K-48ES-5G inverter always exporting to the grid even if I set up the backflow to 0W or 1000W. It is still exporting sometimes 3000W or more. Have you ever heard of this problem? I was contacting Solis service and they never heard of this problem. Thank you
@@photoh22 Backflow should be 0000. You can see if your exporting power on your app. there are a lot of possibilities. what i can suggest is to send a video of your concern to them. Also, on your LCD screen, if your exporting, your meter icon > house load. Use Self Use to instruct the Hybrid to consume only the generated power not export it.
@@MarkMinoza thank you for your message. Yes I did send them a short video of the inverter set up already. We went through all the settings together with Solis service. But it's still exporting electricity to the grid.😟 Many thanks
@@tk5tk588 the Solis Hybrid On Grid is primarily a Grid Tie Inverter. it will work automatically as a GTi regardless if no battery is present or you have one. no special setting is required.
Thanks for the video Mark. We had this installation put in June last year and it does not seem to have saved me any money. I dont think it is configured correctly. At times that batteries seem to be dumping the power saved in them back out to the grid. I get nothing for this so all that energy is just being wasted. I want the batteries to keep the power and just use it for running the lights etc in the home. I dont want to send anything back to the grid but I cant work out how to stop it.
I have a similar problem set to self use other settings of and time of charge stop but excess PV does not go to charge the batteries, start charging from PV in the morning then stops after about an hours waits about an hour then starts again for half an hours the stops for rest of the day and batteries only charged to 45% when should charged to 100% (3 pylon U3000) So the must some other setting not setup correctly any ideas
Sir Mark, paanu po ang settings kung gusto kong magdidischarge lamang si battery sa tuwing brownout sa gabi ang grid. Kasi current status ng set up idischarge niya muna paggabi until mareach ang DOD tapus timing yung brownout kaya di siya makastart up kung low voltage na during brownout sa gabi. Salamat.
Sir yun settings mo same lang sa settings na ginawa namin except yun sa battery kasi Gel Bat gamit namin. Lead Acid setting ginawa.. Problema walang power generated galing PV panels.. may output voltage naman si pv panel sa MC4 going to inverter.. at walang voltage reading and SOLAR VOLTAGE sa INFORMATION sa inverter. Ano po kaya problema
@@MarkMinoza the Single Phase connection in the Acrel Meter Sir, if I'm not mistaken a wire is inserted to the ports #1 and #4, I would like to know where is the other end of the wire connected?
@@solarphl3329 page 72 on its manual, pin #1 and #4 is grid source. The rest doesnt need connections. www.ginlong.com/uploads/file/Solis_Manual_RHI(3-6)K_5G_ENX_V1,4_20210622.pdf
Hi, solis inverter user here question bakit po sa umaga kapag may araw na naka stock ang generating sa 20.00w need ko pa i turn off grid at ON para mag generate sya?
Sir, puidi ba gamitin ang Solis Hybrid inverter na wala ang backup battery, paano ang setting nya? Ang unit ko po ay nag pa flushing ang alarm lamp. Sigurd dahil
Yes, it will act as a regular GTi, pag walang grid, it will rely on your pv. Flashing is a sign that your PV power is lacking. Hindi po nakayanan ng PV mag supply vs load.
@@MarkMinozasir panu pag ang standard is naka user define at hindi naka PH-L? Kakainstall lang ng sakin walang battery, also anu settings ilalagay sa calibrate may total energy at power parameter
@@MarkMinoza okay lang po ba nasa nema 3r nakalagay limiter? Anu po dapat icheck pag di sync, sa metro ng meralco 1.32kw ang reading, sa panel ng solis 0.42kw ang harvest ni PV, 0.70kw ang house consumption, 0.27kw ang tulong ni grid, san po laya problema, naka ON ang 2HP aircon
Backup output po ang Off Grid power, dapat may sariling circuit. Wag isama sa main panel dahil Grid po, masusunog ang Inverter nyo pag kinabit nyo sa main Grid ang Backup output. Backup output is your emergency power supply, dyan nyo ikabit ang mga load para pag nawala ang grid, may supply parin.
why in the battery settings you set such a high charging and discharging current of 65A. After all, the battery charging current should be no more than 10 percent of the capacity, that is, in your case it should be 12A
Im using NMC type battery. I set the discharge based on my hybrid max discharge capability. You can control/limit your charge/discharge on backup function on timer settings.
Sir puidi ba gamitin ang Solis hybrid inverter kahit wala backup battery, ano po ang setting nya. Ang unit ko nag pa flushing ang alarm light, Siguro dahil wala battery.
Just enable the Control Parameter to run your backup. But dont expect it to be stable dahil wala kang battery. Kukuha lahat sa pv pag walang Grid. Pag mas malaki ang load vs pv ourput. Flashing ang load nyo.
@@rubenvillagracia4130 flashing (lights) , flushing (to flush - kubeta) - better have it consulted sa installer nyo or sa distri kung nasaan binili. Baka need palitan nila ang unit.
@@monaresernestjhon2848 Lead acid po ang option nyo pag walang canbus ang lithium battery. Walang percentage since si Hybrid, nag babaaa ng status sa canbus ni battery.
@@MarkMinoza bali ang back-up supply po namin is magdi-disable po pala talaga? Bali di po namin totally magagamit ang battery for back-up power for critical loads?
@@monaresernestjhon2848 you can, by default, the eps is bypass pag may grid. Hindi gagamitin ni Solis ang battery nyo.. Battery will only be use during power interruptions. Battery however can be used to send power to your grid and limit to offset your grid usage. Yan po ang purpose kaya may settings kayo. Im using backup mode with 70% soc. The 30% will go to the grid. Once soc is 70%, it will stop using the battery and wait for the pv to charge it the following morning.
et pourquoi quand la batterie est pleine les panneaux se coupent et c'est la batterie qui prend le relais alors que le soleil brille ! la batterie devrait se mettre en veille jusqu'à plus de soleil et là la batterie prend le relais. Comment faire ??? @@MarkMinoza
Hello Dears, can you help with setup of lead-acid baterry, I can't find the information regarding few parameters. I have four AGM LPM batteries connected in series, 100Ah, 12V. Floating(buffer) charge 13.5-13.8V (amperage of floating charge 10% of capacity 1/10C) Cycle charge 14.5-14.9V (amperage of cycle charge 10% of capacity 1/10C) What values should be setup here: Battery Capacity: 100Ah Battery OVV_Pro: ? Battery UNV_Pro: 42V Floating Voltage: ~54V Floating Current: 10A I_Max Discharge: ? A I_Max Charge: ? A Equalizing Voltage: ? V Overdischg Voltage: 44.5V Force Charg Voltage: 43.8V and what values can be used in option "Time Charging" I_charge: ? A I_Discharge: ? A
Ill just explain those missing items youve. Please refer everything to your battery data sheet. 1. Battery OVV_Pro = Over Voltage Proction 2. I_max Discharge = Maximum Current your battery can provide at 1C 3. I_max Charge = Maximum Current your battery can handle 4. Equalizing Voltage = Bulk Charge ------ for timer 5. i_charge = refer to #2 6. I_Discharge = you can control the value on how big/small the current you want to send power to the Load. HTH - Mark M
Hi! I just got a client with the same Solis setup. He’s getting an error “Relay chck: FAIL”. Any idea how can I proceed for the trouble shooting? Thanks in advance, and thank you for your videos, you got a new subscriber.
Hi, to all hybrid Solis inverter users. Paki advice po Kun ano ang setting Ng inverter, kasi namamatay siya kon Gabi pagkatapos ma abot na Niya ang back up level percentage. Hindi automatically pumapasok ang power Ng utility. Nashutdown ang inverter pag Wala Ng current supply from the battery along Lalo na sa Gabi... Ano kaya ang setting nito. Pls advice po kung papano..
35firmware, LEad-acid, user-def batt, don't want to charge from grid(((( 44V, grid charge set is ON - but nothing happen(((. Also OHBV Error soo much issue for this inverter!!!
The hybrid wont charge if you disable the grid charging ON. If your battery is Lead Acid, you cant use the User Define Battery settings. It will have an error. Set your Grid Standard properly. Use either UL208 or UL240 check your voltage) if youre having issues with your grid sync.
Hi
That was an excellent video on how to set up solid inverter!
I am new in the game & it’s great to see someone who knows what there talking about!
Thanks again!
Regards mg.
This is a great video better than Solis help and videos I have followed the video to the letter and and the batteries are now not being fully charged even at midday when loads of PV power the PV power drops right of to just above loads being used ie 500w so tried time of charge run and the system did limit and drew all power from the grid, changed the setting to stop and it then limited ( time setting charge 07:00-1800 discharge 18:00-07:00) so can’t wait to see new video with more in depth instruction of the settings
ill create one, im just having issues with my LCD. Ill make a step by step guide on what are the different backup functions and how does it work.
Se puede cambiar de modo self use a otro sin desconectar el inversor de la fotovoltaica y la red?
Si, puedes.
Your video is a GEM, you are GEM too. Thanks so much.
I want to connect all my load to AC-backup and only use AC grid to charge battery when SOC is low or when loads on AC backup need more than battery or solar can provide. Can it be done? Basically similar to any off-grid inverter with AC-IN port.
Yes you can, that's the proper setup. Put all the AC load under your Backup Output for power protection.
The hybrid will maintain your battery SOC, it will only charge if you your falls below the set value.
Sample, SOC=80%, the hybrid will keep it at 80%. The 20% will be charged by your PV. If No PV , then it won't discharge beyond it's SOC level.
@@MarkMinoza What i want to achieve is to connect AC to AC-backup. I want to use cheap electricity overnight to charge battery and during the day i only want to use solar or battery to drive AC. I want to get help from the grid only if battery soc is lower than 10%. I want to avoid using grid during the day as much as possible and I don't want to export anything.
What settings should I put?
@@paulf3353 Use Backup with SOC with Grid Charge=OFF under Self Use and enable the EPM=ON.
Can you start an commision the inverter without a battery?
In the first step I want to use it without the backup function.
Thank you.
Yes you can, its a Grid Tie Inverter and Off Grid Inverter hardware in one hardware.
Bonjour, j'ai un Solis S5EH1P3K-L. Comment paramétrer le " zéro retour vers le réseau " ?
Enable the Limiter, its shown on the video when configuring for Meter.
buti to na adjust voltage battery parameter. yon deye na adjust din ba?. para wala ata?. pero pwde magamit to kahit wala battery ongrid lang xa?. myron ba xa self use yon time discharge pero pwde xa ma set kong ilan % lang i discharge nya?!. sample self use discharge setting time ko 6pm to 4am. pero hangang 50% lang capacity ng battery gagamitin nya?!.
in user define mode i need the CAN cable connected?
@@bbiero yes, check also your battery if the CANBus pin port is standard, 4/5 pin.
@@MarkMinoza in lead acid mode i need CAN cable too?
i ordered a diy battery from china with seplos BMS ,could i have it running without CAN cable in lead acid mode?
@@bbiero lead acid don't need CANBus port. Only lithium with communication
@@MarkMinoza in lead acid mode would still have a SOC% displayed by the inverter?
@@bbiero voltage only since lead acid dont need BMS
A very interesting video !
Would you give me an answer about the user settings ? I have a battery of the brand Easun 51,2v and 200ah wall mount kind regards Robert
S5 is a bit strict when it comes to battery, you can check your data sheet on your battery and set it under User Define.
@@MarkMinoza Hi Mark,Ok thanks for the very quick response I know that the information is on the sticker of the battery if this is entered in the user define for example is that the stocking done or are there any settings needed for charging and discharging? yes for me this is completely new to do this.
Kind regards,Robert
@@Danny-cn5ty you can control charge/discharge thru Self-Use or Grid Priority settings.
Ok Mark thanks for the quick reply and info I will figure this out further for the settings and hopefully I won't break the inverter.
best regards Robert,@@MarkMinoza
Hi Mark I forgot what battery you use this is always nice to know.
greets....,
Hi Mark, charging and discharging time does not appear on mine? please do you know the reason?
Ask your local support for firmware upgrade.
Hy Could you please tell me what are the parameters to enter for a lithium powerwall?
Please check your battery data sheet. Each power walñ has different charging parameters.
sir I have s5eh1p6k-l & menred battery, same method lang ba gagawi Lead acid settings din, sa s6 kasi supported na ang menred
Under User Define puede with CANBus.
Ginaya ko na lahat dito sir lumabas ang ov illc, di parin nag discharge ang battery kahit nakaset na ang discharge time
nawala yung alert, nakakuha ako ng battery settings sa solis support. salamat
I have. 5kw on grid. Any time no grid issue come ? And. Grid r stables here
check your wiring or your mcb.
@@MarkMinoza i cheak every one r ok
@@eqabelectrician8980 have you check that your grid on the AC In had voltage?
hi, i have solis RHI-5K-48ES-5G, can you help me how i can upgrade firmware for this inverter via internet or online?
You may check the support contact under Support. www.solisinverters.com
Hello! Is it possible to connect a gasoline generator to the input of the grid (s) to SOLIS RHI 5K 48ES 5G when there is no city mains for charging batteries at night)?
Yes, adjust your grid standard based on the generator, you may start with UL-208v.
Hi thanks for this. I have a few questions...
1. Is there a battery calibration setting? My 15kwh batteries drain 60pc in the night and there is no chance I am using so much
2.i keep getting a highvolt.bms error....not sure why or what to do
Whats battery type are you using?
@@MarkMinoza hi boss.
I have 3* fox lv5200 batteries.
@@fiveaboy its compatible with Solis, you may need to upgrade the firmware to fix the issue. please contact our local support.
sir san po iconnect ung CAN,kung leadacid ang gamit na battery?
For lead acid, use your battery temperature probe. But not the canbus of the BMS. Lead acid doesn't have one.
Hello. I assembled a 48V battery myself from 16 Lifero4 cells. Capacity 105 Ah. And installed bms seplos 16s on it. I connected it to the inverter. CAN shows ok. Can you please tell me what should be the settings for such a battery?
Follow your battery data sheet on per cell level. Then multiply it by 16. Or, try to choose some of the battery setting options like Pylontech, Dyness or GSL. Most bms shared the same firmware with them.
@@MarkMinoza That is, in the menu I need to select the type of battery Pylontech or Dynes or GSL. Not a user-define? Did I understand correctly?
@@geragozov you need to follow your cell data sheet based on your battery. Now, some bms manufacturer “patterned” their firmware on some well know brand, thus you can use then as well whichever it works. Consult your seller, as per our local support. Using User Define is not supported and would make your hardware void its warranty.
Thanks bro. and may God bless you.
nice video sir.. more video pa po
Hi
Thanks for a great video
I have followed through and battery seems to be working in self use mode. However my PV is 0. I have plugged in one string and they are reading around 300v - not sure why the inverter is not detecting them?
Any advice as I think something is off somewhere in the settings?
Kindly check your Voc first without connecting it to the hardware. Please use the provided mc4 that comes with your hardware as it end points. Now, if dc1 or dc2 has an issue on , you need to inform your seller right away to claim your warranty.
Many thanks, one of the cables needed pushing in a bit more. Solar works now
I have set self use and when I select allow grid - it starts to take electric from grid - I only want it to take electric during charge time (cheap electric hours). Any ideas?
Thanks for your help 👍
@@magars_on_tour You can use the Timer Settings to control your charge and discharge. You have 3 timing controls under User Define or Grid Priority backup setup.
Sir gawa ka nmn video guide installation ng solis tandem nya ung tbb kenergier pro8.0
wala akong pambili ng Kenergier Pro sir hahaha.. i wish i can have one. :D
HI Mark,
just had the Solis RHI5g hybrid inverter fitted along with a SMILE-BAT-10.1P battery. having issues as i dont beleive it has been set up correctly. the system shows all 4 lines of power (solar in, battery, grid and house) and will utilise the panels to the full potential when battery is charging however when battery is fully charged it only draws what the house is using from the panels and doesnt seem to put anything in the grid. The interface doesnt show CAN OK on battery or percentage and doesnt show RS485 on the house section. House rund from battery fine during evening/nightg but want to know how to fix the issue. is there anything you can advise ?
You have 2 issues at hand, incompatible battery and limiter is enabled. To rectify , Remove the canbus cable, have your battery switch to lead acid. Disable your limiter to let your hybrid export powerr.
@Mark M so i need to change the setting internally ? sorry, new to this and trying to ensure all is done correctly. could you point me in the right direction as to where to change it in settings ?
@@joshward167 7:20 is the start of the advance setting. Check under meter config. Export Power Set.
Hey, many think for video, Your headline about video is not so good you can't read anything then from the settings because my english is so good. Thanks very much
Great video but i didn't understand how should i do my settings for lead acid battery
Use lead acid settings, check your dsta sheet on the following values.
1. Bulk Charge = Equalizing voltage
2. Float voltage
3. Over Discharged Voltage = DOD
4. Force Charg Voltage = EOD
Hi sir mark pwede po ba i schedule ng off ang grid pag wala ng araw ?back up nalang para sa brown out 100ah lang po kc batt ko mauubos sya pag tuloy2 magdamag
Puede, kung naka CANBus, have the Reserve SOC to 100%, it won't discharge. Enable grid charging.
@@MarkMinoza naka menred battery ESS po ako naka CAN naman po sya. Naka off po ang grid charging ko
@@MarkMinoza kailangan ko po ba sir i on ang grid charging pag i 100% ko ang SOC? Thanks.
@@buddysalvador7416 yes sir, para only for full backup lang ang battery nyo
@@MarkMinozaok po salamat sir mark
Hi Mark
I have a Solis System installed but not configured properly from what I can see.
I have the following battery and want to use it as self use mode only and not to charge from grid.
Battery : Pylontech US3000C
What options would I need to check on my inverter to see if all is configured correctly only want to use in self use mode with no charging from grid.
Thank you
Hi Bhav, to prevent Solis Hybrid from charging your battery, just remove the AC Grid Charge function upon exit.
But using a Polyntech battery, i would suggest to use the Backup Mode instead and enable the SOC value to your liking, then enable your AC Grid charge upon exit to maintain the battery SOC as set earlier.
Above condition will only charge your battery using PV.
@@MarkMinoza Thank you Mark
I am new to this and have only had this installed 2 weeks ago.
Please could you give me the setting example to follow.
Happy to share my email address with you? Please let me know.
Many thanks
@@mistrybhavesh21 Solis Hybrid looks at the grid only when grid is available. Your backup output is powered by grid, its always bypass mode when you have a grid. You may refer this to your manual.
1. Backup -> Soc % (Battery , Load, Grid) - maintains your SOC%
2. Self Use -> Load , Battery , Grid)
Thats how your hybrid function works. It always prioritize your load.
When grid is not available, the. Battery will be use to power your Backup Load.
@@MarkMinoza Thank you for your brilliant illustration! Can you please explain "Allow Enable Charge from Grid" should ensure that my battery will get charged only by PV energy and not from Grid?
@@TBITS1 Using the Grid to charge your battery, its based on SOC settings on your Hybrid. If you set your SOC to 80%, the 20% will be used. It will stop discharging when it reaches 80%. GRid Charging will only charge your battery in the event you have a grid interruption and the SOC drops below the intended setup. E.G. 80% SOC, no grid --> SOC drops to 60%. When Grid available, your Grid will charge it to 80% regardless if you have a PV or not.
Hi, I can see at the end of your video you limited the backflow to 0W however it was still exporting electricity to the grid. Do you know why the inverter still shows export to the grid? Thank you
You cant prevent export to the grid, but is value is low 20-50w depending on your load behavior. Your limiter is just a feedback mechanism, there is always delta on your load vs reading.
@@MarkMinoza Thanks for your reply. My RHI-6K-48ES-5G inverter always exporting to the grid even if I set up the backflow to 0W or 1000W. It is still exporting sometimes 3000W or more. Have you ever heard of this problem? I was contacting Solis service and they never heard of this problem. Thank you
@@photoh22 Backflow should be 0000. You can see if your exporting power on your app. there are a lot of possibilities. what i can suggest is to send a video of your concern to them. Also, on your LCD screen, if your exporting, your meter icon > house load. Use Self Use to instruct the Hybrid to consume only the generated power not export it.
@@MarkMinoza thank you for your message. Yes I did send them a short video of the inverter set up already. We went through all the settings together with Solis service. But it's still exporting electricity to the grid.😟 Many thanks
@@photoh22 never had any reported issue like that with my fellow RHI users. You may need. To update your firmware to the latest release.
Sir
What brand of battery is compatible with solis hoog.? And what is the maximum isc input of the inverter?, this will work? Without battery?
it works without battery. you may check its full specs on the link below.
www.ginlong.com/rhi_inverter1/34629.html
please guide me how to stick to non-archive load. thank
can you explain what is non-archive load?
@@MarkMinoza i want free electricity to connect to the grid. and I don't use the battery. thanks
@@tk5tk588 the Solis Hybrid On Grid is primarily a Grid Tie Inverter. it will work automatically as a GTi regardless if no battery is present or you have one. no special setting is required.
@@MarkMinoza and my inverter was not able to work without battery, can you guide
@@tk5tk588 disable your battery function under Control Parameter setting.
I keep getting alarm code 1055 (No-Battery). Does anybody know how to fix this? Thanks in advance.
Use certified Battery brand for Solis. Generic BMS will give you problems.
Thanks for the video Mark. We had this installation put in June last year and it does not seem to have saved me any money. I dont think it is configured correctly. At times that batteries seem to be dumping the power saved in them back out to the grid. I get nothing for this so all that energy is just being wasted. I want the batteries to keep the power and just use it for running the lights etc in the home. I dont want to send anything back to the grid but I cant work out how to stop it.
What battery type are you using? Its easy to configure the hybrid to act as UPS mode.
Probably it is exporting.
@@MarkMinozahow to set it up as a UPS
@@torwamugavazi645 enable the Backup under Control Parameter menu.
YOu saying lithium battery setting is to use Lead-acid setting? What type battery do you have?
Yes, im using it until now, no issues so far. All household load is handled by the solis hybrid.
Does the inverter have pre setting for BYD battery.? or any other lithium. thanks
@@Cordycep1 it has a settings for BYD battery. The hybrid manual has the list of supported battery brands.
Am using a huawei ESM-48100A1 without CAN
S5 is strict on certified battery list. Configure your battery under Lead Acid settings. Check your data sheet for charging parameters.
Which batteries are best suitable
My battery is not charging properly at times it charges and times it doesnt what might be the problem
Check your local support, have your unit patch to the latest stable release to stabilise your battery charge/discharge issue.
Sir blue carbon set ko sa lead acid batt? Yung rs485 nya? Doon ko i tap sa negative?
Yes sir, tama po.
@@MarkMinoza Sir, paano i set up/connect ang rs485 para sa blue carbon 48v 100ah?
@@fishinobi7012 wala pong canbus ang BlueCarbon battery. unless palitan nyo ang BMS nyo na may canbus capability.
@@MarkMinoza Gagana pa rin po ba ang Solis hybrid sa blue carbon kahit walang connection sa CAN?
@@fishinobi7012 yes, settings nyo sa battery is Lead Acid.
la bateria que configuró es de litio?
Si, “User Define” , pero si usted batería es LFP, tiene una configuración diferente.
Sir what mode can I set if I want from the PV to Load then the extra power will go to the battery?
Choose “Self Use”, excess power goes to the battery. Or Backup mode if your using lithium with canport enabled.
You said in you video sir that when set in "Self Use" Mode From "Pv go to the battery and the extra harvest will go to the Load" is that correct sir?
I have a similar problem set to self use other settings of and time of charge stop but excess PV does not go to charge the batteries, start charging from PV in the morning then stops after about an hours waits about an hour then starts again for half an hours the stops for rest of the day and batteries only charged to 45% when should charged to 100% (3 pylon U3000)
So the must some other setting not setup correctly any ideas
@@craigrobinson2674 ill make another video to explain different Backup Mode to understand how
Solis behaves. Receiving alot of PMs lately on it.
@@junreybarrientos9180 yes, thats how it works. Hybrid prioritizes the battery charge.
Sir Mark, paanu po ang settings kung gusto kong magdidischarge lamang si battery sa tuwing brownout sa gabi ang grid. Kasi current status ng set up idischarge niya muna paggabi until mareach ang DOD tapus timing yung brownout kaya di siya makastart up kung low voltage na during brownout sa gabi.
Salamat.
Enable the timer under Self-Use. Pag lithium with canbus gamit nyo, then enable the backup soc together wih he timer settings in self use.
Sir yun settings mo same lang sa settings na ginawa namin except yun sa battery kasi Gel Bat gamit namin. Lead Acid setting ginawa..
Problema walang power generated galing PV panels.. may output voltage naman si pv panel sa MC4 going to inverter.. at walang voltage reading and SOLAR VOLTAGE sa INFORMATION sa inverter. Ano po kaya problema
ano po ang version ng Hybrid unit nyo?
Latest Version 5G po
@@samsonapostol9546 pa check po under advance information - firmware version nyo.
como lo puedo hacer para upgradear el inversor, tengo un Solis RHI-4.6K 48ES
You can ask your local reseller for Inverter upgrade.
Question Sir, may I know the connection of Acrel Meter? Thank you very much.
What specific connection would you like to know?
@@MarkMinoza the Single Phase connection in the Acrel Meter Sir, if I'm not mistaken a wire is inserted to the ports #1 and #4, I would like to know where is the other end of the wire connected?
@@solarphl3329 page 72 on its manual, pin #1 and #4 is grid source. The rest doesnt need connections.
www.ginlong.com/uploads/file/Solis_Manual_RHI(3-6)K_5G_ENX_V1,4_20210622.pdf
@@MarkMinoza Okay Sir, thank you very much 💖
May I know Sir what is your basis in setting up the parameters in the User-Define battery set up? Like OVV, UNV etc.,
All settings are derived from my battery data sheet. Before setting it up, have your battery data sheet ready.
@@MarkMinoza what model inverter is this? All the Solis inverters I am finding like RHI-1P7.6K-HVES-5G are high voltage and the battery starts at 120v
@@mcghheea this is a single phase Hybrid On Grid model RHI-3K-48ES. Solis 3P are still in HV model. No LV yet.
Soo informative ...
Hi, solis inverter user here question bakit po sa umaga kapag may araw na naka stock ang generating sa 20.00w need ko pa i turn off grid at ON para mag generate sya?
Baka sa firmware nyo po yan. Mine is v340024. Ask your vendor to upgrade it if below that value.
it's able to connect in parallel ?
this model CAN NOT. other models can.
Sir ano ba sittings sa life4
Please refer to your LFP data sheet. Iba po ang lithium battery ko na gamin, NMC.
Sir, puidi ba gamitin ang Solis Hybrid inverter na wala ang backup battery, paano ang setting nya? Ang unit ko po ay nag pa flushing ang alarm lamp. Sigurd dahil
Yes, it will act as a regular GTi, pag walang grid, it will rely on your pv. Flashing is a sign that your PV power is lacking. Hindi po nakayanan ng PV mag supply vs load.
what type of battery is in your case?
Im using this battery. ruclips.net/video/VeixTAFvjVg/видео.html
@@MarkMinozasir panu pag ang standard is naka user define at hindi naka PH-L? Kakainstall lang ng sakin walang battery, also anu settings ilalagay sa calibrate may total energy at power parameter
@@mikecelos8713 mag depende po yan sa grid nyo, but user define would be okay. Dont touch anything, check the video kung ano ano lang sng galawin.
@@MarkMinoza okay lang po ba nasa nema 3r nakalagay limiter? Anu po dapat icheck pag di sync, sa metro ng meralco 1.32kw ang reading, sa panel ng solis 0.42kw ang harvest ni PV, 0.70kw ang house consumption, 0.27kw ang tulong ni grid, san po laya problema, naka ON ang 2HP aircon
@@mikecelos8713 check local support ni Solis, may dedicated team sila to help you. Join the Solis Inverter Support Group.
Panu po sir mag mag connect sa back up sir ilagay musa loob ng breaker sir sa main panel
Backup output po ang Off Grid power, dapat may sariling circuit. Wag isama sa main panel dahil Grid po, masusunog ang Inverter nyo pag kinabit nyo sa main Grid ang Backup output. Backup output is your emergency power supply, dyan nyo ikabit ang mga load para pag nawala ang grid, may supply parin.
why in the battery settings you set such a high charging and discharging current of 65A. After all, the battery charging current should be no more than 10 percent of the capacity, that is, in your case it should be 12A
Im using NMC type battery. I set the discharge based on my hybrid max discharge capability. You can control/limit your charge/discharge on backup function on timer settings.
Sir puidi ba gamitin ang Solis hybrid inverter kahit wala backup battery, ano po ang setting nya. Ang unit ko nag pa flushing ang alarm light, Siguro dahil wala battery.
Just enable the Control Parameter to run your backup. But dont expect it to be stable dahil wala kang battery. Kukuha lahat sa pv pag walang Grid. Pag mas malaki ang load vs pv ourput. Flashing ang load nyo.
@@MarkMinoza ang unit ay nka connect sa grid at pv at wala backup battery, ang alarm light flushing.
@@rubenvillagracia4130 flashing (lights) , flushing (to flush - kubeta) - better have it consulted sa installer nyo or sa distri kung nasaan binili. Baka need palitan nila ang unit.
Sir paano settings po pag nawalan ng power si grid tapos transfer siya sa battery power. Thanks.
Automatic po yan, may internal ATS ang Solis. Pag naka enable ang backup power , your battery will be used to supply the Backup Power
Thanks po.
Sir, yung back-up supply ko po kahit nag enable na ko, nagdidisable po kusa then flashing light po ang alarm
Check nyo po ang alarm code to better understand the status. Nakikita po yan sa Advanced Information - alarm
@@MarkMinoza sir also, yung battery ko po is lithium, lifepo4 200ah. Wala po siyang CAN port po kaya wala pong reading yung percentage sa monitor po
@@monaresernestjhon2848 Lead acid po ang option nyo pag walang canbus ang lithium battery. Walang percentage since si Hybrid, nag babaaa ng status sa canbus ni battery.
@@MarkMinoza bali ang back-up supply po namin is magdi-disable po pala talaga? Bali di po namin totally magagamit ang battery for back-up power for critical loads?
@@monaresernestjhon2848 you can, by default, the eps is bypass pag may grid. Hindi gagamitin ni Solis ang battery nyo.. Battery will only be use during power interruptions. Battery however can be used to send power to your grid and limit to offset your grid usage. Yan po ang purpose kaya may settings kayo. Im using backup mode with 70% soc. The 30% will go to the grid. Once soc is 70%, it will stop using the battery and wait for the pv to charge it the following morning.
Thank you!
Dans quel chapitre ?
start at 11:32
et pourquoi quand la batterie est pleine les panneaux se coupent et c'est la batterie qui prend le relais alors que le soleil brille ! la batterie devrait se mettre en veille jusqu'à plus de soleil et là la batterie prend le relais. Comment faire ???
@@MarkMinoza
@@louiscannarozzo9161 kindly escalate to your local support. your hybrid may need the latest patch.
tbb maxx nman sir sa sunod, slmat
yes, naka pila.. medio maraming changes si TBB Maxx kaya Im still digesting the options to properly document it.
Hello Dears, can you help with setup of lead-acid baterry, I can't find the information regarding few parameters.
I have four AGM LPM batteries connected in series, 100Ah, 12V.
Floating(buffer) charge 13.5-13.8V (amperage of floating charge 10% of capacity 1/10C)
Cycle charge 14.5-14.9V (amperage of cycle charge 10% of capacity 1/10C)
What values should be setup here:
Battery Capacity: 100Ah
Battery OVV_Pro: ?
Battery UNV_Pro: 42V
Floating Voltage: ~54V
Floating Current: 10A
I_Max Discharge: ? A
I_Max Charge: ? A
Equalizing Voltage: ? V
Overdischg Voltage: 44.5V
Force Charg Voltage: 43.8V
and what values can be used in option "Time Charging"
I_charge: ? A
I_Discharge: ? A
Ill just explain those missing items youve. Please refer everything to your battery data sheet.
1. Battery OVV_Pro = Over Voltage Proction
2. I_max Discharge = Maximum Current your battery can provide at 1C
3. I_max Charge = Maximum Current your battery can handle
4. Equalizing Voltage = Bulk Charge
------ for timer
5. i_charge = refer to #2
6. I_Discharge = you can control the value on how big/small the current you want to send power to the Load.
HTH - Mark M
@@MarkMinoza many thanks for your help!
Hi! I just got a client with the same Solis setup. He’s getting an error “Relay chck: FAIL”. Any idea how can I proceed for the trouble shooting?
Thanks in advance, and thank you for your videos, you got a new subscriber.
if it doesnt work on resetting (shutdown and start up) the Hybrid , contact your seller for more details.
Hi, to all hybrid Solis inverter users. Paki advice po Kun ano ang setting Ng inverter, kasi namamatay siya kon Gabi pagkatapos ma abot na Niya ang back up level percentage. Hindi automatically pumapasok ang power Ng utility. Nashutdown ang inverter pag Wala Ng current supply from the battery along Lalo na sa Gabi... Ano kaya ang setting nito. Pls advice po kung papano..
Dapat po naka enable ang Backup sa Control Parameter. Also, make sure na ang firmware nyo is 340024 stable release.
@@MarkMinoza Sir mark 330022 firm ware version Ang ginamit sa inverter bko. Puede ko ba palitan sa binigay mong version na 340024?
@@buenaventurapitao6017 contact your seller to have it updated. May local support naman si Solis.
35firmware, LEad-acid, user-def batt, don't want to charge from grid(((( 44V, grid charge set is ON - but nothing happen(((. Also OHBV Error soo much issue for this inverter!!!
The hybrid wont charge if you disable the grid charging ON. If your battery is Lead Acid, you cant use the User Define Battery settings. It will have an error. Set your Grid Standard properly. Use either UL208 or UL240 check your voltage) if youre having issues with your grid sync.
Good pm, baka may marecommend ka na mag commission ng 6kw solis hydrib inverter, im ely, paco manila area
You may want to join the Solis Support Group, maraming installer.
facebook.com/groups/413473389645478/?ref=share